942 resultados para oscillatory breathing
Resumo:
Subjects with chronic obstructive pulmonary disease (COPD) present breathing pattern and thoracoabdominal motion abnormalities that may contribute to exercise limitation. Twenty-two men with stable COPD (FEV1 = 42.6 ± 13.5% predicted; age 68 ± 8 years; mean ± SD) on usual medication and with at least 5 years of diagnosis were evaluated at rest and during an incremental cycle exercise test (10 watts/2 min). Changes in respiratory frequency, tidal volume, rib cage and abdominal motion contribution to tidal volume and the phase angle that measures the asynchrony were analyzed by inductive respiratory plethysmography at rest and during three levels of exercise (30-50, 70-80, and 100% maximal work load). Repeated measures ANOVA followed by pre-planned contrasts and Bonferroni corrections were used for analyses. As expected, the greater the exercise intensity the higher the tidal volume and respiratory frequency. Abdominal motion contributed to the tidal volume increase (rest: 49.82 ± 11.19% vs exercise: 64.15 ± 9.7%, 63.41 ± 10%, and 65.56 ± 10.2%, respectively, P < 0.001) as well as the asynchrony [phase angle: 11.95 ± 7.24° at rest vs 22.2 ± 15° (P = 0.002), 22.6 ± 9° (P < 0.001), and 22.7 ± 8° (P < 0.001), respectively, at the three levels of exercise]. In conclusion, the increase in ventilation during exercise in COPD patients was associated with the major motion of the abdominal compartment and with an increase in the asynchrony independent of exercise intensity. It suggests that cycling exercise is an effective way of enhancing ventilation in COPD patients.
Resumo:
Oscillatory contractile activity is an inherent property of blood vessels. Various cellular mechanisms have been proposed to contribute to oscillatory activity. Mouse small mesenteric arteries display a unique low frequency contractile oscillatory activity (1 cycle every 10-12 min) upon phenylephrine stimulation. Our objective was to identify mechanisms involved in this peculiar oscillatory activity. First-order mesenteric arteries were mounted in tissue baths for isometric force measurement. The oscillatory activity was observed only in vessels with endothelium, but it was not blocked by L-NAME (100 µM) or indomethacin (10 µM), ruling out the participation of nitric oxide and prostacyclin, respectively, in this phenomenon. Oscillatory activity was not observed in vessels contracted with K+ (90 mM) or after stimulation with phenylephrine plus 10 mM K+. Ouabain (1 to 10 µM, an Na+/K+-ATPase inhibitor), but not K+ channel antagonists [tetraethylammonium (100 µM, a nonselective K+ channel blocker), Tram-34 (10 µM, blocker of intermediate conductance K+ channels) or UCL-1684 (0.1 µM, a small conductance K+ channel blocker)], inhibited the oscillatory activity. The contractile activity was also abolished when experiments were performed at 20°C or in K+-free medium. Taken together, these results demonstrate that Na+/K+-ATPase is a potential source of these oscillations. The presence of α-1 and α-2 Na+/K+-ATPase isoforms was confirmed in murine mesenteric arteries by Western blot. Chronic infusion of mice with ouabain did not abolish oscillatory contraction, but up-regulated vascular Na+/K+-ATPase expression and increased blood pressure. Together, these observations suggest that the Na+/K+ pump plays a major role in the oscillatory activity of murine small mesenteric arteries.
Resumo:
Lung hyperinflation up to vital capacity is used to re-expand collapsed lung areas and to improve gas exchange during general anesthesia. However, it may induce inflammation in normal lungs. The objective of this study was to evaluate the effects of a lung hyperinflation maneuver (LHM) on plasma cytokine release in 10 healthy subjects (age: 26.1 ± 1.2 years, BMI: 23.8 ± 3.6 kg/m²). LHM was performed applying continuous positive airway pressure (CPAP) with a face mask, increased by 3-cmH2O steps up to 20 cmH2O every 5 breaths. At CPAP 20 cmH2O, an inspiratory pressure of 20 cmH2O above CPAP was applied, reaching an airway pressure of 40 cmH2O for 10 breaths. CPAP was then decreased stepwise. Blood samples were collected before and 2 and 12 h after LHM. TNF-α, IL-1β, IL-6, IL-8, IL-10, and IL-12 were measured by flow cytometry. Lung hyperinflation significantly increased (P < 0.05) all measured cytokines (TNF-α: 1.2 ± 3.8 vs 6.4 ± 8.6 pg/mL; IL-1β: 4.9 ± 15.6 vs 22.4 ± 28.4 pg/mL; IL-6: 1.4 ± 3.3 vs 6.5 ± 5.6 pg/mL; IL-8: 13.2 ± 8.8 vs 33.4 ± 26.4 pg/mL; IL-10: 3.3 ± 3.3 vs 7.7 ± 6.5 pg/mL, and IL-12: 3.1 ± 7.9 vs 9 ± 11.4 pg/mL), which returned to basal levels 12 h later. A significant correlation was found between changes in pro- (IL-6) and anti-inflammatory (IL-10) cytokines (r = 0.89, P = 0.004). LHM-induced lung stretching was associated with an early inflammatory response in healthy spontaneously breathing subjects.
Resumo:
The application of continuous positive airway pressure (CPAP) produces important hemodynamic alterations, which can influence breathing pattern (BP) and heart rate variability (HRV). The aim of this study was to evaluate the effects of different levels of CPAP on postoperative BP and HRV after coronary artery bypass grafting (CABG) surgery and the impact of CABG surgery on these variables. Eighteen patients undergoing CABG were evaluated postoperatively during spontaneous breathing (SB) and application of four levels of CPAP applied in random order: sham (3 cmH2O), 5 cmH2O, 8 cmH2O, and 12 cmH2O. HRV was analyzed in time and frequency domains and by nonlinear methods and BP was analyzed in different variables (breathing frequency, inspiratory tidal volume, inspiratory and expiratory time, total breath time, fractional inspiratory time, percent rib cage inspiratory contribution to tidal volume, phase relation during inspiration, phase relation during expiration). There was significant postoperative impairment in HRV and BP after CABG surgery compared to the preoperative period and improvement of DFAα1, DFAα2 and SD2 indexes, and ventilatory variables during postoperative CPAP application, with a greater effect when 8 and 12 cmH2O were applied. A positive correlation (P < 0.05 and r = 0.64; Spearman) was found between DFAα1 and inspiratory time to the delta of 12 cmH2O and SB of HRV and respiratory values. Acute application of CPAP was able to alter cardiac autonomic nervous system control and BP of patients undergoing CABG surgery and 8 and 12 cmH2O of CPAP provided the best performance of pulmonary and cardiac autonomic functions.
Resumo:
This study used three Oculomotor Delayed Response (ODR) tasks to investigate the unique cognitive demands during the delay period. Changes in alpha power were used to index cognitive efforts during the delay period. Continuous EEGs from 25 healthy young adults (18-34 years) were recorded using dense electrode array. The data was analyzed by 6-cycle Morlet wavelet decompositions in the frequency range of 2-30 Hz to create time- frequency decompositions for four midline electrode sites. The 99% confidence intervals using the bootstrapped 20% trimmed mean of the 10 Hz frequency were used to examine the differences among conditions. Compared to two Memory conditions (Match and Non-Match), Control condition yielded significant differences in all frequencies over the entire trial period, suggesting a cognitive state difference. Compared to Match condition, the Non–Match condition had lower alpha activity during the delay period at each midline electrode site reflecting the higher cognitive effort required.
Resumo:
Introduction: Les troubles respiratoires du sommeil (TRS), qui représentent une préoccupation croissante pour la santé, ont des effets significatifs sur la santé, le comportement et la performance académique chez l’enfant. Les malformations craniofaciales, l’hypertrophie adéno-amygdalienne et l'obésité, représentent des facteurs de risque importants dans le développement de cette condition. Les symptômes des TRS ont été étudiés dans une étude prospective chez les enfants et adolescents durant leur traitement orthodontique dans un milieu universitaire. Cette étude a cherché à décrire la prévalence et les facteurs de risque principaux des TRS, ainsi que l'impact des différentes interventions orthodontiques sur les symptômes TRS. Matériel et méthodes: dans une étude cohorte prospective, un groupe de 168 sujets âgés de 12 à 21 ans ont été soumis, quatre ans après la prise de données initiale, à un examen craniofacial en plus d'être administré des questionnaires qui ont recueilli des données sur la situation socio-démographique, le bruxisme et les troubles d’ATM, le sommeil et le comportement diurne, et les facteurs neuropsychologiques. Résultats: l'indice de masse corporelle a été augmenté mais est demeurée dans la même catégorie aux deux moments de l'enquête. Il ya eu une augmentation du serrement des dents et des symptômes de l'ATM, une diminution de la taille des amygdales, et une augmentation de la somnolence diurne. La prévalence des TRS n'a pas changé entre l’étude initiale et l’étude de suivi. Aucune intervention orthodontique s'est avérée avoir un effet cliniquement significatif sur les voies aériennes supérieures. Conclusions: la prévalence des symptômes TRS était constante par rapport aux valeurs de base pour la population étudiée, mais a augmenté si rapportée à la population générale. Les traitements orthodontiques ne montrent aucun effet sur les TRS. Mots-clés : apnée du sommeil, craniofacial, prévalence, ronflement, traitement orthodontique, voies aériennes supérieures
Resumo:
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal
Resumo:
Introduction: L’expansion palatine du maxillaire a beaucoup d’effets positifs sur la respiration et la qualité du sommeil, mais peu d'études ont examiné ces données sur des adultes ayant dépassé l’âge permettant de bénéficier d'une expansion palatine conventionnelle. Le but de cette recherche est d’évaluer la stabilité de l’EPRAC (expansion palatine rapide assistée chirurgicalement) et son effet sur les troubles respiratoires après l’ablation des appareils orthodontiques. Méthodes: Neuf patients (Âge moyen 21, entre 16-39 ans) nécessitant une EPRAC ont passé des nuits dans un laboratoire de sommeil, et ce avant l’EPRAC, après l’EPRAC, et après l’ablation des appareils fixes. Les radiographies céphalométriques postéroantérieures ainsi que les modèles d’étude ont été pris pendant ces trois périodes de temps. Résultats: L’analyse des modèles d’étude a démontré une récidive significative au niveau des distances inter-molaires et inter-canines au niveau du maxillaire seulement. Les analyses céphalométriques ont démontré une récidive au niveau de la largeur maxillaire. Aucun changement important n'a été observé dans les stades de sommeil, mais une réduction importante dans l’index de ronflement a été notée. De plus, il y avait moins de changements entre les stades de sommeil. Conclusions: La récidive squelettique est minime et cliniquement non significative. Par contre, les changements dans les distances intermolaires et intercanines sont cliniquement importants. Il semble également qu'une EPRAC ait un effet positif sur la qualité de sommeil par la réduction de l’indice de ronflement ainsi que sur la diminution des changements entre les stades de sommeil.
Resumo:
El sistema respiratorio, es uno de los principales sistemas de soporte vital del cuerpo. Aquí se explican los pulmones, cómo funcionan, y problemas respiratorios. Se ha mantenido el detalle anatómico, pero también incluye un primer plano desde el punto de vista médico con fotografías en color. Se hace énfasis en la educación para la salud y la importancia de cuidar nuestro cuerpo.
Resumo:
Los pequeños pueden aprender las complejidades del sistema respiratorio no sólo de una manera informativa, sino también con experimentos sencillos, que muestran cómo es y cómo funciona realmente. Para averiguar la razón del estornudo, la tos y el hipo, las alergias y el cáncer de pulmón.
Resumo:
We consider the approximation of some highly oscillatory weakly singular surface integrals, arising from boundary integral methods with smooth global basis functions for solving problems of high frequency acoustic scattering by three-dimensional convex obstacles, described globally in spherical coordinates. As the frequency of the incident wave increases, the performance of standard quadrature schemes deteriorates. Naive application of asymptotic schemes also fails due to the weak singularity. We propose here a new scheme based on a combination of an asymptotic approach and exact treatment of singularities in an appropriate coordinate system. For the case of a spherical scatterer we demonstrate via error analysis and numerical results that, provided the observation point is sufficiently far from the shadow boundary, a high level of accuracy can be achieved with a minimal computational cost.
Resumo:
The design of high-voltage equipment encompasses the study of oscillatory surges caused by transients such as those produced by switching. By obtaining a model, the response of which reconstructs that observed in the actual system, simulation studies and critical tests can be carried out on the model rather than on the equipment itself. In this paper, methods for the construction of simplified models are described and it is shown how the use of a complex model does not necessarily result in superior response pattern reconstruction.
Resumo:
Transport and deposition of charged inhaled aerosols in double planar bifurcation representing generation three to five of human respiratory system has been studied under a light activity breathing condition. Both steady and oscillatory laminar inhalation airflow is considered. Particle trajectories are calculated using a Lagrangian reference frame, which is dominated by the fluid force driven by airflow, gravity force and electrostatic forces (both of space and image charge forces). The particle-mesh method is selected to calculate the space charge force. This numerical study investigates the deposition efficiency in the three-dimensional model under various particle sizes, charge values, and inlet particle distribution. Numerical results indicate that particles carrying an adequate level of charge can improve deposition efficiency in the airway model.