970 resultados para video quality assessment
Resumo:
BACKGROUND: Enquiries among patients on the one hand and experimental and observational studies on the other suggest an influence of stress on inflammatory bowel diseases (IBD). However, since this influence remains hypothetical, further research is essential. We aimed to devise recommendations for future investigations in IBD by means of scrutinizing previously applied methodology. METHODS: We critically reviewed prospective clinical studies on the effect of psychological stress on IBD. Eligible studies were searched by means of the PubMed electronic library and through checking the bibliographies of located sources. RESULTS: We identified 20 publications resulting from 18 different studies. Sample sizes ranged between 10 and 155 participants. Study designs in terms of patient assessment, control variables, and applied psychometric instruments varied substantially across studies. Methodological strengths and weaknesses were irregularly dispersed. Thirteen studies reported significant relationships between stress and adverse outcomes. CONCLUSIONS: Study designs, including accuracy of outcome assessment and repeated sampling of outcomes (i.e. symptoms, clinical, and endoscopic), depended upon conditions like sample size, participants' compliance, and available resources. Meeting additional criteria of sound methodology, like taking into account covariates of the disease and its course, is strongly recommended to possibly improve study designs in future IBD research.
Resumo:
Introduction. In this era of high-tech medicine, it is becoming increasingly important to assess patient satisfaction. There are several methods to do so, but these differ greatly in terms of cost, time, and labour and external validity. The aim of this study is to describe and compare the structure and implementation of different methods to assess the satisfaction of patients in an emergency department. Methods. The structure and implementation of the different methods to assess patient satisfaction were evaluated on the basis of a 90-minute standardised interview. Results. We identified a total of six different methods in six different hospitals. The average number of patients assessed was 5012, with a range from 230 (M5) to 20 000 patients (M2). In four methods (M1, M3, M5, and M6), the questionnaire was composed by a specialised external institute. In two methods, the questionnaire was created by the hospital itself (M2, M4).The median response rate was 58.4% (range 9-97.8%). With a reminder, the response rate increased by 60% (M3). Conclusion. The ideal method to assess patient satisfaction in the emergency department setting is to use a patient-based, in-emergency department-based assessment of patient satisfaction, planned and guided by expert personnel.
Resumo:
We present an image quality assessment and enhancement method for high-resolution Fourier-Domain OCT imaging like in sub-threshold retina therapy. A Maximum-Likelihood deconvolution algorithm as well as a histogram-based quality assessment method are evaluated.
Resumo:
The liquid argon calorimeter is a key component of the ATLAS detector installed at the CERN Large Hadron Collider. The primary purpose of this calorimeter is the measurement of electron and photon kinematic properties. It also provides a crucial input for measuring jets and missing transverse momentum. An advanced data monitoring procedure was designed to quickly identify issues that would affect detector performance and ensure that only the best quality data are used for physics analysis. This article presents the validation procedure developed during the 2011 and 2012 LHC data-taking periods, in which more than 98% of the proton-proton luminosity recorded by ATLAS at a centre-of-mass energy of 7–8 TeV had calorimeter data quality suitable for physics analysis.
Resumo:
BACKGROUND: Since the discovery of Middle East respiratory syndrome coronavirus (MERS-CoV) in 2012, diagnostic protocols were quickly published and deployed globally. OBJECTIVES: We set out to assess the quality of MERS-CoV molecular diagnostics worldwide. STUDY DESIGN: Both sensitivity and specificity were assessed using 12 samples containing different viral loads of MERS-CoV or common coronaviruses (OC43, 229E, NL63, HKU1). RESULTS: The panel was sent to more than 106 participants, of which 99 laboratories from 6 continents returned 189 panel results.Scores ranged from 100% (84 laboratories) to 33% (1 laboratory). 15% of respondents reported quantitative results, 61% semi-quantitative (Ct-values or time to positivity) and 24% reported qualitative results. The major specific technique used was real-time RT-PCR using the WHO recommended targets upE, ORF1a and ORF1b. The evaluation confirmed that RT-PCRs targeting the ORF1b are less sensitive, and therefore not advised for primary diagnostics. CONCLUSIONS: The first external quality assessment MERS-CoV panel gives a good insight in molecular diagnostic techniques and their performances for sensitive and specific detection of MERS-CoV RNA globally. Overall, all laboratories were capable of detecting MERS-CoV with some differences in sensitivity. The observation that 8% of laboratories reported false MERS-CoV positive single assay results shows room for improvement, and the importance of using confirmatory targets.
Resumo:
OBJECTIVES To assess the use of quality assessment tools among a cross-section of systematic reviews (SRs) and to further evaluate whether quality was used as a parameter in the decision to include primary studies within subsequent meta-analysis. STUDY DESIGN AND SETTING We searched PubMed for SRs (interventional, observational, and diagnostic) published in Core Clinical Journals between January 1 and March 31, 2014. RESULTS Three hundred nine SRs were identified. Quality assessment was undertaken in 222 (71.8%) with isolated use of the Cochrane risk of bias tool (26.1%, n = 58) and the Newcastle-Ottawa Scale (15.3%, n = 34) most common. A threshold level of primary study quality for subsequent meta-analysis was used in 12.9% (40 of 309) of reviews. Overall, fifty-four combinations of quality assessment tools were identified with a similar preponderance of tools used among observational and interventional reviews. Multiple tools were used in 11.7% (n = 36) of SRs overall. CONCLUSION We found that quality assessment tools were used in a majority of SRs; however, a threshold level of quality for meta-analysis was stipulated in just 12.9% (n = 40). This cross-sectional analysis provides further evidence of the need for more active or intuitive editorial processes to enhance the reporting of SRs.
Resumo:
Oncologic specialty societies and multidisciplinary collaborative groups have dedicated considerable effort to developing evidence-based quality indicators (QIs) to facilitate quality improvement, accreditation, benchmarking, reimbursement, maintenance of certification, and regulatory reporting. In particular, radiation oncology as a field has a long history of organized quality assessment efforts, and continues to work toward developing consensus quality standards in the face of continually evolving technologies and standards of care. The present report provides a comprehensive review of the current state of quality assessment in radiation oncology, with an emphasis on recent quality improvement efforts. Specifically, this report aims to highlight implications of the healthcare quality movement for radiation oncology and review existing efforts to define and measure quality in the field, with particular focus on dimensions of quality that are specific to radiation oncology within the "big picture" of oncologic quality improvement efforts.^
Resumo:
This work is motivated in providing and evaluating a fusion algorithm of remotely sensed images, i.e. the fusion of a high spatial resolution panchromatic image with a multi-spectral image (also known as pansharpening) using the dual-tree complex wavelet transform (DT-CWT), an effective approach for conducting an analytic and oversampled wavelet transform to reduce aliasing, and in turn reduce shift dependence of the wavelet transform. The proposed scheme includes the definition of a model to establish how information will be extracted from the PAN band and how that information will be injected into the MS bands with low spatial resolution. The approach was applied to Spot 5 images where there are bands falling outside PAN’s spectrum. We propose an optional step in the quality evaluation protocol, which is to study the quality of the merger by regions, where each region represents a specific feature of the image. The results show that DT-CWT based approach offers good spatial quality while retaining the spectral information of original images, case SPOT 5. The additional step facilitates the identification of the most affected regions by the fusion process.
Resumo:
In Video over IP services, perceived video quality heavily depends on parameters such as video coding and network Quality of Service. This paper proposes a model for the estimation of perceived video quality in video streaming and broadcasting services that combines the aforementioned parameters with other that depend mainly on the information contents of the video sequences. These fitting parameters are derived from the Spatial and Temporal Information contents of the sequences. This model does not require reference to the original video sequence so it can be used for online, real-time monitoring of perceived video quality in Video over IP services. Furthermore, this paper proposes a measurement workbench designed to acquire both training data for model fitting and test data for model validation. Preliminary results show good correlation between measured and predicted values.
Resumo:
The paper proposes a model for estimation of perceived video quality in IPTV, taking as input both video coding and network Quality of Service parameters. It includes some fitting parameters that depend mainly on the information contents of the video sequences. A method to derive them from the Spatial and Temporal Information contents of the sequences is proposed. The model may be used for near real-time monitoring of IPTV video quality.
Resumo:
As the number of data sources publishing their data on the Web of Data is growing, we are experiencing an immense growth of the Linked Open Data cloud. The lack of control on the published sources, which could be untrustworthy or unreliable, along with their dynamic nature that often invalidates links and causes conflicts or other discrepancies, could lead to poor quality data. In order to judge data quality, a number of quality indicators have been proposed, coupled with quality metrics that quantify the “quality level” of a dataset. In addition to the above, some approaches address how to improve the quality of the datasets through a repair process that focuses on how to correct invalidities caused by constraint violations by either removing or adding triples. In this paper we argue that provenance is a critical factor that should be taken into account during repairs to ensure that the most reliable data is kept. Based on this idea, we propose quality metrics that take into account provenance and evaluate their applicability as repair guidelines in a particular data fusion setting.
Resumo:
When the fresh fruit reaches the final markets from the suppliers, its quality is not always as good as it should, either because it has been mishandled during transportation or because it lacks an adequate quality control at the producer level, before being shipped. This is why it is necessary for the final markets to establish their own quality assessment system if they want to ensure to their customers the quality they want to sell. In this work, a system to control fruit quality at the last level of the distribution channel has been designed. The system combines rapid control techniques with laboratory equipment and statistical sampling protocols, to obtain a dynamic, objective process, which can substitute advantageously the quality control inspections carried out visually by human experts at the reception platform of most hypermarkets. Portable measuring equipment have been chosen (firmness tester, temperature and humidity sensors...) as well as easy-to-use laboratory equipment (texturometer, colorimeter, refractometer..,) combining them to control the most important fruit quality parameters (firmness, colour, sugars, acids). A complete computer network has been designed to control all the processes and store the collected data in real time, and to perform the computations. The sampling methods have been also defined to guarantee the confidence of the results. Some of the advantages of a quality assessment system as the proposed one are: the minimisation of human subjectivity, the ability to use modern measuring techniques, and the possibility of using it also as a supplier's quality control system. It can be also a way to clarify the quality limits of fruits among members of the commercial channel, as well as the first step in the standardisation of quality control procedures.
Resumo:
The consumption of melon (Cucumis melo L.) has been, until several years ago, regional, seasonal and without commercial interest. Recent commercial changes and world wide transportation have changed this situation. Melons from 3 different ripeness stages at harvest and 7 cold storage periods have been analysed by destructive and non destructive tests. Chemical, physical, mechanical (non destructive impact, compression, skin puncture and Magness- Taylor) and sensory tests were carried out in order to select the best test to assess quality and to determine the optimal ripeness stage at harvest. Analysis of variance and Principal Component Analysis were performed to study the data. The mechanical properties based on non-destructive Impact and Compression can be used to monitor cold storage evolution. They can also be used at harvest to segregate the highest ripeness stage (41 days after anthesis DAA) in relation to less ripe stages (34 and 28 DAA).Only 34 and 41 DAA reach a sensory evaluation above 50 in a scale from 0-100.
Resumo:
In developing instrumentation for the measurement of fruit quality, there is the need for fast and non-destructive devices, based on sensors, to be installed on-line. In the case of some fruits, like peaches, post-harvest ripeness, which is closely related to high quality for the consumer, is a priority. During ripening, external appearance (colour) and internal mechanical (firmness) and chemical (sugars and acids) quality are main features that evolve rapidly from and unripe to a ripe (high quality) stage. When considering the evolution of fruit quality in this scheme, external colour and firmness are shown to evolve in a parallel pattern, if monitored from the time of harvest to full consumer ripeness ( Rood, 1957; Crisosto et al, 1995; Kader, 1996). The visible (VIS) reflectance spectrum is a fast and easy reference that can be used to estimate quality of peaches, if we could show it to be reliably correlated with peach ripening rate during postharvest (Genard et al. 1994; Moras, 1995; Delwiche and Baumgartner, 1983; Delwiche et al. 1987; Slaughter, 1995; Lleo et al., 1998). Taste, described as an expert acceptance score, improves with ripeness (firmness and colour evolution), when considering the fruits on the tree, and also post-harvest.
Resumo:
This paper gives an overview of three recent studies by the authors on the topic of 3D video Quality of Experience (QoE). Two of studies [1,2] investigated different psychological dimension that may be needed for describing 3D video QoE and the third the visibility and annoyance of crosstalk[3]. The results shows that the video quality scale could be sufficient for evaluating S3D video experience for coding and spatial resolution reduction distortions. It was also confirmed that with a more complex mixture of degradations more than one scale should be used to capture the QoE in these cases. The study found a linear relationship between the perceived crosstalk and the amount of crosstalk.