926 resultados para solar air-conditioning


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Trabalho Final de mestrado para obtenção do grau de Mestre em Engenharia Civil

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Bahrain International Circuit (BIC) and complex, at latitude 26.00N and longitude 51.54E, was built in 483 days and cost 150 million US$. The circuit consists of six different individual tracks with a 3.66 km outer track (involving 10 turns) and a 2.55 km inner track (having six turns). The complex has been designed to host a variety of other sporting activities. Fifty thousand spectators, including 10,500 in the main grandstand, can be accommodated simultaneously. State-of-the art on-site media and broadcast facilities are available. The noise level emitted from vehicles on the circuit during the Formula-1 event, on April 4th 2004, was acceptable and caused no physical disturbance to the fans in the VIP lounges or to scholars studying at the University of Bahrain's Shakeir Campus, which is only 1.5 km away from the circuit. The sound-intensity level (SIL) recorded on the balcony of the VIP lounge was 128 dB(A) and was 80 dB(A) inside the lounge. The calculated SIL immediately outside the lecture halls of the University of Bahrain was 70 dB(A) and 65 dB(A) within them. Thus racing at BIC can proceed without significantly disturbing the academic-learning process. The purchased electricity demand by the BIC complex peaked (at 4.5 MW) during the first Formula-1 event on April 4th 2004. The reverse-osmosis (RO) plant at the BIC provides 1000 m(3) of desalinated water per day for landscape irrigation. Renewable-energy inputs, (i.e., via solar and wind power), at the BIC could be harnessed to generate electricity for water desalination, air conditioning, lighting as well as for irrigation. If the covering of the BIC complex was covered by adhesively fixed modern photovoltaic cells, then similar to 1.2 MW of solar electricity could be generated. If two horizontal-axis, at 150 m height above the ground, three 75m bladed, wind turbines were to be installed at the BIC, then the output could reach 4 MW. Furthermore, if 10,000 Jojoba trees (a species renowned for having a low demand for water, needing only five irrigations per year in Bahrain and which remain green throughout the year) are planted near the circuit, then the local micro-climate would be improved with respect to human comfort as well as the local environment becoming cleaner.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Cool materials are characterized by having a high solar reflectance r – which is able to reduce heat gains during daytime - and a high thermal emissivity ε that enables them to dissipate the heat absorbed throughout the day during night. Despite the concept of cool roofs - i.e. the application of cool materials to roof surfaces - is well known in US since 1990s, many studies focused on their performance in both residential and commercial sectors under various climatic conditions for US countries, while only a few case studies are analyzed in EU countries. The present work aims at analyzing the thermal benefits due to their application to existing office buildings located in EU countries. Indeed, due to their weight in the existing buildings stock, as well as the very low rate of new buildings construction, the retrofit of office buildings is a topic of great concern worldwide. After an in-depth characterization of the existing buildings stock in the EU, the book gives an insight into roof energy balance due to different technological solutions, showing in which cases and to what extent cool roofs are preferable. A detailed description of the physical properties of cool materials and their availability on the market provides a solid background for the parametric analysis carried out by means of detailed numerical models that aims at evaluating cool roofs performance for various climates and office buildings configurations. With the help of dynamic simulations, the thermal behavior of representative office buildings of the existing EU buildings stock is assessed in terms of thermal comfort and energy needs for air conditioning. The results, which consider several variations of building features that may affect the resulting energy balance, show how cool roofs are an effective strategy for reducing overheating occurrences and thus improving thermal comfort in any climate. On the other hand, potential heating penalties due to a reduction in the incoming heat fluxes through the roof are taken into account, as well as the aging process of cool materials. Finally, an economic analysis of the best performing models shows the boundaries for their economic convenience.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this thesis, one of the current control algorithms for the R744 cycle, which tries tooptimize the performance of the system by two SISO control loops, is compared to acost-effective system with just one actuator. The operation of a key component of thissystem, a two stage orifice expansion valve is examined in a range of typical climateconditions. One alternative control loop for this system, which has been proposed byBehr group, is also scrutinized.The simulation results affirm the preference of using two control-loops instead of oneloop, but refute advantages of the Behr alternate control approach against one-loopcontrol. As far as the economic considerations of the A/C unit are concerned, usinga two-stage orifice expansion valve is desired by the automotive industry, thus basedon the experiment results, an improved logic for control of this system is proposed.In the second part, it is investigated whether the one-actuator control approach isapplicable to a system consisting of two parallel evaporators to allow passengers tocontrol different climate zones. The simulation results show that in the case of usinga two-stage orifice valve for the front evaporator and a fixed expansion valve forthe rear one, a proper distribution of the cooling power between the front and rearcompartment is possible for a broad range of climate conditions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The term refrigeration solar refers to any air conditioning system that uses solar energy as a primary energy source. The use of solar radiation for cooling purposes is divided according to their technological possibilities which are distinguished from one another as the way that energy is involved in the cycle, work or heat. The first case is related to vapor compression cycles, in which the work input is provided by the photovoltaic conversion of solar energy into electrical energy. In the second case, an absorption refrigeration cycle is used and the thermal energy collected from the solar radiation is provided at the generator of this cycle.. In this work a system with an absorption cycle using the pair BrLi-water, using solar energy as input is modeled. It is considered a simple refrigeration cycle whose the equations of mass and energy conservation in each component are developed in order to obtain an algebraic equation set and a simulation routine using the EES software. Although the simulation operates under certain specified thermal load it is possible to estimate the necessary areas of heat exchangers and solar collectors

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Air conditioning and lighting costs can be reduced substantially by changing the optical properties of "intelligent windows." The electrochromic devices studied to date have used copper as an additive. Copper, used here as an electrochromic material, was dissolved in an aqueous animal protein-derived gel electrolyte. This combination constitutes the electrochromic system for reversible electrodeposition. Cyclic voltammetry, chronoamperometric and chromogenic analyses indicated that were obtained good conditions of transparency (initial transmittance of 70%), optical reversibility, small potential window (2.1 V), variation of transmittance in visible light (63.6%) and near infrared (20%) spectral regions. Permanence in the darkened state was achieved by maintaining a lower pulse potential (-0.16 V) than the deposition potential (-1.0 V). Increasing the number of deposition and dissolution cycles favored the transmittance and photoelectrochemical reversibility of the device. The conductivity of the electrolyte (10(-3) S/cm) at several concentrations of CuCl2 was determined by electrochemical impedance spectroscopy. A thermogravimetric analysis confirmed the good thermal stability of the electrolyte, since the mass loss detected up to 100 degrees C corresponded to water evaporation and decomposition of the gel started only at 200 degrees C. Micrographic and small angle X-ray scattering analyses indicated the formation of a persistent deposit of copper particles on the ITO. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Indoor Air Quality (IAQ) can have significant implications for health, productivity, job performance, and operating cost. Professional experience in the field of indoor air quality suggests that high expectations (better than nationally established standards) (American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE)) of workplace indoor air quality lead to increase air quality complaints. To determine whether there is a positive association between expectations and indoor air quality complaints, a one-time descriptive and analytical cross-sectional pilot study was conducted. Area Safety Liaisons (n = 330) at University of Texas Health Science Center – Houston were asked to answer a questionnaire regarding their expectations of four workplace indoor air quality indicators i.e., (temperature, relative humidity, carbon dioxide, and carbon monoxide) and if they experienced and reported indoor air quality problems. A chi-square test for independence was used to evaluate associations among the variables of interest. The response rate was 54% (n = 177). Results did not show significant associations between expectation and indoor air quality. However, a greater proportion of Area Safety Liaisons who expected indoor air quality indicators to be better than the established standard experienced greater indoor air quality problems. Similarly, a slightly higher proportion of Area Liaisons who expected indoor air quality indicators to be better than the standard reported greater indoor air quality complaints. ^ The findings indicated that a greater proportion of Area Safety Liaisons with high expectations (conditions that are beyond what is considered normal and acceptable by ASHRAE) experienced greater indoor air quality discomfort. This result suggests a positive association between high expectations and experienced and reported indoor air quality complaints. Future studies may be able to address whether the frequency of complaints and resulting investigations can be reduced through information and education about what are acceptable conditions.^

Relevância:

90.00% 90.00%

Publicador:

Resumo:

La presente Tesis Doctoral evalúa la contribución de una fachada activa, constituida por acristalamientos con circulación de agua, en el rendimiento energético del edificio. Con especial énfasis en la baja afección sobre su imagen, su integración ha de favorecer la calificación del edificio con el futuro estándar de Edificio de consumo de Energía Casi Nulo (EECN). El propósito consiste en cuantificar su aportación a limitar la demanda de climatización, como solución de fachada transparente acorde a las normas de la energía del 2020. En el primer capítulo se introduce el planteamiento del problema. En el segundo capítulo se desarrollan la hipótesis y el objetivo fundamental de la investigación. Para tal fin, en el tercer capítulo, se revisa el estado del arte de la tecnología y de la investigación científica, mediante el análisis de la literatura de referencia. Se comparan patentes, prototipos, sistemas comerciales asimilables, investigaciones en curso en Universidades, y proyectos de investigación y desarrollo, sobre envolventes que incorporan acristalamientos con circulación de agua. El método experimental, expuesto en el cuarto capítulo, acomete el diseño, la fabricación y la monitorización de un prototipo expuesto, durante ciclos de ensayos, a las condiciones climáticas de Madrid. Esta fase ha permitido adquirir información precisa sobre el rendimiento del acristalamiento en cada orientación de incidencia solar, en las distintas estaciones del año. En paralelo, se aborda el desarrollo de modelos teóricos que, mediante su asimilación a soluciones multicapa caracterizadas en las herramientas de simulación EnergyPlus y IDA-ICE (IDA Indoor Climate and Energy), reproducen el efecto experimental. En el quinto capítulo se discuten los resultados experimentales y teóricos, y se analiza la respuesta del acristalamiento asociado a un determinado volumen y temperatura del agua. Se calcula la eficiencia en la captación de la radiación y, mediante la comparativa con un acristalamiento convencional, se determina la reducción de las ganancias solares y las pérdidas de energía. Se comparan el rendimiento del acristalamiento, obtenido experimentalmente, con el ofrecido por paneles solares fototérmicos disponibles en el mercado. Mediante la traslación de los resultados experimentales a casos de células de tamaño habitable, se cuantifica la afección del acristalamiento sobre el consumo en refrigeración y calefacción. Diferenciando cada caso por su composición constructiva y orientación, se extraen conclusiones sobre la reducción del gasto en climatización, en condiciones de bienestar. Posteriormente, se evalúa el ahorro de su incorporación en un recinto existente, de construcción ligera, localizado en la Escuela de Arquitectura de la Universidad Politécnica de Madrid (UPM). Mediante el planteamiento de escenarios de rehabilitación energética, se estima su compatibilidad con un sistema de climatización mediante bomba de calor y extracción geotérmica. Se describe el funcionamiento del sistema, desde la perspectiva de la operación conjunta de los acristalamientos activos e intercambio geotérmico, en nuestro clima. Mediante la parametrización de sus funciones, se estima el beneficio adicional de su integración, a partir de la mejora del rendimiento de la bomba de calor COP (Coefficient of Performance) en calefacción, y de la eficiencia EER (Energy Efficiency Ratio) en refrigeración. En el recinto de la ETSAM, se ha analizado la contribución de la fachada activa en su calificación como Edificio de Energía Casi Nula, y estudiado la rentabilidad económica del sistema. En el sexto capítulo se exponen las conclusiones de la investigación. A la fecha, el sistema supone alta inversión inicial, no obstante, genera elevada eficiencia con bajo impacto arquitectónico, reduciéndose los costes operativos, y el dimensionado de los sistemas de producción, de mayor afección sobre el edificio. Mediante la envolvente activa con suministro geotérmico no se condena la superficie de cubierta, no se ocupa volumen útil por la presencia de equipos emisores, y no se reduce la superficie o altura útil a base de reforzar los aislamientos. Tras su discusión, se considera una alternativa de valor en procesos de diseño y construcción de Edificios de Energía Casi Nulo. Se proponen líneas de futuras investigación cuyo propósito sea el conocimiento de la tecnología de los acristalamientos activos. En el último capítulo se presentan las actividades de difusión de la investigación. Adicionalmente se ha proporcionado una mejora tecnológica a las fachadas activas existentes, que ha derivado en la solicitud de una patente, actualmente en tramitación. ABSTRACT This Thesis evaluates the contribution of an active water flow glazing façade on the energy performance of buildings. Special emphasis is made on the low visual impact on its image, and the active glazing implementation has to encourage the qualification of the building with the future standard of Nearly Zero Energy Building (nZEB). The purpose is to quantify the façade system contribution to limit air conditioning demand, resulting in a transparent façade solution according to the 2020 energy legislation. An initial approach to the problem is presented in first chapter. The second chapter develops the hypothesis and the main objective of the research. To achieve this purpose, the third chapter reviews the state of the art of the technology and scientific research, through the analysis of reference literature. Patents, prototypes, assimilable commercial systems, ongoing research in other universities, and finally research and development projects incorporating active fluid flow glazing are compared. The experimental method, presented in fourth chapter, undertakes the design, manufacture and monitoring of a water flow glazing prototype exposed during test cycles to weather conditions in Madrid. This phase allowed the acquisition of accurate information on the performance of water flow glazing on each orientation of solar incidence, during different seasons. In parallel, the development of theoretical models is addressed which, through the assimilation to multilayer solutions characterized in the simulation tools EnergyPlus and IDA-Indoor Climate and Energy, reproduce the experimental effect. Fifth chapter discusses experimental and theoretical results focused to the analysis of the active glazing behavior, associated with a specific volume and water flow temperature. The efficiency on harvesting incident solar radiation is calculated, and, by comparison with a conventional glazing, the reduction of solar gains and energy losses are determined. The experimental performance of fluid flow glazing against the one offered by photothermal solar panels available on the market are compared. By translating the experimental and theoretical results to cases of full-size cells, the reduction in cooling and heating consumption achieved by active fluid glazing is quantified. The reduction of energy costs to achieve comfort conditions is calculated, differentiating each case by its whole construction composition and orientation. Subsequently, the saving of the implementation of the system on an existing lightweight construction enclosure, located in the School of Architecture at the Polytechnic University of Madrid (UPM), is then calculated. The compatibility between the active fluid flow glazing and a heat pump with geothermal heat supply system is estimated through the approach of different energy renovation scenarios. The overall system operation is described, from the perspective of active glazing and geothermal heat exchange combined operation, in our climate. By parameterization of its functions, the added benefit of its integration it is discussed, particularly from the improvement of the heat pump performance COP (Coefficient of Performance) in heating and efficiency EER (Energy Efficiency Ratio) in cooling. In the case study of the enclosure in the School of Architecture, the contribution of the active glazing façade in qualifying the enclosure as nearly Zero Energy Building has been analyzed, and the feasibility and profitability of the system are studied. The sixth chapter sets the conclusions of the investigation. To date, the system may require high initial investment; however, high efficiency with low architectural impact is generated. Operational costs are highly reduced as well as the size and complexity of the energy production systems, which normally have huge visual impact on buildings. By the active façade with geothermal supply, the deck area it is not condemned. Useful volume is not consumed by the presence of air-conditioning equipment. Useful surface and room height are not reduced by insulation reinforcement. After discussion, water flow glazing is considered a potential value alternative in nZEB design and construction processes. Finally, this chapter proposes future research lines aiming to increase the knowledge of active water flow glazing technology. The last chapter presents research dissemination activities. Additionally, a technological improvement to existing active facades has been developed, which has resulted in a patent application, currently in handling process.