861 resultados para transit efficiency
Resumo:
Since industrialization and the formation of larger urban centers in the nineteenth century, pollution of the environment was always present in daily life in various ways, namely in the form of light. Light pollution can cause various consequences, both for humans and for their ecosystem, producing effects on environmental, social, economic and scientific level. In Portugal, the lighting is responsible for 3% of total electricity consumption, energy costs are in some cases more than 50% towards the costs incurred by municipalities with energy, checking-in recent years a trend similar to that improvement of illumination levels in the region (about 4 to 5% per year). Proper use of lighting brings many benefits both to the citizen and environment, since greater energy efficiency can contribute to reducing CO2 emissions, energy costs, as well as to decrease the use of resources not-renewable and/or contamination of renewable resources, which can occurs in the process of obtaining electricity. The present study has a main goal to analyze the illuminance levels associated to the public lighting of the village of Vialonga, Vila Franca de Xira (Portugal), to verify if it is efficient. The aim is also to relate the efficiency of street lighting with the existence of light pollution.
Resumo:
Instituto Politécnico do Porto. Instituto Superior de Contabilidade e Administração do Porto
Resumo:
In this abstract is presented an energy management system included in a SCADA system existent in a intelligent home. The system control the home energy resources according to the players definitions (electricity consumption and comfort levels), the electricity prices variation in real time mode and the DR events proposed by the aggregators.
Resumo:
Titanium films have been deposited on stainless steel metal sheets using dc magnetron sputtering technique at different substrate temperatures. The structure of the titanium films strongly depend on the substrate temperature. The titanium film deposited at the substrate temperature lower than 300 ◦C has a loose flat sheet grains structure and the titanium film prepared at the substrate temperature higher than 500 ◦C has a dense nubby grains structure. The DSSC assembled using stainless steel sheet coated with titanium film deposited at high substrate temperature has a low charge transfer resistance in the TiO2/Ti interface and results in a high conversion efficiency. The DSSC assembled using stainless steel sheet coated with titanium film deposited at temperature higher than 500 ◦C has higher conversion efficiency than that assembled using titanium metal sheet as the substrate. The maximum conversion efficiency, 2.26% is obtained for DSSC assembled using stainless steel sheet coated with titanium film deposited at 700 ◦C substrate temperature, which is about 70% of the conversion efficiency of the FTO reference cell used in this study.
Resumo:
Copyright © 2013 Springer Netherlands.
Resumo:
Copyright © 2013 Springer Netherlands.
Resumo:
Copyright © 2013 Springer Netherlands.
Resumo:
Copyright © 2013 Springer Netherlands.
Resumo:
Copyright 2013 Springer Netherlands.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The present work aims at evaluating the efficiency of an organic polymer from vegetal source used as coagulant for treating different types of industrial effluents. This coagulant (Flox-QT) is obtained from the Black Acacia (Acacia mearnsii). The effluents studied were produced in petrochemical, leather, cork stoppers, metalworking, olive oil, glue, paint (printing), textile and paper industries. The parameters analyzed in the effluents before and after treatment were selected according to the type of wastewater and included pH, conductivity, apparent colour, turbidity, total suspended solids (TSS), chemical oxygen demand (COD) and some metals. The coagulant proved to be efficient for almost all effluents tested. The best results were obtained for the paper industry wastewater, with 91% removal of chemical oxygen demand and 95% of total suspended solids removal. The estimated cost of this treatment would be only 0.24 Euro per cubic meter of treated effluent, only regarding the price of the coagulant and the required dosage. The use of this coagulant is also adequate for the valorisation of the sludge obtained, which in this case could be recycled for paper production.
Resumo:
The BALA project (Biodiversity of Arthropods of Laurisilva of the Azores) is a research initiative to quantify the spatial distribution of arthropod biodiversity in native forests of the Azores archipelago. Arthropods were collected using a combination of two techniques, targeting epigean (ground dwelling) and canopy (arboreal) arthropods: pitfall traps (with Turquin and Ethylene solutions) and beating samples (using the three most dominant plant species). A total of 109 transects distributed amongst 18 forest fragments in seven of the nine Azorean islands were used in this study. The performance of alternative sampling methods and effort were tested. No significant differences were found in the accumulated number of species captured whether an alternative method was used or whether another transect with similar effort was established in another location within the same fragment. A combination of Ethylene and Turquin traps captured more species per individual, Turquin and beating captured more species per sample, and Turquin captured more species per unit time. An optimization exercise was performed and we found that the protocol applied during recent years is very close to optimal, allowing its future replication with confidence. The minimum combinations of sampling effort and methods, in order to monitor or to inventory diversity, taking into account different proportions of sample completeness are discussed.
Resumo:
OBJECTIVE: The Integrated Management of Childhood Illness is a strategy designed to address major causes of child mortality. The aim of this study was to assess the impact of the strategy on the quality of child health care provided at primary facilities. METHODS: Child health quality of care and costs were compared in four states in Northeastern Brazil, in 2001. There were studied 48 health facilities considered to have had stable strategy implementation at least two years before the start of study, with 48 matched comparison facilities in the same states. A single measure of correct management of sick children was used to assess care provided to all sick children. Costs included all resources at the national, state, local and facility levels associated with child health care. RESULTS: Facilities providing strategy-based care had significantly better management of sick children at no additional cost to municipalities relative to the comparison municipalities. At strategy facilities 72% of children were correctly managed compared with 56% in comparison facilities (p=0.001). The cost per child managed correctly was US$13.20 versus US$21.05 in the strategy and comparison municipalities, respectively, after standardization for population size. CONCLUSIONS: The strategy improves the efficiency of primary facilities in Northeastern Brazil. It leads to better health outcomes at no extra cost.
Resumo:
Abstract This work reports the analysis of the efficiency and time of soil remediation using vapour extraction as well as provides comparison of results using both, prepared and real soils. The main objectives were: (i) to analyse the efficiency and time of remediation according to the water and natural organic matter content of the soil; and (ii) to assess if a previous study, performed using prepared soils, could help to preview the process viability in real conditions. For sandy soils with negligible clay content, artificially contaminated with cyclohexane before vapour extraction, it was concluded that (i) the increase of soil water content and mainly of natural organic matter content influenced negatively the remediation process, making it less efficient, more time consuming, and consequently more expensive; and (ii) a previous study using prepared soils of similar characteristics has proven helpful for previewing the process viability in real conditions.
Resumo:
TiO2 nanorod films have been deposited on ITO substrates by dc reactive magnetron sputtering technique. The structures of these nanorod films were modified by the variation of the oxygen pressure during the sputtering process. Although all these TiO2 nanorod films deposited at different oxygen pressures show an anatase structure, the orientation of the nanorod films varies with the oxygen pressure. Only a very weak (101) diffraction peak can be observed for the TiO2 nanorod film prepared at low oxygen pressure. However, as the oxygen pressure is increased, the (220) diffraction peak appears and the intensity of this diffraction peak is increased with the oxygen pressure. The results of the SEM show that these TiO2 nanorods are perpendicular to the ITO substrate. At low oxygen pressure, these sputtered TiO2 nanorods stick together and have a dense structure. As the oxygen pressure is increased, these sputtered TiO2 nanorods get separated gradually and have a porous structure. The optical transmittance of these TiO2 nanorod films has been measured and then fitted by OJL model. The porosities of the TiO2 nanorod films have been calculated. The TiO2 nanorod film prepared at high oxygen pressure shows a high porosity. The dye-sensitized solar cells (DSSCs) have been assembled using these TiO2 nanorod films prepared at different oxygen pressures as photoelectrode. The optimum performance was achieved for the DSSC using the TiO2 nanorod film with the highest (220) diffraction peak and the highest porosity.