971 resultados para linear measurements


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The increasing availability of large, detailed digital representations of the Earth’s surface demands the application of objective and quantitative analyses. Given recent advances in the understanding of the mechanisms of formation of linear bedform features from a range of environments, objective measurement of their wavelength, orientation, crest and trough positions, height and asymmetry is highly desirable. These parameters are also of use when determining observation-based parameters for use in many applications such as numerical modelling, surface classification and sediment transport pathway analysis. Here, we (i) adapt and extend extant techniques to provide a suite of semi-automatic tools which calculate crest orientation, wavelength, height, asymmetry direction and asymmetry ratios of bedforms, and then (ii) undertake sensitivity tests on synthetic data, increasingly complex seabeds and a very large-scale (39 000km2) aeolian dune system. The automated results are compared with traditional, manually derived,measurements at each stage. This new approach successfully analyses different types of topographic data (from aeolian and marine environments) from a range of sources, with tens of millions of data points being processed in a semi-automated and objective manner within minutes rather than hours or days. The results from these analyses show there is significant variability in all measurable parameters in what might otherwise be considered uniform bedform fields. For example, the dunes of the Rub’ al Khali on the Arabian peninsula are shown to exhibit deviations in dimensions from global trends. Morphological and dune asymmetry analysis of the Rub’ al Khali suggests parts of the sand sea may be adjusting to a changed wind regime from that during their formation 100 to 10 ka BP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrical transport and structural properties of platinum nanowires, deposited using the focussed ion beam method have been investigated. Energy dispersive X-ray spectroscopy reveals metal-rich grains (atomic composition 31% Pt and 50% Ga) in a largely non-metallic matrix of C, O and Si. Resistivity measurements (15-300 K) reveal a negative temperature coefficient with the room-temperature resistivity 80-300 times higher than that of bulk Pt. Temperature dependent current-voltage characteristics exhibit non-linear behaviour in the entire range investigated. The conductance spectra indicate increasing non-linearity with decreasing temperature, reaching 4% at 15 K. The observed electrical behaviour is explained in terms of a model for inter-grain tunnelling in disordered media, a mechanism that is consistent with the strongly disordered nature of the nanowires observed in the structure and composition analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A single layer, frequency selective surface based, sub-millimeter wave transmission polarizer is presented that converts incident slant linear 45° polarization into circular polarization upon transmission. The polarization convertor consists of a 30 mm diameter 10 thick silicon reinforced metalized screen containing 2700 resonator cells and perforated with nested split ring slot apertures. The screen was designed and optimized using CST Microwave Studio and predictions were validated experimentally by transmission measurements over the 250-365 GHz frequency range. This frequency range is used for remote environmental monitoring and 325 GHz represents a molecular emission line for H2O. The results obtained show good agreement between measured and modeled predictions. The measured 3 dB axial ratio bandwidth was 11.75%, measured minimum Axial Ratio was 0.19 dB and the measured insertion loss of the single layer screen was 3.38 dB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is noted that the determination of an oscillation frequency by used of the power spectrum of measured time series is susceptible to filtering of the signal. Similarly, frequency measurements made by period counting can yield different, results depending on how the signal is filtered for noise reduction. In an attempt to eliminate these ambiguities, a new measure of frequency, based on an approximate reconstruction of the phase-space trajectory of the oscillator from the signal, is introduced. This measure is shown to be invariant under linear filtering. For this reason, it is also inaccessible by spectral methods. The effect of filtering on frequency for weakly nonlinear, noisy oscillators, to which this definition applies only imperfectly, is quantified. This work provides the theoretical basis for frequency measurements employing MIRVA filtering.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method for obtaining quantitative information about electric field and charge distributions from proton imaging measurements of laser-induced plasmas is presented. A parameterised charge distribution is used as target plasma. The deflection of a proton beam by the electric field of such a plasma is simulated numerically as well as the resulting proton density, which will be obtained on a screen behind the plasma according to the proton imaging technique. The parameters of the specific charge distributions are delivered by a combination of linear regression and nonlinear fitting of the calculated proton density distribution to the measured optical density of a radiochromic film screen changed by proton exposure. It is shown that superpositions of spherical Gaussian charge distributions as target plasma are sufficient to simulate various structures in proton imaging measurements, which makes this method very flexible.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The concentration of organic acids in anaerobic digesters is one of the most critical parameters for monitoring and advanced control of anaerobic digestion processes. Thus, a reliable online-measurement system is absolutely necessary. A novel approach to obtaining these measurements indirectly and online using UV/vis spectroscopic probes, in conjunction with powerful pattern recognition methods, is presented in this paper. An UV/vis spectroscopic probe from S::CAN is used in combination with a custom-built dilution system to monitor the absorption of fully fermented sludge at a spectrum from 200 to 750 nm. Advanced pattern recognition methods are then used to map the non-linear relationship between measured absorption spectra to laboratory measurements of organic acid concentrations. Linear discriminant analysis, generalized discriminant analysis (GerDA), support vector machines (SVM), relevance vector machines, random forest and neural networks are investigated for this purpose and their performance compared. To validate the approach, online measurements have been taken at a full-scale 1.3-MW industrial biogas plant. Results show that whereas some of the methods considered do not yield satisfactory results, accurate prediction of organic acid concentration ranges can be obtained with both GerDA and SVM-based classifiers, with classification rates in excess of 87% achieved on test data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In linear cascade wind tunnel tests, a high level of pitchwise periodicity is desirable to reproduce the azimuthal periodicity in the stage of an axial compressor or turbine. Transonic tests in a cascade wind tunnel with open jet boundaries have been shown to suffer from spurious waves, reflected at the jet boundary, that compromise the flow periodicity in pitch. This problem can be tackled by placing at this boundary a slotted tailboard with a specific wall void ratio s and pitch angle a. The optimal value of the s-a pair depends on the test section geometry and on the tunnel running conditions. An inviscid two-dimensional numerical method has been developed to predict transonic linear cascade flows, with and without a tailboard, and quantify the nonperiodicity in the discharge. This method includes a new computational boundary condition to model the effects of the tailboard slots on the cascade interior flow. This method has been applied to a six-blade turbine nozzle cascade, transonically tested at the University of Leicester. The numerical results identified a specific slotted tailboard geometry, able to minimize the spurious reflected waves and regain some pitchwise flow periodicity. The wind tunnel open jet test section was redesigned accordingly. Pressure measurements at the cascade outlet and synchronous spark schlieren visualization of the test section, with and without the optimized slotted tailboard, have confirmed the gain in pitchwise periodicity predicted by the numerical model. Copyright © 2006 by ASME.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The dose delivery accuracy of 30 clinical step and shoot intensity modulated radiation therapy plans was investigated using the single integrated multileaf collimator controller of the Varian Truebeam linear accelerator (linac) (Varian Medical Systems, Palo Alto, CA) and compared with the dose delivery accuracy on a previous generation Varian 2100CD C-Series linac.

Methods and Materials: Ten prostate, 10 prostate and pelvic node, and 10 head-and-neck cases were investigated in this study. Dose delivery accuracy on each linac was assessed using Farmer ionization chamber point dose measurements, 2-dimensional planar ionization chamber array measurements, and the corresponding Varian dynamic log files. Absolute point dose measurements, fluence delivery accuracy, leaf position accuracy, and the overshoot effect were assessed for each plan.

Results: Absolute point dose delivery accuracy increased by 1.5% on the Truebeam compared with the 2100CD linac. No improvement in fluence delivery accuracy between the linacs, at a gamma criterion of 3%/3 mm was measured using the 2-dimensional ionization chamber array, with median (interquartile range) gamma passing rates of 98.99% (97.70%-99.72%) and 99.28% (98.26%-99.75%) for the Truebeam and 2100CD linacs, respectively. Varian log files also showed no improvement in fluence delivery between the linacs at 3%/3 mm, with median gamma passing rates of 99.97% (99.93%-99.99%) and 99.98% (99.94%-100%) for the Truebeam and 2100CD linacs, respectively. However, log files revealed improved leaf position accuracy and fluence delivery at 1%/1 mm criterion on the Truebeam (99.87%; 99.78%-99.94%) compared with the 2100CD linac (97.87%; 91.93%-99.49%). The overshoot effect, characterized on the 2100CD linac, was not observed on the Truebeam.

Conclusions: The integrated multileaf collimator controller on the Varian Truebeam improves clinical treatment delivery accuracy of step and shoot intensity modulated radiation therapy fields compared with delivery on a Varian C-series linac. © 2014.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work investigated the differences between multileaf collimator (MLC) positioning accuracy determined using either log files or electronic portal imaging devices (EPID) and then assessed the possibility of reducing patient specific quality control (QC) via phantom-less methodologies. In-house software was developed, and validated, to track MLC positional accuracy with the rotational and static gantry picket fence tests using an integrated electronic portal image. This software was used to monitor MLC daily performance over a 1 year period for two Varian TrueBeam linear accelerators, with the results directly compared with MLC positions determined using leaf trajectory log files. This software was validated by introducing known shifts and collimator errors. Skewness of the MLCs was found to be 0.03 ± 0.06° (mean ±1 standard deviation (SD)) and was dependent on whether the collimator was rotated manually or automatically. Trajectory log files, analysed using in-house software, showed average MLC positioning errors with a magnitude of 0.004 ± 0.003 mm (rotational) and 0.004 ± 0.011 mm (static) across two TrueBeam units over 1 year (mean ±1 SD). These ranges, as indicated by the SD, were lower than the related average MLC positioning errors of 0.000 ± 0.025 mm (rotational) and 0.000 ± 0.039 mm (static) that were obtained using the in-house EPID based software. The range of EPID measured MLC positional errors was larger due to the inherent uncertainties of the procedure. Over the duration of the study, multiple MLC positional errors were detected using the EPID based software but these same errors were not detected using the trajectory log files. This work shows the importance of increasing linac specific QC when phantom-less methodologies, such as the use of log files, are used to reduce patient specific QC. Tolerances of 0.25 mm have been created for the MLC positional errors using the EPID-based automated picket fence test. The software allows diagnosis of any specific leaf that needs repair and gives an indication as to the course of action that is required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the results of a search for the reactivation of active asteroid 176P/LINEAR during its 2011 perihelion passage using deep optical observations obtained before, during, and after that perihelion passage. Deep composite images of 176P constructed from data obtained between 2011 June and 2011 December show no visible signs of activity, while photometric measurements of the object during this period also show no significant brightness enhancements similar to that observed for 176P between 2005 November and 2005 December when it was previously observed to be active. An azimuthal search for dust emission likewise reveals no evidence for directed emission (i.e., a tail, as was previously observed for 176P), while a one-dimensional surface brightness profile analysis shows no indication of a spherically symmetric coma at any time in 2011. We conclude that 176P did not in fact exhibit activity in 2011, at least not on the level on which it exhibited activity in 2005, and suggest that this could be due to the devolatization or mantling of the active site responsible for its activity in 2005.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a statistical model for the thermal behaviour of the line model based on lab tests and field measurements. This model is based on Partial Least Squares (PLS) multi regression and is used for the Dynamic Line Rating (DLR) in a wind intensive area. DLR provides extra capacity to the line, over the traditional seasonal static rating, which makes it possible to defer the need for reinforcement the existing network or building new lines. The proposed PLS model has a number of appealing features; the model is linear, so it is straightforward to use for predicting the line rating for future periods using the available weather forecast. Unlike the available physical models, the proposed model does not require any physical parameters of the line, which avoids the inaccuracies resulting from the errors and/or variations in these parameters. The developed model is compared with physical model, the Cigre model, and has shown very good accuracy in predicting the conductor temperature as well as in determining the line rating for future time periods. 

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transonic tests in linear cascade wind tunnels can suffer
from significant test section boundary interference effects in pitch. A slotted tailboard has been designed and optimised with an in-house Euler numerical method to reduce such ef- fects. Wind tunnel measurements on an overspeed Mach 1.27 discharge from a Rolls-Royce T2 cascade, featuring strong end-wall shock-induced interference, showed a 77% reduction in the flow pitchwise periodicity error with the optimised tail- board, with respect to the baseline open-jet cascade flow. Two-dimensional Euler predictions were also cross-validated against a three-dimensional Reynolds averaged computation, to explore the three-dimensionality of the discharge

Relevância:

30.00% 30.00%

Publicador:

Resumo:

No presente trabalho propõe-se estudar a tensão superficial de vários perfluorocarbonetos lineares, cíclicos, aromáticos e [alfa]-substituídos bem como líquidos iónicos com o catião imidazolium em comum. Apesar do seu interesse inerente, informação sobre esta propriedade para os compostos seleccionados é escassa e quando disponível apresenta discrepâncias consideráveis entre si. As medições foram realizadas no intervalo de temperaturas (283 to 353) K usando o método do anel de Du Noüy. Para os fluorocarbonetos, os dados experimentais demonstram que a estrutura molecular é o factor primordial no comportamento da superfície uma vez que os fluorocarbonetos aromáticos apresentam a tensão superficial mais elevada, seguida pelos fluorocarbonetos cíclicos e substituídos. Os perfluorocarbonetos lineares apresentam os menores valores de tensão superficial, aumentando ligeiramente com o aumento do número de carbonos. Os líquidos iónicos estudados foram seleccionados com o objectivo de fornecerem um estudo compreensivo sobre a influência do tamanho da cadeia alquílica do catião, o número de substituições no catião e a influência do anião. A influência do conteúdo de água na tensão superficial foi estudada em função da temperatura e da fracção molar de água para o liquido iónico mais hidrofóbico, [omim][PF6], e para o mais higroscópico, [bmim][PF6]. As funções termodinâmicas de superfície, como a entropia e entalpia de superfície, foram derivadas a partir da dependência da tensão superficial com a temperatura. Os dados obtidos para o fluorocarbonetos foram comparados com a correlação proposta por Faizullin, apresentando um desvio inferior a 4 % e demonstrando a sua aplicabilidade para com esta classe de compostos. A metodologia adoptada neste trabalho requer o conhecimento das densidades dos compostos de modo a aplicar a necessária correcção hidrostática. Contudo, para os líquidos iónicos esta informação é limitada ou mesmo inexistente. Por este motivo realizaram-se medições de densidade em função da pressão (0.10 < p/MPa < 10.0) e da temperatura (293.15 < T/K < 393.15). Desta dependência, as propriedades termodinâmicas, tais como compressibilidade isotérmica, expansividade isobárica, coeficiente térmico da pressão e dependência da capacidade calorífica com a pressão foram investigadas. A influência do teor de água na densidade foi também estudada para o líquido iónico mais hidrofóbico, [omim][PF6]. Um modelo simples de volume-ideal foi aplicado de forma preditiva para os volumes molares dos líquidos iónicos, em condições ambientais, descrevendo bem os dados experimentais. ABSTRACT: This work aims at studying the surface tension of some linear, cyclic, aromatic, [alfa]-substituted perfluorocarbons and imidazolium based ionic liquids. Despite its fundamental interest, information about this property for these compounds is scarce and the available data present strong discrepancies among each other. The measurements were carried out in the temperature range (283 to 353) K with the Du Noüy ring method. For the fluorocarbons, the analysis of the experimental data shows that the molecular structure is the main factor in the surface since the aromatic fluorocompounds present the highest surface tensions, followed by the cyclic and substituted fluorocompounds. The linear n-perfluoroalkanes exhibit the lowest surface tension values, slightly increasing with the carbon number. The set of selected ionic liquids was chosen to provide a comprehensive study of the influence of the cation alkyl chain length, the number of cation substitutions and the anion on the properties under study. The influence of water content in the surface tension was studied for several ILs as a function of the temperature as well as a function of water mole fraction, for the most hydrophobic IL investigated, [omim][PF6], and one hygroscopic IL, [bmim][PF6]. The surface thermodynamic functions such as surface entropy and enthalpy were derived from the temperature dependence of the surface tension values. The perfluorocarbons experimental data were compared against the Faizullin correlation, and it is shown that this correlation describes the measured surface tensions with deviations inferior to 4 %. The methodology adopted in this work requires the knowledge of the densities of the compounds under study in order to apply an hydrostatic correction. However, for ionic liquids these information is scarse and in some cases unavailable. Therefore, experimental measurements of the pressure (0.10 < p/MPa < 10.0) and temperature (293.15 < T/K < 393.15) dependence of the density and derived thermodynamic properties, such as the isothermal compressibility, the isobaric expansivity, the thermal pressure coefficient, and the pressure dependence of the heat capacity of several imidazolium-based ionic were determined. The influence of water content in the density was also studied for the most hydrophobic IL used, [omim][PF6]. A simple ideal-volume model was employed for the prediction of the imidazolium molar volumes at ambient conditions, which proved to agree well with the experimental results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is on the implementation of a dual axis positioning system controller. The system was designed to be used for space-dependent ultrasound signal acquisition problems, such as pressure field mapping. The work developed can be grouped in two main subjects: hardware and software. Each axis includes one stepper motor connected to a driver circuit, which is then connected to a processing unit. The graphical user interface is simple and clear for the user. The system resolution was computed as 127 mu m with an accuracy of 2.44 mu m. Although the target application is ultrasound signal acquisition, the controller can be applied to other devices that has up to four stepper motors. The application was developed as an open source software, thus it can be used or changed to fit different purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Elastic properties of sodium doped Lithium potassium sulphate, LiK0.9Na0.1SO4, crystal has been studied by ultrasonic Pulse Echo Overlap [PEO] technique and are reported for the first time. The controversy regarding the type of crystal found while growth is performed at 35 °C with equimolar fraction of Li2SO4H2O, K2SO4 and Na2SO4 has been resolved by studying the elastic properties. The importance of this crystal is that it exhibits pyroelectric, ferroelectric and electro optic properties. It is simultaneously ferroelastic and superionic. The elastic properties of LiK0.9Na0.1SO4 crystal are well studied by measuring ultrasonic velocity in the crystal in certain specified crystallographic directions and evaluating the elastic stiffness constants, compliance constants and Poisson’s ratios. The anisotropy in the elastic properties of the crystal are well explained by the pictorial representation of the surface plots of phase velocity, slowness and linear compressibility in a-b and a-c planes.