876 resultados para eye-foot-connection


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A child's natural gait pattern may be affected by the gait laboratory environment. Wearable devices using body-worn sensors have been developed for gait analysis. The purpose of this study was to validate and explore the use of foot-worn inertial sensors for the measurement of selected spatio-temporal parameters, based on the 3D foot trajectory, in independently walking children with cerebral palsy (CP). We performed a case control study with 14 children with CP aged 6-15 years old and 15 age-matched controls. Accuracy and precision of the foot-worn device were measured using an optical motion capture system as the reference system. Mean accuracy±precision for both groups was 3.4±4.6cm for stride length, 4.3±4.2cm/s for speed and 0.5±2.9° for strike angle. Longer stance and shorter swing phases with an increase in double support were observed in children with CP (p=0.001). Stride length, speed and peak angular velocity during swing were decreased in paretic limbs, with significant differences in strike and lift-off angles. Children with cerebral palsy showed significantly higher inter-stride variability (measured by their coefficient of variation) for speed, stride length, swing and stance. During turning trajectories speed and stride length decreased significantly (p<0.01) for both groups, whereas stance increased significantly (p<0.01) in CP children only. Foot-worn inertial sensors allowed us to analyze gait spatiotemporal data outside a laboratory environment with good accuracy and precision and congruent results with what is known of gait variations during linear walking in children with CP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study describes the validation of a new wearable system for assessment of 3D spatial parameters of gait. The new method is based on the detection of temporal parameters, coupled to optimized fusion and de-drifted integration of inertial signals. Composed of two wirelesses inertial modules attached on feet, the system provides stride length, stride velocity, foot clearance, and turning angle parameters at each gait cycle, based on the computation of 3D foot kinematics. Accuracy and precision of the proposed system were compared to an optical motion capture system as reference. Its repeatability across measurements (test-retest reliability) was also evaluated. Measurements were performed in 10 young (mean age 26.1±2.8 years) and 10 elderly volunteers (mean age 71.6±4.6 years) who were asked to perform U-shaped and 8-shaped walking trials, and then a 6-min walking test (6MWT). A total of 974 gait cycles were used to compare gait parameters with the reference system. Mean accuracy±precision was 1.5±6.8cm for stride length, 1.4±5.6cm/s for stride velocity, 1.9±2.0cm for foot clearance, and 1.6±6.1° for turning angle. Difference in gait performance was observed between young and elderly volunteers during the 6MWT particularly in foot clearance. The proposed method allows to analyze various aspects of gait, including turns, gait initiation and termination, or inter-cycle variability. The system is lightweight, easy to wear and use, and suitable for clinical application requiring objective evaluation of gait outside of the lab environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in different hospitals in Europe will help towards this direction. This study aims at analysing the first results of the measurement campaign performed in IR and IC procedures in 34 European hospitals. The highest doses were found for pacemakers, renal angioplasties and embolisations. Left finger and wrist seem to receive the highest extremity doses, while the highest eye lens doses are measured during embolisations. Finally, it was concluded that it is difficult to find a general correlation between kerma area product and extremity or eye lens doses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This background paper details the work undertaken by the Institute to explore the potential for international collaboration in order to contribute to public health development in Ireland. It makes specific reference to the European Commission's proposal for a new programme of community action in the field of public health for 2001-2006.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to investigate the influence of ankle osteoarthritis (AOA) treatments, i.e., ankle arthrodesis (AA) and total ankle replacement (TAR), on the kinematics of multi-segment foot and ankle complex during relatively long-distance gait. Forty-five subjects in four groups (AOA, AA, TAR, and control) were equipped with a wearable system consisting of inertial sensors installed on the tibia, calcaneus, and medial metatarsals. The subjects walked 50-m twice while the system measured the kinematic parameters of their multi-segment foot: the range of motion of joints between tibia, calcaneus, and medial metatarsals in three anatomical planes, and the peaks of angular velocity of these segments in the sagittal plane. These parameters were then compared among the four groups. It was observed that the range of motion and peak of angular velocities generally improved after TAR and were similar to the control subjects. However, unlike AOA and TAR, AA imposed impairments in the range of motion in the coronal plane for both the tibia-calcaneus and tibia-metatarsals joints. In general, the kinematic parameters showed significant correlation with established clinical scales (FFI and AOFAS), which shows their convergent validity. Based on the kinematic parameters of multi-segment foot during 50-m gait, this study showed significant improvements in foot mobility after TAR, but several significant impairments remained after AA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eye colour of Triatoma infestans is controlled at a single autosomal locus, with black-eye as the dominant gene and red-eye as the recessive. Inheritance of these characters follows a classical Mendelian system, enabling eye colour to be used as a marker for studies of mating frequency. We found no significant differences in oviposition rates and egg hatching rates irrespective of parental phenotypes. Different mating schedules between red-eye and black-eye parents showed that eye colour did not affect mating competence. Females mated with a single male or with different males together or in succession produced similar numbers of fertile eggs, with the eye colour of the offspring reflecting exposure to the different males. We conclude that although a single mating can provide sufficient sperm for the whole reproductive life of the female, multiple matings can result in balanced assortative sperm usage from the spermatheca.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A medida que avanza la tecnolog a, cada vez son m as comunes los libros digitales. Por eso, existen varias formas de mejorar la experiencia de lectura del usuario, como mostrar la de nici on de una palabra que resulte dif cil, o resaltar lo importante del texto cuando se pasa la vista por encima. En este proyecto, se ha investigado la base de esto con la ayuda de un Eye Tracker. Se ha implementado una clasi caci on en palabras f aciles y dif ciles dependiendo de c omo una persona lee, y una forma de saber si se est a leyendo el texto o pasando la vista por encima.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the course of two trips to Central America (June 1967 and JulyAugust 1976) I had the opportunity of collecting topotypic specimens of Planorbis nicaraguanus Morelet, 1849, anatomically defined in this paper, and of P. yzabalensis Crosse & Fischer, 1879, the identity of the latter with Drepanotrema anatinum (Orbigny, 1835) is confirmed. The following planorbid species were also found: Helisoma trivolvis (Say, 1817) in Nicaragua, Guatemala, Costa Rica and Belize; H. duryi (Wetherby, 1879) in Costa Rica; Biomphalaria helophila (Orbigny, 1835) in Guatemala, Belize, Nicaragua, Costa Rica and El Salvador; B. kuhniana (Clessin, 1883) in Panama; B. obstructa (Morelet,1849) in Guatemala, Belize and El Salvador; B. straminea (Dunker, 1848) in Costa Rica; B. subprona (Martens, 1899) in Guatemala; D. anatinum (Orbigny,1835) in Belize, Guatemala, Nicaragua and Costa Rica; D. depressissimum (Moricand,1839) in Nicaragua, Costa Rica and Panama; D. lucidum (Pfeiffer, 1839) in Guatemala, Belize and Nicaragua; D. surinamense (Clessin, 1884) in Costa Rica and Panama; and Gyraulus percarinatus sp. n. in Panama. The occurrence of B. kuhniana and D. surinamense is first recorded in Central America, and Gyraulus percarinatus is the first representative of the genus provenly occurring in the American continent south of the United States. The following synonymy is proposed: Planorbis declivis Tate, 1870 = Biomphalaria helophila (Orbigny, 1835); Planorbis isthmicus Pilsbry, 1920 = Biomphalaria kuhniana (Clessin, 1883); Planorbis cannarum Morelet, 1849 and Segmentina donbilli Tristram, 1861 = Biomphalaria obstructa (Morelet, 1849); and Planorbis yzabalensis Crosse & Fischer, 1879 = Drepanotrema anatinum (Orbigny, 1835), confirming Aguayo (1933).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While knowledge about standardization of skin protection against ultraviolet radiation (UVR) has progressed over the past few decades, there is no uniform and generally accepted standardized measurement for UV eye protection. The literature provides solid evidence that UV can induce considerable damage to structures of the eye. As well as damaging the eyelids and periorbital skin, chronic UV exposure may also affect the conjunctiva and lens. Clinically, this damage can manifest as skin cancer and premature skin ageing as well as the development of pterygia and premature cortical cataracts. Modern eye protection, used daily, offers the opportunity to prevent these adverse sequelae of lifelong UV exposure. A standardized, reliable and comprehensive label for consumers and professionals is currently lacking. In this review we (i) summarize the existing literature about UV radiation-induced damage to the eye and surrounding skin; (ii) review the recent technological advances in UV protection by means of lenses; (iii) review the definition of the Eye-Sun Protection Factor (E-SPF®), which describes the intrinsic UV protection properties of lenses and lens coating materials based on their capacity to absorb or reflect UV radiation; and (iv) propose a strategy for establishing the biological relevance of the E-SPF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within the ORAMED project a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe. The main objectives of ORAMED were to obtain a set of standardized data on doses for staff in interventional cardiology and radiology and to optimize staff protection. Doses were measured with thermoluminescent dosemeters on the ring finger and wrist of both hands, on legs and at the level of the eyes of the main operator performing interventional procedures. In this paper an overview of the doses per procedure measured during 646 interventional cardiology procedures is given for cardiac angiographies and angioplasties (CA/PTCA), radiofrequency ablations (RFA) and pacemaker and defibrillator implantations (PM/ICD). 31% of the monitored procedures were associated with no collective protective equipment, whereas 44% involved a ceiling screen and a table curtain. Although associated with the smallest air kerma - area product (KAP), PM/ICD procedures led to the highest doses. As expected, KAP and doses values exhibited a very large variability. The left side of the operator, most frequently the closest to the X-ray scattering region, was more exposed than his right side. An analysis of the effect of parameters influencing the doses, namely collective protective equipment, X-ray tube configuration and catheter access route, was performed on the doses normalized to KAP. Ceiling screen and table curtain were observed to reduce normalized doses by atmost a factor 4, much smaller than theoretical attenuation factors typical for such protections, i.e. from 10 to 100. This observation was understood as their inappropriate use by the operators and their non-optimized design. Configurations with tube above the patient led to higher normalized doses to the operator than tube below, but the effect of using a biplane X-ray suite was more complex to analyze. For CA/PTCA procedures, the upper part of the operator's body received higher normalized doses for radial than for femoral catheter access, by atmost a factor 5. This could be seen for cases with no collective protection. The eyes were observed to receive the maximum fraction of the annual dose limit almost as frequently as legs and hands, and clearly the most frequently, if the former 150 mSv and new 20 mSv recommended limits for the lens of the eye are considered, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diabetes is a common condition affecting around 69,000 people in Northern Ireland. One of the possible complications of diabetes is a condition called diabetic retinopathy, which can cause sight loss and blindness. Retinopathy causes damage to the tiny blood vessels (capillaries) that nourish the retina, the tissues in the back of the eye that deal with light. This can seriously affect vision.Research shows that if retinopathy is identified early, for example through retinal screening, and treated appropriately, blindness can be prevented in the majority of people with diabetes, both type 1 and type 2.Screening programmeIn Northern Ireland, a diabetic retinopathy screening programme (DRSP), run by the Public Health Agency, has been put in place to screen all eligible people with diabetes aged 12 years and over. Dr Bernadette Cullen, Consultant in Public Health Medicine, PHA, said: "Screening detects problems early and allows appropriate treatment to be offered. It is vital that everyone with diabetes attends diabetic retinopathy screening when it is offered. Early detection of potential problems offers a very real opportunity to intervene and, with appropriate treatment, can prevent blindness in the majority of those at risk."The screening testThe screening test involves photographs being taken of the back of each eye, using a special camera. The test is painless and takes about 15 minutes. If the person is over 50 years of age, they will need to have drops put in their eyes about 15 minutes before the test to dilate their pupils.The photographs are sent to the regional screening centre for analysis by trained graders. Results will show whether patients require further referral for assessment or treatment by hospital eye services (HES). If this is not required, screening will be offered again the following year.GPs are informed of all results and if the patient is under the care of a diabetologist, they too will be informed. Patients are informed of results by their GP and if they need an urgent referral, protocols are in place to ensure this happens.Many people with diabetes attend their optometrist (optician) on a regular basis to have a sight test for glasses. It is important they continue to do this - this test is free to people with diabetes. It is also vital that people with diabetes attend for diabetic retinopathy screening when invited, regardless of how or where their diabetes is treated, or whether they visit a hospital consultant/GP for their diabetic care.Patients are invited to screening via their GP practice. An information leaflet to help patients make an informed decision to attend for screening is also sent. This can be accessed via the PHA website: www.publichealth.hscni.net.