936 resultados para enzyme preparations


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phenylethanolamine N-methyltransferase, PNMT, utilizes the methylating cofactor S-adenosyl-L-methionine to catalyse the synthesis of adrenaline. Human PNMT has been crystallized in complex with an inhibitor and the cofactor product S-adenosyl-L-homocysteine using the hanging-drop technique with PEG 6000 and lithium chloride as precipitant. A critical requirement for crystallization was a high enzyme concentration (>90 mg ml(-1)) and cryocrystallography was used for high-quality data measurement. Diffraction data measured from a cryocooled crystal extend to a resolution of 2.3 Angstrom. Cryocooled crystals belong to space group P4(3)2(1)2 and have unit-cell parameters a = b = 94.3, c = 187.7 Angstrom.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical trials have established bosentan, an orally active non-selective endothelin (ET) receptor antagonist, as a beneficial treatment in pulmonary hypertension. Trials have also shown short-term benefits of bosentan in systemic hypertension and congestive heart failure. However, bosentan also increased plasma levels of ET-1, probably by inhibiting the clearance of ET-1 by endothelin type B (ET.) receptors, and this may mean its effectiveness is reduced with long-term clinical use. Preliminary data suggests that selective endothelin type A (ETA) receptor antagonists (BQ-123, sitaxsentan) may be more beneficial than the non-selective ET receptor antagonists in heart failure, especially when the failure is associated with pulmonary hypertension. Experimental evidence in animal disease models suggests that non-selective ET or selective ETA receptor antagonism may have a role in the treatment of athero-sclerosis, restenosis, myocarditis, shock and portal hypertension. In animal models of myocardial infarction and/or reperfusion injury, non-selective ET or selective ETA receptor antagonists have beneficial or detrimental effects depending on the conditions and agents used. Thus clinical trials of the nonselective ET or selective ETA receptor antagonists in these conditions are not presently warranted. Several selective endothelin-converting enzyme inhibitors tors have been synthesised recently, and these are only beginning to be tested in animal models of cardiovascular disease, and thus the clinical potential of these inhibitors is still to be defined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Isothermal calorimetry has been used to examine the effect of thermodynamic non-ideality on the kinetics of catalysis by rabbit muscle pyruvate kinase as the result of molecular crowding by inert cosolutes. The investigation, designed to detect substrate-mediated isomerization of pyruvate kinase, has revealed a 15% enhancement of maximal velocity by supplementation of reaction mixtures with 0.1 M proline, glycine or sorbitol. This effect of thermodynamic non-ideality implicates the existence of a substrate-induced conformational change that is governed by a minor volume decrease and a very small isomerization constant; and hence, substantiates earlier inferences that the rate-determining step in pyruvate kinase kinetics is isomerization of the ternary enzyme product complex rather than the release of products. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the development of epitope-blocking enzyme-linked immunosorbent assays (ELISAs) for the rapid detection of serum antibodies to West Nile virus (WNV) in taxonomically diverse North American avian species. A panel of flavivirus-specific monoclonal antibodies (MAbs) was tested in blocking assays with serum samples from WNV-infected chickens and crows. Selected MAbs were further tested against serum samples from birds that represented 16 species and 10 families. Serum samples were collected from birds infected with WW or Saint Louis encephalitis virus (SLEV) and from noninfected control birds. Serum samples from SLEV-infected birds were included in these experiments because WNV and SLEV are closely related antigenically, are maintained in similar transmission cycles, and have overlapping geographic distributions. The ELISA that utilized MAb 3.11126 potentially discriminated between WW and SLEV infections, as all serum samples from WNV-infected birds and none from SLEV-infected birds were positive in this assay. Assays with MAbs 2132 and 6B6C-1 readily detected serum antibodies in all birds infected with WNV and SLEV, respectively, and in most birds infected with the other virus. Two other MAbs partially discriminated between infections with these two viruses. Serum samples from most WNV-infected birds but no SLEV-infected birds were positive with MAb 3.676, while almost all serum samples from SLEV-infected birds but few from WNV-infected birds were positive with MAb 6B5A-5. The blocking assays reported here provide a rapid, reliable, and inexpensive diagnostic and surveillance technique to monitor WNV activity in multiple avian species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the ability of epitope-blocking enzyme-linked immunosorbent assays (ELISAs) to detect West Nile virus (WNV) antibodies in domestic mammals. Sera were collected from experimentally infected horses, cats, and pigs at regular intervals and screened in ELISAs and plaque reduction neutralization tests. The diagnostic efficacies of these techniques were similar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two forms of the activated beta(1)-adrenoceptor exist, one that is stabilized by (-)-noradrenaline and is sensitive to blockade by (-)-propranolol and another which is stabilized by partial agonists such as (-)-pindolol and (-)-CGP 12177 but is relatively insensitive to (-)-propranolol. We investigated the effects of stimulation of the propranolol-resistant PI-adrenoceptor in the human heart. Myocardium from non-failing and failing human hearts were set up to contract at 1 Hz. In right atrium from non-ailing hearts in the presence of 200 nM (-)-propranolol, (-)-CGP 12177 caused concentration-dependent increases in contractile force (-logEC(50)[M] 7.3+/-0.1, E-max 23+/-1% relative to maximal (-)-isoprenaline stimulation of beta(1)- and beta(2)-adrenoceptors, n=86 patients), shortening of the time to reach peak force (-logEC(50)[M] 7.4+/-0.1, E-max 37+/-5%, n=61 patients) and shortening of the time to reach 50% relaxation (t(50%), -logEC(50)[M] 7.3+/-0.1, E-max 33+/-2%, n=61 patients). The potency and maxima of the positive inotropic effects were independent of Ser49Gly- and Gly389Arg-beta(1)-adrenoceptor polymorphisms but were potentiated by the phosphodiesterase inhibitor 3-isobutyl-1-methylxanthine (-logEC(50)[M] 7.7+/-0.1, E-max 68+/-6%, n=6 patients, P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Captopril, an inhibitor of angiotensin converting enzyme (ACE), is used to treat medical conditions like hypertension and heart failure, and it is usually administered in tablet form for adults. Since this dosage form is not recommended for infants and children up to 6 years, hospital pharmacies have to prepare liquid formulations for oral administration of captopril. Traditionally, concentration of captopril used in the formulations is 1mg/ml. The problem is that captopril is prone to oxidation, and its stability in solution is affected by pH, concentration of captopril, the presence of oxygen or metal ions. The influence of different formulation ingredients on the properties of physical and chemical stability of captopril in liquid preparations has been evaluated. Main of the study: to evaluate the stability of captopril for 30 days when formulated in a 1 mg/ml suspension adjuvanted with citric acid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A square wave voltammetric (SWV) method and a flow injection analysis systemwi th electrochemical detection (FIA-EC) using a glassy carbon electrode were evaluated for the determination of codeine in pharmaceutical preparations. The interference of several compounds, such as acetaminophen,guaiacol, parabens, ephedrine, acetylsalicylic acid and caffeine, that usually appear associated with codeine pharmaceutical preparations was studied. It was verified that these electroanalytical methods could not be used with acetaminophen present in the formulations and that with guaiacol, parabens or ephedrine present the use of the FIA-EC system was impracticable. A detection limit of 5 µmol L- 1 and a linear calibration range from 40 to 140 µmol L- 1 was obtained with the SWV method. For the flow injection analysis procedure a linear calibration range was obtained from 7 to 50 µmol L- 1 with a detection limit of 3 µmol L- 1 and the FIA-EC systemallowed a sampling rate of 115 samples per hour. The results obtained by the two methods, SWV and FIA-EC, were compared with those obtained using reference methods and demonstrated good agreement, with relative deviations lower than 4%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: A new protocol for fixation and slide preservation was evaluated in order to improve the quality of immunocytochemical reactions on cytology slides. Methods: The quality of immunoreactions was evaluated retrospectively on 186 cytology slides (130 direct smears, 56 cytospins) prepared from different cytology samples. Ninety-three of the slides were air dried, stored at -20 °C and fixed in acetone for 10 minutes (Protocol 1), whereas the other 93 were immediately fixed in methanol at -20 °C for at least 30 minutes, subsequently protected with polyethylene glycol (PEG) and stored at room temperature (Protocol 2). Immunocytochemical staining, with eight primary antibodies, was performed on a Ventana BenchMark Ultra instrument using an UltraView Universal DAB Detection Kit. The following parameters were evaluated for each immunoreaction: morphology preservation, intensity of specific staining, background and counterstain. The slides were blinded and independently scored by four observers with marks from 0 to 20. Results: The quality of immunoreactions was better on methanol-fixed slides protected with PEG than on air-dried slides stored in the freezer: X¯ = 14.44 ± 3.58 versus X¯ = 11.02 ± 3.86, respectively (P < 0.001). Conclusion: Immediate fixation of cytology slides in cold methanol with subsequent application of PEG is an easy and straightforward procedure that improves the quality of immunocytochemical reactions and allows the storage of the slides at room temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to define an accurate assay for anti-adenovirus antibody detection, a recently developed ELISA was compared with IFA and CF. On 58 sera, the ELISA was more sensitive than both CF and IFA, which showed relative sensitivities of 63% and 94%, respectively. It was not possible to determine the exact specificity of the tests because of the lack of a gold standard. Furthermore, the ELISA was used to define the prevalence of adenovirus antibodies in 116 infants between 1 and 24 months old (mean 7.28). The data showed that maternal antibodies waned by the age of 5 to 6 months and that more than 80% of the children had been infected by adenoviruses by the age of 10 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sera from 472 Brazilian subjects, confirmed to be either positive or negative for HIV antibodies and comprising the total clinical spectrum of HIV infection, were utilized in the evaluation of six commercially available enzyme-linked immunosorbent assays (ELISA), as well as of four alternative assays, namely indirect immunofluorescence (IIF), passive hemagglutination (PHA), dot blot and Karpas AIDS cell test. The sensitivities ranged from 100% (Abbott and Roche ELISA) to 84.2% (PHA) and the specificities ranged from 99.3% (IIF) to 80.2% (PHA). The sensitivity and specificity of the PHA and the sensitivity of the Karpas cell test were significantly lower than those of the other tests. Although the IFF and dot blot had good sensitivities and specificities, the six ELISA were more attractive than those tests when other parameters such as ease of reading and duration of assay were considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An enzyme-linked immunosorbent assay (ELISA) for measles antibodies was compared with Plaque Neutralization (PRN), Haemagglutination inhibition (HI) and Fluorescent antibody (IFA) tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%). IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An Enzyme-linked immunosorbent assay ELISA was evaluated for the detection of IgA antibodies in the human leptospirosis. The assay proved to be sensitive and specific when compared with the ELISA-IgM, in the examinated serum samples. The results found suggest that IgA antibodies became positive later in leptospirosis, and will can be an evolutive indicator in the development of the disease

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydatid disease in tropical areas poses a serious diagnostic problem due to the high frequence of cross-reactivity with other endemic helminthic infections. The enzyme-linked-immunosorbent assay (ELISA) and the double diffusion arc 5 showed respectively a sensitivity of 73% and 57% and a specificity of 84-95% and 100%. However, the specificity of ELISA was greatly increased by using ovine serum and phosphorylcholine in the diluent buffer. The hydatic antigen obtained from ovine cyst fluid showed three main protein bands of 64,58 and 30 KDa using SDS PAGE and immunoblotting. Sera from patients with onchocerciasis, cysticercosis, toxocariasis and Strongyloides infection cross-reacted with the 64 and 58 KDa bands by immunoblotting. However, none of the analyzed sera recognized the 30 KDa band, that seems to be specific in this assay. The immunoblotting showed a sensitivity of 80% and a specificity of 100% when used to recognize the 30 KDa band.