815 resultados para reliability of delivery


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The evaluation of children's statements of sexual abuse cases in forensic cases is critically important and must and reliable. Criteria-based content analysis (CBCA) is the main component of the statement validity assessment (SVA), which is the most frequently used approach in this setting. This study investigated the inter-rater reliability (IRR) of CBCA in a forensic context. Three independent raters evaluated the transcripts of 95 statements of sexual abuse. IRR was calculated for each criterion, total score, and overall evaluation. The IRR was variable for the criteria, with several being unsatisfactory. But high IRR was found for the total CBCA scores (Kendall's W = 0.84) and for overall evaluation (Kendall's W = 0.65). Despite some shortcomings, SVA remains a robust method to be used in the comprehensive evaluation of children's statements of sexual abuse in the forensic setting. However, the low IRR of some CBCA criteria could justify some technical improvements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY DESIGN: Clinical measurement. PURPOSE: The test-retest reliability of maximal grip strength measurements (MGSM) is examined in subjects for 12 weeks post-stroke together with maximal grip strength recovery and the maximal-grip and upper-extremity strength measurements' relationship with capacity and performance test scores. METHODS: A Jamar dynamometer and the Motricity Index (MI) were used for strength measurements. The Chedoke Arm and Hand Activity Inventory and ABILHAND questionnaire for evaluating capacities and performances. RESULTS: MGSM were reliable (Intraclass Correlation Coefficients = 0.97-0.99, Minimal Detectable Differences = 2.73-4.68 kg). Among the 34 participants, 47% did not have a measurable grip strength one week post-stroke but 50% of these recovered some strength within the first eight weeks. The MGSM and MI scores were correlated with scores of tests of capacity and performance (Spearman's Rank Correlation Coefficients = 0.69-0.94). CONCLUSIONS: MGSM are reliable in the first weeks after a stroke. LEVEL OF EVIDENCE: N/A.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective The present study evaluated the reliability of digital panoramic radiography in the diagnosis of carotid artery calcifications. Materials and Methods Thirty-five patients under high-risk for development of carotid artery calcifications who had digital panoramic radiography were referred to undergo ultrasonography. Thus, 70 arteries were assessed by both methods. The main parameters utilized to evaluate the panoramic radiography reliability in the diagnosis of carotid artery calcifications were accuracy, sensitivity, specificity and positive predictive value of this method as compared with ultrasonography. Additionally, the McNemar's test was utilized to verify whether there was a statistically significant difference between digital panoramic radiography and ultrasonography. Results Ultrasonography demonstrated carotid artery calcifications in 17 (48.57%) patients. Such individuals presented with a total of 29 (41.43%) carotid arteries affected by calcification. Radiography was accurate in 71.43% (n = 50) of cases evaluated. The degree of sensitivity of this method was 37.93%, specificity of 95.12% and positive predictive value of 84.61%. A statistically significant difference (p < 0.001) was observed between the methods evaluated in their capacity to diagnose carotid artery calcifications. Conclusion Digital panoramic radiography should not be indicated as a method of choice in the investigation of carotid artery calcifications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The work aims to analyze the possibilities of utilizing old crane driving AC induction motors in modern pulse-width-modulated variable frequency drives. Bearing currents and voltage stresses are the two main problems associated with modern IGBT inverters, and they may cause premature failure of an old induction motor. The origins of these two problems are studied. An analysis of the mechanism of bearing failure is proposed. Certain types of bearing currents are considered in detail. The most effective and economical means are chosen for bearing currents mitigation. Transient phenomena of cables and mechanism of over voltages occurring at motor terminals are studied in the work. The weakest places of the stator winding insulation system are shown and recommendations are given considering the mitigation of voltage stresses. Only the most appropriate and cost effective preventative methods are chosen for old motor drives. Rewinding of old motors is also considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Effective treatment for breast cancer requires accurate preoperative planning, developing and implementing a consistent definition of margin clearance, and using tools that provide detailed real-time intraoperative information on margin status. Intraoperative ultrasound (IOUS) may fulfil these requirements and may offer few advantages that other preoperative localization and intraoperative margin assessment techniques may notPurpose: The goal of the present work is to determine how accurate the intraoperative ultrasound should be to acquire complete surgical excision with negative histological margins in patients undergoing Breast Conservative SurgeryDesign: A diagnostic test study with a cross-sectional design carried out in a tertiary referral hospital in Girona within a Breast Pathology UnitParticipants: Women diagnosed with breast cancer undergoing a Breast Conservative Surgery in the Breast Pathology Unit at Hospital Universitari de Girona Dr. Josep Trueta

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Finnish electricity distribution sector, rural areas in particular, is facing major challenges because of the economic regulation, tightening supply security requirements and the ageing network asset. Therefore, the target in the distribution network planning and asset management is to develop and renovate the networks to meet these challenges in compliance with the regulations in an economically feasible way. Concerning supply security, the new Finnish Electricity Market Act limits the maximum duration of electricity supply interruptions to six hours in urban areas and 36 hours in rural areas. This has a significant impact on distribution network planning, especially in rural areas where the distribution networks typically require extensive modifications and renovations to meet the supply security requirements. This doctoral thesis introduces a methodology to analyse electricity distribution system development. The methodology is based on and combines elements of reliability analysis, asset management and economic regulation. The analysis results can be applied, for instance, to evaluate the development of distribution reliability and to consider actions to meet the tightening regulatory requirements. Thus, the methodology produces information for strategic decision-making so that DSOs can respond to challenges arising in the electricity distribution sector. The key contributions of the thesis are a network renovation concept for rural areas, an analysis to assess supply security, and an evaluation of the effects of economic regulation on the strategic network planning. In addition, the thesis demonstrates how the reliability aspect affects the placement of automation devices and how the reserve power can be arranged in a rural area network.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cesarean section (CS) is the most common major surgery performed on women worldwide. CS can save the life of the mother or the fetus, but is associated with the typical complications of any major surgery: hemorrhage, infection, venous thromboembolism and complications of anesthesia, sometimes leading to maternal death. Recently there have been several reports from well resourced countries on increased severe maternal morbidity and even mortality. Increased rates of CS, obesity and older mothers may explain this rise. The aim of this thesis is to study the rates and risk factors of short term maternal complications associated with CS. Also, we compared maternal morbidity by mode of delivery and over time. The complication rates were assessed in a prospective study involving 2496 CS performed in the 12 largest delivery units in Finland in 2005. The rates of severe complications were studied by mode of delivery in a register-based study comparing national cohorts in 1997 and 2002. The impact of several risk factors on severe maternal morbidity by mode of delivery was studied in a register-based study of all singleton deliveries in 2007-2011. In the prospective study, 27% of the women who underwent CS had one or more intraoperative or postoperative complications during their hospital stay, and 10% had a severe complication. In the register-based study the incidence of life-threatening maternal complications was 7.6 in 1000 deliveries. The incidence was lowest for vaginal delivery (VD), followed by instrumental VD and elective CS, and highest in emergency CS. An attempt of VD, including the risks associated with emergency CS, seems to be the safest mode of delivery, even for most high-risk women.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of the present study was to determine the reliability of the Brazilian version of the Composite International Diagnostic Interview 2.1 (CIDI 2.1) in clinical psychiatry. The CIDI 2.1 was translated into Portuguese using WHO guidelines and reliability was studied using the inter-rater reliability method. The study sample consisted of 186 subjects from psychiatric hospitals and clinics, primary care centers and community services. The interviewers consisted of a group of 13 lay and three non-lay interviewers submitted to the CIDI training. The average interview time was 2 h and 30 min. General reliability ranged from kappa 0.50 to 1. For lifetime diagnoses the reliability ranged from kappa 0.77 (Bipolar Affective Disorder) to 1 (Substance-Related Disorder, Alcohol-Related Disorder, Eating Disorders). Previous year reliability ranged from kappa 0.66 (Obsessive-Compulsive Disorder) to 1 (Dissociative Disorders, Maniac Disorders, Eating Disorders). The poorest reliability rate was found for Mild Depressive Episode (kappa = 0.50) during the previous year. Training proved to be a fundamental factor for maintaining good reliability. Technical knowledge of the questionnaire compensated for the lack of psychiatric knowledge of the lay personnel. Inter-rater reliability was good to excellent for persons in psychiatric practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of the present study was to translate, adapt and validate a Brazilian Portuguese version of the Disabilities of the Arm, Shoulder and Hand (DASH) Questionnaire. The study was carried out in two steps. The first was to translate the DASH into Portuguese and to perform cultural adaptation and the second involved the determination of the reliability and validity of the DASH for the Brazilian population. For this purpose, 65 rheumatoid arthritis patients of either sex (according to the classification criteria of the American College of Rheumatology), ranging in age from 18 to 60 years and presenting no other diseases involving the upper limbs, were interviewed. The patients were selected consecutively at the rheumatology outpatient clinic of UNIFESP. The following results were obtained: in the first step (translation and cultural adaptation), all patients answered the questions. In the second step, Spearman's correlation coefficients for interobserver evaluation ranged from 0.762 to 0.995, values considered to be highly reliable. In addition, intraclass correlation coefficients ranged from 0.97 to 0.99, also highly reliable values. Spearman's correlation coefficients and the intraclass correlation coefficients obtained during intra-observer evaluation ranged from 0.731 to 0.937 and from 0.90 to 0.96, respectively, being highly reliable values. The Ritchie Index showed a weak correlation with Brazilian DASH scores, while the visual analog scale of pain showed a good correlation with DASH score. We conclude that the Portuguese version of the DASH is a reliable instrument.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In a cross-sectional study conducted four years ago to assess the validity of the Brazilian version of the Eating Attitudes Test-26 (EAT-26) for the identification of abnormal eating behaviors in a population of young females in Southern Brazil, 56 women presented abnormal eating behavior as indicated by the EAT-26 and the Edinburgh Bulimic Investigation Test. They were each matched for age and neighborhood to two normal controls (N = 112) and were re-assessed four years later with the two screening questionnaires plus the Composite International Diagnostic Interview (CIDI). The EAT results were then compared to diagnoses originating from the CIDI. To evaluate the temporal stability of the two screening questionnaires, a test-retest design was applied to estimate kappa coefficients for individual items. Given the prevalence of eating disorders of 6.2%, the CIDI psychiatry interview was applied to 161 women. Of these, 0.6% exhibited anorexia nervosa and 5.6%, bulimia nervosa (10 positive cases). The validity coefficients of the EAT were: 40% sensitivity, 84% specificity, and 14% positive predictive value. Cronbach's coefficient was 0.75. For each EAT item, the kappa index was not higher than 0.344 and the correlation coefficient was lower than 0.488. We conclude that the EAT-26 exhibited low validity coefficients for sensitivity and positive predictive value, and showed a poor temporal stability. It is reasonable to assume that these results were not influenced by the low prevalence of eating disorders in the community. Thus, the results cast doubts on the ability of the EAT-26 test to identify cases of abnormal eating behaviors in this population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m² mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.