953 resultados para false positive


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective To demonstrate the potential value of screening for Down's Syndrome using highly correlated repeated measures of serum markers taken in the first and second trimesters of pregnancy. Design A Monte Carlo simulation study. Population Detection rates and false positive rates relating to the maternal age distribution of England and Wales for the period 1996 to 1998 were obtained using marker distributions from the SURUSS study. Results Screening using first trimester nuchal translucency and repeated measures of uE3 and PAPP-A in the first and second trimester has an estimated false positive rate of 0.3% for an 85% detection rate. This should be compared with the integrated test with an estimated false positive rate of 1.2% for the same detection rate. Conclusionsâ?? The performance of repeated measures screening tests, and their acceptability to women, should be assessed in further prospective studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective Within the framework of a health technology assessment and using an economic model, to determine the most clinically and cost effective policy of scanning and screening for fetal abnormalities in early pregnancy. Design A discrete event simulation model of 50,000 singleton pregnancies. Setting Maternity services in Scotland. Population Women during the first 24 weeks of their pregnancy. Methods The mathematical model was populated with data on uptake of screening, prevalence, detection and false positive rates for eight fetal abnormalities and with costs for ultrasound scanning and serum screening. Inclusion of abnormalities was based on the relative prevalence and clinical importance of conditions and the availability of data. Six strategies for the identification of abnormalities prenatally including combinations of first and second trimester ultrasound scanning and first and second trimester screening for chromosomal abnormalities were compared. Main outcome measures The number of abnormalities detected and missed, the number of iatrogenic losses resulting from invasive tests, the total cost of strategies and the cost per abnormality detected were compared between strategies. Results First trimester screening for chromosomal abnormalities costs more than second trimester screening but results in fewer iatrogenic losses. Strategies which include a second trimester ultrasound scan result in more abnormalities being detected and have lower costs per anomaly detected. Conclusions The preferred strategy includes both first and second trimester ultrasound scans and a first trimester screening test for chromosomal abnormalities. It has been recommended that this policy is offered to all women in Scotland.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective To present a first and second trimester Down syndrome screening strategy, whereby second-trimester marker determination is contingent on the first-trimester results. Unlike non-disclosure sequential screening (the Integrated test), which requires all women to have markers in both trimesters, this allows a large proportion of the women to complete screening in the first trimester. Methods Two first-trimester risk cut-offs defined three types of results: positive and referred for early diagnosis; negative with screening complete; and intermediate, needing second-trimester markers. Multivariate Gaussian modelling with Monte Carlo simulation was used to estimate the false-positive rate for a fixed 85% detection rate. The false-positive rate was evaluated for various early detection rates and early test completion rates. Model parameters were taken from the SURUSS trial. Results Completion of screening in the first trimester for 75% of women resulted in a 30% early detection rate and a 55% second trimester detected rate (net 85%) with a false-positive rate only 0.1% above that achievable by the Integrated test. The screen-positive rate was 0.1% in the first trimester and 4.7% for those continuing to be tested in the second trimester. If the early detection rate were to be increased to 45% or the early completion rate were to be increased to 80%, there would be a further 0.1% increase in the false-positive rate. Conclusion Contingent screening can achieve results comparable with the Integrated test but with earlier completion of screening for most women. Both strategies need to be evaluated in large-scale prospective studies particularly in relation to psychological impact and practicability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective To demonstrate the potential value of three-stage sequential screening for Down syndrome. Methods Protocols were considered in which maternal serum pregnancy associated plasma protein-A (PAPP-A) and free -human chorionic gonadotropin (hCG) measurements were taken on all women in the first trimester. Those women with very low Down syndrome risks were screened negative at that stage and nuchal translucency (NT) was measured on the remainder and the risk reassessed. Those with very low risk were then screened negative and those with very high risk were offered early diagnostic testing. Those with intermediate risks received second-trimester maternal serum -fetoprotein, free -hCG, unconjugated estriol and inhibin-A. Risk was then reassessed and those with high risk were offered diagnosis. Detection rates and false-positive rates were estimated by multivariate Gaussian modelling using Monte-Carlo simulation. Results The modelling suggests that, with full adherence to a three-stage policy, overall detection rates of nearly 90% and false-positive rates below 2.0% can be achieved. Approximately two-thirds of pregnancies are screened on the basis of first-trimester biochemistry alone, five out of six women complete their screening in the first trimester, and the first-trimester detection rate is over 60%. Conclusion Three-stage contingent sequential screening is potentially highly effective for Down syndrome screening. The acceptability of this protocol and its performance in practice, should be tested in prospective studies. Copyright © 2006 John Wiley & Sons, Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, a novel video-based multimodal biometric verification scheme using the subspace-based low-level feature fusion of face and speech is developed for specific speaker recognition for perceptual human--computer interaction (HCI). In the proposed scheme, human face is tracked and face pose is estimated to weight the detected facelike regions in successive frames, where ill-posed faces and false-positive detections are assigned with lower credit to enhance the accuracy. In the audio modality, mel-frequency cepstral coefficients are extracted for voice-based biometric verification. In the fusion step, features from both modalities are projected into nonlinear Laplacian Eigenmap subspace for multimodal speaker recognition and combined at low level. The proposed approach is tested on the video database of ten human subjects, and the results show that the proposed scheme can attain better accuracy in comparison with the conventional multimodal fusion using latent semantic analysis as well as the single-modality verifications. The experiment on MATLAB shows the potential of the proposed scheme to attain the real-time performance for perceptual HCI applications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Porcine urine enzyme immunoassays for sulfamethazine and sulfadiazine have previously been employed as screening tests to predict the concentrations of the drugs in the corresponding tissues (kidneys), If a urine was found positive (> 800 ng ml(-1)) the corresponding kidney was then analysed by an enzyme immunoassay and, if found positive, a confirmatory analysis by HPLC was performed. Urine was chosen as the screening matrix since sulfonamides are mainly eliminated through this body fluid, However, after obtaining a number of false positive predictions, an investigation was carried out to assess the possibility of using an alternative body fluid which would act as a superior indicator of the presence of sulfonamides in porcine kidney, An initial study indicated that serum, plasma and bile could all be used as screening matrices. From these, bile was chosen as the preferred sample matrix and an extensive study followed to compare the efficiencies of sulfonamide positive bile and urine at predicting sulphonamide positive kidneys, Bile was found to be 17 times more efficient than urine at predicting a sulfamethazine positive kidney and 11 times more efficient at predicting a sulfadiazine positive kidney, With this enhanced performance of the initial screening test, the need for the costly and time consuming kidney enzyme immunoassay, prior to HPLC analysis, was eliminated

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background

Biomedical researchers are now often faced with situations where it is necessary to test a large number of hypotheses simultaneously, eg, in comparative gene expression studies using high-throughput microarray technology. To properly control false positive errors the FDR (false discovery rate) approach has become widely used in multiple testing. The accurate estimation of FDR requires the proportion of true null hypotheses being accurately estimated. To date many methods for estimating this quantity have been proposed. Typically when a new method is introduced, some simulations are carried out to show the improved accuracy of the new method. However, the simulations are often very limited to covering only a few points in the parameter space.

Results

Here I have carried out extensive in silico experiments to compare some commonly used methods for estimating the proportion of true null hypotheses. The coverage of these simulations is unprecedented thorough over the parameter space compared to typical simulation studies in the literature. Thus this work enables us to draw conclusions globally as to the performance of these different methods. It was found that a very simple method gives the most accurate estimation in a dominantly large area of the parameter space. Given its simplicity and its overall superior accuracy I recommend its use as the first choice for estimating the proportion of true null hypotheses in multiple testing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Blood cultures have an important role in the diagnosis of serious infections, although contamination of blood cultures (i.e. false-positive blood cultures) is a common problem within the hospital setting. The objective of the present investigation was to determine the impact of the false-positive blood culture results on the following outcomes: length of stay, hotel costs, antimicrobial costs, and costs of laboratory and radiological investigation. A retrospective case-control study design was used in which 142 false-positive blood culture cases were matched with suitable controls (patients for whom cultures were reported as true negatives). The matching criteria included age, comorbidity score and month of admission to the hospital. The research covered a 13-month period (July 2007 to July 2008). The findings indicated that differences in means, between cases and controls, for the length of hospital stay and the total costs were 5.4 days [95% CI (confidence interval): 2.8-8.1 days; P

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective To develop a provisional definition for the evaluation of response to therapy in juvenile dermatomyositis (DM) based on the Paediatric Rheumatology International Trials Organisation juvenile DM core set of variables. Methods Thirty-seven experienced pediatric rheumatologists from 27 countries achieved consensus on 128 difficult patient profiles as clinically improved or not improved using a stepwise approach (patient's rating, statistical analysis, definition selection). Using the physicians' consensus ratings as the “gold standard measure,” chi-square, sensitivity, specificity, false-positive and-negative rates, area under the receiver operating characteristic curve, and kappa agreement for candidate definitions of improvement were calculated. Definitions with kappa values >0.8 were multiplied by the face validity score to select the top definitions. Results The top definition of improvement was at least 20% improvement from baseline in 3 of 6 core set variables with no more than 1 of the remaining worsening by more than 30%, which cannot be muscle strength. The second-highest scoring definition was at least 20% improvement from baseline in 3 of 6 core set variables with no more than 2 of the remaining worsening by more than 25%, which cannot be muscle strength (definition P1 selected by the International Myositis Assessment and Clinical Studies group). The third is similar to the second with the maximum amount of worsening set to 30%. This indicates convergent validity of the process. Conclusion We propose a provisional data-driven definition of improvement that reflects well the consensus rating of experienced clinicians, which incorporates clinically meaningful change in core set variables in a composite end point for the evaluation of global response to therapy in juvenile DM.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The efficacies of putative fasciolicides and vaccines against Fasciola hepatica are frequently monitored in clinical and field trials by determination of fluke egg output in host faeces and by worm counts in the host liver at autopsy. Less often used are parameters based on fluke size and histology, yet these can provide important indications of specific effects on the development of particular germ-line or somatic tissues, especially in relation to the timing and profligacy of egg production. In this study. F. hepatica metacercariae of two distinct isolates, the triclabendazole (TCBZ)-sensitive Cullompton isolate and the TCBZ-resistant Oberon isolate, were administered to rats as single-isolate or mixed-isolate infections. At autopsy 16 weeks later individual adult flukes were counted, measured and the reproductive organs were examined histologically. The degree of development of the testis tubules in each fluke was represented by a numerical score, based on the proportion of the histological section profiles occupied by testis tissue. The level of anti-F. hepatica antibody in the serum of each rat was determined by ELISA. It was found that Cullompton flukes were significantly larger than Oberon flukes, and that significantly more Cullompton metacercariae developed to adults than Oberon metacercariae. The Cullompton flukes showed histological evidence of aspermy and spermatogenic arrest, which was reflected in quantitatively reduced testicular development, as compared with the Oberon isolate. In Cullompton flukes, parthenogenetic egg development is implied. The size of Cullompton and Oberon flukes was significantly related to the number of adult flukes recovered, to the number of metacercariae administered, and to the percentage success of infection. The testis development score in both isolates was significantly related to the number of adult flukes recovered but not to the number of metacercariae administered, or to the percentage success of infection. Fluke size was positively related to testis score for both isolates, and a significant negative relationship was found between percentage success of infection and metacercarial dose. The results are interpreted in terms of differing interactions between various numbers of young flukes and host immunity during invasion of and migration in the hepatic parenchyma, and of fluke intra-specific (possibly pheromonal) stimulatory effects in the final stages of development, within the host bile ducts. No significant relationships were found between host antibody levels and fluke size or testis score. False positive serological reactions were found in some rats that had been infected, but found to harbour no flukes at autopsy. Clearly the act of eliminating the flukes involved generation of an immune response. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Furazolidone, a nitrofuran antibiotic, is banned from use in food animal production within the European Union. Increasingly, compliance with this ban is monitored by use of analytical methods to detect a stable tissue-bound metabolite, 3-amino-2-oxazolidinone (AOZ). Widespread use of furazolidone in poultry and prawns imported into Europe highlighted the urgent need for development of nitrofuran immunoassay screening tests. The first enzyme-linked immunoabsorbant assay for detection of AOZ residues in prawns (shrimps) is now described. Prawn samples were derivatized with o-nitrobenzaldehyde, extracted into ethyl acetate, washed with hexane and applied to a competitive enzyme immunoassay based on a rabbit polyclonal antiserum. Assay limit of detection (LOD) (mean+3 s) calculated from the analysis of 20 known negative cold and warm water prawn samples was 0.1 mug kg(-1). Intra- and interassay relative standard deviations were determined as 18.8 and 38.2%, respectively, using a negative prawn fortified at 0.7 mug kg(-1). The detection capability (CCbeta), defined as the concentration of AOZ at which 20 different fortified samples yielded results above the LOD, was achieved at fortification between 0.4 and 0.7 mug kg(-1). Incurred prawn samples (n=8) confirmed by liquid chromatography coupled with tandem mass spectrometry detection to contain AOZ concentrations between 0.4 and 12.7 mug kg(-1) were all screened positive by this enzyme-linked immunoabsorbant assay. Further data are presented and discussed with regard to calculating assay LOD based on accepting a 5% false-positive rate with representative negative prawn samples. Such an acceptance improves the sensitivity of an ELISA and in this case permitted an LOD of 0.05 mug kg(-1) and a CCbeta of below 0.4 mug kg(-1).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Zeranol, an oestrogenic growth promoter in food animals, is banned within the European Union (EU). However, commercially available immunoassay kits for zeranol cross-react with toxins formed by naturally occurring Fusarium spp. fungi, leading to false-positive screening results. This paper describes the validation of a specificity enhanced, rapid dry reagent time-resolved fluoroimmunoassay (TR-FIA) for zeranol (recovery 99%, limit of detection 1.3 ng ml(-1)) demonstrating that up to 150 ng ml(-1) of Fusarium spp. toxins in urine do not lead to false-positive results. This assay will assist EU Member States to implement Council Directive 961 23\EC, which requires states to monitor for potential abuses of zeranol. A similar TR-FIA for the Fusarium spp. toxin a-zearalenol, using the same sample extract, is also described (recovery 68%, limit of detection 5.6 ng ml(-1)). Only the addition of diluted sample extract is required to perform these dry-reagent TR-FIAs, the results being available within 1 h of extract application. The EU-funded project 'Natural Zeranol' (FAIR5-CT97-3443) will use these fluoroimmunoassays to screen bovine urine in four Member States to gather data on the seasonality of Fusarium spp. toxin contamination of urine and the incidence of zeranol screening test positives.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Avermectins are frequently used to control parasitic infestations in many animal species. Previous studies have shown the long-term persistence of unwanted residues of these drugs in animal tissues and fluids. An immunoassay screening test for the detection acid quantification of ivermectin residues in bovine milk has been developed. After an extensive extraction procedure, milk samples were applied to a competitive dissociation-enhanced lanthanide fluoroimmunoassay using a monoclonal antibody against an ivermectin-transferrin conjugate, The monoclonal antibody, raised in Balb C mice, showed cross-reactivity with eprinomectin (92%), abamectin (82%) and doramectin (16%). The limit of detection of the assay (mean + 3 SD), calculated from the analysis of 17 known negative samples, was calculated as 4.6 ng/mL. Intra- and inter-assay RSDs were determined as 11.6% and 15.8%, respectively, using a negative bovine milk sample fortified with 25 ng/mL ivermectin. Six Friesian milking cows were treated with ivermectin, three with a pour-on formulation of the drug and three with an injectable solution at the manufacturer's recommended dose rate. An initial mean peak in ivermectin residue concentration was detected at day 4 (mean level = 47.5 ng/mL) and day 5 post-treatment (mean level = 26.4 ng/mL) with the injectable form and pour-on treatment, respectively. A second peak in residue concentration was observed using the DELFIA(R) procedure 28 days post-treatment in both treatment groups (23.1 ng/mL injectable and 51.9 ng/mL pour-on). These second peaks were not confirmed by HPLC and must at this Lime be considered to be false-positive results. By day 35 after treatment the mean ivermectin residue concentration of both groups fell below the limit of detection of the assay. Copyright (C) 2000 John Wiley & Sons, Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The relationship between changes in retinal vessel morphology and the onset and progression of diseases such as diabetes, hypertension and retinopathy of prematurity (ROP) has been the subject of several large scale clinical studies. However, the difficulty of quantifying changes in retinal vessels in a sufficiently fast, accurate and repeatable manner has restricted the application of the insights gleaned from these studies to clinical practice. This paper presents a novel algorithm for the efficient detection and measurement of retinal vessels, which is general enough that it can be applied to both low and high resolution fundus photographs and fluorescein angiograms upon the adjustment of only a few intuitive parameters. Firstly, we describe the simple vessel segmentation strategy, formulated in the language of wavelets, that is used for fast vessel detection. When validated using a publicly available database of retinal images, this segmentation achieves a true positive rate of 70.27%, false positive rate of 2.83%, and accuracy score of 0.9371. Vessel edges are then more precisely localised using image profiles computed perpendicularly across a spline fit of each detected vessel centreline, so that both local and global changes in vessel diameter can be readily quantified. Using a second image database, we show that the diameters output by our algorithm display good agreement with the manual measurements made by three independent observers. We conclude that the improved speed and generality offered by our algorithm are achieved without sacrificing accuracy. The algorithm is implemented in MATLAB along with a graphical user interface, and we have made the source code freely available. 

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An optimised indirect peroxidase-anti-peroxidase immunohistochemical technique was used to detect endogenous biotin in frozen tissue sections from biotin-supplemented and biotin-depleted pigs and chickens. A monoclonal anti-biotin antibody was used as primary antibody in this technique. Immunoreactive biotin was detected in many tissues of both species including liver, kidney, pancreas, adipose tissue, adrenal gland, testis, brain, choroid plexus, cardiac and skeletal muscle, epithelium of the respiratory and digestive systems, skin and lymphoid tissues. The specificity of immunostaining for biotin was confirmed by the finding of reduced staining intensities in tissues of biotin-depleted animals compared to those of biotin-supplemented animals. The results of this study suggest that biotin has metabolic functions in a wider range of tissues than previously known. They also indicate that endogenous tissue biotin should be considered as a source of false positive staining when immunohistochemical or histochemical techniques which use avidin or streptavidin reagents or anti-biotin antibodies as components of the detection system, are applied to tissue sections.