668 resultados para obturator prostheses
Resumo:
The objective of this systematic review was to assess the 5- and 10-year survival of implant-supported fixed dental prostheses (FDPs) and to describe the incidence of biological and technical complications.
Resumo:
BACKGROUND: The Swiss Federal Office of Public Health demanded a nationwide HTA-registry for cervical total disc arthroplasty (TDA), to decide about its reimbursement. The goal of the SWISSspine registry is to generate evidence about the safety and efficiency of cervical TDA. MATERIALS AND METHODS: Three hundred thirty-two cases treated between 3.2005 and 6.2006 who were eligible for 5 years follow-ups were included in the study. Follow-up rates for 3-6 months, 1, 2 and 5 years were 84.6, 74.4, 50.6 and 64.8 %, respectively. Outcome measures were neck and arm pain, medication, quality of life, intraoperative and postoperative complication and revision rates. In addition, segmental mobility, ossification, adjacent and distant segment degeneration were analyzed at the 5-year follow-up. RESULTS: There was significant, clinically relevant and lasting reduction of neck (preop/postop 60/21 VAS points) and arm pain (preop/postop VAS 67/17) and a consequently decreased analgesics consumption and quality of life improvement (preop/postop 0.39/0.82 EQ-5D points) until the 5-year follow-up. The rates for intraoperative and early postoperative complications were 0.6 and 7.2 %, respectively. In 0.6 % an early and in 3.9 % a late revision surgery was performed. At the 5-year follow-up, the average range of motion of the mobile segments (88.2 %) was 10.2°. In 40.7 % of the patients osteophytes at least potentially affecting range of motion were seen. CONCLUSIONS: Cervical TDA appeared as safe and efficient in long-term pain alleviation, consequent reduction of pain killer consumption and in improvement of quality of life. The improvement is stable over the 5 years postoperative period. The vast majority of treated segments remained mobile after 5 years, although 40.7 % of patients showed osteophytes.
Resumo:
To evaluate the hard and the soft tissue parameters around implants supporting fixed prostheses over a period of 5 years and the possible association to the increase in periimplant bone density (IPBD).
Resumo:
By analogy with endocarditis prophylaxis, patients with joint prostheses are often given antibiotics before invasive procedures or dental treatment. However, this analogy is not justified: The pathogenesis and bacterial spectrum of infections of artificial joints differ from those of endocarditis. Since the efficacy of administering prophylactic antibiotics to patients with joint prostheses has never been scientifically proven, there is no general indication for such prophylaxis. On the other hand, infections in other parts of the body should be actively sought and treated promptly. Prophylactic antibiotic administration may be appropriate in individual cases during a procedure in patients who are at increased risk of a haematogenic prosthesis infection as a result of bacteraemia. For operations routinely performed under perioperative antibiotic cover, the same prophylaxis should also be used for patients with joint prostheses.
Resumo:
OBJECTIVE: A previous study of radiofrequency neurotomy of the articular branches of the obturator nerve for hip joint pain produced modest results. Based on an anatomical and radiological study, we sought to define a potentially more effective radiofrequency method. DESIGN: Ten cadavers were studied, four of them bilaterally. The obturator nerve and its articular branches were marked by wires. Their radiological relationship to the bone structures on fluoroscopy was imaged and analyzed. A magnetic resonance imaging (MRI) study was undertaken on 20 patients to determine the structures that would be encountered by the radiofrequency electrode during different possible percutaneous approaches. RESULTS: The articular branches of the obturator nerve vary in location over a wide area. The previously described method of denervating the hip joint did not take this variation into account. Moreover, it approached the nerves perpendicularly. Because optimal coagulation requires electrodes to lie parallel to the nerves, a perpendicular approach probably produced only a minimal lesion. In addition, MRI demonstrated that a perpendicular approach is likely to puncture femoral vessels. Vessel puncture can be avoided if an oblique pass is used. Such an approach minimizes the angle between the target nerves and the electrode, and increases the likelihood of the nerve being captured by the lesion made. Multiple lesions need to be made in order to accommodate the variability in location of the articular nerves. CONCLUSIONS: The method that we described has the potential to produce complete and reliable nerve coagulation. Moreover, it minimizes the risk of penetrating the great vessels. The efficacy of this approach should be tested in clinical trials.
Resumo:
PURPOSE: The purpose of this article is to assess the healing qualities of presealed knitted polyester prostheses. METHODS: Thoracic aortic replacement was performed with grafts with four different coating materials-collagen (CP), albumin (AP), and two with gelatin (GP1/GP2)-in four groups of 15 pigs each. Two weeks, 6 weeks, and 6 months after operation, five pigs of each group were killed. Healing quality was assessed by morphometric analysis of the remaining coating, the extent of tissue ingrowth, and the thickness of the inner layer. RESULTS: The sealant was rapidly absorbed in all prostheses except for the AP (remaining coating at 2 weeks: GP1 22.1%, GP2 34.7%, and CP 68.0% vs AP 97.1% [p < 0.05]), remaining coating at 6 weeks: GP1/GP2 0% and CP 2.5% vs AP 76.7% (p < .01). At 6 months, remaining coating was only detectable in AP (21.5%). At 2 weeks the extent of tissue ingrowth ranged from 65.7% in GP1 and 75.3% in CP to 80% in GP2 versus 8.9% in AP (p < 0.05). There was a slow increase of tissue ingrowth until the sixth postoperative week (GP1 74.4%, GP2 85.0%, and CP 91.3% versus AP 19.6% [p < 0.01]). Thickness of the internal layer varied from 0.11 to 0.21 mm at 2 weeks in all grafts studied and from 1.02 mm (AP) and 1.28 mm (GP2) to 1.39 mm (GP1), versus 0.41 mm in the CP (p < 0.01) after 6 months of implantation. CONCLUSIONS: The type of coating significantly influences the healing properties of knitted polyester prostheses. When used for thoracic aortic replacement in pigs, AP coating clearly results in inferior healing compared with GP1/GP2 or CP impregnation, with digestion of the coating material and tissue ingrowth used as parameters. The thinnest internal layer was found in the CP prostheses, reflecting superior healing properties of this coating in the model studied.
Resumo:
OBJECTIVE: The aim of this systematic review was to assess the survival rates of short-span implant-supported cantilever fixed dental prostheses (ICFDPs) and the incidence of technical and biological complications after an observation period of at least 5 years. MATERIAL AND METHODS: An electronic MEDLINE search supplemented by manual searching was conducted to identify prospective or retrospective cohort studies reporting data of at least 5 years on ICFDPs. Five- and 10-year estimates for failure and complication rates were calculated using standard or random-effect Poisson regression analysis. RESULTS: The five studies eligible for the meta-analysis yielded an estimated 5- and 10-year ICFDP cumulative survival rate of 94.3% [95 percent confidence interval (95% CI): 84.1-98%] and 88.9% (95% CI: 70.8-96.1%), respectively. Five-year estimates for peri-implantitis were 5.4% (95% CI: 2-14.2%) and 9.4% (95% CI: 3.3-25.4%) at implant and prosthesis levels, respectively. Veneer fracture (5-year estimate: 10.3%; 95% CI: 3.9-26.6%) and screw loosening (5-year estimate: 8.2%; 95% CI: 3.9-17%) represented the most common complications, followed by loss of retention (5-year estimate: 5.7%; 95% CI: 1.9-16.5%) and abutment/screw fracture (5-year estimate: 2.1%; 95% CI: 0.9-5.1%). Implant fracture was rare (5-year estimate: 1.3%; 95% CI: 0.2-8.3%); no framework fracture was reported. Radiographic bone level changes did not yield statistically significant differences either at the prosthesis or at the implant levels when comparing ICFDPs with short-span implant-supported end-abutment fixed dental prostheses. CONCLUSIONS: ICFDPs represent a valid treatment modality; no detrimental effects can be expected on bone levels due to the presence of a cantilever extension per se.
Resumo:
SWISSspine is a so-called pragmatic trial for assessment of safety and efficiency of total disc arthroplasty (TDA). It follows the new health technology assessment (HTA) principle of "coverage with evidence development". It is the first mandatory HTA registry of its kind in the history of Swiss orthopaedic surgery. Its goal is the generation of evidence for a decision by the Swiss federal office of health about reimbursement of the concerned technologies and treatments by the basic health insurance of Switzerland. During the time between March 2005 and 2008, 427 interventions with implantation of 497 lumbar total disc arthroplasties have been documented. Data was collected in a prospective, observational multicenter mode. The preliminary timeframe for the registry was 3 years and has already been extended. Data collection happens pre- and perioperatively, at the 3 months and 1-year follow-up and annually thereafter. Surgery, implant and follow-up case report forms are administered by spinal surgeons. Comorbidity questionnaires, NASS and EQ-5D forms are completed by the patients. Significant and clinically relevant reduction of low back pain VAS (70.3-29.4 points preop to 1-year postop, p < 0.0001) leg pain VAS (55.5-19.1 points preop to 1-year postop, p < 0.001), improvement of quality of life (EQ-5D, 0.32-0.73 points preop to 1-year postop, p < 0.001) and reduction of pain killer consumption was revealed at the 1-year follow-up. There were 14 (3.9%) complications and 7 (2.0%) revisions within the same hospitalization reported for monosegmental TDA; there were 6 (8.6%) complications and 8 (11.4%) revisions for bisegmental surgery. There were 35 patients (9.8%) with complications during followup in monosegmental and 9 (12.9%) in bisegmental surgery and 11 (3.1%) revisions with 1 [corrected] new hospitalization in monosegmental and 1 (1.4%) in bisegmental surgery. Regression analysis suggested a preoperative VAS "threshold value" of about 44 points for increased likelihood of a minimum clinically relevant back pain improvement. In a short-term perspective, lumbar TDA appears as a relatively safe and efficient procedure concerning pain reduction and improvement of quality of life. Nevertheless, no prediction about the long-term goals of TDA can be made yet. The SWISSspine registry proofs to be an excellent tool for collection of observational data in a nationwide framework whereby advantages and deficits of its design must be considered. It can act as a model for similar projects in other health-care domains.