993 resultados para piñón


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the clinical and radiographic outcome in 8 dogs of surgical reduction of congenital humeroulnar luxation by using the transarticular pin. Five cases were bilateral and 3 were unilateral, for a total of 13 elbows. The treatment was performed in animals between 45 and 150 days of age. Articular stabilization was achieved by using a transarticular pin driven from the caudal aspect of the olecranon into the body of the humerus or into the distal condyle and distal metaphysis of the humerus. The follow-up period was between 1 and 19 months. There were 5 postsurgical reluxations, 3 related to the insertion of the pin into the humeral condyle and 3 related to the insertion into the humeral body. These animals needed further surgery. Six animals showed near normal return to limb function and 2 had lameness. We conclude that the use of the transarticular pin is an effective and simple method for the treatment of humeroulnar congenital elbow luxation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As reflexões múltiplas presentes nos sismogramas ocultam informações importantes sobre os refletores em subsuperfície e, podem até tornar completamente invisíveis as reflexões primárias, como no caso dos sismogramas marinhos, que muitas das vezes, exibem uma aparência anelar com fortes superposições das reflexões múltiplas, sobre as reflexões primárias. Problema este que tem sido alvo de importantes pesquisas, com o intuito de identificar, atenuar e/ou eliminá-las, através de vários métodos populares. O objetivo principal deste trabalho é a identificação das reflexões múltiplas. Com essa finalidade foi gerada, por modelamento direto, uma seção sísmica, com afastamento nulo (AN), contendo reflexões primárias e múltiplas simétricas de primeira ordem. Posteriormente, foi aplicada a migração cinemática do tipo Kirchhoff para obter o modelo em profundidade, apresentando uma boa recuperação dos refletores, bem como a presença de um refletor fictício, quando comparado com a seção anteriormente especificada. Foi obtida uma seção sísmica AN, do modelo migrado, na qual não é observado o segundo refletor, devido à ausência de contraste de impedância, entre a segunda e terceira camada, sendo este o primeiro indício de que o refletor fictício deste modelo é uma múltipla. Outro indício sobre a existência da múltipla foi a simetria encontrada entre as curvaturas do primeiro e terceiro refletor. Finalmente, foram calculados os parâmetros das frentes de ondas Hipotéticas Ponto de Incidência Normal (PIN) e Normal (N), bem como a velocidade Normal Moveout (NMO), tanto para os eventos de reflexões primárias como os eventos de reflexões múltiplas, para o modelo direto e para o modelo migrado. Em seguida, foram realizadas as comparações destes parâmetros, o que permitiu confirmar a veracidade dos indícios anteriores para a identificação das reflexões múltiplas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A superfície oclusal excessivamente desgastada pode resultar em desarmonia oclusal e prejuízo à estética e função. Como abordagem terapêutica, coroas unitárias convencionais têm sido propostas, porém este tipo de tratamento é complexo, altamente invasivo e caro. Este relato de caso descreve os resultados clínicos de um tratamento alternativo minimamente invasivo baseado em restaurações adesivas diretas retidas por pinos. Uma paciente de 64 anos apresentando dentição severamente desgastada, problemas mastigatórios relacionados às ausências dentárias e hipersensibilidade dental generalizada foi encaminhada para tratamento. O adequado plano de tratamento baseado no enceramento diagnóstico foi utilizado para guiar a reconstrução dos dentes anteriores superiores com resina composta direta sobre pinos dentinários auto-rosqueáveis. Como os dentes inferiores remanescentes eram extremamente desgastados, uma sobre-dentadura dento-suportada foi instalada. Uma placa estabilizadora também foi utilizada de modo a proteger as restaurações. Este tratamento constitui uma alternativa mais acessível de reabilitação de boca total com resultados estéticos e funcionais positivos após 1,5 anos de acompanhamento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The steady increase in the price of oil and its derivatives, carbon credits, the concern with the environment combined with the precipitation of rain water and lack of water resources that Brazil has suffered in 2014 caused a migration of participation sources of energy in the Brazilian energy matrix. The hydropower sector suffered big drop at 2013 and is suffering so far, contributing thus to the generation and cogeneration of thermal energy using renewable energy sources such as: sugarcane bagasse, wood chips, rice husks, among others. The selling price of the electricity market reached the level of R$ 807, 00 MWh in January 2014 (Source: ANEEL), heating the Brazilian thermoelectric sector. Although thermoelectric use in bulk water as vaporizing fluid to produce electricity and use in various processes, water reuse plans have become an important factor in these industries. The increased use of biomass has been the bagasse which is allied to the sugarcane sector, strong market in Brazil, and consists basically use the rest of sugar cane, sugarcane industries that would play out. The sugar and ethanol industry is very unstable and only lasts for 6-8 months a year, and the remaining time in the period known as between crop that corresponds to the planting and harvesting of sugarcane and then enter the period of vintage which is the constant cane harvesting and crushing it. This instability of the market and the thermoelectric idle period leads the thermoelectric industries to seek other sources of renewable energy, such as wood chips (pine, Eucalyptus, Orange), rice husk, sorghum among others, to not be dependent on alcohol sector. The present work aims to study the use of wood chips as an alternative biomass for burning a fuel that essentially uses bagasse, the thermoelectric in question consists of two boilers that produce together 350 t / h ... (Complete Abstract click electronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Over the last years, it is known that in some cases metal devices for biomedical applications present some disadvantages suggesting absorbable materials (natural or synthetic) as an alternative of choice. Here, our goal was to evaluate the biological response of a xenogenic pin, derived from bovine cortical bone, intraosseously implanted in the femur of rats. Material and methods: After 10, 14, 30 and 60 days from implantation, the animals (n = 5/period) were killed and the femurs carefully collected and dissected out under histological demands. For identifying the osteoclastogenesis level at 60 days, we performed the immunohistochemisty approach using antibody against RANKL. Results: Interestingly, our results showed that the incidence of neutrophils and leukocytes was observed only at the beginning (10 days). Clear evidences of pin degradation by host cells started at 14 days and it was more intensive at 60 days, when we detected the majority of the presence of giant multinucleated cells, which were very similar to osteoclast cells contacting the implanted pin. To check osteoclastogenesis at 60 days, we evaluated RANKL expression and it was positive for those resident multinucleated cells while a new bone deposition was verified surrounding the pins in all evaluated periods. Conclusions: Altogether, our results showed that pins from fully processed bovine bone are biocompatible and absorbable, allowing bone neoformation and it is a promissory device for biomedical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intensive scheduling in sports requires athletes to resume physical activity shortly after injury. The purpose of this study was to investigate early isokinetic muscle strength and knee function on bone-patellar tendon-bone (BPTB) ACL reconstruction with double femoral pin fixation or interference screw technique. A prospective study was conducted from 2008 to 2009, with 48 athletes who received femoral BPTB fixation with interference screw (n = 26) or double pin (n = 22). Clinical (IKDC objective score and hop test) and isokinetic muscle strength (peak torque (PT), PT/body weight and flexion/extension rate (F/E) in 60 and 240A degrees/s) were analyzed at 6 months of follow-up. Analysis at baseline showed no differences between groups before surgery related to age, gender, associated injury, Tegner or Lysholm score; thus showing that groups were similar. During follow-up, however, there were significant differences between the two groups in some of the isokinetic muscle strength: PT/BW 60A degrees/s (Double Pin = 200% +/- A 13% vs. Interference Screw = 253% +/- A 16%*, *P = 0.01); F/E 60A degrees/s (Double Pin = 89% +/- A 29%* vs. Interference Screw = 74% +/- A 12%, *P = 0.04). No statistical differences between groups were observed on IKDC objective score, hop test and complications. The significant muscle strength outcome of the interference screw group found in this study gives initial evidence that this fixation technique is useful for athletes that may need accelerated rehabilitation. Early return to sports ability signaled by isokinetic muscle strength is of clinical relevance as it is one of the main goals for athletes' rehabilitation. III.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reduction of friction and wear in systems presenting metal-to-metal contacts, as in several mechanical components, represents a traditional challenge in tribology. In this context, this work presents a computational study based on the linear Archard's wear law and finite element modeling (FEM), in order to analyze unlubricated sliding wear observed in typical pin on disc tests. Such modeling was developed using finite element software Abaqus® with 3-D deformable geometries and elastic–plastic material behavior for the contact surfaces. Archard's wear model was implemented into a FORTRAN user subroutine (UMESHMOTION) in order to describe sliding wear. Modeling of debris and oxide formation mechanisms was taken into account by the use of a global wear coefficient obtained from experimental measurements. Such implementation considers an incremental computation for surface wear based on the nodal displacements by means of adaptive mesh tools that rearrange local nodal positions. In this way, the worn track was obtained and new surface profile is integrated for mass loss assessments. This work also presents experimental pin on disc tests with AISI 4140 pins on rotating AISI H13 discs with normal loads of 10, 35, 70 and 140 N, which represent, respectively, mild, transition and severe wear regimes, at sliding speed of 0.1 m/s. Numerical and experimental results were compared in terms of wear rate and friction coefficient. Furthermore, in the numerical simulation the stress field distribution and changes in the surface profile across the worn track of the disc were analyzed. The applied numerical formulation has shown to be more appropriate to predict mild wear regime than severe regime, especially due to the shorter running-in period observed in lower loads that characterizes this kind of regime.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this talk, we present a coupled system of integral equations for the πN → πN (s-channel) and ππ → N̅N (t-channel) lowest partial waves, derived from Roy–Steiner equations for pion–nucleon scattering. After giving a brief overview of this system of equations, we present the solution of the t-channel sub-problem by means of Muskhelishvili–Omnès techniques, and solve the s-channel sub-problem after finding a set of phase shifts and subthreshold parameters which satisfy the Roy–Steiner equations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vorbesitzer: Carl Wilhelm von Rothschild

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vorbesitzer: Synagoge des jüdischen Spitals

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vorbesitzer: Abraham Merzbacher

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Regulation of auxin distribution by PIN transporters is key in the dynamic modulation of root growth and branching. Three novel papers shed light on an intricate network through which several hormones and transcriptional regulators collectively fine-tune the transcriptional level of these auxin transporters in the root.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To compare biomechanical stiffness of cadaveric canine cervical spine constructs stabilized with bicortical stainless steel pins and polymethylmethacrylate (PMMA), monocortical stainless steel screws with PMMA, or monocortical titanium screws with PMMA. STUDY DESIGN Biomechanical cadaver study. ANIMALS Eighteen canine cervical vertebral columns (C2-C7) were collected from skeletally mature dogs (weighing 22-32 kg). METHODS Specimens were radiographed and examined by dual energy X-ray absorptiometry. Stiffness of the unaltered C4-C5 intervertebral motion unit was measured in extension, flexion and lateral bending using non-destructive 4-point bend testing. Specimens were then stabilized by (1) bicortical stainless steel pins/PMMA, (2) monocortical stainless steel screws/PMMA, or (3) monocortical titanium screws/PMMA. Mechanical testing was repeated and stiffness data from unaltered specimens and the 3 treatment groups were compared. RESULTS All 3 surgical methods significantly increased stiffness of the C4-C5 motion unit compared with the unaltered specimen (P < .001 for all treatments), but stiffness was not significantly different among the 3 fixation groups (P = .578). CONCLUSIONS In this model, monocortical screw fixation (with stainless steel or titanium screws) was biomechanically equivalent to bicortical fixation.