982 resultados para fixed partial denture
Resumo:
Background: The aim of the present study was to evaluate clinical and radiographic changes that occur around dental implants inserted in different levels in relation to crestal bone under different restoration protocols.Methods: Thirty-six implants were inserted in the edentulous mandible of six mongrel dogs. Each implant was assigned to an experimental group according to the distance from the top of the implant to the crestal bone: Bone Level (at crestal bone level), Minus 1 (1 mm below crestal bone), or Minus 2 (2 mm below crestal bone). Each hemimandible was submitted to a restoration protocol: conventional (prosthesis was installed 120 days after implant placement, including 30 days with healing cap) or immediate (prosthesis was installed 24 hours after implant placement). Fixed partial prostheses were installed bilaterally in the same day. After 90 days, clinical and radiographic parameters were evaluated.Results: As long as the implants were inserted in more apical positions, the first bone-to-implant contact (fBIC) was positioned more apically (P<0.05). However, the apical positioning of the implants did not influence the ridge loss or the position of the soft tissue margin (PSTM) (P>0.05). In addition, in immediately restored sites, the PSTM was located significantly more coronally than that in conventionally restored sites (P=0.02).Conclusions: Despite the more apical positioning of the fBIC, the height of the peri-implant soft tissues and ridge was not jeopardized. Moreover, the immediate restoration protocol was beneficial to the maintenance of the PSTM. Further studies are suggested to evaluate the significance of these results in longer healing periods.
Resumo:
Objective: This investigation evaluated the knowledge of dental caries and periodontal disease among removable partial denture (RPD) wearers.Method: A total of 127 partially dentate patients participated in this observational study. A structured questionnaire, which included eight questions referring to knowledge about aetiology and prevention of dental caries and periodontal disease, was developed in the local language (Portuguese) and used to collect the data of all the partial denture wearers. A descriptive analysis of data was performed by means of drafting tables.Results: The results demonstrated that 68.5% of patients interviewed had previously received information about oral health care. With regard to bacterial plaque, it was observed that only 34.6% reported having knowledge of this. Whereas, in relation to caries, 76.4% of the interviewees replied that they knew the meaning of this. Nevertheless, 28.3% referred to caries as a whole in the teeth, 16.5% as bad teeth and 9.4% bacteria/creatures on the teeth. Only 17.3% of the partially edentulous patients evaluated were shown to know what disease of the gingiva was.Conclusion: By means of the methodology applied, it could be concluded that the patients who wore RPDs presented deficient knowledge with regard to the prevention, aetiology and development of dental caries and periodontal disease.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Statement of problem. Highly polished enamel surfaces arc recommended for axial tooth surfaces that will serve as guiding planes and be contacted by component parts of a removable partial denture. There is little evidence to support the assumption that this tooth modification will provide accurate adaptation of the framework and prevent build-up of plaque.Purpose. The aim of this investigation was to evaluate the surface roughness of the tooth enamel, prepared to serve as guiding planes, with different polishing systems.Material and methods. Four different methods (designated A, B, C, and D) for finishing and polishing the prepared enamel surfaces of 20 freshly extracted third molar teeth were studied. Each method involved 3, 4, or 5 different steps. The roughness of each specimen was measured at the start of each method before recontouring, after recontouring, and after each step of the 4 finishing and polishing procedures. The 4 experimental finishing methods were applied after recontouring the axial surfaces (buccal, lingual, and proxinial) of each tooth. Thus the 20 teeth (60 surfaces) were finished and polished by use of 1 of the experimental methods. Surface roughness was measured with a profilometer (mum); the readings of the unpolished enamel Surfaces were recorded as control measurements. Results were statistically analyzed with one-way analysis of variance followed by Tukey's test at the 95% level of confidence.Results. The highest roughness mean values (14.41 mum to 16.44 mum) were found when the diamond bur was used at a high speed for tooth preparation. A significant decrease in roughness values was observed with the diamond bur at a low speed (P<.05). Analysis of the roughness values revealed that all polishing methods produced surface roughness similar to that of the corresponding control teeth.Conclusion. Within the limitations of this study, all finishing procedures tested effectively promoted an enamel surface similar to the original unpolished enamel.
Resumo:
The purpose of this study was to evaluate the periodontal conditions of removable partial denture (RPD) wearers, comparing direct and indirect abutment teeth, and the teeth not involved in the denture design before denture placement and 1 year later. Fifty patients (32 women and 18 men), average age 45, were assessed by the same examiner at the moment of denture insertion and 3, 6, 9 and 12 months later. The following items were verified in each assessment: probing depth (PD), plaque index (PI) and gingival index (GI). PD and PI data were evaluated by ANOVA test for linear trend followed by Tukey-Kramer post-test, while GI data were analysed by Friedman's test. Results showed that the teeth not involved in the denture design were the least affected for all variables studied. It was also verified that PD and GI mean values increased from the initial assessment to 1 year of RPD wearing in every group, but that only PI showed a significant increase. This study indicated that direct and indirect retainer elements tend to undergo more damaging periodontal effects associated with RPD wearing when compared with non-abutment elements. Plaque index values were significantly higher after 1 year of denture use.
Resumo:
The authors looked for the verification of the fatigue of retentive clasps utilized on the removable partial denture. According to this, it was idealized and built on assay machine, that through movements, simulate the insertion and removal of the clasp for a pattern tooth, manufactured on cobalt-chromium which has all the preparation normally utilized to the correct confection of this type of prosthesis. It was utilized three different commercial alloys based on cobalt-chromium: L1-Biosil; L2-Steldent; L3-Duracron. It was utilized the T clasp of Roach, with was tested upon three different proportions among width and thickness: E1-1.7;E2-2.0 and E3-2.3 and was casted through two casting techniques: F1-oxygen-gas and F2-oxygen-acetylene. The clasps were tested on the machine, which allowed the reading of the number of insertion and removal cycles made until fatigue appeared. The obtained results were submitted to the statistic analysis and the authors concluded that: a) L3 (Duracrom) obtained the best results followed by L1 (Biosil) and finally L3 (Steldent); b) among the analyzed thickness, the best results were obtained by E3, followed by E2 and after this E1; c) form the casting techniques, F2 gave us the best results.
Resumo:
Aim: The aim of the study was to assess the accuracy of a new intraoral paralleling device for creating proximal guiding planes for removable partial dental prostheses. Methods and Materials: Thirty gypsum casts were divided into two groups in which the proximal surfaces of selected teeth were prepared using either a surveying device (Group 1) or the new ParalAB paralleling device (Group 2). In each cast guiding planes were prepared on the distal surface of the maxillary left canine (A), on the mesial and distal surfaces of the maxillary left second molar (B and C), and on the distal surface of the maxillary right canine (D). Each prepared surface formed an angle related to the occlusal plane that was measured five times and averaged by one operator using a tridimensional coordinate machine. Results: The mean guiding plane angles (± standard deviation) for the prepared surfaces were A=91.82° (±0.48°, B=90.47° (±0.47°, C=90.21° (±0.76°, and D=90.50° (±0.73°) for the dental surveyor (Group 1) and A=92.18° (±0.87°), B=90.90° (±0.85°), C=90.07° (±0.92°), and D=90.66° (±0.76°) for the ParalAB paralleling device (Group 2). A two-way ANOVA, Tukey's, and Levène's tests (at p<0.05) revealed statistically significant differences among surfaces prepared by both groups and that one surface Conclusions: The ParalAB device was able to prepare parallel surfaces and despite significant difference between groups, the ParalAB presented a small deviation from absolute parallelism and can be considered a valid method to transfer guide plans in the fabrication of removable partial dentures. Clinical Significance: The preparation of suitable guiding planes on abutment teeth during the fabrication of removable partial dentures is dependent on the ability of the operator and requires considerable chair time. When multiple teeth are involved, achieving parallelism between abutment surfaces can be technically challenging, especially in posterior regions of the mouth. The ParalAB prototype intraoral paralleling device can aid the clinician during the preparation of accurate guiding planes with a minimum degree of occlusal divergence. © 2010 Seer Publishing LLC.
Resumo:
Nowadays, aesthetics is very appreciated in the social context and a attractive smile is the object of desire in most of patients requiring prosthesis treatment. In case of removable prosthesis, total or partial, this feature is more significant since some or all teeth may be absents. Implants leading to a significant improvement in relation to function and comfort of removable prosthesis users, but the aesthetics of these prostheses had little attention in the current scientific literature. Thus, the aim of present article was to make a review of the literature on the aesthetic features related to rehabilitation with removable prostheses. In present study we found as significant factors for the aesthetics in removable partial and total prostheses: Selection of artificial teeth and their arrangement, characterization of acrylic resin basis and also the types and location of retainers for the removable partial prostheses. We conclude that the involvement and the aesthetic knowledge during the appropriate planning of this process is responsibility of the professional.
Resumo:
Objective: The objective of this study was to describe the oral health of elderly people diagnosed with Alzheimer's disease (AD). Study Design: Thirty elderly subjects with AD (mild, moderate, and severe) and 30 without AD (controls) were included in the study. Volunteer-reported oral health data were collected using the General Oral Health Assessment Index (GOHAI). Demographic and oral characteristics were assessed, including the number of natural teeth; number of decayed, missing, and filled teeth (DMTF); oral health index (OHI); removable prosthesis conditions; and oral pathologies. Results: GOHAI values were similar for both groups. Compared with the controls, the subjects with AD had a higher age, DMTF, OHI, and number of oral pathologies and a lower educational level and number of natural teeth. Conclusions: Elderly subjects with AD had poorer oral health than those without the disease. Despite the positive self-perception of their oral health, the oral health of subjects with AD tended to decline as their disease progressed. © 2012 Elsevier Inc.
Resumo:
Objective. Considering that patients' satisfaction is one of the most important goals in conducting removable dental prosthesis (RDP) therapy and the fact that there are many factors which influence this parameter, the present study aims to evaluate the expectation before and satisfaction after therapy with RDP in patients who seek such therapy. As a secondary objective, other variables that may be associated with patient satisfaction are also evaluated, such as gender, age, Kennedy's classification of the arch supporting the RDP, the number of RDP adjustments after delivery and patients' evaluation of the dentists' conduct. Materials and methods. A sample of 44 patients who received RDP therapy were assigned visual analog scale scores for their expectation before and satisfaction after therapy regarding chewing, aesthetics, comfort and phonetics. They also completed a questionnaire concerning the dentists' conduct. Results. There was no statistically significant difference among scores concerning different genders, age, number of post-delivery settings and arch involved in the RDP. Regarding patients' evaluation of the dentists' conduct, there was a predominance of positive evaluations, but only different answers to the statement (i.e. 'The dentist I saw thoroughly explained the recommended treatment before it commenced') present statistically significant different scores for chewing (p = 0.040) and phonetics (p = 0.046). Conclusions. The average visual analog scale scores were high for both expectation prior to treatment and satisfaction after treatment; however, the scores for expectations were higher than those for satisfaction. © 2013 Informa Healthcare.
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Pós-graduação em Reabilitação Oral - FOAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia - FOA