955 resultados para signal-to-noise-ratio (SNR)
Resumo:
The increasing demand for high performance wireless communication systems has shown the inefficiency of the current model of fixed allocation of the radio spectrum. In this context, cognitive radio appears as a more efficient alternative, by providing opportunistic spectrum access, with the maximum bandwidth possible. To ensure these requirements, it is necessary that the transmitter identify opportunities for transmission and the receiver recognizes the parameters defined for the communication signal. The techniques that use cyclostationary analysis can be applied to problems in either spectrum sensing and modulation classification, even in low signal-to-noise ratio (SNR) environments. However, despite the robustness, one of the main disadvantages of cyclostationarity is the high computational cost for calculating its functions. This work proposes efficient architectures for obtaining cyclostationary features to be employed in either spectrum sensing and automatic modulation classification (AMC). In the context of spectrum sensing, a parallelized algorithm for extracting cyclostationary features of communication signals is presented. The performance of this features extractor parallelization is evaluated by speedup and parallel eficiency metrics. The architecture for spectrum sensing is analyzed for several configuration of false alarm probability, SNR levels and observation time for BPSK and QPSK modulations. In the context of AMC, the reduced alpha-profile is proposed as as a cyclostationary signature calculated for a reduced cyclic frequencies set. This signature is validated by a modulation classification architecture based on pattern matching. The architecture for AMC is investigated for correct classification rates of AM, BPSK, QPSK, MSK and FSK modulations, considering several scenarios of observation length and SNR levels. The numerical results of performance obtained in this work show the eficiency of the proposed architectures
Resumo:
Recently, genetically encoded optical indicators have emerged as noninvasive tools of high spatial and temporal resolution utilized to monitor the activity of individual neurons and specific neuronal populations. The increasing number of new optogenetic indicators, together with the absence of comparisons under identical conditions, has generated difficulty in choosing the most appropriate protein, depending on the experimental design. Therefore, the purpose of our study was to compare three recently developed reporter proteins: the calcium indicators GCaMP3 and R-GECO1, and the voltage indicator VSFP butterfly1.2. These probes were expressed in hippocampal neurons in culture, which were subjected to patchclamp recordings and optical imaging. The three groups (each one expressing a protein) exhibited similar values of membrane potential (in mV, GCaMP3: -56 ±8.0, R-GECO1: -57 ±2.5; VSFP: -60 ±3.9, p = 0.86); however, the group of neurons expressing VSFP showed a lower average of input resistance than the other groups (in Mohms, GCaMP3: 161 ±18.3; GECO1-R: 128 ±15.3; VSFP: 94 ±14.0, p = 0.02). Each neuron was submitted to current injections at different frequencies (10 Hz, 5 Hz, 3 Hz, 1.5 Hz, and 0.7 Hz) and their fluorescence responses were recorded in time. In our study, only 26.7% (4/15) of the neurons expressing VSFP showed detectable fluorescence signal in response to action potentials (APs). The average signal-to-noise ratio (SNR) obtained in response to five spikes (at 10 Hz) was small (1.3 ± 0.21), however the rapid kinetics of the VSFP allowed discrimination of APs as individual peaks, with detection of 53% of the evoked APs. Frequencies below 5 Hz and subthreshold signals were undetectable due to high noise. On the other hand, calcium indicators showed the greatest change in fluorescence following the same protocol (five APs at 10 Hz). Among the GCaMP3 expressing neurons, 80% (8/10) exhibited signal, with an average SNR value of 21 ±6.69 (soma), while for the R-GECO1 neurons, 50% (2/4) of the neurons had signal, with a mean SNR value of 52 ±19.7 (soma). For protocols at 10 Hz, 54% of the evoked APs were detected with GCaMP3 and 85% with R-GECO1. APs were detectable in all the analyzed frequencies and fluorescence signals were detected from subthreshold depolarizations as well. Because GCaMP3 is the most likely to yield fluorescence signal and with high SNR, some experiments were performed only with this probe. We demonstrate that GCaMP3 is effective in detecting synaptic inputs (involving Ca2+ influx), with high spatial and temporal resolution. Differences were also observed between the SNR values resulting from evoked APs, compared to spontaneous APs. In recordings of groups of cells, GCaMP3 showed clear discrimination between activated and silent cells, and reveals itself as a potential tool in studies of neuronal synchronization. Thus, our results indicate that the presently available calcium indicators allow detailed studies on neuronal communication, ranging from individual dendritic spines to the investigation of events of synchrony in neuronal networks genetically defined. In contrast, studies employing VSFPs represent a promising technology for monitoring neural activity and, although still to be improved, they may become more appropriate than calcium indicators, since neurons work on a time scale faster than events of calcium may foresee
Resumo:
The multipath effect affects the differential and relative positioning, even that one involving short baselines. So it is necessary to detect this effect, check the caused error level, and mainly, its removal. This paper aims at analysing and comparing some useful components in the detection of this effect. These components are the Signal to Noise Ratio (SNR), the values of MP1 and MP2 obtained from the TEQC software that indicates the multipath level in the carriers L1 and L2, the multipath repeatability in consecutive days and the elevation angle and the azimuth of the satellites. For this purpose, an experiment is carried out, comparing such components in the presence and the absence of reflector objects that cause the multipath. Not only there is clear multipath repeatability in the residuals, but it also appears in the measures SNR, MP1 and MP2, reaching up 99% of correlation. For reduction, at least, of the high frequency multipath effect, the Multi-Resolution Analysis using wavelets is applied in the double differences (DD) measures. Some statistical tests were accomplished, which indicate results improvement, and mainly, larger reliability in the solution of the ambiguities, reaching up 49% of improvement concerning the Ratio test without applying the proposed method.
Resumo:
An analysis of the active pixel sensor (APS), considering the doping profiles of the photodiode in an APS fabricated in a 0.18 μm standard CMOS technology, is presented. A simple and accurate model for the junction capacitance of the photodiode is proposed. An analytic expression for the output voltage of the APS obtained with this capacitance model is in good agreement with measurements and is more accurate than the models used previously. A different mode of operation for the APS based on the dc level of the output is suggested. This new mode has better low-light-level sensitivity than the conventional APS operating mode, and it has a slower temporal response to the change of the incident light power. At 1μW/cm2 and lower levels of light, the measured signal-to-noise ratio (SNR) of this new mode is more than 10 dB higher than the SNR of previously reported APS circuits. Also, with an output SNR of about 10 dB, the proposed dc level is capable of detecting light powers as low as 20 nW/cm2, which is about 30 times lower than the light power detected in recent reports by other groups. © 2007 IEEE.
Resumo:
Our main purpose in this study was to quantify biological tissue in computed tomography (CT) examinations with the aim of developing a skull and a chest patient equivalent phantom (PEP), both specific to infants, aged between 1 and 5 years old. This type of phantom is widely used in the development of optimization procedures for radiographic techniques, especially in computed radiography (CR) systems. In order to classify and quantify the biological tissue, we used a computational algorithm developed in Matlab (R). The algorithm performed a histogram of each CT slice followed by a Gaussian fitting of each tissue type. The algorithm determined the mean thickness for the biological tissues (bone, soft, fat, and lung) and also converted them into the corresponding thicknesses of the simulator material (aluminum, PMMA, and air). We retrospectively analyzed 148 CT examinations of infant patients, 56 for skull exams and 92 were for chest. The results provided sufficient data to construct a phantom to simulate the infant chest and skull in the posterior anterior or anterior posterior (PA/AP) view. Both patient equivalent phantoms developed in this study can be used to assess physical variables such as noise power spectrum (NPS) and signal to noise ratio (SNR) or perform dosimetric control specific to pediatric protocols.
Resumo:
Since discovery, computed tomography is a widely used diagnostic modality. However, this modality imparts relatively high doses to the patients and with fast technological advancement, it is necessary optimize the doses used and ensure the quality of the images through a quality assurance program. This work intended to compare Computed Tomography Dose Index (CTDIW) and effective dose with components of image quality: the Contrast-to-Noise Ratio (CNR) and Signal-to-Noise Ratio (SNR), and a quality factor (Q) deduced by the Rose model for two groups of computed tomography units. The first group was composed by equipments with 10 up to 16 slices and the second one presented 40 up to 320 slices detectors, for the protocols of head and abdomen. It was realized a comparison between different selectable parameters in the protocol of a Philips Brilliance 16, too. The results of the first group to CTDIW, effective dose, SNR and CNR showed variations of 28%, 33%, 37% and 32% respectively for head protocol, and 21%, 27%, 43% and 37% respectively for abdomen protocol. The results of the group 2 to CTDIW, effective dose, SNR and CNR showed variations of 15%, 26%, 36% and 34% respectively for the head protocol, and 8%, 13%, 50% and 60% respectively for abdomen protocol. The comparison between both groups demonstrated similar levels of doses impartation to patients though having so many different configurations, if the uncertainties associated with this measurement were considered. The results of the comparison between different parameters in the Philips Brilliance 16 scanner were in agreement with expected
Resumo:
The study proposes a constrained least square (CLS) pre-distortion scheme for multiple-input single-output (MISO) multiple access ultra-wideband (UWB) systems. In such a scheme, a simple objective function is defined, which can be efficiently solved by a gradient-based algorithm. For the performance evaluation, scenarios CM1 and CM3 of the IEEE 802.15.3a channel model are considered. Results show that the CLS algorithm has a fast convergence and a good trade-off between intersymbol interference (ISI) and multiple access interference (MAI) reduction and signal-to-noise ratio (SNR) preservation, performing better than time-reversal (TR) pre-distortion.
Resumo:
Since the first underground nuclear explosion, carried out in 1958, the analysis of seismic signals generated by these sources has allowed seismologists to refine the travel times of seismic waves through the Earth and to verify the accuracy of the location algorithms (the ground truth for these sources was often known). Long international negotiates have been devoted to limit the proliferation and testing of nuclear weapons. In particular the Treaty for the comprehensive nuclear test ban (CTBT), was opened to signatures in 1996, though, even if it has been signed by 178 States, has not yet entered into force, The Treaty underlines the fundamental role of the seismological observations to verify its compliance, by detecting and locating seismic events, and identifying the nature of their sources. A precise definition of the hypocentral parameters represents the first step to discriminate whether a given seismic event is natural or not. In case that a specific event is retained suspicious by the majority of the State Parties, the Treaty contains provisions for conducting an on-site inspection (OSI) in the area surrounding the epicenter of the event, located through the International Monitoring System (IMS) of the CTBT Organization. An OSI is supposed to include the use of passive seismic techniques in the area of the suspected clandestine underground nuclear test. In fact, high quality seismological systems are thought to be capable to detect and locate very weak aftershocks triggered by underground nuclear explosions in the first days or weeks following the test. This PhD thesis deals with the development of two different seismic location techniques: the first one, known as the double difference joint hypocenter determination (DDJHD) technique, is aimed at locating closely spaced events at a global scale. The locations obtained by this method are characterized by a high relative accuracy, although the absolute location of the whole cluster remains uncertain. We eliminate this problem introducing a priori information: the known location of a selected event. The second technique concerns the reliable estimates of back azimuth and apparent velocity of seismic waves from local events of very low magnitude recorded by a trypartite array at a very local scale. For the two above-mentioned techniques, we have used the crosscorrelation technique among digital waveforms in order to minimize the errors linked with incorrect phase picking. The cross-correlation method relies on the similarity between waveforms of a pair of events at the same station, at the global scale, and on the similarity between waveforms of the same event at two different sensors of the try-partite array, at the local scale. After preliminary tests on the reliability of our location techniques based on simulations, we have applied both methodologies to real seismic events. The DDJHD technique has been applied to a seismic sequence occurred in the Turkey-Iran border region, using the data recorded by the IMS. At the beginning, the algorithm was applied to the differences among the original arrival times of the P phases, so the cross-correlation was not used. We have obtained that the relevant geometrical spreading, noticeable in the standard locations (namely the locations produced by the analysts of the International Data Center (IDC) of the CTBT Organization, assumed as our reference), has been considerably reduced by the application of our technique. This is what we expected, since the methodology has been applied to a sequence of events for which we can suppose a real closeness among the hypocenters, belonging to the same seismic structure. Our results point out the main advantage of this methodology: the systematic errors affecting the arrival times have been removed or at least reduced. The introduction of the cross-correlation has not brought evident improvements to our results: the two sets of locations (without and with the application of the cross-correlation technique) are very similar to each other. This can be commented saying that the use of the crosscorrelation has not substantially improved the precision of the manual pickings. Probably the pickings reported by the IDC are good enough to make the random picking error less important than the systematic error on travel times. As a further justification for the scarce quality of the results given by the cross-correlation, it should be remarked that the events included in our data set don’t have generally a good signal to noise ratio (SNR): the selected sequence is composed of weak events ( magnitude 4 or smaller) and the signals are strongly attenuated because of the large distance between the stations and the hypocentral area. In the local scale, in addition to the cross-correlation, we have performed a signal interpolation in order to improve the time resolution. The algorithm so developed has been applied to the data collected during an experiment carried out in Israel between 1998 and 1999. The results pointed out the following relevant conclusions: a) it is necessary to correlate waveform segments corresponding to the same seismic phases; b) it is not essential to select the exact first arrivals; and c) relevant information can be also obtained from the maximum amplitude wavelet of the waveforms (particularly in bad SNR conditions). Another remarkable point of our procedure is that its application doesn’t demand a long time to process the data, and therefore the user can immediately check the results. During a field survey, such feature will make possible a quasi real-time check allowing the immediate optimization of the array geometry, if so suggested by the results at an early stage.
Resumo:
Monte Carlo (MC) simulation techniques are becoming very common in the Medical Physicists community. MC can be used for modeling Single Photon Emission Computed Tomography (SPECT) and for dosimetry calculations. 188Re, is a promising candidate for radiotherapeutic production and understanding the mechanisms of the radioresponse of tumor cells "in vitro" is of crucial importance as a first step before "in vivo" studies. The dosimetry of 188Re, used to target different lines of cancer cells, has been evaluated by the MC code GEANT4. The simulations estimate the average energy deposition/per event in the biological samples. The development of prototypes for medical imaging, based on LaBr3:Ce scintillation crystals coupled with a position sensitive photomultiplier, have been studied using GEANT4 simulations. Having tested, in the simulation, surface treatments different from the one applied to the crystal used in our experimental measurements, we found out that the Energy Resolution (ER) and the Spatial Resolution (SR) could be improved, in principle, by machining in a different way the lateral surfaces of the crystal. We have then studied a system able to acquire both echographic and scintigraphic images to let the medical operator obtain the complete anatomic and functional information for tumor diagnosis. The scintigraphic part of the detector is simulated by GEANT4 and first attempts to reconstruct tomographic images have been made using as method of reconstruction a back-projection standard algorithm. The proposed camera is based on slant collimators and LaBr3:Ce crystals. Within the Field of View (FOV) of the camera, it possible to distinguish point sources located in air at a distance of about 2 cm from each other. In particular conditions of uptake, tumor depth and dimension, the preliminary results show that the Signal to Noise Ratio (SNR) values obtained are higher than the standard detection limit.
Resumo:
Investigation on impulsive signals, originated from Partial Discharge (PD) phenomena, represents an effective tool for preventing electric failures in High Voltage (HV) and Medium Voltage (MV) systems. The determination of both sensors and instruments bandwidths is the key to achieve meaningful measurements, that is to say, obtaining the maximum Signal-To-Noise Ratio (SNR). The optimum bandwidth depends on the characteristics of the system under test, which can be often represented as a transmission line characterized by signal attenuation and dispersion phenomena. It is therefore necessary to develop both models and techniques which can characterize accurately the PD propagation mechanisms in each system and work out the frequency characteristics of the PD pulses at detection point, in order to design proper sensors able to carry out PD measurement on-line with maximum SNR. Analytical models will be devised in order to predict PD propagation in MV apparatuses. Furthermore, simulation tools will be used where complex geometries make analytical models to be unfeasible. In particular, PD propagation in MV cables, transformers and switchgears will be investigated, taking into account both irradiated and conducted signals associated to PD events, in order to design proper sensors.
Resumo:
Das Protein Cytochrom c Oxidase (CcO) ist ein Enzym der mitochondrialen Atmungskette. Als letzter Komplex (Komplex IV) einer Elektronentransportkette katalysiert sie die Reduktion von molekularem Sauerstoff zu Wasser. Hierbei werden Elektronen von Cytochrom c (Cc) in das Enzym geleitet. Die durch den Redoxprozess freiwerdende freie Enthalpie wird dazu genutzt, einen Protonengradienten über die innere Mitochondrien-Membran aufzubauen. Die zurückwandernden Protonen treiben in der ATP-Synthase die Produktion von Adenosintriphosphat (ATP) an, dem universellen Energieträger in lebenden Organismen. Gegenstand dieser Dissertation sind zeitaufgelöste ATR-FTIR-Messungen des direkten Elektronentransfers in die CcO. Das Protein wird hierzu orientiert auf einer Goldelektrode immobilisiert und in eine künstliche Membran rekonstituiert (Protein-tethered Bilayer Lipid Membrane, ptBLM). Das ptBLM-System wird hinsichtlich einer möglichst hohen Protein-Aktivität optimiert. Elektronen werden durch elektrochemische Anregung von der Elektrode in die CcO injiziert. Die Goldoberfläche wird auf die reflektierende Oberfläche eines Silizium-ATR-Kristalls aufgebracht. Durch die Präparation einer rauen Oberfläche (RMS-Rauigkeit ca. 5 nm) wird eine Verstärkung der IR-Absorption erreicht. Die mit den Ladungstransferprozessen einhergehenden Konformationsänderungen der die Redoxzentren umgebenden Gruppen (CONH-Gerüst und Aminosäure-Seitenketten) können durch Infrarot-Spektroskopie nachgewiesen werden. Phasensensitive Detektion (PSD) wird zur Rauschminderung eingesetzt, um Geschwindigkeitskonstanten für die Redox-Übergänge zu bestimmen. Im Bereich der Amid-I-Bande werden etliche Peaks identifiziert, die sich mit dem Redoxzustand des Proteins ändern. Für das CuA-Zentrum, welches als erstes der vier Redoxzentren der CcO reduziert wird, wird die schnellste Geschwindigkeitskonstante ks=4870/s ermittelt. Für das Häm a3-Zentrum wird eine Geschwindigkeitskonstante von ks=13,8/s ermittelt. Die Ergebnisse sind konsistent zu elektrochemischen und Raman-Spektroskopie-Experimenten, welche ebenfalls in unserer Gruppe durchgeführt wurden. Weitere Themen dieser Dissertation sind der Nachweis der Anwendbarkeit des ptBLM-Systems für andere Membranproteine (Beispiel: bakterielles photosynthetisches Reaktionszentrum) und der Einsatz des ATR-FTIR-Setups für verschiedene künstliche Membransysteme (Aktivitätsnachweis des OR5-Geruchsrezeptors in einer peptidgestützten Membran, Eigenschaften eines Oligoethylenglycol-Spacers).
Resumo:
Die optische Eigenschaften sowie der Oberflächenverstärkungseffekt von rauen Metalloberflächen sowie Nanopartikeln wurden intensiv für den infraroten Bereich des Spektrums in der Literatur diskutiert. Für die Präparation solcher Oberflächen gibt es prinzipiell zwei verschiedene Strategien, zum einen können die Nanopartikel zuerst ex-situ synthetisiert werden, der zweite Ansatz beruht darauf, dass die Nanopartikel in-situ hergestellt und aufgewachsen werden. Hierbei wurden beide Ansätze ausgetestet, dabei stellte sich heraus, dass man nur mittels der in-situ Synthese der Goldnanopartikel in der Lage ist nanostrukturierte Oberflächen zu erhalten, welche elektronisch leitfähig sind, nicht zu rau sind, um eine Membranbildung zu ermöglichen und gleichzeitig einen optimalen Oberflächenverstärkungseffekt zeigen. Obwohl keine ideale Form der Nanopartikel mittels der in-situ Synthese erhalten werden können, verhalten sich diese dennoch entsprechend der Theorie des Oberflächenverstärkungseffekts. Optimierungen der Form und Grösse der Nanopartikel führten in dieser Arbeit zu einer Optimierung des Verstärkungseffekts. Solche optimierten Oberflächen konnten einfach reproduziert werden und zeichnen sich durch eine hohe Stabilität aus. Der so erhaltene Oberflächenverstärkungseffekt beträgt absolut 128 verglichen mit dem belegten ATR-Kristall ohne Nanopartikel oder etwa 6 mal, verglichen mit der Oberfläche, die bis jetzt auch in unserer Gruppe verwendet wurde. Daher können nun Spektren erhalten werden, welche ein deutlich besseres Signal zu Rauschverhältnis (SNR) aufweisen, was die Auswertung und Bearbeitung der erhaltenen Spektren deutlich vereinfacht und verkürzt.rnNach der Optimierung der verwendeten Metalloberfläche und der verwendeten Messparameter am Beispiel von Cytochrom C wurde nun an der Oberflächenbelegung der deutlich größeren Cytochrom c Oxidase gearbeitet. Hierfür wurde der DTNTA-Linker ex-situ synthetisiert. Anschließend wurden gemischte Monolagen (self assembeld monolayers) aus DTNTA und DTP hergestellt. Die NTA-Funktionalität ist für die Anbindung der CcO mit der his-tag Technologie verantwortlich. Die Kriterien für eine optimale Linkerkonzentration waren die elektrischen Parameter der Schicht vor und nach Rekonstitution in eine Lipidmembran, sowie Elektronentransferraten bestimmt durch elektrochemische Messungen. Erst mit diesem optimierten System, welches zuverlässig und reproduzierbar funktioniert, konnten weitere Messungen an der CcO begonnen werden. Aus elektrochemischen Messungen war bekannt, dass die CcO durch direkten Elektronentransfer unter Sauerstoffsättigung in einen aktivierten Zustand überführt werden kann. Dieser aktivierte Zustand zeichnet sich durch eine Verschiebung der Redoxpotentiale um etwa 400mV gegenüber dem aus Gleichgewichts-Titrationen bekannten Redoxpotential aus. Durch SEIRAS konnte festgestellt werden, dass die Reduktion bzw. Oxidation aller Redoxzentren tatsächlich bei den in der Cyclovoltammetrie gemessenen Potentialen erfolgt. Außerdem ergaben die SEIRA-Spektren, dass durch direkten Elektronentransfer gravierende Konformationsänderungen innerhalb des Proteins stattfinden. rnBisher war man davon ausgegangen, aufgrund des Elektronentransfers mittels Mediatoren, dass nur minimale Konformationsänderungen beteiligt sind. Vor allem konnte erstmaligrnder aktivierte und nicht aktivierte Zustand der Cytochrom c Oxidase spektroskopisch nachweisen werden.rn
Bau und Entwicklung eines Applikators zur Verabreichung hyperpolarisierter Gase in der MRT der Lunge
Resumo:
Im Rahmen meiner Dissertation habe ich gemäß dem Medizinproduktegesetz ein MR-kompatibles Verabreichungsgerät entwickelt, um Patienten hyperpolarisierte Gas Boli (He-3, Xe-129) als Kontrasgas zur MRT der Lunge zu applizieren. Das Gerät wurde dazu optimiert, die Gase oder Gasmischungen (z. B. HP Gas + N2) in definierten Mengen und zu definierten Zeitpunkten während der Inspiration mit hoher Reproduzierbarkeit und Zuverlässigkeit zu verabreichen, ohne dabei die MR-Qualität zu beeinträchtigen. Aus Sicherheitsgründen und zur späteren Datenanalyse werden die Atemflusskurven der Patienten kontinuierlich angezeigt und aufgezeichnet. Ein Kolbenkompressor ist integriert, um die gesamte gespeicherte He-3-Menge nutzen zu können. Weiterhin ist es möglich, die Polarisation vor Ort zu bestimmen und das abgeatmete He-3 zur späteren Rückgewinnung aufzufangen. Diese Auffangeffizienz konnte durch Untersuchungen mit He-4 (als He-3-Ersatz) gesteigert werden.rnDie ersten MR-Aufnahmen von 10 gesunden Probanden wurden mit diesem Aufbau imrnRahmen einer klinischen Studie durchgeführt. Die Analyse der bestimmten MR-Parameter Signal-Rausch-Verhältnis (SNR), Sauerstoffpartialdruck (pO2), Scheinbarer Diffusionskoeffizient (ADC=apparent diffusion coefficient) sowie die Signalanstiegszeit (rise-time) zeigt eine deutlich bessere Reproduzierbarkeit bei der Verabreichung des He-3 mit dem Applikators anstelle eines Tedlarbags (= kleine heliumdichte Plastiktüte).
Resumo:
A 20-channel phased-array coil for MRI of mice has been designed, constructed, and validated with bench measurements and high-resolution accelerated imaging. The technical challenges of designing a small, high density array have been overcome using individual small-diameter coil elements arranged on a cylinder in a hexagonal overlapping design with adjacent low impedance preamplifiers to further decouple the array elements. Signal-to-noise ratio (SNR) and noise amplification in accelerated imaging were simulated and quantitatively evaluated in phantoms and in vivo mouse images. Comparison between the 20-channel mouse array and a length-matched quadrature driven small animal birdcage coil showed an SNR increase at the periphery and in the center of the phantom of 3- and 1.3-fold, respectively. Comparison with a shorter but SNR-optimized birdcage coil (aspect ratio 1:1 and only half mouse coverage) showed an SNR gain of twofold at the edge of the phantom and similar SNR in the center. G-factor measurements indicate that the coil is well suited to acquire highly accelerated images.
Resumo:
Recent optimizations of NMR spectroscopy have focused their attention on innovations in new hardware, such as novel probes and higher field strengths. Only recently has the potential to enhance the sensitivity of NMR through data acquisition strategies been investigated. This thesis has focused on the practice of enhancing the signal-to-noise ratio (SNR) of NMR using non-uniform sampling (NUS). After first establishing the concept and exact theory of compounding sensitivity enhancements in multiple non-uniformly sampled indirect dimensions, a new result was derived that NUS enhances both SNR and resolution at any given signal evolution time. In contrast, uniform sampling alternately optimizes SNR (t < 1.26T2) or resolution (t~3T2), each at the expense of the other. Experiments were designed and conducted on a plant natural product to explore this behavior of NUS in which the SNR and resolution continue to improve as acquisition time increases. Possible absolute sensitivity improvements of 1.5 and 1.9 are possible in each indirect dimension for matched and 2x biased exponentially decaying sampling densities, respectively, at an acquisition time of ¿T2. Recommendations for breaking into the linear regime of maximum entropy (MaxEnt) are proposed. Furthermore, examination into a novel sinusoidal sampling density resulted in improved line shapes in MaxEnt reconstructions of NUS data and comparable enhancement to a matched exponential sampling density. The Absolute Sample Sensitivity derived and demonstrated here for NUS holds great promise in expanding the adoption of non-uniform sampling.