1000 resultados para inductively coupled plasma-atomic emission spectroscopy (ICP-AES)


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Zeolites constitute one of the less common groups of tectosilicates. Zeoli1es with pores between -2 to 10 A in their structures have strong sorption capacity and are widely used in industrial and municipal operations to eliminate toxic substances. One of the major environmental problems in the mining activity is the treating of acid mine drainage. In this context, it is very important to search alternatives to manage this challenge. One feasible alternative is using zeolitic tuffs. The results of the physical-chemical characterization of zeolitic tuffs are the c1ue lo continue or not with deeper analysis and tests 01 acid mine drainage treatments. The guidelines to reach this purpose are the main goal of this work. Zeolite 1uff samples (named as XB_01 and XB_02) studied in this work were laken rn the Late Cretaceous Coastal Cayo Arch Ecuador, specifically in the Guaraguao River, showing the most important characteristics of heulandite zeolitic tuffs. X-ray powder diffraction (XRD) tests were developed in order to confirm that the samples belong to the heulandite-type zeoli1ic tuffs. Additionally, Thermogravimetric analysis (TG), Inductively coupled plasma-atomic emission spectroscopy (ICP-AES) and X-ray fluorescence (XRF) of the samples was necessary in order to define the Si/Al ratio and the main mineralogical phases. The XB_01 sample shows a higher ratio Si/Al than XB_02 sample. The cation exchange capacity est was the fundamental step to define the potentiality of the zeolite to use in acid mine drainage treatment Three methodologies were employed to determine the cation exchange capacity. The Cuban standard 626 and the ammonium exchange methodologies reflect results more consistent with each other. This is the starting point to continue with deeper studies such as breakthrough curves for heavy metal ions found in acid mine waters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We measured the chemical composition of 100 samples from the 250-m sediment sequence retrieved from Ocean Drilling Program Site 1256 in the Guatemala Basin using a newly developed microwave-assisted acid digestion protocol followed by inductively coupled plasma-atomic emission spectroscopy (ICP-AES) analysis. We compared these data gathered onshore to the results from the flux fusion prepared samples analyzed by shipboard ICP-AES during the leg and published in the Leg 206 Initial Reports volume, as well as to 35 randomly selected samples that were prepared by flux fusion at Boston University and analyzed by ICP-AES. Comparison of the newly developed acid digestion protocol to shore-based flux fusion demonstrates that the microwave-assisted acid technique yields a complete digestion, and because this procedure includes boric acid, it is safe for use with HF acid as boric acid neutralizes excess HF. The precision for nearly all elements in shore-based acid digestions is better than 3% of the measured values, including for elements such as Ni, Cr, and V, which are typically difficult to measure in biogenic-rich sediments. The shore-based flux fusions, while better than shipboard reported precision values (as expected), has precision better than 3% of their respective measured values for all major elements (Si, Al, Ti, Fe, Mn, Ca, Mg, Na, and K) and several trace elements (Ba and Sr). Results for P, Cr, Ni, V, Sc, and Zr are better than 5% of their measured values. Not only does the newly developed acid digestion provide better analytical results than the typical flux fusion method, the shore-based acid procedure also exhibits downhole lithologic and chemical characteristics similar to the shipboard flux fusion prepared results. These results confirm that the current shipboard methods are adequate for first-order geochemical interpretations and that the microwave-assisted acid digestion holds great potential to be the primary technique of preparing sediments on future Integrated Ocean Drilling Program expeditions.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Póster presentado en: 12th EUROPEAN SOFC & SOE FORUM 2016. 5–8 July 2016, KKL Lucerne/Switzerland

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The yeast Saccharomyces cerevisiae was immobilized in cubes of polyurethane foam and the ability of this immobilized material to separate Sb(III) and Sb(V) was investigated. A method based on sequential determination of total Sb (after on-line reduction of Sb(V) to Sb(III) with thiourea) and Sb(Ill) (after on-line solid-liquid phase extraction) by hydride generation inductively coupled plasma optical emission spectrometry is proposed. A flow system assembled with solenoid valves was used to manage all stages of the process. The effects of pH, sample loading and elution flow rates on solid-liquid phase extraction of Sb(III) were evaluated. Also, the parameters related to online pre-reduction (reaction coil and flow rates) were optimized. Detection limits of 0.8 and 0.15 mu g L-1 were obtained for total Sb and Sb (III), respectively. The proposed method was applied to the analysis of river water and effluent samples. The results obtained for the determination of total Sb were in agreement with expected values, including the river water Standard Reference Material 1640 certified by the National Institute of Standards and Technology (NIST). Recoveries of Sb(III) and Sb(V) in spiked samples were between 81 19 and I I I 15% when 120 s of sample loading were used. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple method with a fast sample preparation procedure for total and inorganic mercury determinations in blood samples is proposed based on flow injection cold vapor inductively coupled plasma mass spectrometry (FI-CVICP-MS). Aliquots of whole blood (500 mL) are diluted 1 + 1 v/v with 10.0% v/v tetramethylammonium hydroxide (TMAH) solution, incubated for 3 h at room temperature and then further diluted 1 + 4 v/v with 2.0% v/v HCl. The inorganic Hg was released by online addition of L-cysteine and then reduced to elemental Hg by SnCl(2). On the other hand, total mercury was determined by on-line addition of KMnO(4) and then reduced to elemental Hg by NaBH(4). Samples were calibrated against matrix-matching. The method detection limit was found to be 0.80 mu g L(-1) and 0.08 mu g L(-1) for inorganic and total mercury, respectively. Sample throughput is 20 samples h(-1). The method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). For additional validation purposes, human whole blood samples were analyzed by the proposed method and by an established CV AAS method, with no statistical difference between the two techniques at 95% confidence level on applying the t-test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objectivo do presente trabalho foi desenvolver, implementar e validar métodos de determinação de teor de cálcio (Ca), magnésio (Mg), sódio (Na), potássio (K) e fósforo (P) em biodiesel, por ICP-OES. Este método permitiu efectuar o controlo de qualidade do biodiesel, com a vantagem de proporcionar uma análise multi-elementar, reflectindo-se numa diminuição do tempo de análise. Uma vez que o biodiesel é uma das principais fontes de energia renovável e alternativa ao diesel convencional, este tipo de análises revela-se extremamente útil para a sua caracterização. De acordo com a análise quantitativa e qualitativa e após a validação dos respectivos ensaios, apresentam-se, na Tabela 1 as condições optimizadas para cada elemento em estudo. As condições de trabalho do ICP-OES foram escolhidas tendo em conta as características do elemento em estudo, o tipo de equipamento utilizado para a sua análise, e de modo a obter a melhor razão sinal/intensidade de fundo. Para a validação dos ensaios foram efectuados ensaios de recuperação, determinados limites de detecção e quantificação, ensaios de repetibilidade e reprodutibilidade, e verificação das curvas de calibração. Na tabela 2 apresentam-se os comprimentos de onda escolhidos (livres de interferências) e respectivos limites de detecção e quantificação dos elementos analisados por ICP-OES, na posição radial e radial atenuado.