702 resultados para intergranular corrosion
Resumo:
Although high tensile brassess of copper-zinc alloys (Manganese bronze) find extensive use in all marine applications, under aggressive sea-water, marine propellers cast out of such an alloy frequently suffer heavy corrosion damages due to dezincification. An interesting case history where a number of propellers have undergone dezincification in the Cochin backwaters is narrated in this paper.
Resumo:
Some presently used anti-fouling materials contain metals and other compounds, which are toxic in the environment. Coating products are not always stable, and there is a resulting pollution hazard. In particular if surfaces are poorly prepared and manufactures' instructions are not closely followed the application of anti-fouling substances becomes pointless and dangerous. In addition the salinity, constant biological activity and suspended particles make seawater a highly corrosive material in its own right.
Resumo:
The corrosion of ETP copper in natural seawater and putrid seawater has been studied. The corrosion rates and the sulphide content were monitored at regular intervals. In the absence of oxygen in the putrid media, the presence of sulphide favoured a reduction in the corrosion rate.
Resumo:
Several experimental techniques have been used in order to characterize the properties of multifilamentary Bi-2223 / Ag tapes. Pristine samples were investigated by electrical resistivity, current-voltage characteristics and DC magnetic moment measurements. Much emphasis is placed on comparing transport (direct) and magnetic (indirect) methods for determining the critical current density as well as the irreversibility line and resolving usual lacks of consistency due to the difference in measurement techniques and data analysis. The effect of an applied magnetic field, with various strengths and directions, is also studied and discussed. Next, the same combination of experiments was performed on bent tapes in order to bring out relevant information regarding the intergranular coupling. A modified Brandt model taking into account different types of defects within the superconducting filaments is proposed to reconciliate magnetic and transport data.
Resumo:
This communication aims at reporting the superconducting properties of Bi-2223/Ag tapes determined by using various measuring techniques. First, the original samples have been characterized by electrical resistance, AC susceptibility, and DC magnetization. The transport (intergranular) critical current vs. magnetic field was also determined at T = 77 K using pulsed currents up to 40 A. Next, the same combination of experiments was performed on bent tapes in order to bring out relevant information concerning the strength of the intergranular coupling. The results show that intergranular and intragranular currents differ by at least one order of magnitude. Finally, additional magnetic measurements were carried out in order to determine the anisotropy ratio Jc ab/Jc c, which was found to lie around 30. © 2002 Elsevier Science B.V. All rights reserved.
Resumo:
A new model is presented which describes the growth of the duplex layers of Fe3O4 on mild steel in high temperature, deoxygenated, neutral or alkaline aqueous solutions. It is shown that the layers grow by the ingress of water along oxide micropores to the metal-oxide interface and by the rate-limiting outward diffusion of Fe ions along oxide grain boundaries. The new model accounts for the observed temperature-dependence and pH-dependence of the corrosion, the morphology of inner and outer layer crystallites, the segregation of alloying elements, and the location of hydrogen evolution. The model can also be generalized to other steels and alloys. © 1989.
Resumo:
Stress corrosion studies of 50 Mn18Cr4 austenitic steel implanted with 120 keV N+, 100 keV Cr+, 200 keV and 400 keV Er+ ions were carried out by constant strain method in the nitrate solution. Surface composition and depth profiles of the implanted material were measured by AES sputter etching technique. The results exhibit that nitrogen implantation has no significant affection to the stress corrosion, but the chromium and erbium implantation has prolonged the incubation period of the stress corrosion cracking. (C) 1999 Kluwer Academic Publishers.
Resumo:
The corrosion inhibition behavior of benzotriazole, Na3PO4 and their mixture on carbon steel in 20 wt.% (0.628 mol l(-1)) tetra-n-butylammonium bromide aerated aqueous solution was investigated by weight-loss test, potentiodynamic polarization measurement, electrochemical impedance spectroscopy and scanning electron microscope/energy dispersive X-ray techniques. The inhibition action of BTA or SP or inhibitors mixture on the corrosion of carbon steel is mainly due to the inhibition of anodic process of corrosion. The results revealed that inhibitors mixtures have shown synergistic effects at lower concentration of inhibitors. At 2 g l(-1) BTA and 2 g l(-1) SP showed optimum enhanced inhibition compared with their individual effects.