882 resultados para energy requirement model
Resumo:
Previous work has demonstrated that observed and modeled climates show a near-time-invariant ratio of mean land to mean ocean surface temperature change under transient and equilibrium global warming. This study confirms this in a range of atmospheric models coupled to perturbed sea surface temperatures (SSTs), slab (thermodynamics only) oceans, and a fully coupled ocean. Away from equilibrium, it is found that the atmospheric processes that maintain the ratio cause a land-to-ocean heat transport anomaly that can be approximated using a two-box energy balance model. When climate is forced by increasing atmospheric CO2 concentration, the heat transport anomaly moves heat from land to ocean, constraining the land to warm in step with the ocean surface, despite the small heat capacity of the land. The heat transport anomaly is strongly related to the top-of-atmosphere radiative flux imbalance, and hence it tends to a small value as equilibrium is approached. In contrast, when climate is forced by prescribing changes in SSTs, the heat transport anomaly replaces ‘‘missing’’ radiative forcing over land by moving heat from ocean to land, warming the land surface. The heat transport anomaly remains substantial in steady state. These results are consistent with earlier studies that found that both land and ocean surface temperature changes may be approximated as local responses to global mean radiative forcing. The modeled heat transport anomaly has large impacts on surface heat fluxes but small impacts on precipitation, circulation, and cloud radiative forcing compared with the impacts of surface temperature change. No substantial nonlinearities are found in these atmospheric variables when the effects of forcing and surface temperature change are added.
Resumo:
Changes in the depth of Lake Viljandi between 1940 and 1990 were simulated using a lake water and energy-balance model driven by standard monthly weather data. Catchment runoff was simulated using a one-dimensional hydrological model, with a two-layer soil, a single-layer snowpack, a simple representation of vegetation cover and similarly modest input requirements. Outflow was modelled as a function of lake level. The simulated record of lake level and outflow matched observations of lake-level variations (r = 0.78) and streamflow (r = 0.87) well. The ability of the model to capture both intra- and inter-annual variations in the behaviour of a specific lake, despite the relatively simple input requirements, makes it extremely suitable for investigations of the impacts of climate change on lake water balance.
Resumo:
Considering the sea ice decline in the Arctic during the last decades, polynyas are of high research interest since these features are core areas of new ice formation. The determination of ice formation requires accurate retrieval of polynya area and thin-ice thickness (TIT) distribution within the polynya.We use an established energy balance model to derive TITs with MODIS ice surface temperatures (Ts) and NCEP/DOE Reanalysis II in the Laptev Sea for two winter seasons. Improvements of the algorithm mainly concern the implementation of an iterative approach to calculate the atmospheric flux components taking the atmospheric stratification into account. Furthermore, a sensitivity study is performed to analyze the errors of the ice thickness. The results are the following: 1) 2-m air temperatures (Ta) and Ts have the highest impact on the retrieved ice thickness; 2) an overestimation of Ta yields smaller ice thickness errors as an underestimation of Ta; 3) NCEP Ta shows often a warm bias; and 4) the mean absolute error for ice thicknesses up to 20 cm is ±4.7 cm. Based on these results, we conclude that, despite the shortcomings of the NCEP data (coarse spatial resolution and no polynyas), this data set is appropriate in combination with MODIS Ts for the retrieval of TITs up to 20 cm in the Laptev Sea region. The TIT algorithm can be applied to other polynya regions and to past and future time periods. Our TIT product is a valuable data set for verification of other model and remote sensing ice thickness data.
Resumo:
A new class of accelerating cosmological models driven by a one-parameter version of the general Chaplygin-type equation of state is proposed. The simplified version is naturally obtained from causality considerations with basis on the adiabatic sound speed vs plus the observed accelerating stage of the universe. We show that very stringent constraints on the unique free parameter a describing the simplified Chaplygin model can be obtained from a joint analysis involving the latest SNe type la data and the recent Sloan Digital Sky Survey measurement of baryon acoustic oscillations (BAO). In our analysis we have considered separately the SNe type la gold sample measured by [A.G. Riess et al.. Astrophys. J. 607 (2004) 665] and the supernova legacy survey (SNLS) from [P. Astier et al., Astron. Astrophys. 447 (2006) 31]. At 95.4% (c.l.), we find for BAO + gold sample, 0.91 <= alpha <= 1.0 and Omega(m) = 0.28(-0.048)(+0.043) while BAO + SNLS analysis provides 0.94 <= alpha <= 1.0 and Omega(m) = 0.27(-0.045)(+0.048). (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
This work reports on the excited-state absorption spectrum of oxidized Cytochrome c (Fe(3+)) dissolved in water, measured with the Z-scan technique with femtosecond laser pulses. The excited-state absorption cross-sections between 460 and 560 nm were determined with the aid of a three-energy-level model. Reverse saturable absorption was observed below 520 nm, while a saturable absorption process occurs in the Q-band, located around 530 nm. Above 560 nm, a competition between saturable absorption and two-photon absorption was inferred. These results show that Cytochrome c presents distinct nonlinear behaviors, which may be useful to study electron transfer chemistry in proteins by one- and two-photon absorption. In addition, owing to these nonlinear optical features, this molecule may be employed in applications involving photodynamics therapy and saturable absorbers. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The excited-state dynamics of two polyfluorene copolymers, one fully conjugated containing phenylene vinylene units alternated with 9,9`-dihexylfluorenyl groups and the other segmented by -(CH2)(8)- spacer, were studied in dilute solution of different solvents using a picosecond single-photon timing technique. The excited-state dynamics of the segmented copolymer follows the Forster resonant energy-transfer model which describes intrachain energy-transfer kinetics among random oriented chromophores. Energy transfer is confirmed by analysis of fluorescence anisotropy relaxation with the measurement of a short decay component of about 60 ps. The fluorescence decay surface of the fully conjugated copolymer is biexponential with decay times of about 470 and 900 ps, ascribed to deactivation of chain moieties containing trans and cis isomers already in a photostationary condition. Thus, energy transfer is very fast due to the conjugated nature and rigid-rod-like structure of this copolymer chain.
Resumo:
Hybrid Photovoltaic Thermal (PVT) collectors are an emerging technology that combines PV and solar thermal systems in a single solar collector producing heat and electricity simultaneously. The focus of this thesis work is to evaluate the performance of unglazed open loop PVT air system integrated on a garage roof in Borlänge. As it is thought to have a significant potential for preheating ventilation of the building and improving the PV modules electrical efficiency. The performance evaluation is important to optimize the cooling strategy of the collector in order to enhance its electrical efficiency and maximize the production of thermal energy. The evaluation process involves monitoring the electrical and thermal energies for a certain period of time and investigating the cooling effect on the performance through controlling the air mass flow provided by a variable speed fan connected to the collector by an air distribution duct. The distribution duct transfers the heated outlet air from the collector to inside the building. The PVT air collector consists of 34 Solibro CIGS type PV modules (115 Wp for each module) which are roof integrated and have replaced the traditional roof material. The collector is oriented toward the south-west with a tilt of 29 ᵒ. The collector consists of 17 parallel air ducts formed between the PV modules and the insulated roof surface. Each air duct has a depth of 0.05 m, length of 2.38 m and width of 2.38 m. The air ducts are connected to each other through holes. The monitoring system is based on using T-type thermocouples to measure the relevant temperatures, air sensor to measure the air mass flow. These parameters are needed to calculate the thermal energy. The monitoring system contains also voltage dividers to measure the PV modules voltage and shunt resistance to measure the PV current, and AC energy meters which are needed to calculate the produced electrical energy. All signals recorded from the thermocouples, voltage dividers and shunt resistances are connected to data loggers. The strategy of cooling in this work was based on switching the fan on, only when the difference between the air duct temperature (under the middle of top of PV column) and the room temperature becomes higher than 5 °C. This strategy was effective in term of avoiding high electrical consumption by the fan, and it is recommended for further development. The temperature difference of 5 °C is the minimum value to compensate the heat losses in the collecting duct and distribution duct. The PVT air collector has an area of (Ac=32 m2), and air mass flow of 0.002 kg/s m2. The nominal output power of the collector is 4 kWppv (34 CIGS modules with 115 Wppvfor each module). The collector produces thermal output energy of 6.88 kWth/day (0.21 kWth/m2 day) and an electrical output energy of 13.46 kWhel/day (0.42 kWhel/m2 day) with cooling case. The PVT air collector has a daily thermal energy yield of 1.72 kWhth/kWppv, and a daily PV electrical energy yield of 3.36 kWhel /kWppv. The fan energy requirement in this case was 0.18 kWh/day which is very small compared to the electrical energy generated by the PV collector. The obtained thermal efficiency was 8 % which is small compared to the results reported in literature for PVT air collectors. The small thermal efficiency was due to small operating air mass flow. Therefore, the study suggests increasing the air mass flow by a factor of 25. The electrical efficiency was fluctuating around 14 %, which is higher than the theoretical efficiency of the PV modules, and this discrepancy was due to the poor method of recording the solar irradiance in the location. Due to shading effect, it was better to use more than one pyranometer.
Resumo:
Electrical resistive heating (ERH) is a thermal method used to improve oil recovery. It can increase oil rate and oil recovery due to temperature increase caused by electrical current passage through oil zone. ERH has some advantage compared with well-known thermal methods such as continuous steam flood, presenting low-water production. This method can be applied to reservoirs with different characteristics and initial reservoir conditions. Commercial software was used to test several cases using a semi-synthetic homogeneous reservoir with some characteristics as found in northeast Brazilian basins. It was realized a sensitivity analysis of some reservoir parameters, such as: oil zone, aquifer presence, gas cap presence and oil saturation on oil recovery and energy consumption. Then it was tested several cases studying the electrical variables considered more important in the process, such as: voltage, electrical configurations and electrodes positions. Energy optimization by electrodes voltage levels changes and electrical settings modify the intensity and the electrical current distribution in oil zone and, consequently, their influences in reservoir temperature reached at some regions. Results show which reservoir parameters were significant in order to improve oil recovery and energy requirement in for each reservoir. Most significant parameters on oil recovery and electrical energy delivered were oil thickness, presence of aquifer, presence of gas cap, voltage, electrical configuration and electrodes positions. Factors such as: connate water, water salinity and relative permeability to water at irreducible oil saturation had low influence on oil recovery but had some influence in energy requirements. It was possible to optimize energy consumption and oil recovery by electrical variables. Energy requirements can decrease by changing electrodes voltages during the process. This application can be extended to heavy oil reservoirs of high depth, such as offshore fields, where nowadays it is not applicable any conventional thermal process such as steam flooding
Resumo:
O sucesso de um programa de perda de peso para animais de estimação depende da colaboração do proprietário. A adesão deste é fundamental para a correta instituição do manejo alimentar do paciente. Este trabalho teve por objetivo comparar a efetividade de um programa de perda de peso em dois grupos de cães, um mantido sob condições experimentais e outro com seus proprietários. Empregou-se a mesma ração hipocalórica para todos os animais. A quantidade fornecida foi restrita a 60% da necessidade energética de manutenção estimada para o peso corporal meta, definido como o peso autal reduzido em 15%. Os animais foram acompanhados durante 90 dias. Por meio de um questionário padronizado, estudou-se a percepção dos proprietários quanto à obesidade e seu tratamento. Verificou-se que o protocolo e a dieta empregados foram eficazes. Os animais controle apresentaram uma perda de peso média de 1,39% por semana. Os cães de proprietário perderam, em média, 0,75% do peso vivo por semana, resultado estatisticamente menor (P<0,05), o que sugere uma indisponibilidade dos mesmos em cumprir rigorosamente o tratamento. Mesmo com esta perda de peso modesta, foi perceptível a satisfação dos proprietários com os resultados obtidos. O uso de questionários demonstrou ser uma ferramenta importante na investigação das causas e no acompanhamento do tratamento da obesidade canina.
Resumo:
Nutrition for broilers under high temperatures is extremely important for brazilian broiler chicken industry because the amounts of consumed nutrients and environmental temperature have great effects on bird performance and carcass quality. Among diet nutrients, protein has the highest heat increment; thus, during many years, diets with low protein level were recommended in order to reduce heat production in broiler chickens under heat stress. However, reports have shown that low-protein diets have negative effects on broiler performance when environmental temperature is high, because during heat stress, low food intake associated to a low diet protein induce amino acid deficiencies. Other studies have shown that broilers fed low-protein diets increase their energy requirement for maintenance with higher heat production. Thus, with the growth of broiler industry in tropical areas more challenges need to be faced by the farmers. So, both the ambient and nutritional conditions ought to be well managed to avoid negative effects on poultry production once they can affect the metabolism (body heat production under low temperature and body heat dissipation under high temperature) with consequence on poultry performance (meat and eggs).
Resumo:
Foram conduzidos três ensaios para avaliar os níveis de energia metabolizável (EM) e a melhor relação energia:proteína (E:P) para aves de corte machos de crescimento lento criadas em semiconfinamento nas fases inicial (1 a 21), de crescimento (22 a 49) e de terminação (50 a 70 dias de idade). em cada ensaio, 400 machos da linhagem ISA Label na fase de criação foram alojados em instalação experimental constituída de 20 piquetes com área coberta de 3,13 m²para alimentação e recolhimento das aves e uma área de pastejo de 72,87 m². O delineamento experimental foi o inteiramente casualizado com cinco tratamentos e quatro repetições de 20 aves. Os níveis de energia metabolizável fornecidos na ração na fase inicial variaram de 2.600 a 3.200 kcal/kg; na fase de crescimento de 2.700 a 3.300 kcal/kg; e na fase final de 2.800 a 3.400 kcal/kg. A proteína bruta e os demais nutrientes foram mantidos constantes em todas as rações, de acordo com recomendações do NRC (1994) para cada fase. A relação energia:proteína e o nível de energia metabolizável que melhoraram o desempenho e as características da carcaça de frangos de corte ISA Label machos criados em sistema semiconfinado em cada fase estudada foram 128 e 2.750; 147 e 2.850 e 172 e 3.100 kcal de EM/kg nas fases inicial, de crescimento e de terminação, respectivamente.
Resumo:
O objetivo do trabalho foi elaborar um modelo para estimar as exigências de proteína bruta (PB) para poedeiras leves, usando o método fatorial. Para determinar as exigências de proteína bruta (PB) para manutenção foi utilizada a técnica do balanço de nitrogênio. A exigência de proteína bruta para o ganho de peso foi determinada em função do conteúdo de nitrogênio na carcaça e a eficiência de utilização do nitrogênio da dieta. A exigência de PB, para produção de ovos, foi determinada considerando o teor de PB determinado nos ovos e a eficiência de deposição do nitrogênio no ovo. A partir dos valores das exigências para manutenção, para o ganho e produção foi elaborada uma equação para predizer as exigências diárias de PB (g/ ave/ dia) para poedeiras: PB = 1,94. P0,75 + 0,48.G + 0,301.O, em que P = peso corporal (kg), G = ganho de peso diário (g/dia) e O = massa de ovos produzida (g/ave/dia).
Resumo:
The Electrical Submersible Pump (ESP) has been one of the most appropriate solutions for lifting method in onshore and offshore applications. The typical features for this application are adverse temperature, viscosity fluids and gas environments. The difficulties in equipments maintenance and setup contributing to increasing costs of oil production in deep water, therefore, the optimization through automation can be a excellent approach for decrease costs and failures in subsurface equipment. This work describe a computer simulation related with the artificial lifting method ESP. This tool support the dynamic behavior of ESP approach, considering the source and electric energy transmission model for the motor, the electric motor model (including the thermal calculation), flow tubbing simulation, centrifugal pump behavior simulation with liquid nature effects and reservoir requirements. In addition, there are tri-dimensional animation for each ESP subsytem (transformer, motor, pump, seal, gas separator, command unit). This computer simulation propose a improvement for monitoring oil wells for maximization of well production. Currenty, the proprietaries simulators are based on specific equipments manufactures. Therefore, it is not possible simulation equipments of another manufactures. In the propose approach there are support for diverse kinds of manufactures equipments
Resumo:
As informações da avaliação de mecanismos de abertura de sulco de semeadoras de plantio direto auxiliam as empresas no dimensionamento de ferramentas rompedoras do solo, que buscam menor requerimento energético. Este trabalho foi realizado num solo classificado como Latossolo Vermelho com o objetivo de avaliar tridimensionalmente os esforços dos mecanismos de abertura de sulco de semeadoras adubadoras de plantio direto. O delineamento experimental utilizado foi o de blocos ao acaso com cinco tratamentos, sendo cinco mecanismos de abertura de sulco (disco liso - DL, disco corrugado - DC, disco ondulado - DO, disco duplo - DD e haste sulcadora - H). Para mensurar os esforços dos mecanismos de abertura de sulco, foi utilizado um dinamômetro com sensibilidade nas direções horizontal, transversal e vertical e no momento fletor e torsor. A avaliação mostrou que a interação entre mecanismos de abertura de sulco e carga vertical não foi significativa, entretanto os fatores foram significativos quando analisados individualmente. O resultado individual dos mecanismos de abertura de sulco mostrou que o disco ondulado proporcionou maior área de mobilização do solo, a haste sulcadora apresentou o menor valor de força vertical e o disco duplo e a haste sulcadora obtiveram o menor esforço horizontal.
Resumo:
Both the inadequate use and the ignorance of the different soil tillage implements available in the home market has become one of the leading motives of failures, related to soil and water conservation. The periodical tillage is traditionally utilized after subsoiling for soil clod breaking, leveling and residue incorporation. This work aimed to evaluate the energy requirement for different periodical soil tillage systems performed before and after subsoiling in a soil classified as Distroferric Red Nitosol. The periodic tillage systems were: disk plowing; disk plowing plus one leveling harrowing; disk harrow; disk harrow plus leveling harrowing stirring. The experimental design was a 5x2 factorial scheme with 5 completely randomized blocks. The results show that the periodic soil preparation systems based on disks have better energy efficiency when performed before the operation of subsoiling. The system of soil preparation with harrowing obtained the lower energy demand, in relation to other periodic soil preparation systems, when done after subsoiling.