922 resultados para radial chromatography
Resumo:
The loss rate of linear momentum from a binary system composed of compact objects (radially falling towards each other under mutual gravitational influence) has been investigated using the multipolar post-Minkowskian approach. The 2.5PN accurate analytical formula for the linear momentum flux is provided, in terms of the separation of the two objects, in harmonic coordinates, both for a finite and an infinite initial separation. The 2.5PN formulas for the linear momentum flux are finally used to estimate the recoil velocity accumulated during a premerger phase of the binary evolution.
Resumo:
A sensitive and selective liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method was developed to determine olanzapine (OLZ) in human urine. After solid-phase extraction with SPE cartridge, the urine sample was analysed on a C-18 column (Symmetry 3.5 mu m, 50 x 4.6 mm i.d) interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of ammonium acetate (pH 7.8)-acetonitrile (10:90, v/v). The method was linear over a concentration range of 1-100 ngml(-1). The lower limit of quantitation was 1 ngml(-1). The intra-day and inter-day relative standard deviation across three validation runs over the entire concentration range was < 11.5 %. The accuracy determined at three concentrations (8.0, 50.0 and 85.0 ngml(-1) OLZ) was within +/- 1.21 % in terms of relative errors.
Resumo:
Classical literature on solid mechanics claims existence of radial deformation due to torsion but there is hardly any literature on analytic solutions capturing this phenomenon. This paper tries to solve this problem in an asymptotic sense using the variational asymptotic method (VAM). The method makes no ad hoc assumptions and hence asymptotic correctness is assured. The VAM splits the 3D elasticity problem into two parts: A 1D problem along the length of the cylinder which gives the twist and a 2D cross-sectional problem which gives the radial deformation. This enables closed form solutions, even for some complex problems. Starting with a hollow cylinder, made up of orthotropic but transversely isotropic material, the 3D problem has been formulated and solved analytically despite the presence of geometric nonlinearity. The general results have been specialized for particularly useful cases, such as solid cylinders and/or cylinders with isotropic material. DOI: 10.1115/1.4006803]
Resumo:
Fastest curve-fitting procedures are proposed for vertical and radial consolidations for rapid loading methods. In vertical consolidation, the next load increment can be applied at 50-60% consolidation (or even earlier if the compression index is known). In radial consolidation, the next load increment can be applied at just 10-15% consolidation. The effects of secondary consolidation on the coefficient of consolidation and ultimate settlement are minimized in both cases. A quick procedure is proposed in vertical consolidation that determines how far is calculated from the true , where is coefficient of consolidation. In radial consolidation no such procedure is required because at 10-15% the consolidation effects of secondary consolidation are already less in most inorganic soils. The proposed rapid loading methods can be used when the settlement or time of load increment is not known. The characteristic features of vertical, radial, three-dimensional, and secondary consolidations are given in terms of the rate of settlement. A relationship is proposed between the coefficient of the vertical consolidation, load increment ratio, and compression index. (C) 2013 American Society of Civil Engineers.
Resumo:
The present work reports the compositional analysis of thirteen different packed fruit juices using high performance liquid chromatography (HPLC). Vitamin C, organic acids (citric and malic) and sugars (fructose, glucose and sucrose) were separated, analyzed and quantified using different reverse phase methods. A new rapid reverse phase HPLC method was developed for routine analysis of vitamin C in fruit juices. The precision results of the methods showed that the relative standard deviations of the repeatability and reproducibility were < 0.05 and < 0.1 respectively. Correlation coefficient of the calibration models developed was found to be higher than 0.99 in each case. It has been found that the content of Vitamin C was less variable amongst different varieties involved in the study. It is also observed that in comparison to fresh juices, the packed juices contain lesser amounts of vitamin C. Citric acid was found as the major organic acids present in packed juices while maximum portion of sugars was of sucrose. Comparison of the amount of vitamin C, organic acids and sugars in same fruit juice of different commercial brands is also reported.
Resumo:
We prove end point estimate for Radon transform of radial functions on affine Grasamannian and real hyperbolic space. We also discuss analogs of these results on the sphere.
Resumo:
Differential mobility analyzers (DMAs) are commonly used to generate monodisperse nanoparticle aerosols. Commercial DMAs operate at quasi-atmospheric pressures and are therefore not designed to be vacuum-tight. In certain particle synthesis methods, the use of a vacuum-compatible DMA is a requirement as a process step for producing high-purity metallic particles. A vacuum-tight radial DMA (RDMA) has been developed and tested at low pressures. Its performance has been evaluated by using a commercial NANO-DMA as the reference. The performance of this low-pressure RDMA (LP-RDMA) in terms of the width of its transfer function is found to be comparable with that of other NANO-DMAs at atmospheric pressure and is almost independent of the pressure down to 30 mbar. It is shown that LP-RDMA can be used for the classification of nanometer-sized particles (5-20 nm) under low pressure condition (30 mbar) and has been successfully applied to nanoparticles produced by ablating FeNi at low pressures.
Resumo:
In the present work, we report a novel, in vivo, noninvasive technique to determine radial arterial compliance using the radial arterial pressure pulse waveform (RAPPW) acquired by fiber Bragg grating pulse recorder (FBGPR). The radial arterial compliance of the subject can be measured during sphygmomanometric examination by the unique signatures of arterial diametrical variations and the beat-to-beat pulse pressure acquired simultaneously from the RAPPW recorded using FBGPR. This proposed technique has been validated against the radial arterial diametrical measurements obtained from the color Doppler ultrasound. Two distinct trials have been illustrated in this work and the results from both techniques have been found to be in good agreement with each other.
Resumo:
A new successive displacement type load flow method is developed in this paper. This algorithm differs from the conventional Y-Bus based Gauss Seidel load flow in that the voltages at each bus is updated in every iteration based on the exact solution of the power balance equation at that node instead of an approximate solution used by the Gauss Seidel method. It turns out that this modified implementation translates into only a marginal improvement in convergence behaviour for obtaining load flow solutions of interconnected systems. However it is demonstrated that the new approach can be adapted with some additional refinements in order to develop an effective load flow solution technique for radial systems. Numerical results considering a number of systems-both interconnected and radial, are provided to validate the proposed approach.
Resumo:
In this paper, we propose a H.264/AVC compressed domain human action recognition system with projection based metacognitive learning classifier (PBL-McRBFN). The features are extracted from the quantization parameters and the motion vectors of the compressed video stream for a time window and used as input to the classifier. Since compressed domain analysis is done with noisy, sparse compression parameters, it is a huge challenge to achieve performance comparable to pixel domain analysis. On the positive side, compressed domain allows rapid analysis of videos compared to pixel level analysis. The classification results are analyzed for different values of Group of Pictures (GOP) parameter, time window including full videos. The functional relationship between the features and action labels are established using PBL-McRBFN with a cognitive and meta-cognitive component. The cognitive component is a radial basis function, while the meta-cognitive component employs self-regulation to achieve better performance in subject independent action recognition task. The proposed approach is faster and shows comparable performance with respect to the state-of-the-art pixel domain counterparts. It employs partial decoding, which rules out the complexity of full decoding, and minimizes computational load and memory usage. This results in reduced hardware utilization and increased speed of classification. The results are compared with two benchmark datasets and show more than 90% accuracy using the PBL-McRBFN. The performance for various GOP parameters and group of frames are obtained with twenty random trials and compared with other well-known classifiers in machine learning literature. (C) 2015 Elsevier B.V. All rights reserved.
Resumo:
One of the commonly used resins for immobilized metal affinity purification of polyhistidine-tagged recombinant proteins is TALON resin, a cobalt (II)--carboxymethylaspartate-based matrix linked to Sepharose CL-6B. Here, we show that TALON resin efficiently purifies the native form of Lac repressor, which represents the major contaminant when (His)(6)-tagged proteins are isolated from Escherichia coli host cells carrying the lacI(q) gene. Inspection of the crystal structure of the repressor suggests that three His residues (residues 163, 173, and 202) in each subunit of the tetramer are optimally spaced on an exposed face of the protein to allow interaction with Co(II). In addition to establishing a more efficient procedure for purification of the Lac repressor, these studies indicate that non-lacI(q)-based expression systems yield significantly purer preparations of recombinant polyhistidine-tagged proteins.