425 resultados para endoscopic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECT Endoscopic third ventriculostomy (ETV) is the procedure of choice in the treatment of obstructive hydrocephalus. The excellent clinical and radiological success rates are well known. Nevertheless, very few papers have addressed the very long term outcomes of the procedure in very large series. The authors present a large case series of 113 patients who underwent 126 ETVs, and they highlight the initial postoperative outcome after 3 months and long-term follow-up with an average of 7 years. METHODS All patients who underwent ETV at the Department of Neurosurgery, Mainz University Hospital, between 1993 and 1999 were evaluated. Obstructive hydrocephalus was the causative pathology in all cases. RESULTS The initial clinical success rate was 82% and decreased slightly to 78% during long-term follow-up. Long-term success was analyzed using Kaplan-Meier curves. Overall, ETV failed in 31 patients. These patients underwent a second ETV or shunt treatment. A positive impact on long-term success was seen for age older than 6 months, and for obstruction due to cysts or benign aqueductal stenosis. The complication rate was 9% with 5 intraoperative and 5 postoperative events. CONCLUSIONS The high clinical success rate in short-term and long-term follow-up confirms ETV's status as the gold standard for the treatment of obstructive hydrocephalus, especially for distinct pathologies. The patient's age and underlying pathology may influence the outcome. These factors should be considered carefully preoperatively by the surgeon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The EVA (Endoscopic Video Analysis) tracking system a new tracking system for extracting motions of laparoscopic instruments based on non-obtrusive video tracking was developed. The feasibility of using EVA in laparoscopic settings has been tested in a box trainer setup. METHODS: EVA makes use of an algorithm that employs information of the laparoscopic instrument's shaft edges in the image, the instrument's insertion point, and the camera's optical centre to track the 3D position of the instrument tip. A validation study of EVA comprised a comparison of the measurements achieved with EVA and the TrEndo tracking system. To this end, 42 participants (16 novices, 22 residents, and 4 experts) were asked to perform a peg transfer task in a box trainer. Ten motion-based metrics were used to assess their performance. RESULTS: Construct validation of the EVA has been obtained for seven motion-based metrics. Concurrent validation revealed that there is a strong correlation between the results obtained by EVA and the TrEndo for metrics such as path length (p=0,97), average speed (p=0,94) or economy of volume (p=0,85), proving the viability of EVA. CONCLUSIONS: EVA has been successfully used in the training setup showing potential of endoscopic video analysis to assess laparoscopic psychomotor skills. The results encourage further implementation of video tracking in training setups and in image guided surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work covers the first validation efforts of the EVA Tracking System for the assessment of minimally invasive surgery (MIS) psychomotor skills. Instrument movements were recorded for 42 surgeons (4 expert, 22 residents, 16 novice medical students) and analyzed for a box trainer peg transfer task. Construct validation was established for 7/9 motion analysis parameters (MAPs). Concurrent validation was determined for 8/9 MAPs against the TrEndo Tracking System. Finally, automatic determination of surgical proficiency based on the MAPs was sought by 3 different approaches to supervised classification (LDA, SVM, ANFIS), with accuracy results of 61.9%, 83.3% and 80.9% respectively. Results not only reflect on the validation of EVA for skills? assessment, but also on the relevance of motion analysis of instruments in the determination of surgical competence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Minimally invasive surgery creates two technological opportunities: (1) the development of better training and objective evaluation environments, and (2) the creation of image guided surgical systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"State-of-the Science Conference on Endoscopic Retrograde Cholangiopancreatography (ERCP) for Diagnosis and Therapy was convened on January 14-16, 2002"--P. 5.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Until recently, fetoscopic laser surgery to seal the placental anastomoses that cause severe twin-to-twin transfusion syndrome has been available in only a few centres worldwide. The technique typically takes a long time to learn. We have used a dedicated Internet Protocol (IP) connection for tele-education to assist the introduction of fetoscopic laser surgery to Australia. During the implementation of the international telemedicine link, there were multiple clinical and technical problems, which were eventually overcome. The quality of images and of video-sequences was comparable to that supported by an ISDN connection. Pictures of live surgery performed by an expert in Florida, USA, were transmitted and viewed by a novice team in Brisbane, Australia. The Australian team has performed 19 fetoscopic laser operations to date. Preliminary results are comparable to those from centres that have performed over 100 procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: CO2 monitoring is recommended for thoracic telescopic procedures and for spontaneous breathing general anesthesia in children. During flexible bronchoscopy (FB) in children, the various currently available methods of CO2 measurements are limited. The CO2 falls and increases have been reported in FB but it is unknown whether airway lesions predispose to CO2 change. The aim of this study was to describe and validate endoscopic intratracheal CO2 measurements in children undergoing FB under spontaneously breathing GA. Methods: Endtidal CO2 (PECO2) measurements at the start (Start-CO2) and end (End-CO2) of FB on 100 consecutive children were performed using a newly designed endoscopic intratracheal method. To validate the method blood gas sampling was simultaneously performed in 28 children and results analyzed using the Bland and Altman method, intraclass correlation and 95% range for repeatability. Results: End-CO2 and CO2-change (End-CO2 minus Start-CO2) were significantly different in children with airway lesions (CO2 change: no lesion = 3 mmHg, extrathoracic airway lesion = 4.5, intrathoracic airway lesion = 8, P = 0.038). There was no significant difference in Start-CO2 values among the groups. CO2-change in those aged > 12 months was similar to those >12 months. Intratracheal CO2 measurements were comparable with arterial blood values in the Bland and Altman plots. The intraclass correlation was 0.69 and 95% range for repeatability was 3.7-4.17 mmHg. Conclusions: Midtracheal PECO2 provides a useful estimate of PaCO2 for monitoring the respiratory status of children undergoing FB. The presence of airway lesions rather than age is associated with significant increased PCO2 rise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: From the experience of a large combined series of transperitoneal. (TP) and retroperitoneal (RP) endoscopic complete and partial nephroureterectornies in children, we present a logical selective endoscopic approach to benign renal pathology. Materials and Methods: During a 5-year period 122 complete nephrectomies and nephroureterectomies (bilateral 2, invisible ectopic 8) and 63 partial nephroureterectomies for duplex (52 upper, 8 lower) or singleton polar disease (xanthogranulomatous pyelonephritis 1, cyst 2) were performed. Of the partial nephrectomies, ureterectomy, bladder repair and lower moiety reimplantation were performed in 8. Patient age ranged from 2.7 months to 14 years (mean 2.9 years). Preoperative weight ranged from 2.7 to 98 kg (mean 12.3). The position of the renal remnant, the presence or absence of a refluxing ureter and the need for ureterectomy were the major determining factors affecting choice of endoscopic approach. Results: A total of 179 (96.7%) procedures were successfully completed endoscopically. The 6 open conversions (3.2%) occurred early in our experience. The operating time reflected the complexity of the excision and lower urinary reconstruction (lateral and posterior RP 25 to 145 minutes [mean 921) TP with ureterocelectomy and bladder neck repair 105 to 355 minutes [mean 153]. Hospital stay for RP and simple TP was 1.5 days (mean 1 to 4) and for complicated TP 2 to 8 days (mean 3.5). Conclusions: We suggest a posterior retroperitoneal approach with isolated renal excision without extended ureterectomy. The lateral retroperitoneal approach allows complete ureterectomy as well as better exposure to horseshoe and pelvic kidneys and, therefore, avoids exposure to intraperitoneal. structures. Finally, the transperitoneal approach is recommended when complete moiety excision with lower urinary reconstruction is anticipated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study Design. Prospective clinical case series. Objective. To evaluate the clinical outcome of anterior endoscopic instrumention for scoliosis using the SRS-24 questionnaire and to examine how these scores change over a 2-year follow-up period. Summary of Background Data. Anterior endoscopic instrumentation correction has several advantages compared with open procedures. However, the clinical results of this technique using a validated outcome measure have rarely been reported in the literature. Methods. A total of 83 consecutive patients underwent endoscopic anterior instrumentation performed at a single unit. Patients completed the SRS-24 questionnaire before surgery and at 3, 6, 12, and 24 months after surgery. The SRS-24 scores were compared between each of the follow-up intervals. Results. The pain, general self-image, and function from back condition domains improved after surgery (P < 0.05). Activity level significantly improved between 3 and 6 months, and both function domains improved between 6 and 12 months (P < 0.05). None of the domains increased significantly after 1 year. Conclusions. Endoscopic anterior instrumentation for scoliosis significantly improved pain, self-image, and function. The greatest improvement in function occurred between 6 and 12 months after surgery. The SRS-24 scores at 1 year from surgery may provide a good indicator of patient outcome in the long-term.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a characterization of the acoustic sensitivity of microstructured polymer optical fiber interferometric sensors at ultrasonic frequencies from 100kHz to 10MHz. The use of wide-band ultrasonic fiber optic sensors in biomedical ultrasonic and optoacoustic applications is an open alternative to conventional piezoelectric transducers. These kind of sensors, made of biocompatible polymers, are good candidates for the sensing element in an optoacoustic endoscope because of its high sensitivity, its shape and its non-brittle and non-electric nature. The acoustic sensitivity of the intrinsic fiber optic interferometric sensors depends strongly of the material which is composed of. In this work we compare experimentally the intrinsic ultrasonic sensitivities of a PMMA mPOF with other three optical fibers: a singlemode silica optical fiber, a single-mode polymer optical fiber and a multimode graded-index perfluorinated polymer optical fiber. © 2014 SPIE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Focal points: A systematic review of the use of proton pump inhibitors was conducted among patients undergoing diagnostic fibreoptic endoscopic examination of the upper gastrointestinal tract during the period July 2001 to February 2002 inclusive A total of 2,557 patients received a PPI following endoscopy and healing doses were prescribed to 75.3 per cent of these patients An “unknown indication” was stated as a diagnosis in 958 patients (37.5 per cent) of patients studied Although endoscopic diagnosis does not appear possible in all cases, the present study demonstrates that NICE guidance to employ the lowest appropriate dose of PPI is followed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Opto-acoustic imaging (OAI) shows particular promise for in-vivo biomedical diagnostics. Its applications include cardiovascular, gastrointestinal and urogenital systems imaging. Opto-acoustic endoscopy (OAE) allows the imaging of body parts through cavities permitting entry. The critical parameter is the physical size of the device, allowing compatibility with current technology, while governing flexibility of the distal end of the endoscope based on the needs of the sensor. Polymer optical fibre (POF) presents a novel approach for endoscopic applications and has been positively discussed and compared in existing publications. A great advantage can be obtained for endoscopy due to a small size and array potential to provide discrete imaging speed improvements. Optical fibre exhibits numerous advantages over conventional piezo-electric transducers, such as immunity from electromagnetic interference and a higher resolution at small sizes. Furthermore, micro structured polymer optical fibres offer over 12 times the sensitivity of silica fibre. We present a polymer fibre Bragg grating ultrasound detector with a core diameter of 125 microns. We discuss the ultrasonic signals received and draw conclusions on the opportunities and challenges of applying this technology in biomedical applications.