993 resultados para load planning


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the influence of adhesive layer thickness (ADL) on the resin-dentin bond strength of two adhesive systems (AS) after ther-mal and mechanical loading (TML). A flat superficial dentin surface was exposed with 600-grit SiC paper on 40 molars. After primer application, the adhesive layer of Scotchbond Multipurpose (SBMP) or Clearfil SE Bond (CSEB) was applied in one or two layers to a delimited area (52 mm(2)) and resin blocks (Filtek 2250) were built incrementally: Half of the sample was stored in distilled water (37 C, 24 hours) and submitted to thermal (1,000; 5 degrees-55 degrees C) and mechanical cycles (500,000; 10kgf) [TML]. The other half was stored in distilled water (72 hours). The teeth were then sectioned to obtain sticks (0.8 mm(2)) to be tested under tensile mode (1.0 mm/minute). The fracture mode was analyzed at 400x. The BS from all sticks from the same tooth was averaged for statistical purposes. The data was analyzed by three-way ANOVA. The x(2) test was used (p<0.05) to compare the frequency of pre-testing failure specimens. Higher BS values were observed for SBMP regardless of the ADL. The TML reduced the BS values irrespective of the adhesive employed and the ADL. A higher frequency of pre-testing failure specimens was observed for the cycled groups. A thicker adhesive layer, acting as an intermediate flexible layer, did not min-imize the damage caused by thermal/mechanical load cycling for a three-step etch-and-rinse and two-step self-etch system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The foramen of Vesalius (FV) is located in the greater wing of the sphenoid bone between the foramen ovale (FO) and the foramen rotundum in an intracranial view. The FO allows the passage of the mandibular branch of trigeminal nerve, which is the target of the trigeminal radiofrequency rhizotomy. We analyzed its location, morphology, morphometry and interrelation among other foramina. 400 macerated adult human skulls were examined. A digital microscope (Dino-Lite plus(A (R))) was used to capture images from the FV. A digital caliper was used to perform the measurements of the distance between the FV and other foramina (FO, foramen spinosum and the carotid canal) in an extracranial view of the skull base. In the 400 analyzed skulls, the FV was identified in 135 skulls (33.75%) and absent on both sides in 265 skulls (66.25%). The FV was observed present bilaterally in 15.5% of the skulls. The incidence of unilateral foramen was 18.25% of the skulls of which 7.75% on right side and 10.5% on left side. The diameter of the FV was measured and we found an average value of 0.65 mm, on right side 0.63 mm and on the left side 0.67 mm. We verified that positive correlations were statistically significant among the three analyzed distances. This study intends to offer specific anatomical data with morphological patterns (macroscopic and mesoscopic) to increase the understanding of the FV features as frequency, incidence and important distances among adjacent foramina.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report provides a benchmark of progress in regional planning for natural resource management in Queensland and the tropical savannas region of northern Australia during 2004. It is based on a review of regional plans and planning processes against a set of pre-defined criteria designed specifically to evaluate regional planning arrangements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In cantilevered implant-supported complete prosthesis, the abutments` different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis. A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges. Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase. Abutment`s height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis. To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment`s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osny Ferreira-Junior, Luciana Dorigatti de Avila, Marcelo Bonifacio da Silva Sampieri, Eduardo Dias-Ribeiro, Weiliang Chen, Song Fan. Impacted Lower Third Molar Fused with a Supernumerary Tooth-Diagnosis and Treatment Planning Using Cone-Beam Computed Tomography. International Journal of Oral Science, 1(4): 224-228, 2009 This paper reported a case of fusion between an impacted third molar and a supernumerary tooth, in which a surgical intervention was carried out, with the objective of removing the dental elements. The panoramic radiography was complemented by the Donovan`s radiographic technique; but because of the proximity of the dental element to the mandibular ramus, it was not possible to have a final fusion diagnosis. Hence, the Cone-Beam Computed Tomography-which provides precise three-dimensional information-was used to determinate the fusion diagnosis and also to help in the surgical planning. In this case report we observed that the periapical, occlusal and panoramic were not able to show details which could only be examined through the cone-beam computed tomography.