982 resultados para loin eye area
Resumo:
Pós-graduação em Zootecnia - FMVZ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A feedlot demonstration utilizing Encore®, a new longterm implant product, was completed at the Allee Demonstration Farm at Newell, Iowa in 1999. Seventyone steers (697 lbs.) were allotted by weight and hide color and assigned to one of three treatments: 1) Encore® (43.9 mg estradiol = E) on day 0; 2) Encore® plus Component® TS (140 mg trenbolone acetate = ETS0) on day 0; or 3) Encore® on day 0 followed by Component® TS (ETS100) on day 100. Due to wide standard deviation in the weight of steers at the beginning of the demonstration, cattle were harvested in two groups. Approximately half of each treatment group was sorted by visual appraisal as to market readiness. Statistical interactions existed within treatment group between first and second harvest dates, therefore data were split and analyzed accordingly. In the first harvest group, ETS0 steers had higher marbling scores than ETS100 steers, and lower average daily gain than E steers and ETS100 steers. In the second harvest group, ETS0 steers had more fat at the 12th/13 rib than ETS100 steers, but did not differ from E steers. Marbling scores were also higher for ETS0 steers than either ETS100 or E steers in the second harvest group. Pooled data reveal that ETS0 steers had higher marbling scores than ETS100 steers and tended to have higher marbling scores than E steers. First harvest E and ETS100 steers had greater average daily gain than ETS0 steers. In the second harvest group, ETS0 steers had heavier final ending weights than E steers but did not differ from ETS100 steers. Final ending weights, rib eye area, fat thickness at the 12th/13th rib, KPH fat, and calculated yield grades did not differ among treatment groups in the pooled data.
Resumo:
This study was conducted to assess the effect of air-dried Moringa stenopetala leaf (MSL) supplementation on carcass components and meat quality in Arsi-Bale goats. A total of 24 yearling goats with initial body weight of 13.6+/-0.25 kg were randomly divided into four treatments with six goats each. All goats received a basal diet of natural grass hay ad libitum and 340 g head^(−1) d^(−1) concentrate. The treatment diets contain a control diet without supplementation (T1) and diets supplemented with MSL at a rate of 120 g head^(−1) d^(−1) (T2), 170 g head^(−1) d^(−1) (T3) and 220 g head^(−1) d^(−1) (T4). The results indicated that the average slaughter weight of goats reared on T3 and T4 was 18.2 and 18.3 kg, respectively, being (P<0.05) higher than those of T1 (15.8 kg) and T2 (16.5 kg). Goats fed on T3 and T4 diets had higher (P<0.05) daily weight gain compared with those of T1 and T2. The hot carcass weight in goats reared on T3 and T4 diets was 6.40 and 7.30 kg, respectively, being (P<0.05) higher than those of T1 (4.81 kg) and T2 (5.06 kg). Goats reared on T4 had higher (P<0.05) dressing percentage than those reared in other treatment diets. The rib-eye area in goats reared on T2, T3 and T4 diets was higher (P<0.05) than those of T1. The protein content of the meat in goats reared on T3 and T4 was 24.0 and 26.4%, respectively being significantly higher than those of T1 (19.1%) and T2 (20.1%). In conclusion, the supplementation of MSL to natural grass hay improved the weight gain and carcass parts of Arsi-Bale goats indicating Moringa leaves as alternative protein supplements to poor quality forages.
Resumo:
Correlation between genetic parameters and factors such as backfat thickness (BFT), rib eye area (REA), and body weight (BW) were estimated for Canchim beef cattle raised in natural pastures of Brazil. Data from 1648 animals were analyzed using multi-trait (BFT, REA, and BW) animal models by the Bayesian approach. This model included the effects of contemporary group, age, and individual heterozygosity as covariates. In addition, direct additive genetic and random residual effects were also analyzed. Heritability estimated for BFT (0.16), REA (0.50), and BW (0.44) indicated their potential for genetic improvements and response to selection processes. Furthermore, genetic correlations between BW and the remaining traits were high (P > 0.50), suggesting that selection for BW could improve REA and BFT. On the other hand, genetic correlation between BFT and REA was low (P = 0.39 ± 0.17), and included considerable variations, suggesting that these traits can be jointly included as selection criteria without influencing each other. We found that REA and BFT responded to the selection processes, as measured by ultrasound. Therefore, selection for yearling weight results in changes in REA and BFT.
Resumo:
Dry eye syndrome is one of the most commonly reported eye health conditions. Dynamic-area highspeed videokeratoscopy (DA-HSV) represents a promising alternative to the most invasive clinical methods for the assessment of the tear film surface quality (TFSQ), particularly as Placido-disk videokeratoscopy is both relatively inexpensive and widely used for corneal topography assessment. Hence, improving this technique to diagnose dry eye is of clinical significance and the aim of this work. First, a novel ray-tracing model is proposed that simulates the formation of a Placido image. This model shows the relationship between tear film topography changes and the obtained Placido image and serves as a benchmark for the assessment of indicators of the ring’s regularity. Further, a novel block-feature TFSQ indicator is proposed for detecting dry eye from a series of DA-HSV measurements. The results of the new indicator evaluated on data from a retrospective clinical study, which contains 22 normal and 12 dry eyes, have shown a substantial improvement of the proposed technique to discriminate dry eye from normal tear film subjects. The best discrimination was obtained under suppressed blinking conditions. In conclusion,this work highlights the potential of the DA-HSV as a clinical tool to diagnose dry eye syndrome.
Resumo:
Fino ad oggi la mobilità urbana si è affidata in particolar modo alla motorizzazione privata. Occorre considerare anche altre alternative di trasporto per garantire una mobilità più sostenibile ed efficace all’interno delle nostre aree urbane. Una di queste alternative è costituita dalla bicicletta, che deve essere considerata un’autentica alternativa di trasporto, che può facilmente contribuire, assieme ad altre, a ridurre l’attuale inefficiente dipendenza dall’automobile. La progettazione dei percorsi ciclo-pedonali richiede collegamenti sicuri, diretti, ben segnalati e confortevoli, che assicurino una mobilità indipendente e protetta per tutti. In questo lavoro di tesi stato proposto un questionario che ha lo scopo di dare un ritratto immediato degli utenti ciclabili che percorrono i campi prova analizzati, confrontare i risultati ottenuti e verificare quali parametri sono ritenuti di maggiore importanza per l’utente medio. Nella seconda fase e punto focale di tale lavoro di ricerca è stata svolta un’attenta analisi delle possibili scelte e problematiche di un particolare caso reale. In particolare, sono stati valutati gli elementi che il conducente del velocipede scansiona con lo sguardo durante la guida, cercando informazioni significative per la posizione spaziale e temporale in cui si trova. La ricerca è stata condotta mediante l’utilizzo della strumentazione Mobile Eye-XG che permette il rilievo in continuo dello sguardo dei conducenti durante la guida. Il campo prova riguarda il percorso “Sabotino”, composto da due itinerari situati all’interno dell’area urbana di Bologna, la Tangenziale Ovest delle biciclette e la “ciclabile vecchia” Sabotino. Dalle informazioni ricavate dall’analisi, si è cercato infine di ipotizzare delle possibili ed efficaci migliorie, che possano incentivare l’uso della bicicletta e la sicurezza nei confronti della mobilità lenta, migliorando le prestazioni della pista e aumentando gli standard.
Resumo:
Objectives. To evaluate the performance of the dynamic-area high-speed videokeratoscopy technique in the assessment of tear film surface quality with and without the presence of soft contact lenses on eye. Methods. Retrospective data from a tear film study using basic high-speed videokeratoscopy, captured at 25 frames per second, (Kopf et al., 2008, J Optom) were used. Eleven subjects had tear film analysis conducted in the morning, midday and evening on the first and seventh day of one week of no lens wear. Five of the eleven subjects then completed an extra week of hydrogel lens wear followed by a week of silicone hydrogel lens wear. Analysis was performed on a 6 second period of the inter-blink recording. The dynamic-area high-speed videokeratoscopy technique uses the maximum available area of Placido ring pattern reflected from the tear interface and eliminates regions of disturbance due to shadows from the eyelashes. A value of tear film surface quality was derived using image rocessing techniques, based on the quality of the reflected ring pattern orientation. Results. The group mean tear film surface quality and the standard deviations for each of the conditions (bare eye, hydrogel lens, and silicone hydrogel lens) showed a much lower coefficient of variation than previous methods (average reduction of about 92%). Bare eye measurements from the right and left eyes of eleven individuals showed high correlation values (Pearson’s correlation r = 0.73, p < 0.05). Repeated measures ANOVA across the 6 second period of measurement in the normal inter-blink period for the bare eye condition showed no statistically significant changes. However, across the 6 second inter-blink period with both contact lenses, statistically significant changes were observed (p < 0.001) for both types of contact lens material. Overall, wearing hydrogel and silicone hydrogel lenses caused the tear film surface quality to worsen compared with the bare eye condition (repeated measures ANOVA, p < 0.0001 for both hydrogel and silicone hydrogel). Conclusions. The results suggest that the dynamic-area method of high-speed videokeratoscopy was able to distinguish and quantify the subtle, but systematic worsening of tear film surface quality in the inter-blink interval in contact lens wear. It was also able to clearly show a difference between bare eye and contact lens wearing conditions.
Resumo:
A new method for noninvasive assessment of tear film surface quality (TFSQ) is proposed. The method is based on high-speed videokeratoscopy in which the corneal area for the analysis is dynamically estimated in a manner that removes videokeratoscopy interference from the shadows of eyelashes but not that related to the poor quality of the precorneal tear film that is of interest. The separation between the two types of seemingly similar videokeratoscopy interference is achieved by region-based classification in which the overall noise is first separated from the useful signal (unaltered videokeratoscopy pattern), followed by a dedicated interference classification algorithm that distinguishes between the two considered interferences. The proposed technique provides a much wider corneal area for the analysis of TFSQ than the previously reported techniques. A preliminary study with the proposed technique, carried out for a range of anterior eye conditions, showed an effective behavior in terms of noise to signal separation, interference classification, as well as consistent TFSQ results. Subsequently, the method proved to be able to not only discriminate between the bare eye and the lens on eye conditions but also to have the potential to discriminate between the two types of contact lenses.
Resumo:
PURPOSE. To measure tear film surface quality in healthy and dry eye subjects using three noninvasive techniques of tear film quality assessment and to establish the ability of these noninvasive techniques to predict dry eye. METHODS. Thirty four subjects participated in the study, and were classified as dry eye or normal, based on standard clinical assessments. Three non-invasive techniques were applied for measurement of tear film surface quality: dynamic-area high-speed videokeratoscopy (HSV), wavefront sensing (DWS) and lateral shearing interferometry (LSI). The measurements were performed in both natural blinking conditions (NBC) and in suppressed blinking conditions (SBC). RESULTS. In order to investigate the capability of each method to discriminate dry eye subjects from normal subjects, the receiver operating curve (ROC) was calculated and then the area under the curve (AUC) was extracted. The best result was obtained for the LSI technique (AUC=0.80 in SBC and AUC=0.73 in NBC), which was followed by HSV (AUC=0.72 in SBC and AUC=0.71 in NBC). The best result for DWS was AUC=0.64 obtained for changes in vertical coma in suppressed blinking conditions, while for normal blinking conditions the results were poorer. CONCLUSIONS. Non-invasive techniques of tear film surface assessment can be used for predicting dry eye and this can be achieved in natural blinking as well as suppressed blinking conditions. In this study, LSI showed the best detection performance, closely followed by the dynamic-area HSV. The wavefront sensing technique was less powerful, particularly in natural blinking conditions.
Resumo:
This study evaluated the effect of eye muscle area (EMA), ossification, carcass weight, marbling and rib fat depth on the incidence of dark cutting (pH u > 5.7) using routinely collected Meat Standards Australia (MSA) data. Data was obtained from 204,072 carcasses at a Western Australian processor between 2002 and 2008. Binomial data of pH u compliance was analysed using a logit model in a Bayesian framework. Increasing eye muscle area from 40 to 80 cm 2, increased pH u compliance by around 14% (P < 0.001) in carcasses less than 350 kg. As carcass weight increased from 150 kg to 220 kg, compliance increased by 13% (P < 0.001) and younger cattle with lower ossification were also 7% more compliant (P < 0.001). As rib fat depth increased from 0 to 20 mm, pH u compliance increased by around 10% (P < 0.001) yet marbling had no effect on dark cutting. Increasing musculature and growth combined with good nutrition will minimise dark cutting beef in Australia.
Resumo:
Purpose: To investigate the association between conjunctival ultraviolet autofluorescence (UVAF), a biomarker of ocular ultraviolet radiation (UVR) exposure, and prevalent pterygium. Methods: We conducted a cross-sectional study on Norfolk Island, South Pacific. All permanent residents aged ‡15 were invited to participate. Participants completed a sun exposure questionnaire and underwent autorefraction and slit lamp biomicroscope examination. Area of conjunctival UVAF (sum of temporal ⁄ nasal area in right and left eyes) was determined using computerized methods. Multivariate logistic and linear regression models were used to estimate the associations with pterygia and UVAF, respectively. Results: Of 641 participants, 70 people (10.9%) had pterygium in one or both eyes, and prevalence was higher in males (15.0% versus 7.7%, p = 0.003). Significant independent associations with pterygium in any eye were UVAF (per 10 mm2) [odds ratio (OR) 1.16, 95% confidence interval (CI) 1.16–1.28, p = 0.002], tanning skin phenotype (OR 2.17,1.20–3.92, p = 0.010) and spending more than three-quarters of the day outside (OR 2.22, 1.20–4.09, p = 0.011). Increasing quartile of UVAF was associated with increased risk of pterygium following adjustment of age, sex and time outdoors (pTrend = 0.002). Independent associations with increasing UVAF (per 10 mm2) were decreasing age, time outdoors, skin type and male gender (all p < 0.001). UVAF area correlated well with the duration of outdoor activity (pTrend < 0.001). Conclusion: Pterygium occurs in approximately one-tenth of Norfolk Islanders. Increasing conjunctival UVAF is associated with prevalent pterygia, confirming earlier epidemiological, laboratory and ray-tracing studies that pterygia are associated with UVR. Protection from the sun should be encouraged to reduce the prevalence of pterygium in the community.