983 resultados para titration
Resumo:
In the initial stage of this work, two potentiometric methods were used to determine the salt (sodium chloride) content in bread and dough samples from several cities in the north of Portugal. A reference method (potentiometric precipitation titration) and a newly developed ion-selective chloride electrode (ISE) were applied. Both methods determine the sodium chloride content through the quantification of chloride. To evaluate the accuracy of the ISE, bread and respective dough samples were analyzed by both methods. Statistical analysis (0.05 significance level) indicated that the results of these methods did not differ significantly. Therefore the ISE is an adequate alternative for the determination of chloride in the analyzed samples. To compare the results of these chloride-based methods with a sodium-based method, sodium was quantified in the same samples by a reference method (atomic absorption spectrometry). Significant differences between the results were verified. In several cases the sodium chloride content exceeded the legal limit when the chloride-based methods were used, but when the sodium-based method was applied this was not the case. This could lead to the erroneous application of fines and therefore the authorities should supply additional information regarding the analytical procedure for this particular control.
Resumo:
Eur. J. Biochem. 271, 2361–2369 (2004)
Resumo:
FEBS Letters 579 (2005) 4585–4590
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química
Resumo:
In the present work the immune adherence hemagglutination test (IAHA) was standardized in a simplified procedure. This test showed good reproducibility, better than the classical mice serum neutralization test (SN). The tests showed high correlation degree: high titers in one test corresponded to high titers in the other one, and the same occured with low titers. The IAHA test is extremely simple, fast to perform, and of low cost when compared to tests such as SN or indirect immunofluorescense (IIF). It also proved to be useful in less sophisticated laboratories or even as a screening test for the titration of rabies antibodies.
Resumo:
Toluene hydrogenation was studied over catalysts based on Pt supported on large pore zeolites (HUSY and HBEA) with different metal/acid ratios. Acidity of zeolites was assessed by pyridine adsorption followed by FTIR showing only small changes before and after Pt introduction. Metal dispersion was determined by H2–O2 titration and verified by a linear correlation with the intensity of Pt0–CO band obtained by in situ FTIR. It was also observed that the electronic properties of Pt0 clusters were similar for the different catalysts. Catalytic tests showed rapid catalyst deactivation with an activity loss of 80–95% after 60 min of reaction. The turnover frequency of fresh catalysts depended both on metal dispersion and the support. For the same support, it changed by a 1.7-fold (HBEA) and 4.0-fold (HUSY) showing that toluene hydrogenation is structure-sensitive, i.e. hydrogenating activity is not a unique function of accessible metal. This was proposed to be due to the contribution to the overall activity of the hydrogenation of adsorbed toluene on acid sites via hydrogen spillover. Taking into account the role of zeolite acidity, the catalysts series were compared by the activity per total adsorbing sites which was observed to increase steadily with nPt/(nPt + nA). An increase of the accessible Pt atoms leads to an increase on the amount of spilled over hydrogen available in acid sites therefore increasing the overall activity. Pt/HBEA catalysts were found to be more active per total adsorbing site than Pt/HUSY which is proposed to be due to an augmentation in the efficiency of spilled over hydrogen diffusion related to the proximity between Pt clusters and acid sites. The intervention of Lewis acid sites in a greater extent than that measured by pyridine adsorption may also contribute to this higher activity of Pt/HBEA catalysts. These results reinforce the importance of model reactions as a closer perspective to the relevant catalyst properties in reaction conditions.
Resumo:
The study evaluated six Plasmodium falciparum antigen extracts to be used in the IgG and IgM enzyme-linked immunosorbent assays (ELISA), for malaria diagnosis and epidemiological studies. Results obtained with eighteen positive and nine negative control sera indicated that there were statistically significant differences among these antigen extracts (Multifactor ANOVA, p< 0.0001). Urea, sodium deoxycholate and Zwittergent antigen extracts performed better than did the three others, their features being very similar for the detection of IgG antibodies. Urea, alkaline and sodium deoxycholate antigen extracts proved to be better than the others for the detection of IgM antibodies. A straight line relationship was found between the optical densities (or their respective log 10) and the log 10 of antibody dilutions, with a very constant slope. Thus serum titers could be determined by direct titration and by two different equations, needing only one serum dilution. For IgM antibody detections, log 10 expression gave results that better correlated with direct titration (95% Bonferroni). For IgG antibody detections, the titer differences were not significant. The reproducibility of antibody titers and antigen batches was also evaluated, giving satisfactory results.
Resumo:
A Dot enzyme-linked immunosorbent assay (Dot-ELISA) was standardized and evaluated for the serodiagnosis of human toxoplasmosis. Out of 538 serum samples tested by the immunofluorescence test for toxoplasmosis (IFAT-IgG) as reference test, 183 (34%) were positive at cut off 1:16 and 192 (36%) were positive for Dot-ELISA-IgG at cut-off 1:256. For Dot-ELISA, co-positivity was 0.94, co-negativity 0.94 and concordance 0.88 in relation to IFAT-IgG. These results suggest the usefulness of Dot-ELISA (cut-off titer of 1:256) for the serodiagnosis of human toxoplasmosis. The main advantage of this technique is simplicity, positive test can be visually identified (colored precipitate). It does not require a special equipment and it can be used as a qualitative test to screen large numbers of samples or as a quantitative assay to determine end-point titration of individual sera.
Resumo:
The authors report the clinical, laboratorial and epidemiological aspects of a human case of jungle yellow fever. The patient suffered from fever, chills, sweating, headaches, backaches, myalgia, epigastric pains, nausea, vomiting, diarrhea and prostration. He was unvaccinated and had been working in areas where cases of jungle yellow fever had been confirmed. Investigations concerning the yellow fever virus were performed. Blood samples were collected on several days in the course of the illness. Three of these samples (those obtained on days 5,7 and 10) were inoculated into suckling mice in attempt to isolate virus and to titrate the viremia level. Serological surveys were carried out by using the IgM Antibodies Capture Enzyme Linked Immunosorbent Assay (MAC-ELISA), Complement Fixation (CF), Hemagglulinalion Inhibition (HI) and Neutralization (N) tests. The yellow fever virus, recovered from the two first samples and the virus titration, showed high level of viremia. After that, specific antibodies appeared in all samples. The interval between the end of the viremia and the appearance of the antibodies was associated with the worsening of clinical symptoms, including bleeding of the mucous membrane. One must be aware of the risk of having a urban epidemics in areas where Aedes aegypti is found in high infestation indexes.
Resumo:
Dissertação de Mestrado em Solicitadoria
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em BioOrgânica
Resumo:
Dissertação apresentada para a obtenção do Grau de Mestre em Genética Molecular e Biomedicina, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia
Resumo:
Toxoplasmosis is one of the most common zoonoses worldwide. The seroprevalence for T. gondii in human population from Brazil might range from 40 to 80%. The aim of this paper was to study the seroprevalence of T. gondii infection in children from age one to 15 living in a low socioeconomic community, named community of Jardim São Remo in the year of 2002. The community is located in the West area of São Paulo municipality, São Paulo State, Brazil. Antibodies to T. gondii were found in 110 (32.4%, CI 95%: 27.5 - 37.7) of the 339 children tested with indirect immunofluorescent antibody test. The titration of the samples revealed 29 children with serum titer equal to 16, 14 children with 32, 18 children with 64, 21 children with 128, 20 children with 256 and eight children with serum titer > 512. The age dependence of the prevalence of T. gondii infection and the association between seroprevalence for T. gondii and seroprevalence for T. canis suggest that the infection is chiefly postnatal. Seroconversion in infant population of community Jardim São Remo occurs in children as young as two years old, earlier than in the children attended at health centers of São Paulo city. The seroprevalence of T. gondii in children from Jardim São Remo was compared to the prevalence in children from other urban centers of Brazil.
Resumo:
Inorganic Chemistry 50(21):10600-7
Resumo:
J Biol Inorg Chem. 2008 Jun;13(5):737-53. doi: 10.1007/s00775-008-0359-6