951 resultados para indirect purchasing
Resumo:
Report on a review of selected general and application controls over the University of Northern Iowa Accounts Payable/Purchasing System for the period of June 10, 2009 through August 20, 2009
Resumo:
This research seeks to fill some of the gaps in understanding the local, regional, and statewide economic consequences of the disasters of 2008. This report evaluates sets of population, unemployment, employment, business firms, and trade patterns over time in an attempt to discern the household consumption and business productivity disruptions caused by the weather disasters of 2008.
Resumo:
A patent processus vaginalis peritonei (PPV) presents typically as an indirect hernia with an intact inguinal canal floor during childhood. Little is known however about PPV in adults and its best treatment. A cohort study included all consecutive patients admitted for ambulatory open hernia repair. In patients with a PPV, demographics, hernia characteristics, and outcome were prospectively assessed. Annulorrhaphy was the treatment of choice in patients with an internal inguinal ring diameter of < 30 mm. Between 1998 and 2006, 92 PPVs (two bilateral) were diagnosed in 676 open hernia repairs (incidence of 14%). Eighty nine of the 90 patients were males, the median age was 34 years (range: 17-85). A PPV was right-sided in 67% and partially obliterated in 66%. Forty-one patients had an annulorrhaphy and 51 patients had a tension-free mesh repair. The median operation time was significantly shorter in the annulorrhaphy group (38 vs. 48 min, P <.0001). In a median follow-up period of 56 months (27-128), both groups did not differ concerning recurrence (1/41 vs. 2/51), chronic pain (3/41 vs. 4/51), and hypoesthesia (5/41 vs. 9/51). There was however a clear trend to less neuropathic symptoms in favor of annulorrhaphy (0/41 vs. 5/51, P < 0.066). PPV occurs in 14% of adults undergoing hernia repair. In selected patients, annulorrhaphy takes less time and is associated with equally low recurrence but less potential for neuropathic symptoms.
Resumo:
Background: Cytomegalovirus (CMV) disease remains an important cause of morbidity after kidney transplantation and has been associated with acute rejection, graft loss and other indirect effects. A 3-month course of VGC prophylaxis reduces the incidence of CMV disease. However, little is known about the indirect effects of lateonset CMV disease after VGC prophylaxis. Objective: To evaluate the impact and indirect consequences of late-onset CMV disease after VGC prophylaxis in kidney transplant recipients. Methods: Retrospective analysis of 61 consecutive adult kidney transplant recipient with positive CMV serology (donor or recipient) who received VGC prophylaxis for 3 months and completed a follow-up of at least 2 years post-transplantation. Patients who developed CMV disease within 1 year after transplantation were compared to CMV disease-free patients for renal function (plasma creatinine values) at 1, 6, 12 and 24 months and for the incidence of graft loss, acute rejection, diabetes, cancer and opportunistic infections. Results: 8/61 (13%) patients developed CMV disease at a median of 131 days after transplantation (range: 98-220). The CMV incidence in D+/R- high risk patients was 6/18 (33%), while it was 2/43 (5%) in intermediate-risk patients (p < 0.01). All 8 patients were treated by oral valganciclovir (median 39 days; range: 19-119) with a complete resolution of CMV disease. As shown in the figure, there was no difference in creatinine values between the two groups at any time during follow-up. There was no graft loss, and the incidence of acute rejection, cancer and opportunistic infections did not differ between the two groups. The incidence of post-transplant diabetes was higher (38% vs 15%) in patients with CMV disease, but this difference was not significant (p = 0.4). Conclusions: An incidence of 13% of late-onset CMV disease was observed despite 3 months VGC prophylaxis. However, no indirect consequences were found. Moreover, therapy of CMV disease by oral VGC was effective and safe. Larger trials are needed to study whether late-onset CMV disease is associated with indirect consequences, as described with early-onset CMV.
Resumo:
Assessing the total energy expenditure (TEE) and the levels of physical activity in free-living conditions with non-invasive techniques remains a challenge. The purpose of the present study was to investigate the accuracy of a new uniaxial accelerometer for assessing TEE and physical-activity-related energy expenditure (PAEE) over a 24 h period in a respiratory chamber, and to establish activity levels based on the accelerometry ranges corresponding to the operationally defined metabolic equivalent (MET) categories. In study 1, measurement of the 24 h energy expenditure of seventy-nine Japanese subjects (40 (SD 12) years old) was performed in a large respiratory chamber. During the measurements, the subjects wore a uniaxial accelerometer (Lifecorder; Suzuken Co. Ltd, Nagoya, Japan) on their belt. Two moderate walking exercises of 30 min each were performed on a horizontal treadmill. In study 2, ten male subjects walked at six different speeds and ran at three different speeds on a treadmill for 4 min, with the same accelerometer. O2 consumption was measured during the last minute of each stage and was expressed in MET. The measured TEE was 8447 (SD 1337) kJ/d. The accelerometer significantly underestimated TEE and PAEE (91.9 (SD 5.4) and 92.7 (SD 17.8) % chamber value respectively); however, there was a significant correlation between the two values (r 0.928 and 0.564 respectively; P<0.001). There was a strong correlation between the activity levels and the measured MET while walking (r(2) 0.93; P<0.001). Although TEE and PAEE were systematically underestimated during the 24 h period, the accelerometer assessed energy expenditure well during both the exercise period and the non-structured activities. Individual calibration factors may help to improve the accuracy of TEE estimation, but the average calibration factor for the group is probably sufficient for epidemiological research. This method is also important for assessing the diurnal profile of physical activity.
Resumo:
Dr. Gilbert Y. Baladi of Michigan State University has developed a new device intended for reliable determination of asphalt concrete mechanical properties such as Poisson's ratio, resilient modulus, and indirect tensile strength. The device is the result of an effort to improve upon procedures and equipment currently available for evaluation of mechanical properties. A duplicate of this device was fabricated in the Iowa Department of Transportation, Materials Lab Machine Shop in 1989. This report details the results of an evaluation of the effectiveness of the device in testing Marshall specimens for indirect tensile strength as compared to results obtained with standard equipment described in AASHTO T-283. Conclusions of the report are: l. Results obtained with the Baladi device average 6 to 8 percent higher than those obtained with the standard device. 2. The standard device exhibited a slightly greater degree of precision than did the Baladi device. 3. The Baladi device is easier and quicker to use than the standard apparatus. 4. It may be possible to estimate indirect tensile strength from the stability/flow ratio by dividing by factors of 1.8 and 1.5 for 50 blow and 75 blow mixes respectively.
Resumo:
We consider the problem of estimating the mean hospital cost of stays of a class of patients (e.g., a diagnosis-related group) as a function of patient characteristics. The statistical analysis is complicated by the asymmetry of the cost distribution, the possibility of censoring on the cost variable, and the occurrence of outliers. These problems have often been treated separately in the literature, and a method offering a joint solution to all of them is still missing. Indirect procedures have been proposed, combining an estimate of the duration distribution with an estimate of the conditional cost for a given duration. We propose a parametric version of this approach, allowing for asymmetry and censoring in the cost distribution and providing a mean cost estimator that is robust in the presence of extreme values. In addition, the new method takes covariate information into account.
Resumo:
A transportable, whole body indirect calorimeter, designed for use in the tropics, is described. The calorimeter was built to study energy expenditure of people having chronically or acutely low levels of food intake, and it will help to determine energy adaptations made by individuals with restricted food intake. The calorimeter comprises two units: a 27 m3 ventilated chamber connected to an office housing control and monitoring equipment. The system also allows the experimenter to assess the rate of energy expenditure by means of a ventilated hood or a baby respiration chamber. The incoming air flow rate is variable and is typically set at approximately 30 l/min. Carbon dioxide production (VCO2) and oxygen consumption (VO2) are continuously monitored by means of differential gas analysers via a computerized data acquisition unit. Gas production/consumption rates are measured with a delay of 80 s, the complete response to step changes in VCO2 or VO2 consumption being calculated over 15 min using the rate of change terms in the gas exchange equations. The total electrical power required for the whole system is 12 kW. The calorimeter has been functioning for nearly 4 years in a rural village of The Gambia during which ambient temperatures have ranged from 16 to 44 degrees C and dewpoints from -8 to 24 degrees C. The performance and accuracy of the calorimeter were tested using 20 per cent CO2 in N2 infusion and butane burning. Agreement between the theoretical and the measured values was found to be 99 per cent for VO2 and 100 per cent for VCO2 with a precision for both gases of +/- 10 ml/min over a 1-h period.
Resumo:
The objective of this work was to estimate the genetic parameters, genotypic and phenotypic correlations, and direct and indirect genetic gains among and within rubber tree (Hevea brasiliensis) progenies. The experiment was set up at the Municipality of Jaú, SP, Brazil. A randomized complete block design was used, with 22 treatments (progenies), 6 replicates, and 10 plants per plot at a spacing of 3x3 m. Three‑year‑old progenies were assessed for girth, rubber yield, and bark thickness by direct and indirect gains and genotypic correlations. The number of latex vessel rings showed the best correlations, correlating positively and significantly with girth and bark thickness. Selection gains among progenies were greater than within progeny for all the variables analyzed. Total gains obtained were high, especially for girth increase and rubber yield, which were 93.38 and 105.95%, respectively. Young progeny selection can maximize the expected genetic gains, reducing the rubber tree selection cycle.
Resumo:
Indirect reciprocity is a form of reciprocity where help is given to individuals based on their reputation. In indirect reciprocity, bad acts (such as not helping) reduce an individual's reputation while good acts (such as helping) increase an individual's reputation. Studies of indirect reciprocity assume that good acts and bad acts are weighted equally when assessing the reputation of an individual. As different information can be processed in different ways, this is not likely to be the case, and it is possible that an individual could bias an actor's reputation by putting more weight to acts of defection (not helping) than acts of co-operation (helping) or vice versa. We term this difference 'judgement bias', and build an individual-based model of image scoring to investigate the conditions under which it may evolve. We find that, if the benefits of co-operation are small, judgement bias is weighted towards acts perceived to be bad; if the benefits are high, the reverse is true. Our result is consistent under both scoring and standing strategies, and we find that allowing judgement bias to evolve increases the level of co-operation in the population.
Resumo:
PURPOSE: To use measurement by cycling power meters (Pmes) to evaluate the accuracy of commonly used models for estimating uphill cycling power (Pest). Experiments were designed to explore the influence of wind speed and steepness of climb on accuracy of Pest. The authors hypothesized that the random error in Pest would be largely influenced by the windy conditions, the bias would be diminished in steeper climbs, and windy conditions would induce larger bias in Pest. METHODS: Sixteen well-trained cyclists performed 15 uphill-cycling trials (range: length 1.3-6.3 km, slope 4.4-10.7%) in a random order. Trials included different riding position in a group (lead or follow) and different wind speeds. Pmes was quantified using a power meter, and Pest was calculated with a methodology used by journalists reporting on the Tour de France. RESULTS: Overall, the difference between Pmes and Pest was -0.95% (95%CI: -10.4%, +8.5%) for all trials and 0.24% (-6.1%, +6.6%) in conditions without wind (<2 m/s). The relationship between percent slope and the error between Pest and Pmes were considered trivial. CONCLUSIONS: Aerodynamic drag (affected by wind velocity and orientation, frontal area, drafting, and speed) is the most confounding factor. The mean estimated values are close to the power-output values measured by power meters, but the random error is between ±6% and ±10%. Moreover, at the power outputs (>400 W) produced by professional riders, this error is likely to be higher. This observation calls into question the validity of releasing individual values without reporting the range of random errors.