994 resultados para iodine-125


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pd-catalysed reactions of 2-Cl, 2-Br and 2-I derivatives of a 6-chloropurine nucleoside with benzamide have been compared, using Pd2dba3, Xantphos and Cs2CO3 in toluene, between 20 and 80 °C. The reactivity order was 2-I > 2-Br > 6-Cl ≫ 2-Cl. The 2-I substituent could be replaced even at 0 °C, under conditions disclosed here for the first time. On the other hand, the replacement of the chlorine atom at position 2 (2-Cl) required 110 °C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar, retrospectivamente, o resultado do tratamento conservador do melanoma de coróide, por meio de braquiterapia, usando placas episclerais de iodo-125 (modelo 6711, Amershan). MATERIAIS E MÉTODOS: Foram avaliados 49 pacientes portadores de melanoma de coróide tratados no Hospital do Câncer, São Paulo, SP, de março de 2001 a janeiro de 2003. Os seguintes parâmetros foram analisados e correlacionados ao controle local e sobrevida: sexo, idade, dimensões da lesão, tempo de tratamento e doses no ápice e base das lesões. RESULTADOS: Com diâmetro máximo da base do tumor de 17 mm e altura máxima de 12 mm, observamos que as doses na base do tumor variaram de 213 a 463 Gy (mediana de 347 Gy) e no ápice, de 51 a 250 Gy (mediana de 91 Gy). As taxas de preservação ocular, sobrevida livre de doença e conservação ocular, atuariais em dois anos, foram de 96%, 93,5% e 96,3%, respectivamente. Através de análise univariada, o único fator prognóstico para controle local nesta análise foi a altura do tumor menor que 6 mm (p = 0,0348). CONCLUSÃO: A braquiterapia levou a uma taxa bastante satisfatória de controle local, confirmando que a altura do tumor é um dos fatores prognósticos importantes desse parâmetro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Analisar, por meio de um modelo computacional da região ocular, as características da distribuição da dose utilizando placas contendo iodo-125 e rutênio/ródio-106. MATERIAIS E MÉTODOS: Foi utilizado um modelo computacional de voxels da região ocular incluindo os diversos tecidos, com a placa posicionada sobre a esclera. O código Monte Carlo foi utilizado para simular a irradiação. A distribuição da dose é apresentada por curvas de isodoses. RESULTADOS: As simulações computacionais apresentam a distribuição da dose no interior do bulbo e nas estruturas externas. Os resultados permitem comparar a distribuição espacial das doses geradas por partículas beta e por fótons. As simulações mostram que a aplicação de sementes de iodo-125 implica alta dose no cristalino, enquanto o rutênio/ródio-106 produz alta dose na superfície da esclera. CONCLUSÃO: A dose no cristalino depende da espessura do tumor, da posição e do diâmetro da placa, e do radionuclídeo utilizado. No presente estudo, a fonte de rutênio/ródio-106 é recomendada para tumores de dimensões reduzidas. A irradiação com iodo-125 gera doses maiores no cristalino do que a irradiação com rutênio/ródio-106. O valor máximo de dose no cristalino corresponde a 12,75% do valor máximo de dose com iodo-125 e apenas 0,005% para rutênio/ródio-106.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: O presente artigo visa apresentar um estudo dosimétrico comparativo de braquiterapia de próstata com sementes de I-125 e Pd-103. MATERIAIS E MÉTODOS: Um protocolo adotado para ambos os implantes com 148 sementes foi simulado em um fantoma tridimensional heterogêneo de pelve por meio dos códigos SISCODES/MCNP5. Histogramas dose-volume na próstata, bexiga e reto, índices de doses D10, D30, D90, D0,5cc, D2cc e D7cc, e representações de distribuição espacial de dose foram avaliados. RESULTADOS: A atividade inicial de cada semente de I-125, para que D90 seja equivalente à dose de prescrição, foi calculada em 0,42 mCi, e de Pd-103, em 0,94 mCi. A dose máxima na uretra foi 90% e 108% da dose de prescrição para I-125 e Pd-103, respectivamente. A D2cc para I-125 foi 30 Gy no reto e 127 Gy na bexiga, e para Pd-103 foi 29 Gy no reto e 189 Gy na bexiga. A D10 no osso do púbis foi 144 Gy para I-125 e 66 Gy para Pd-103. CONCLUSÃO: Os resultados indicam que os implantes de Pd-103 e I-125 puderam depositar a dose prescrita no volume alvo. Entre os achados, observou-se excessiva exposição de radiação nos ossos da pelve, principalmente no protocolo com I-125.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results Intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h-1.p-1.s, respectively, on the healthy tissue, on the balloon periphery and on the I 1 and I 2 tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h-1.p-1.s, respectively on the healthy tissue, on the target tumor and on the I 1 and I 2 infiltration zones. Conclusion Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

r1952, Carnegie Hall, New York.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data of methylene blue number and iodine number of activated carbons samples were calibrated against the respective surface area, micropore volume and total pore volume using multiple regression. The models obtained from the calibrations were used in predicting these physical properties of a test group of activated carbon samples produced from several raw materials. In all cases, the predicted values were in good agreement with the expected values. The method allows extracting more information from the methylene blue and iodine adsorption studies than normally obtained with this type of material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVOS: calcular a sensibilidade, a especificidade e a acurácia das variáveis: idade da paciente, aspecto ultra-sonográfico e dosagem do marcador CA-125 para o diagnóstico diferencial entre tumores malignos e benignos do ovário. Estabelecer, ainda, índice de risco de malignidade (IRM) com a incorporação dessas três variáveis e calcular a sua sensibilidade, especificidade e acurácia para aquele diagnóstico diferencial. MÉTODOS: foram incluídas prospectivamente 100 pacientes portadoras de tumor do ovário com indicação cirúrgica. As variáveis idade, resultado da ultra-sonografia e níveis do CA-125 foram avaliadas isoladamente e depois em conjunto, sob a forma de índice (IRM). O estudo compreendeu a avaliação da sensibilidade, da especificidade e da acurácia diagnóstica e a aplicação das medidas: razão de probabilidade, razão de chances e dos testes: t de Student, chi² e regressão logística com análise uni e multivariada. RESULTADOS: para a variável idade, a sensibilidade, a especificidade e a acurácia diagnóstica foram respectivamente 58,8, 68,2 e 65,0%. Para a ultra-sonografia, 88,2, 77,3 e 81,0%. Para a dosagem do CA-125 esses valores foram 64,7, 74,2 e 71,0%. Quando as três variáveis foram agrupadas sob a forma do IRM observou-se sensibilidade de 76,5%, especificidade de 87,9% e acurácia diagnóstica de 84,0%. CONCLUSÕES: o IRM constituído pela associação das variáveis idade da paciente, resultado da ultra-sonografia e dosagem do CA-125 é indicador valioso para se distinguir entre tumores malignos e benignos de ovário, principalmente no que diz respeito à sua especificidade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Correlacionar os níveis séricos pré-operatórios do antígeno do câncer 125 (Ca-125) e os achados laparoscópicos em mulheres com sintomas dolorosos sugestivos de endometriose. MÉTODOS:Um estudo retrospectivo foi realizado incluindo todas as mulheres com sintomas de dor pélvica suspeitos para endometriose operadas por laparoscopia no período de janeiro de 2010 a março de 2013. As pacientes foram divididas em 2 grupos de acordo com a dosagem de Ca-125 (<35 U/mL e >35 U/mL). Subsequentemente, as pacientes com endometrioma ovariano foram excluídas e uma análise adicional foi conduzida novamente de acordo com os níveis do Ca-125. Os seguintes parâmetros foram comparados entre os grupos: presença de endometrioma, presença e número de lesões de endometriose profunda infiltrativa (EPI) e escore da American Society for Reproductive Medicine. A análise estatística foi realizada com o programa Statistica versão 8.0, usando o teste exato de Fisher, o teste t de Student e o teste Mann-Whitney, quando necessário. Os valores p<0,05 foram considerados estatisticamente significativos. RESULTADOS: Durante o período de estudo, um total de 350 mulheres foram submetidas a tratamento laparoscópico de endometriose. Cento e trinta pacientes (37,1%) apresentaram Ca-125 >35 U mL e 220 (62,9%) apresentaram Ca-125 <35 U/mL. A presença de endometrioma ovariano (47,7 versus 15,9%), lesões de EPI (99,6 versus 78,6%) e lesões de EPI intestinal (60 versus 30,9%) foi mais frequente, e o escore da AFSr foi maior (34 versus 6) no primeiro grupo. Na segunda análise, excluindo as pacientes com endometrioma ovariano (>35 U/mL=68 pacientes e <35 U/mL=185 pacientes), resultados semelhantes foram obtidos. A presença de lesões de EPI (91,2 versus 76,2%), lesões de EPI intestinal (63,2 versus 25,4%), lesões de EPI de bexiga (20,6 versus 4,8%) e lesões de EPI ureteral (7,3 versus 1,6%) foi mais frequente, e o escore da AFSr foi maior (10 versus 6) no grupo Ca-125>35 U/mL. CONCLUSÕES: Em mulheres com sintomas dolorosos pélvicos suspeitos para endometriose com dosagem pré-operatória de Ca-125 >35 U/mL, a investigação de EPI é mandatória, especialmente quando não se identifica endometrioma ovariano em exames de imagem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

kuv., 15 x 23 cm