900 resultados para performance testing


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: This paper seeks to measure in a quantitative way the degree of alignment among a set of performance measures between two organizations. Design/methodology/approach: This paper extends Venkatraman's test of coalignment to assess the alignment of a set of performance measures governing a contractual inter-organizational relationship. The authors applied the test and present coefficients of misalignment across three sets of measures: those used by a service provider involved in the research, those used by customers contracting the services, and those documented in 11 contracts studied. Findings: Results confirmed a high degree of alignment between target and actual operational performance in the contracts. The alignment of customers' financial objectives and contracts' operational metrics was low. Calculations show poor alignment between the objectives of the provider and the contribution received from the contracts. Research limitations/implications: Some limitations of the conclusions include the small sample of contracts used in the calculations. Further research should include not only actual contracts, but also failed ones. Practical implications: It is possible that misaligned goals, represented in misaligned performance measures, lead to tensions in intra-firm relationships. If these tensions are not addressed properly the relationship could be unstable or terminated prematurely. This method of measuring alignment could detect early potential dangers in intra-firm relationships. Originality/value: This paper extends Venkatraman's test of coalignment to assess the alignment of a set of performance measures governing a contractual inter-organizational relationship. Management researchers and business professionals may use this methodology when exploring degrees of alignment of performance measures in intra-functional and inter-firm relationships. © Emerald Group Publishing Limited.

Relevância:

40.00% 40.00%

Publicador:

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study presents the performance analysis and testing of a 250 kW medium-speed brushless doubly-fed induction generator (DFIG), and its associated power electronics and control systems. The experimental tests confirm the design, and showthe system's steady-state and dynamic performance and grid low-voltage ride- through capability. The medium-speed brushless DFIG in combination with a simplified two-stage gearbox promises a low-cost low-maintenance and reliable drivetrain for wind turbine applications. © The Institution of Engineering and Technology 2013.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background and purpose Efforts to prevent infection of arthroplasties, including the use of antibiotic-loaded bone cement, are not always successful. We investigated whether the incorporation of chitosan in gentamicin-loaded bone cement increases antibiotic release, and prevents bacterial adherence and biofilm formation by clinical isolates of Staphylococcus spp. In addition, we performed mechanical and degradation tests.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Implementation of both design for durability and performance-based standards and specifications are limited by the lack of rapid, simple, science-based test methods for characterizing the transport properties and deterioration resistance of concrete. To this end, this paper presents the background rationale and current developments in the application of electrical property measurements - conductivity in this instance - as a testing methodology to evaluate the relative performance of a range of concrete mixes. The technique can not only be used on standard specimens (e.g. cubes), but also lends itself to in-situ monitoring thereby allowing measurements to be obtained on the as-placed concrete. It is the latter which forms the focus of the current work. Conductivity measurements are presented for concretes with and without supplementary cementitious materials (SCM's) from demoulding up to 400-days. It is shown that electrical conductivity measurements display a continual decrease over the entire test period and attributed to the pore structure refinement due to hydration and pozzolanic reaction in those concretes containing blast furnace slag or fly ash. The term Formation Factor is introduced to rank concrete performance in terms of is resistance to chloride penetration.