931 resultados para newborn apnea
Resumo:
Objectives: To describe the use of antenatal corticosteroid and clinical evolution of preterm babies. Methods: An observational prospective cohort study was carried out. All 463 pregnant women and their 514 newborn babies with gestational age ranging from 23 to 34 weeks, born at the Brazilian Neonatal Research Network units, were evaluated from August 1 to December 31, 2001. The data were obtained through maternal interview, analysis of medical records, and follow-up of the newborn infants. Data analysis was performed with the use of chi-square, t Student, Mann-Whitney, and ANOVA tests and multiple logistic regression, with level of significance set at 5%. Results: Treatment was directly associated with the number of prenatal visits, with maternal hypertension and with the antenatal use of tocolytic agents. Babies from treated pregnant women presented better Apgar scores at the 1st and 5th minute, reduced need for intervention in the delivery room and lower SNAPPE II. They were born with higher birth weight, longer gestational age and needed less surfactant use, ventilation, and oxygenation time. After multiple logistic regression, the use of antenatal corticosteroid independently improved birth conditions, decreased ventilation time, being related to increased occurrence of neonatal sepsis. Conclusions: The use of corticosteroid was associated with better prenatal care and birth conditions, better preterm evolution but higher risk of infection. Copyright © 2004 by Sociedade Brasileira de Pediatria.
Resumo:
The modulatory effects of melatonin (MLT) on maternal and fetal macrophages in diabetic rats and the repercussion of maternal hyperglycemia on fetus-placenta parameters were studied. This was achieved by determining maternal and fetal blood glucose, weight and superoxide release by macrophages. Placental weight, protein, DNA and RNA concentration were also verified. Superoxide levels in macrophages isolated from pregnant healthy rats were higher than those obtained from diabetic animals. Melatonin increased significantly in the macrophages of control animals (18.7 ± 2.8 with MLT compared to 14.2 ± 1.6 without MLT) but decreased with melatonin stimulation in diabetic rats (8.8 ± 1.4 with MLT compared to 12.9 ± 2.1 without MLT). Melatonin significantly decreased superoxide levels in newborns of diabetic mothers (7.3 ± 3.4) compared to those of healthy (14.6 ± 3.5) mothers. Blood glucose levels were significantly higher (p<0.05) in newborn rats of diabetic mothers (108.3 ± 7.8) compared to blood glucose levels in newborn control rats (81.2 ± 10.7). Body weight was significantly higher (p <0.05) in the offspring of rats with alloxan-induced diabetes. No statistical difference (p> 0.05) was observed in the placenta weight, total protein concentration and DNA of rats. The RNA concentration was significantly lower (p <0.05) in the placentas of rats with alloxan-induced diabetes (156.1 ± 71.8), when compared to the concentration of RNA in the placentas of control rats (239.5 ± 77.3). In conclusion, maternal hyperglycemia modified the fetus-placental parameters and melatonin modulated the macrophages activation in maternal and fetal diabetic rats.
Resumo:
Congenital epulis (CE) of the newborn is a rare benign soft tissue tumor that presents at birth. It occurs usually as a single mass with various sizes, although some multiple lesions have also been reported. The lesion is more common in female neonates and normally affects the maxillary alveolar ridge. Rare recurrence and no malignant alteration have also been reported. This condition may interfere with respiration, feeding or adequate closure of the mouth. A decisive diagnosis is made by histopathologic analysis as other newborn lesions can be incorrectly diagnosed as CE. This article presents a case report of a female infant who presented a fibrotic mass in the primary lateral incisor and canine region of the maxillary alveolar ridge. The lesion was not causing feeding or respiratory problems. After a watchful waiting procedure and no spontaneous regression, the lesion was excised under local anesthesia and confirmed by histopathologic analysis as CE.
Resumo:
Preeclampsia (PE) is the most common medical complication in pregnancy and a major cause of maternal and fetal morbidity and mortality. This disease is a great challenge for obstetricians because there are no effective interventions to treat or prevent it, and antenatal care involves a difficult balance between the risks for women to continue pregnancy and the risks for the baby's early birth. Fetal complications in PE are directly related to gestational age and the severity of maternal disease and include increased rates of preterm delivery, intrauterine growth restriction, placental abruption, and perinatal death. The major complications for the newborn are related to prematurity, although the data on the morbidity and outcome for preterm infants of women who have PE are conflicting, and few studies address this issue. The pathogenesis of PE involves abnormal placentation associated with immune and vascular events that result in endothelial dysfunction and clinical manifestations of PE. This disease has been associated with imbalance in angiogenic factors and oxidative stress. Nevertheless, only a limited number of studies have been carried out on fetuses and newborns that suggest that infants born from women who have PE are exposed to increased oxidative stress. Because oxidative stress and free radicals may play roles in several neonatal diseases, a direct effect of maternal disease on neonatal outcome is expected, and further research on such neonates, in the short- and long-term, is urgently needed. © 2011 by the American Academy of Pediatrics.
Resumo:
Objective: Sleep spindles have been suggested as surrogates of thalamo-cortical activity. Internal frequency modulation within a spindle's time frame has been demonstrated in healthy subjects, showing that spindles tend to decelerate their frequency before termination. We investigated internal frequency modulation of slow and fast spindles according to Obstructive Sleep Apnea (OSA) severity and brain topography. Methods: Seven non-OSA subjects and 21 patients with OSA contributed with 30 min of Non-REM sleep stage 2, subjected to a Matching pursuit procedure with Gabor chirplet functions for automatic detection of sleep spindles and quantification of sleep spindle internal frequency modulation (chirp rate). Results: Moderate OSA patients showed an inferior percentage of slow spindles with deceleration when compared to Mild and Non-OSA groups in frontal and parietal regions. In parietal regions, the percentage of slow spindles with deceleration was negatively correlated with global apnea-hypopnea index (r s = -0.519, p = 0.005). Discussion: Loss of physiological sleep spindle deceleration may either represent a disruption of thalamo-cortical loops generating spindle oscillations or some compensatory mechanism, an interesting venue for future research in the context of cognitive dysfunction in OSA. Significance: Quantification of internal frequency modulation (chirp rate) is proposed as a promising approach to advance description of sleep spindle dynamics in brain pathology. © 2013 International Federation of Clinical Neurophysiology.
Resumo:
OBJECTIVE: To verify if the reference values of Sleep Apnea cephalometric analysis of North American individuals are similar to the ones of Brazilian individuals presenting no craniofacial anomalies. The study also aimed to identify craniofacial alterations in Obstructive Sleep Apnea-Hypopnea Syndrome (OSAHS) patients in relation to individuals without clinical characteristics of the disease through this cephalometric analysis. METHOD: It were used 55 lateral cephalograms consisting of 29 for the control group of adult individuals without clinical characteristics of OSAHS and 26 apneic adults. All radiographs were submitted to Sleep Apnea cephalometric analysis through Radiocef Studio 2.0. The standard values of this analysis were compared, by means of z test, to the ones obtained from the control group and these were compared to values from apneic group through Student's t test. RESULTS: There were no significant differences between values obtained from control group and standard values. On the group of OSAHS patients it was observed a decrease on the dimensions of upper airways and an increase on the soft palate length. CONCLUSIONS: The standard values of Sleep Apnea analysis can be used as reference in Brazilian individuals. Besides, through lateral cephalograms it was possible to identify craniofacial alterations in OSAHS patients.
Resumo:
Purpose: The aim of this study was to validate the use of a mandibular repositioner appliance (MRA) to treat obstructive sleep apnea (OSA) and primary snoring, comparing polysomnographic and Epworth Sleepiness Scale (ESS) data obtained prior to and during MRA treatment. Materials and Methods: Sixty-three patients who presented with different degrees of OSA severity or primary snoring were fitted to a PM positioner between 2009 and 2011. The diagnosis was established by a polysomnogram (PSG) prior to treatment and after 6 months to verify the efficacy of MRA therapy. Subjective daytime sleepiness was evaluated by ESS questionnaire prior to treatment and at the follow-up. Results: Patients were divided into primary snoring and OSA groups. For the primary snoring group, PSG variables did not show significant results, except for a decrease in snoring. For the OSA group, the mean apnea-hypopnea index (AHI) was reduced from 23.0 +/- 11 to 5.3 +/- 4.0 and median ESS reduced significantly from 13.0 to 8.5. Complete response (AHI < 5) was found in 25 (40%) patients and partial response (AHI <= 10) in 27 (43%) patients. Conclusion: The findings validate the efficacy of the adjustable PM positioner for the safe treatment of OSA.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: This study was designed to evaluate the correlation between computed tomography findings and data from the physical examination and the Friedman Staging System (FSS) in patients with obstructive sleep apnea (OSA). Patients and Methods: We performed a retrospective evaluation by reviewing the medical records of 33 patients (19 male and 14 female patients) with a mean body mass index of 30.38 kg/m 2 and mean age of 49.35 years. Among these patients, 14 presented with severe OSA, 7 had moderate OSA, 7 had mild OSA, and 5 were healthy. Results: The patients were divided into 2 groups according to the FSS: Group A comprised patients with FSS stage I or II, and group B comprised patients with FSS stage III. By use of the Fisher exact test, a positive relationship between the FSS stage and apnea-hypopnea index ( P = .011) and between the FSS stage and body mass index ( P = .012) was found. There was no correlation between age ( P = .55) and gender ( P = .53) with the FSS stage. The analysis of variance test comparing the upper airway volume between the 2 groups showed P =.018. Conclusions: In this sample the FSS and upper airway volume showed an inverse correlation and were useful in analyzing the mechanisms of airway collapse in patients with OSA.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Serous Background: There are few studies assessing the clinical manifestations of sleep breathing disorders and polysomnograms in several pediatric age ranges. This studied aimed to assess polysomnography results such as apnea-hypopnea index, mean oxygen saturation and sleep efficiency in children presenting with airway obstruction and adenotonsillar hypertrophy complaints, and to establish whether they are correlated to age and sex. Methods: A retrospective study with children of both sexes, aged between 2 and 12 years, with clinically suspected obstructive sleep apnea syndrome and adenotonsillar hypertrophy, who underwent polysomnography before surgery. The children were allocated to groups according to their age range (Group I: 2 to 4 years old; Group II: 5 to 8 years old; Group III: 9 to 12 years old). Apnea-hypopnea index, mean oxygen saturation and sleep efficiency data were compared between sexes and among the three groups (Student’s t test, p < 0.05). Results: Of 167 children studied by polysomnography, 76.6% were of school age and 67% were male. For all studied age ranges, there was no difference between sexes for the investigated parameters (body mass index, apnea-hypopnea index, mean oxygen saturation and sleep efficiency). As regards mean oxygen saturation, Group I showed the lowest value (89.9 ± 6.2). Apnea-hypopnea indexes were higher in male children aged between 2 and 4 years (9.9 ± 5.2). Group III had the lowest sleep efficiency (84.1 ± 9.2). Conclusion: There was a predilection of more severe cases of obstructive sleep apnea syndrome for children younger than four years, shown by higher apnea-hypopnea index per hour and lower mean oxygen saturation in this age range.
Resumo:
Background Obstructive sleep apnea (OSA) is common among patients with coronary artery disease. However, OSA remains largely under recognized. The lack of clinical suspicion and difficulties to access full polysomnography (PSG) are limiting factors. The aim of this study was to evaluate, among patients referred to coronary artery bypass grafting (CABG): (i) the prevalence of OSA, (ii) the association of OSA with clinical symptoms, (iii) the performance of overnight unattended portable monitoring (PM) as an alternative method for the diagnosis of OSA. Methods Consecutive patients referred for CABG were evaluated by standard physical evaluation and validated questionnaires (Berlin questionnaire and Epworth Sleepiness Scale) and underwent full PSG and PM (Stardust II). Results We studied 70 consecutive patients (76% men), age 58 +/- 7 years (mean +/- SD), BMI [median (interquartile range)] 27.6 kg/m(2) (25.8-31.1). The prevalence of OSA (full PSG) using an apnea-hypopnea index of at least 5 events/h was 87%. Commonly used clinical traits for the screening of OSA such as the Epworth Sleepiness Scale and neck circumference had low sensitivities to detect OSA. In contrast, the Berlin questionnaire showed a good sensitivity (72%) to detect OSA. PM showed good sensitivity (92%) and specificity (67%) for the diagnosis of OSA. Conclusion OSA is strikingly common among patients referred for CABG. The Berlin questionnaire, but not symptom of excessive daytime sleepiness is a useful tool to screen OSA. PM is useful for the diagnosis of OSA and therefore is an attractive tool for widespread use among patients with coronary artery disease. Coron Artery Dis 23:31-38 (C) 2011 Wolters Kluwer Health | Lippincott Williams & Wilkins.