920 resultados para measurement techniques of Aerosoles
Resumo:
"Issued November 1943."
Resumo:
Mode of access: Internet.
Resumo:
Thesis (D.M.A.)--University of Washington, 2016-06
Resumo:
This research extends the consumer-based brand equity measurement approach to the measurement of the equity associated with retailers. This paper also addresses some of the limitations associated with current retailer equity measurement such as a lack of clarity regarding its nature and dimensionality. We conceptualise retailer equity as a four-dimensional construct comprising retailer awareness, retailer associations, perceived retailer quality, and retailer loyalty. The paper reports the result of an empirical study of a convenience sample of 601 shopping mall consumers at an Australian state capital city. Following a confirmatory factor analysis using structural equation modelling to examine the dimensionality of the retailer equity construct, the proposed model is tested for two retailer categories: department stores and speciality stores. Results confirm the hypothesised four-dimensional structure.
Resumo:
Background: The effective evaluation of physical activity interventions for older adults requires measurement instruments with acceptable psychometric properties that are sufficiently sensitive to detect changes in this population. Aim: To assess the measurement properties (reliability and validity) of the Community Healthy Activities Model Program for Seniors (CHAMPS) questionnaire in a sample of older Australians. Methods: CHAMPS data were collected from 167 older adults (mean age 79.1 S.D. 6.3 years) and validated with tests of physical ability and the SF-12 measures of physical and mental health. Responses from a sub-sample of 43 older adults were used to assess 1-week test-retest reliability. Results: Approximately 25% of participants needed assistance to complete the CHAMPS questionnaire. There were low but significant correlations between the CHAMPS scores and the physical performance measures (rho=0.14-0.32) and the physical health scale of the SF-12 (rho=0.12-0.24). Reliability coefficients were highest for moderate-intensity (ICC=0.81-0.88) and lowest for vigorous-intensity physical activity (ICC=0.34-0.45). Agreement between test-retest estimates of sufficient physical activity for health benefits (>= 150 min and >= 5 sessions per week) was high (percent agreement = 88% and Cohen's kappa = 0.68). Conclusion: These findings suggest that the CHAMPS questionnaire has acceptable measurement properties, and is therefore suitable for use among older Australian adults, as long as adequate assistance is provided during administration. (c) 2006 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Resumo:
The in situ real time measurement of the regression rate of a melting interface (RRMI) is performed by the ultrasonic measurement system reported here. The RRMI is the rate at which a solid/liquid interface (SLI) moves along a metallic rod while burning in an oxygen-enriched atmosphere and is an important flatnmability indicator. The ultrasonic transducer and associated equipment used to drive the transducer and record the echo signal is described, along with the process that transforms the acquired signals into a RRMI value. Test rods of various metals and geometric shapes were burned at several test conditions in different test facilities. The RRMI results with quantified errors are presented and reviewed. The effect of reduced gravity on burning metals is important to space-applications and RRMI results obtained in a reduced gravity environment are also presented.
Resumo:
Menorrhagia, or heavy menstrual bleeding (HMB), is a common gynaecological condition. As the aim of treatment is to improve women's wellbeing and quality of life (QoL), it is necessary to have effective ways to measure this. This study investigated the reliability and validity of the menorrhagia multi-attribute scale (MMAS), a menorrhagia-specific QoL instrument. Participants (n = 431) completed the MMAS and a battery of other tests as part of the baseline assessment of the ECLIPSE (Effectiveness and Cost-effectiveness of Levonorgestrel-containing Intrauterine system in Primary care against Standard trEatment for menorrhagia) trial. Analyses of their responses suggest that the MMAS has good measurement properties and is therefore an appropriate condition-specific instrument to measure the outcome of treatment for HMB. © 2011 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2011 RCOG.
Resumo:
Background/aim: The technique of photoretinoscopy is unique in being able to measure the dynamics of the oculomotor system (ocular accommodation, vergence, and pupil size) remotely (working distance typically 1 metre) and objectively in both eyes simultaneously. The aim af this study was to evaluate clinically the measurement of refractive error by a recent commercial photoretinoscopic device, the PowerRefractor (PlusOptiX, Germany). Method: The validity and repeatability of the PowerRefractor was compared to: subjective (non-cycloplegic) refraction on 100 adult subjects (mean age 23.8 (SD 5.7) years) and objective autarefractian (Shin-Nippon SRW-5000, Japan) on 150 subjects (20.1 (4.2) years). Repeatability was assessed by examining the differences between autorefractor readings taken from each eye and by re-measuring the objective prescription of 100 eyes at a subsequent session. Results: On average the PowerRefractor prescription was not significantly different from the subjective refraction, although quite variable (difference -0.05 (0.63) D, p = 0.41) and more negative than the SRW-5000 prescription (by -0.20 (0.72) D, p<0.001). There was no significant bias in the accuracy of the instrument with regard to the type or magnitude of refractive error. The PowerRefractor was found to be repeatable over the prescription range of -8.75D to +4.00D (mean spherical equivalent) examined. Conclusion: The PowerRefractor is a useful objective screening instrument and because of its remote and rapid measurement of both eyes simultaneously is able to assess the oculomotor response in a variety of unrestricted viewing conditions and patient types.
Resumo:
High precision manufacturers continuously seek out disruptive technologies to improve the quality, cost, and delivery of their products. With the advancement of machine tool and measurement technology many companies are ready to capitalise on the opportunity of on-machine measurement (OMM). Coupled with business case, manufacturing engineers are now questioning whether OMM can soon eliminate the need for post-process inspection systems. Metrologists will however argue that the machining environment is too hostile and that there are numerous process variables which need consideration before traceable measurement on-the-machine can be achieved. In this paper we test the measurement capability of five new multi-axis machine tools enabled as OMM systems via on-machine probing. All systems are tested under various operating conditions in order to better understand the effects of potentially significant variables. This investigation has found that key process variables such as machine tool warm-up and tool-change cycles can have an effect on machine tool measurement repeatability. New data presented here is important to many manufacturers whom are considering utilising their high precision multi-axis machine tools for both the creation and verification of their products.
Resumo:
The advection of relatively fresh Java Sea water through the Sunda Strait is presently responsible for the low-salinity "tongue" in the eastern tropical Indian Ocean with salinities as low as 32 per mil. The evolution of the hydrologic conditions in the eastern tropical Indian Ocean since the last glacial period, when the Sunda shelf was exposed and any advection via the Sunda Strait was cutoff, and the degree to which these conditions were affected by the Sunda Strait opening are not known. Here we have analyzed two sediment cores (GeoB 10042-1 and GeoB 10043-3) collected from the eastern tropical Indian Ocean off the Sunda Strait that cover the past ~40,000?years. We investigate the magnitude of terrigenous supply, sea surface temperature (SST), and seawater d18O (d18Osw) changes related to the sea level-driven opening of the Sunda Strait. Our new spliced records off the Sunda Strait show that during the last glacial, average SST was cooler and d18Osw was higher than elsewhere in the eastern tropical Indian Ocean. Seawater d18O decreased ~0.5 per mil after the opening of the Sunda Strait at ~10 kyr B.P. accompanied by an SST increase of 1.7°C. We suggest that fresher sea surface conditions have persisted ever since due to a continuous transport of low-salinity Java Sea water into the eastern tropical Indian Ocean via the Sunda Strait that additionally increased marine productivity through the concomitant increase in terrigenous supply.