1000 resultados para química analítica


Relevância:

60.00% 60.00%

Publicador:

Resumo:

New methodologies for the analysis of volatile compoundsusing needle traps. Applications to breath, atmospheric andwater analysis. A new preconcentration technique has been developed for the analysis of volatile compounds based on the use of needle traps. These traps are based on stainless steel needles filled with one or more adsorbents, which allows the preconcentration of the anilities inside the trap by passing a gas flow through the needle. The parameters affecting the sorption/desorption process have been assessed (e.g. needle and liner dimensions, injector temperature, split less time, memory effects, and stability inside the needle). For liquid samples, four different sampling methodologies were studied, including passive and active sampling methods. The best results, considering the simplicity and sensitivity, are obtained by sampling the headspace volume using various cycles of a small and fix volume. Once the best conditions of analysis have been found, the method has been validated for gas and liquid samples. The results obtained show that needle traps are a good analytical methodology for the analysis of breath, environmental and liquid samples

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A beautiful smile is directly related with white teeth. Nowadays oral care has increased and developed processes for beautiful smiles. Dental bleaching is frequently used in odontology, not just for health care also for aesthetic treatment. With the possibility of teeth bleaching, now the importance is in, how white the tooth is? Because color is relate to an individual perception. In order to assets teeth correct color identification has been developed many color guides, models, spaces and analytical methods. Spite all of these useful tools the color interpretation depends on environmental factors, position of the sample in the data acquisition and most importantly the instrument sensitivity. The commons methods have proved to be useful. They are easy to handle, some are portable but they do not have a high sensitivity. The present work is based on the integration of a new analytical technique for color acquisition. High spectral Image (HSI) is able to performed image analysis with high quality and efficiency. HSI is used in many fields and we used it for color image analysis within the bleaching process. The main comparison was done with the HSI and the colorimeter through the processes of two different bleaching protocols. The results showed that HSI has higher sensitivity than the colorimeter. During the analysis the dental surface with the HSI we were able to notice surface changes. These changes were analyzed by roughness studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of iodine as a catalyst and either acetic or trifluoroacetic acid as a derivatizing reagent for determining the enantiomeric composition of acyclic and cyclic aliphatic chiral alcohols was investigated. Optimal conditions were selected according to the molar ratio of alcohol to acid, the reaction time, and the reaction temperature. Afterwards, chiral stability of chiral carbons was studied. Although no isomerization was observed when acetic acid was used, partial isomerization was detected with the trifluoroacetic acid. A series of chiral alcohols of a widely varying structural type were then derivatized with acetic acid using the optimal conditions. The resolution of the enantiomeric esters and the free chiral alcohols was measured using a capillary gas chromatograph equipped with a CP Chirasil-DEX CB column. The best resolutions were obtained with 2-pentyl acetates (α = 3.00) and 2-hexyl acetates (α = 1.95). This method provides a very simple and efficient experimental workup procedure for analyzing chiral alcohols by chiral-phase GC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The influence of storage time and temperature on Sb migration from PET bottles into mineral water was studied in short-term tests lasting up to 15 days and long-term studies lasting up to 220 days. Samples purchased were stored in three different coloured bottles: clear (CL), light blue (LB) and dark blue (DB). Sb migration was assayed by HG-AFS for total determination and HPLC-ICP-MS for speciation analysis. Migration studies showed that waters stored at 4 and 20 oC were not subject to Sb migration. At 40 oC there was a significant increase in Sb concentration, although the maximum limit established by the European Union (5.0 ug/L) was not exceeded, whereas at 60 oC samples were subject to considerable Sb migration after 30 days of storage. In this case, the maximum limit established by the European Union was exceeded and both Sb (V) and Sb (III) were detected.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper reports the method development for the simultaneous determination of methylmercury MeHgþ) and inorganic mercury (iHg) species in seafood samples. The study focused on the extraction and quantification of MeHgþ (the most toxic species) by liquid chromatography coupled to on-line UV irradiation and cold vapour atomic fluorescence spectroscopy (LC-UV-CV-AFS), using HCl 4 mol/L as the extractant agent. Accuracy of the method has been verified by analysing three certified reference materials and different spiked samples. The values found for total Hg and MeHgþ for the CRMs did not differ significantly from certified values at a 95% confidence level, and recoveries between 85% and 97% for MeHgþ, based on spikes, were achieved. The detection limits (LODs) obtained were 0.001 mg Hg/kg for total mercury, 0.0003 mg Hg/kg for MeHgþ and 0.0004 mg Hg/kg for iHg. The quantification limits (LOQs) established were 0.003 mg Hg/kg for total mercury, 0.0010 mg Hg/kg for MeHgþ and 0.0012 mg Hg/kg for iHg. Precision for each mercury species was established, being 12% in terms of RSD in all cases. Finally, the developed method was applied to 24 seafood samples from different origins and total mercury contents. The concentrations for Total Hg, MeHg and iHg ranged from 0.07 to 2.33, 0.003-2.23 and 0.006-0.085 mg Hg/kg, respectively. The established analytical method allows to obtain results for mercury speciation in less than 1 one hour including both, sample pretreatment and measuring step.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There is an increasing interest in the use of breath analysis for monitoring human physiology and exposure to toxic substances or environmental pollutants. This review focuses on the current status of the sampling procedures, collection devices and sample-enrichment methodologies used for exhaled breath-vapor analysis. We discuss the different parameters affecting each of the above steps, taking into account the requirements for breath analysis in exposure assessments and the need to analyze target compounds at sub-ppbv levels. Finally, we summarize the practical applications of exposure analysis in the past two decades

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new analytical method was developed to non-destructively determine pH and degree of polymerisation (DP) of cellulose in fibres in 19th 20th century painting canvases, and to identify the fibre type: cotton, linen, hemp, ramie or jute. The method is based on NIR spectroscopy and multivariate data analysis, while for calibration and validation a reference collection of 199 historical canvas samples was used. The reference collection was analysed destructively using microscopy and chemical analytical methods. Partial least squares regression was used to build quantitative methods to determine pH and DP, and linear discriminant analysis was used to determine the fibre type. To interpret the obtained chemical information, an expert assessment panel developed a categorisation system to discriminate between canvases that may not be fit to withstand excessive mechanical stress, e.g. transportation. The limiting DP for this category was found to be 600. With the new method and categorisation system, canvases of 12 Dalí paintings from the Fundació Gala-Salvador Dalí (Figueres, Spain) were non-destructively analysed for pH, DP and fibre type, and their fitness determined, which informs conservation recommendations. The study demonstrates that collection-wide canvas condition surveys can be performed efficiently and non-destructively, which could significantly improve collection management.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este trabalho descreve uma revisão a respeito do uso do ligante dietilditiofosfato de amônio em química analítica e suas potencialidades no campo da análise química espectrofotométrica (UV/VIS) e espectrométrica (AAS, ICP-AES, ICP-MS) em diferentes matrizes e meios. A discriminação de espécies químicas por meio de complexações seletivas de elementos químicos com dietilditiofosfato e a hifenação de técnicas espectroscópicas a etapas de separação como extração em fase sólida, extração líquido-líquido, extração por "cloud point", são outros assuntos abordados neste trabalho.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias con Especialidad en Química Analítica Biomédica) UANL

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias con Especialidad en Química Analítica Biomédica) UANL

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias, con Especialidad en Química Analítica) UANL

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias Químicas con Especialidad en Química Analítica) UANL

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias Químicas con Especialidad en Química Analítica) UANL

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias con Especialidad en Química Analítica) UANL