743 resultados para removable appliance


Relevância:

20.00% 20.00%

Publicador:

Resumo:

On one side, prosthodontic reconstructions compensate for the sequelae of negative changes in the oral cavity; on the other side, they often enhance or accelerate them. As a consequence of negative changes in the oral cavity over time, treatment planning for RPDs becomes highly complex. A set of reliable criteria is necessary for decision-making and problem management It appears that the majority of published data on RPDs does not depict high effectiveness of this treatment modality. From a strict point of view of evidence-based dentistry, the level of evidence is low if not missing for RPDs. Randomized controlled trials on RPDs are difficult to design, they are not feasible for some questions due to the complexity of the material, or may remain without clinical relevance. The literature rarely gives information on the denture design, tooth selection, and management of the compromised structural integrity of teeth. So far treatment outcomes with RPDs must be considered under the aspect of bias due to the bias in indication and patient selection for RPDs. Better clinical models should be elaborated with more stringent concepts for providing RPDs. This encompasses: risk analysis and patient assessment, proper indications for maintenance or extraction of teeth, strategic placement of implants, biomechanical aspects, materials, and technology. Although there is a tendency to offer fixed prostheses to our patients, this might change again with demographic changes and with an increase in the ageing population, an increase in their reduced dentition, and low socioeconomic wealth in large parts of the world.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to analyze prosthetic maintenance in partially edentulous patients with removable prostheses supported by teeth and strategic implants. MATERIALS AND METHODS: Sixty patients with removable partial prostheses and combined tooth-implant support were identified within the time period from 1998 to 2006. One group consisted of 42 patients (planned group) with a reduced residual dentition and in need of removable partial dentures (RPDs) or overdentures in the maxilla and/or mandible. They were admitted consecutively for treatment. Due to missing teeth in strategic important positions, one or two implants were placed to improve symmetrical denture support and retention. The majority of residual teeth exhibited an impaired structural integrity and therefore were provided with root copings for denture retention. A few vital teeth were used for telescopic crowns. The anchorage system for the strategic implants was selected accordingly. A second group of 18 patients (repair group) wearing RPDs with the loss of one abutment tooth due to biologic or mechanical failure was identified. These abutment teeth were replaced by 21 implants, and patients continued to wear their original prostheses. The observation time for planned and repair groups was 12 months to 8 years. All patients followed a regular maintenance schedule. Technical or biologic complications with supporting teeth or implants and prosthetic service were registered regularly. RESULTS: Three maxillary implants were lost after loading and three roots with copings had to be removed. Biologic problems included caries and periodontal/peri-implant infection with a significantly higher incidence in the repair group (P < .05). Technical complications with the dentures were rather frequent in both groups, mostly related to the anchorage system (matrices) of root copings and implants. Maintenance and complications were observed more frequently in the first year after delivery of the denture than in the following 3 years (P < .05). No denture had to be remade. CONCLUSIONS: The placement of a few implants allows for maintaining a compromised residual dentition for support of RPDs. The combination of root and implant support facilitates treatment planning and enhances designing the removable denture. It also proves to be a practical rescue method. Technical problems with the anchorage system were frequent, particularly in the first year after delivery of the dentures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: This retrospective study reports the clinical outcome following placement of extraoral implants in severely resorbed posterior ridges to support distal-extension removable dentures. MATERIAL AND METHODS: Consecutively treated patients with partially or completely edentulous ridges, with available bone height in the posterior region of 6 mm or less, were included in the study. Implants originally intended for extraoral use (Straumann) were placed in second molar regions and allowed to heal for 4 to 6 months before abutment connection. At recall appointments, the peri-implant hard and soft tissues were evaluated. Complications with implant components, as well as mechanical and structural failures of the prostheses, were recorded. Two-year survival rates were calculated and life table analyses undertaken. RESULTS: Twenty-nine patients (19 women and 10 men; average age 61.2 years, range, 44 to 75 years) were included in the study. Forty-seven extraoral implants in 26 patients were placed in the second molar site of the mandible. Two extraoral implants in 2 patients failed during the osseointegration phase, yielding an 8-year cumulative success rate of 91.8%. The mean distance from the extraoral implants to the most distal tooth/implant was 28.1 mm (range, 16.7 to 39.2 mm). Twenty-three extraoral implants were restored with magnets, 18 with ball anchors, and 4 with conical cylinders. Replacement of abutments and retention elements was necessary in 2 patients. Four abutments in 2 patients were disconnected from the restorations. CONCLUSIONS: Within the limits of the employed research design, extraoral implants may be used successfully to provide support for distal-extension removable dentures in severely resorbed posterior alveolar ridges.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION The purpose of this study was to examine the overall success of miniscrews inserted in the paramedian palatal region for support of various appliances during orthodontic treatment. METHODS The patients received 1 or 2 miniscrews in the paramedian anterior palate of 8.0-mm length and 1.6-mm diameter placed during orthodontic treatment by the same experienced orthodontist. RESULTS In total, 196 patients (121 girls, 75 boys; median age, 11.7; interquartile range, 3.7) who received 384 miniscrews were evaluated. Two hundred four miniscrews were used with rapid palatal expansion appliances, 136 with appliances for distalization of posterior teeth, and 44 with other appliances, such as transpalatal arches for tooth stabilization. The overall survival of the miniscrews was excellent (97.9%) in the cases examined. Cox regression analysis showed no difference in the overall survival rates of miniscrews loaded with different appliances for sex (hazard ratio, 0.95; 95% confidence interval, 0.71-1.27; P = 0.73) after adjusting for appliance and age. CONCLUSIONS This study shows that miniscrews placed in the paramedian anterior palate for supporting various orthodontic appliances have excellent survival.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM To compare dentoskeletal and soft tissue treatment effects of two alternative Class II division 1 treatment modalities (maxillary first permanent molar extraction versus Herbst appliance). METHODS One-hundred-fifty-four Class II division 1 patients that had either been treated with extractions of the upper first molars and a lightwire multibracket (MB) appliance (n = 79; 38 girls, 41 boys) or non-extraction by means of a Herbst-MB appliance (n = 75; 35 girls, 40 boys). The groups were matched on age and sex. The average age at the start of treatment was 12.7 years for the extraction and for 13.0 years for the Herbst group. Pretreatment (T1) and posttreatment (T2) lateral cephalograms were retrospectively analyzed using a standard cephalometric analysis and the sagittal occlusal analysis according to Pancherz. RESULTS The SNA decrease was 1.10° (p = 0.001) more pronounced in the extraction group, the SNB angle increased 1.49° more in the Herbst group (p = 0.000). In the extraction group, a decrease in SNB angle (0.49°) was observed. The soft tissue profile convexity (N-Sn-Pog) decreased in both groups, which was 0.78° more (n. s.) pronounced in the Herbst group. The nasolabial angle increased significantly more (+ 2.33°, p = 0.025) in the extraction group. The mechanism of overjet correction in the extraction group was predominantly dental (65% dental and 35% skeletal changes), while in the Herbst group it was predominantly skeletal (58% skeletal and 42% dental changes) in origin. CONCLUSION Both treatment methods were successful and led to a correction of the Class II division 1 malocclusion. Whereas for upper first molar extraction treatment more dental and maxillary effects can be expected, in case of Herbst treatment skeletal and mandibular effects prevail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To assess objectively patient compliance with removable orthodontic appliances and the effect of possible influential factors. MATERIALS AND METHODS Wearing times of 45 White patients were recorded with the aid of the TheraMon microsensor. Patient compliance was assessed relative to wear prescription and other parameters, such as age and sex. RESULTS There was high individual variation in most measured variables and in all groups/subgroups. During a median observation period of 186 days (range, 55-318 days) the actual wear time was 9.0 h/d (range, 0.0-16.0 h/d) and did not differ between distinct prescriptions (P = .49). Eight patients wore their appliances less than 2 h/d, and six of them did not wear their appliances at all. Overall, the median wear per day relative to prescription was 62.5% (range, 0.0-89.3%) for the 14 h/d and 112.5% (range, 0.0-200.0%) for the 8 h/d prescription wear (P = .01) groups. There was a strong negative correlation of age (median: 12.5 years) with the daily percentage of actual wear time per day relative to wear prescription (14 h/d prescription: n = 21, rho = -0.61, P = .00; 8 h/d prescription: n = 24, rho = -0.73, P = .00), while sex did not exert a significant influence on compliance (P = .58). CONCLUSIONS Despite the fact that patients and parents were informed about wear time recording, compliance was insufficient with regard to functional treatment (14 h/d prescription), while it was sufficient for retention purposes (8 h/d prescription). Objective measures are necessary to assess compliance with removable orthodontic appliances since patient compliance is a highly variable issue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Cochlear implants (CIs) are standard treatment for postlingually deafened individuals and prelingually deafened children. This human cadaver study evaluated diagnostic usefulness, image quality and artifacts in 1.5T and 3T magnetic resonance (MR) brain scans after CI with a removable magnet. METHODS Three criteria (diagnostic usefulness, image quality, artifacts) were assessed at 1.5T and 3T in five cadaver heads with CI. The brain magnetic resonance scans were performed with and without the magnet in situ. The criteria were analyzed by two blinded neuroradiologists, with focus on image distortion and limitation of the diagnostic value of the acquired MR images. RESULTS MR images with the magnet in situ were all compromised by artifacts caused by the CI. After removal of the magnet, MR scans showed an unequivocal artifact reduction with significant improvement of the image quality and diagnostic usefulness, both at 1.5T and 3T. Visibility of the brain stem, cerebellopontine angle, and parieto-occipital lobe ipsilateral to the CI increased significantly after magnet removal. CONCLUSIONS The results indicate the possible advantages for 1.5T and 3T MR scanning of the brain in CI carriers with removable magnets. Our findings support use of CIs with removable magnets, especially in patients with chronic intracranial pathologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Submitted in partial fulfillment of the requirements for a Certificate in Orthodontics, Dept. of Orthodontics, University of Connecticut Health Center, 1986

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the transition period from a planned economy to a market economy in 1990s of China, there was a considerable accrual of deferred payment, and default due to inferior enforcement institutions. This is a very common phenomenon in the transition economies at that time. Interviews with home electronics appliance firms revealed that firms coped with this problem by adjusting their sales mechanisms (found four types), and the benefit of institutions was limited. A theoretical analysis claim that spot and integration are inferior to contracts, a contract with a rebate on volume and prepayment against an exclusive agent can realize the lowest cost and price. The empirical part showed that mechanisms converged into a mechanism with the rebate on volume an against exclusive agent and its price level is the lowest. The competition is the driving force of the convergence of mechanisms and improvement risk management capacity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo avaliou a estabilidade das alterações dentárias e esqueléticas produzidas pela Expansão Rápida da Maxila Assistida Cirurgicamente (ERMAC), no sentido transversal e vertical. A amostra selecionada para este estudo retrospectivo foi composta de 60 telerradiografias em norma frontal, de 15 pacientes, sendo 6 do sexo masculino e 9 do sexo feminino, com média de idade de 23 anos e 3 meses. Utilizou-se o disjuntor tipo Hyrax e o procedimento cirúrgico foi caracterizado pela osteotomia sagital mediana da maxila e não abordagem da sutura pterigopalatina. O início da ativação ocorreu no terceiro dia pós-operatório, sendo que, os limites para a expansão foram determinados por critérios eminentemente clínicos. Todos os pacientes foram radiografados nas fases pré-expansão (T1), pós-expansão imediata (T2), 3 meses pós- expansão (com o próprio disjuntor como contenção) (T3) e 6 meses pós-expansão (com a placa de acrílico removível como contenção) (T4). Medidas lineares foram obtidas a partir dos traçados cefalométricos gerados por um programa computadorizado (Radiocef Studio 2) e analisadas estatisticamente pelo teste de variância (ANOVA) e Tukey ao nível de 5% de significância. Concluiu-se que a ERMAC produziu um aumento estatisticamente significante, da cavidade nasal, largura maxilar, distância intermolares superiores, de T1 para T2, e que se mantiveram em T3 e T4. A largura facial e as distâncias intermolares inferiores não apresentaram alterações após a ERMAC. Avaliando o comportamento vertical da face, notou-se um aumento da AFAI nos tempos T1 para T2 que, diminuiu após a contenção de 3 meses (T3) e permaneceu estável em T4, embora aumentada se comparada com T1.(AU)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo avaliou a estabilidade das alterações dentárias e esqueléticas produzidas pela Expansão Rápida da Maxila Assistida Cirurgicamente (ERMAC), no sentido transversal e vertical. A amostra selecionada para este estudo retrospectivo foi composta de 60 telerradiografias em norma frontal, de 15 pacientes, sendo 6 do sexo masculino e 9 do sexo feminino, com média de idade de 23 anos e 3 meses. Utilizou-se o disjuntor tipo Hyrax e o procedimento cirúrgico foi caracterizado pela osteotomia sagital mediana da maxila e não abordagem da sutura pterigopalatina. O início da ativação ocorreu no terceiro dia pós-operatório, sendo que, os limites para a expansão foram determinados por critérios eminentemente clínicos. Todos os pacientes foram radiografados nas fases pré-expansão (T1), pós-expansão imediata (T2), 3 meses pós- expansão (com o próprio disjuntor como contenção) (T3) e 6 meses pós-expansão (com a placa de acrílico removível como contenção) (T4). Medidas lineares foram obtidas a partir dos traçados cefalométricos gerados por um programa computadorizado (Radiocef Studio 2) e analisadas estatisticamente pelo teste de variância (ANOVA) e Tukey ao nível de 5% de significância. Concluiu-se que a ERMAC produziu um aumento estatisticamente significante, da cavidade nasal, largura maxilar, distância intermolares superiores, de T1 para T2, e que se mantiveram em T3 e T4. A largura facial e as distâncias intermolares inferiores não apresentaram alterações após a ERMAC. Avaliando o comportamento vertical da face, notou-se um aumento da AFAI nos tempos T1 para T2 que, diminuiu após a contenção de 3 meses (T3) e permaneceu estável em T4, embora aumentada se comparada com T1.(AU)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have completed the total chemical synthesis of cytochrome b562 and an axial ligand analogue, [SeMet7]cyt b562, by thioester-mediated chemical ligation of unprotected peptide segments. A novel auxiliary-mediated native chemical ligation that enables peptide ligation to be applied to protein sequences lacking cysteine was used. A cleavable thiol-containing auxiliary group, 1-phenyl-2-mercaptoethyl, was added to the α-amino group of one peptide segment to facilitate amide bond-forming ligation. The amine-linked 1-phenyl-2-mercaptoethyl auxiliary was stable to anhydrous hydrogen fluoride used to cleave and deprotect peptides after solid-phase peptide synthesis. Following native chemical ligation with a thioester-containing segment, the auxiliary group was cleanly removed from the newly formed amide bond by treatment with anhydrous hydrogen fluoride, yielding a full-length unmodified polypeptide product. The resulting polypeptide was reconstituted with heme and folded to form the functional protein molecule. Synthetic wild-type cyt b562 exhibited spectroscopic and electrochemical properties identical to the recombinant protein, whereas the engineered [SeMet7]cyt b562 analogue protein was spectroscopically and functionally distinct, with a reduction potential shifted by ≈45 mV. The use of the 1-phenyl-2-mercaptoethyl removable auxiliary reported here will greatly expand the applicability of total protein synthesis by native chemical ligation of unprotected peptide segments.