970 resultados para polarimetric SAR


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The SAR of a series of new epothilone A derivatives with a 2-substituted-1,3-oxazoline moiety trans-fused to the C12-C13 bond of the deoxy macrocycle have been investigated with regard to tubulin polymerization induction and cancer cell growth inhibition. Significant differences in antiproliferative activity were observed between different analogs, depending on the nature of the substituent at the 2-position of the oxazoline ring. The most potent compounds showed comparable activity with the natural product epothilone A. Modeling studies provide a preliminary rationale for the observed SAR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several natural products derived from entomopathogenic fungi have been shown to initiate neuronal differentiation in the rat pheochromocytoma PC12 cell line. After the successful completion of the total synthesis program, the reduction of structural complexity while retaining biological activity was targeted. In this study, farinosone C served as a lead structure and inspired the preparation of small molecules with reduced complexity, of which several were able to induce neurite outgrowth. This allowed for the elaboration of a detailed structure-activity relationship. Investigations on the mode of action utilizing a computational similarity ensemble approach suggested the involvement of the endocannabinoid system as potential target for our analogs and also led to the discovery of four potent new endocannabinoid transport inhibitors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Samuel Poznanski

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scholars have found that socioeconomic status was one of the key factors that influenced early-stage lung cancer incidence rates in a variety of regions. This thesis examined the association between median household income and lung cancer incidence rates in Texas counties. A total of 254 individual counties in Texas with corresponding lung cancer incidence rates from 2004 to 2008 and median household incomes in 2006 were collected from the National Cancer Institute Surveillance System. A simple linear model and spatial linear models with two structures, Simultaneous Autoregressive Structure (SAR) and Conditional Autoregressive Structure (CAR), were used to link median household income and lung cancer incidence rates in Texas. The residuals of the spatial linear models were analyzed with Moran's I and Geary's C statistics, and the statistical results were used to detect similar lung cancer incidence rate clusters and disease patterns in Texas.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional SAR (Synthetic Aperture Radar) techniques only consider a single reflection of transmitted waveforms from targets. Nevertheless, today?s new applications force SAR systems to work in much more complex scenes such as urban environments. As a result, multiple-bounce returns are additionally superposed to direct echoes. We refer to these as ghost images, since they obscure true target image and lead to poor resolution. By applying Time Reversal concept to SAR imaging (TR-SAR), it is possible to reduce considerably ?or almost mitigate? ghosting artifacts, recovering the lost resolution due to multipath effects. Furthermore, some focusing indicators such as entropy (E), contrast (C) and Rényi entropy (RE) provide us a good focusing criterion when using TR-SAR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El proyecto trata del estudio de la tasa de absorción específica (SAR). En él se estudia la SAR que desprenden distintos dispositivos de comunicaciones inalámbricos. Se ha llevado a cabo en las instalaciones de la SETSI, en el laboratorio de radiofrecuencia situado en El Casar, Guadalajara, que pertenece al Ministerio de Industria Comercio y Turismo. La SAR es una relación entre la energía electromagnética acumulada en una masa de un material o tejido concreto. Por tanto, lo primero es definir la SAR, en la que se exponen sus parámetros. Además, se recogen los límites de exposición fijados por las normas internacionales IEC 62209-1 e IEC 62209-2 en relación a SAR. Posteriormente, acorde con las normas, se realiza una definición detallada de un banco de medidas de SAR, en donde se explica cada uno de los componentes del banco de manera detallada así como los sistemas que intervienen previamente a la realización de la medida, tipos de los sistemas para realizar las verificaciones pertinentes, y también las incertidumbres de ciertos parámetros. También se realiza un proceso completo de medida de SAR en el laboratorio de la SETSI, donde se realizan las comprobaciones necesarias para la realización de una serie de medidas sobre dispositivos de comunicaciones móviles. Éstas medidas se realizan primero sobre un teléfono móvil en las frecuencias de GSM, UMTS y WIFI, en las configuraciones estipuladas por la norma; “tocando” e “inclinada 15°” comparando los valores obtenidos con los límites marcados por las normas internacionales. Por último, en este apartado se realizan ciertas medidas con otras configuraciones que no están recogidas en la norma para intentar obtener los máximos valores de SAR posibles. Después se realiza una comparación entre dos dispositivos tipo “tablet”, para ello se realizan medidas en la banda de WIFI y se comentan los resultados obtenidos, relacionado con el diseño de cada uno de ellos. Posteriormente se realiza un presupuesto de un banco de SAR, donde se detallan todos los componentes que intervienen en la realización de las medidas de SAR, pero no se incluyen en él, los costes de mantenimiento o los costes relacionados con su uso. Por último se explican las conclusiones finales desprendidas de la realización de este proyecto de fin de carrera así como la bibliografía utilizada. ABTRACT This project consists on the study of the specific absorption rate (SAR).It studies the different SAR of several wireless communications devices. It has been held in SETSI’S facilities, in its radio frecuency laboratory located in El Casar, Guadalajara, which belongs to the Ministy of Industry, Trade and Tourism. The SAR is a ratio between the electromagnetic energy accumulated in a mass of concrete material or tissue. Therefore, the SAR is defined first, which sets its parameters. Also lists the exposure limits set by international standards IEC 62209-1 and IEC 62209-2 regarding SAR. Subsequently, according to the guidelines, performing a detailed definition of a SAR measures bench, which explains each of the components in detail of the bench and involved systems prior to the realization of the extent and types of systems to perform the necessary checks, and certain parameters uncertainties. Also performed a complete process for SAR in the SETSI laboratory, located in El Casar, Guadalajara, where the necessary checks are made to carry out a serie of measures on mobile communications devices. These will be carried out first on a mobile phone at frequencies of GSM, UMTS and WiFi, in the configurations set by the standard, "touch" and "tilt 15 °" comparing the values obtained with the limits set by international standards. Finally, this section will perform certain actions with other configurations that are not included in the standard to try to get the maximum possible SAR values. Then a comparison is made between two devices, such as "tablet", this will make measurements in the band WIFI and discussed the results, related to the design of each. Subsequently, a budget of a SAR bench, detailing all components involved in SAR measures, but not included in it, maintenance costs or the costs associated with its use. Finally conclusions are explained detached from the realization of this project as well as the bibliography used on it.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foliage Penetration (FOPEN) radar systems were introduced in 1960, and have been constantly improved by several organizations since that time. The use of Synthetic Aperture Radar (SAR) approaches for this application has important advantages, due to the need for high resolution in two dimensions. The design of this type of systems, however, includes some complications that are not present in standard SAR systems. FOPEN SAR systems need to operate with a low central frequency (VHF or UHF bands) in order to be able to penetrate the foliage. High bandwidth is also required to obtain high resolution. Due to the low central frequency, large integration angles are required during SAR image formation, and therefore the Range Migration Algorithm (RMA) is used. This project thesis identifies the three main complications that arise due to these requirements. First, a high fractional bandwidth makes narrowband propagation models no longer valid. Second, the VHF and UHF bands are used by many communications systems. The transmitted signal spectrum needs to be notched to avoid interfering them. Third, those communications systems cause Radio Frequency Interference (RFI) on the received signal. The thesis carries out a thorough analysis of the three problems, their degrading effects and possible solutions to compensate them. The UWB model is applied to the SAR signal, and the degradation induced by it is derived. The result is tested through simulation of both a single pulse stretch processor and the complete RMA image formation. Both methods show that the degradation is negligible, and therefore the UWB propagation effect does not need compensation. A technique is derived to design a notched transmitted signal. Then, its effect on the SAR image formation is evaluated analytically. It is shown that the stretch processor introduces a processing gain that reduces the degrading effects of the notches. The remaining degrading effect after processing gain is assessed through simulation, and an experimental graph of degradation as a function of percentage of nulled frequencies is obtained. The RFI is characterized and its effect on the SAR processor is derived. Once again, a processing gain is found to be introduced by the receiver. As the RFI power can be much higher than that of the desired signal, an algorithm is proposed to remove the RFI from the received signal before RMA processing. This algorithm is a modification of the Chirp Least Squares Algorithm (CLSA) explained in [4], which adapts it to deramped signals. The algorithm is derived analytically and then its performance is evaluated through simulation, showing that it is effective in removing the RFI and reducing the degradation caused by both RFI and notching. Finally, conclusions are drawn as to the importance of each one of the problems in SAR system design.