981 resultados para relief


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The study goal was to compare the efficacy of expressed breast milk (EBM) versus 25% glucose on pain responses of late preterm infants during heel lancing. METHODS: In a noninferiority randomized controlled trial, a total of 113 newborns were randomized to receive EBM (experimental group [EG]) or 25% glucose (control group [CG]) before undergoing heel lancing. The primary outcome was pain intensity (Premature Infant Pain Profile [PIPP]) and a 10% noninferiority margin was established. Secondary outcomes were incidence of cry and percentage of time spent crying and adverse events. Intention-to-treat (ITT) analysis was used. RESULTS: Groups were similar regarding demographics and clinical characteristics, except for birth weight and weight at data collection day. There were lower pain scores in the CG over 3 minutes after lancing (P<.001). A higher number of infants in the CG had PIPP scores indicative of minimal pain or absence of pain (P = .002 and P = .003 on ITT analysis) at 30 seconds after lancing, and the mean difference in PIPP scores was 3 (95% confidence interval: 1.507-4.483). Lower incidence of cry (P = .001) and shorter duration of crying (P = .014) were observed for CG. Adverse events were benign and self-limited, and there was no significant difference between groups (P = .736 and P = .637 on ITT analysis). CONCLUSIONS: Results based on PIPP scores and crying time indicate poorer effects of EBM compared with 25% glucose during heel lancing. Additional studies exploring the vol and administration of EBM and its combination with other strategies such as skin-to-skin contact and sucking are necessary. Pediatrics 2012;129:664-670

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: We evaluated the effectiveness of high-frequency transcutaneous electrical nerve stimulation (TENS) as a pain relief resource for primiparous puerpere who had experienced natural childbirth with an episiotomy. Methods: A controlled, randomized clinical study was conducted in a Brazilian maternity ward. Forty puerpere were randomly divided into two groups: TENS high frequency and a no treatment control group. Post-episiotomy pain was assessed in the resting and sitting positions and during ambulation. An 11-point numeric rating scale was performed in three separate evaluations (at the beginning of the study, after 60 min and after 120 min). The McGill pain questionnaire was employed at the beginning and 60 min later. TENS with 100 Hz frequency and 75 mu s pulse for 60 min was employed without causing any pain. Four electrodes ware placed in parallel near the episiotomy site, in the area of the pudendal and genitofemoral nerves. Results: An 11-point numeric rating scale and McGill pain questionnaire showed a significant statistical difference in pain reduction in the TENS group, while the control group showed no alteration in the level of discomfort. Hence, high-frequency TENS treatment significantly reduced pain intensity immediately after its use and 60 min later. Conclusion: TENS is a safe and viable non-pharmacological analgesic resource to be employed for pain relief post-episiotomy. The routine use of TENS post-episiotomy is recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims and objectives. To evaluate the effectiveness of a low-level laser therapy for pain relief in the perineum following episiotomy during childbirth. Background. Laser irradiation is a painless and non-invasive therapy for perineal pain treatment and its effects have been investigated in several studies, with no clear conclusion on its effectiveness. Design. A double-blind randomised controlled clinical trial. Method. One hundred and fourteen women who underwent right mediolateral episiotomies during vaginal birth in an in-hospital birthing centre in Sao Paulo, Brazil and reported pain =3 on a numeric scale (010) were randomised into three groups of 38 women each: two experimental groups (treated with red and infrared laser) and a control group. The experimental groups were treated with laser applied at three points directly on the episiotomy after suturing in a single session between 656 hours postpartum. We used a diode laser with wavelengths of 660 nm (red laser) and 780 nm (infrared laser). The control group participants underwent all laser procedures, excluding the emission of irradiation. The participants and the pain scores evaluator were blinded to the type of intervention. The perineal pain scores were assessed at three time points: before, immediately after and 30 minutes after low-level laser therapy. Results. The comparison of perineal pain between the three groups showed no significant differences in the three evaluations (p = 0.445), indicating that the results obtained in the groups treated with low-level laser therapy were equivalent to the control group. Conclusions. Low-level laser therapy did not decrease the intensity of perineal pain reported by women who underwent right mediolateral episiotomy. Relevance to clinical practice. The effect of laser in perineal pain relief was not demonstrated in this study. The dosage may not have been sufficient to provide relief from perineal pain after episiotomy during a vaginal birth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a comparison of descriptive statistics obtained for brittle structural lineaments extracted manually from LANDSAT images and shaded relief images from SRTM 3 DEM at 1:100, 000 and 1:500, 000 scales. The selected area is located in the southern of Brazil and comprises Precambrian rocks and stratigraphic units of the Paraná Basin. The application of this methodology shows that the visual interpretation depends on the kind of remote sensing image. The resulting descriptive statistics obtained for lineaments extracted from the images do not follow the same pattern according to the scale adopted. The main direction obtained for Proterozoic rocks using both image types at a 1:500, 000 scale are close to NS±10, whereas at a 1:100, 000 scale N45E was obtained for shaded relief images from SRTM 3 DEM and N10W for LANDSAT images. The Paleozoic sediments yielded the best results for the different images and scales (N50W). On the other hand, the Mesozoic igneous rocks showed greatest differences, the shaded relief images from SRTM 3 DEM images highlighting NE structures and the LANDSAT images highlighting NW structures. The accumulated frequency demonstrated high similarity between products for each image type no matter the scale, indicating that they can be used in multiscale studies. Conversely, major differences were found when comparing data obtained using shaded relief images from SRTM 3 DEM and Landsat images at a 1:100, 000 scale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of cryogenic and stress relief treatments on temper carbide precipitation in the cold work tool steel AISI D2 were studied. For the cryogenic treatment the temperature was −196°C and the holding time was 2, 24 or 30 h. The stress relief heat treatment was carried at 130°C/90 min, when applied. All specimens were compared to a standard thermal cycle. Specimens were studied using metallographic characterisation, X-ray diffraction and thermoelectric power measurements. The metallographic characterisation used SEM (scanning electron microscopy) and SEM-FEG (SEM with field emission gun), besides OM (optical microscopy). No variation in the secondary carbides (micrometre sized) precipitation was found. The temper secondary carbides (nanosized) were found to be more finely dispersed in the matrix of the specimens with cryogenic treatment and without stress relief. The refinement of the temper secondary carbides was attributed to a possible in situ carbide precipitation during tempering.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordinating organizational activity across different sectors is crucial in disaster management. We analysed the response of 291 aid workers to the Haiti earthquake in 2010 and found that common incentives and a high degree of equality among aid organizations positively affected perceived network coordination. Large and public organizations were more likely to take leadership roles and high numbers of public organizations involved in the disaster response network led to improved network coordination. These results indicate the need for mechanisms that enable smaller and non-profit organizations to participate in network coordination and leadership.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To test the comparative effectiveness of 2 nonpharmacologic pain-relieving interventions administered alone or in combination across time for repeated heel sticks in preterm infants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In Switzerland approximately 8% of infants are born prematurely. Some of them undergo mechanical ventilation including endotracheal suctioning (ETS). ETS is one of the most frequently performed interventions and is linked to stress and pain, but its treatment is controversial. In Switzerland there is a lack of standardisation in pain relief for ETS. AIMS: To test the hypothesis that an intermittent dose of morphine reduces pain during ETS and that subsequent multisensorial stimulation (MSS), as a non pharmacological comforting intervention, helps infants to recover from experienced pain. METHOD: A randomized placebo controlled trial in two tertiary neonatal intensive care units (NICU) with a sample of 30 mechanically ventilated preterm infants was conducted. Pain was measured by three pain assessment tools (Bernese Pain Scale for Neonates, Premature Infant Pain Profile and Visual Analogue Scale) RESULTS: Morphine did not lead to any pain relief from ETS as measured by three pain scales. Nor did the comforting intervention of MSS show any effect. Repeated-measure analysis of variance for the within and between groups comparison showed no statistical significance. CONCLUSIONS: The administration of morphine for pain relief in ventilated preterm neonates during ETS remains questionable and the use of MSS as a comforting intervention after painful stimulus cannot be recommended. The validity testing of the instruments for this patient population should undergo a systematic validation trajectory. Future research should focus on options among non pharmacological interventions for relieving pain during ETS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The effectiveness of vertebral augmentation techniques is a currently highly debated issue. The biomechanical literature suggests that cement filling volumes may play an important role in the ‘‘dosage’’ of vertebral augmentation and its pain alleviating effect. Good clinical data about filling volumes are scarce and most patient series are small. Therefore, we investigated the predictors of pain alleviation after balloon kyphoplasty in the nationwide SWISSspine registry where cement volumes are also recorded. Methods All single-level vertebral fractures with no additional fracture stabilization and availability of at least one follow-up within 6 months after surgery were included. The following potential predictors were assessed in a multivariate logistic regression model with the group’s average pain alleviation of 41 points on VAS as the desired outcome: patient age, patient sex, diagnosis, preoperative pain, level of fracture, type of fracture, age of fracture, segmental kyphotic deformity, cement volume, vertebral body filling volume, and cement extrusions. Results There were 194 female and 82 males with an average age of 70.4 and 65.3 years, respectively. Female patients were about twice as likely for achieving the average pain relief compared to males (p = 0.04). The preoperative pain level was the strongest predictor in that the likelihood for achieving an at least 41-point pain relief increased by about 8 % with each additional point of preoperative pain (p\0.001). A thoraco-lumbar fracture had a three times higher odds for the average pain relief compared with a lumbar fracture (p = 0.03). An A.3.1 fracture only had about a third of the probability for average pain relief compared with an A.1.1 fracture (p = 0.004). Cement volumes up to 4.5 ml only had an approximately 40 % chance for a minimum 41-point pain alleviation as compared with cement volumes of at least 4.5 ml (p = 0.007). In addition, the relationship between cement volume and pain alleviation followed a dose-dependent pattern. Conclusions Cement volume was revealed as a significant predictor for pain relief in BKP. Cement volume was the third most important influential covariate and the most important modifiable and operator dependent one. The clear dose-outcome relationship between cement filling volumes and pain relief additionally supports these findings. Cement volumes of [4.5 ml seem to be recommendable for achieving relevant pain alleviation. Patient sex and fracture type and location were further significant predictors and all these covariates should be recorded and reported in future studies about the pain alleviating effectiveness of vertebral augmentation procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a multicenter, randomized, controlled, open-label, parallel- group trial hyaluronic acid vaginal gel (Hyalofemme) was compared to estriol vaginal cream (Ovestin) in women with vaginal dryness due to various causes. A total of 144 supposedly postmenopausal women below age 70 years were randomized in a 1:1 ratio to either receive hyaluronic acid vaginal gel (5 g per application) or estriol vaginal cream (0.5 g cream per application = 0.5 mg estriol) every 3 days for a total of ten applications, respectively. Exclusion criteria included vaginal infections, conventional contraindications to estrogens, use of vaginal products other than the investigational compounds, being unmarried, pregnant, or breastfeeding. The aim of the study was to test for non-inferiority of hyaluronic acid vaginal gel compared to estriol vaginal cream. The primary efficacy end point was the percentage (%) improvement in vaginal dryness, with the secondary end points being the percentage (%) improvements in vaginal itching, burning, and dyspareunia. Efficacy was assessed by using a visual analog scale (VAS) (0-10; 0 = absent, 10 = intolerable) at baseline (V0), during telephone contact after the third administration (V1), and at the final visit after the tenth administration (V2). Safety parameters included vaginal pH, endometrial thickness, and a vaginal smear for vaginal microecosystem assessment. Adverse events were recorded according to international guidelines. 133 women completed the study. At baseline, participants' characteristics did not differ significantly. Mean age was 54 years, time since menopause was 5 years on average, and cause of menopause was mostly natural. However, mean menstrual cycle days were also reported, although according to inclusion criteria only postmenopausal women were eligible for the study. At V1, an improvement in vaginal dryness was reported by about 49 % of women using hyaluronic acid vaginal gel, and by 53 % of women using estriol vaginal cream (p = 0.31). At V2, the percentage improvement rates were 84 and 89 % (p = 0.13), respectively. Improvement rates for vaginal itching, burning, and dyspareunia at V2 were about 86, 85, and 57 % for hyaluronic acid vaginal gel, and 82, 87, and 62 % for estriol vaginal cream (p[0.05), respectively. After treatment, vaginal pH was significantly lower in estriol-treated women compared to those having received hyaluronic acid. Endometrial thickness did not differ between groups. In the majority of women, the vaginal microenvironment remained unaffected by treatment. However, the proportion of women whose abnormal vaginal microecological results became normal was higher in women using estriol vaginal cream. Adverse events (suspected to be) related to the investigational compounds were minor and included vaginal infection and genital itching. The authors concluded that hyaluronic acid vaginal gel was not inferior to estriol vaginal cream in women presenting with vaginal dryness. They suggest using hyaluronic acid vaginal gel not only as an alternative treatment to vaginal estrogens, but also to consider its general use in women presenting with vaginal dryness of any cause.