tThis work is devoted to the investigation of zirconium oxynitride (ZrOxNy) films with varied opticalresponses prompted by the variations in their compositional and structural properties. The films wereprepared by dc reactive magnetron sputtering of Zr, using Ar and a reactive gas mixture of N2+ O2(17:3).The colour of the films changed from metallic-like, very bright yellow-pale and golden yellow, for low gasflows to red-brownish for intermediate gas flows. Associated to this colour change there was a significantdecrease of brightness. With further increase of the reactive gas flow, the colour of the samples changedfrom red-brownish to dark blue or even to interference colourations. The variations in composition dis-closed the existence of four different zones, which were found to be closely related with the variationsin the crystalline structure. XRD analysis revealed the change from a B1 NaCl face-centred cubic zirco-nium nitride-type phase for films prepared with low reactive gas flows, towards a poorly crystallizedover-stoichiometric nitride phase, which may be similar to that of Zr3N4with some probable oxygeninclusions within nitrogen positions, for films prepared with intermediate reactive gas flows. For highreactive gas flows, the films developed an oxynitride-type phase, similar to that of -Zr2ON2with someoxygen atoms occupying some of the nitrogen positions, evolving to a ZrO2monoclinic type structurewithin the zone where films were prepared with relatively high reactive gas flows. The analysis carriedout by reflected electron energy loss spectroscopy (REELS) revealed a continuous depopulation of thed-band and an opening of an energy gap between the valence band (2p) and the Fermi level close to 5 eV.The ZrN-based coatings (zone I and II) presented intrinsic colourations, with a decrease in brightness anda colour change from bright yellow to golden yellow, red brownish and dark blue. Associated to thesechanges, there was also a shift of the reflectivity minimum to lower energies, with the increase of thenon-metallic content. The samples lying in the two last zones (zone III, oxynitride and zone IV, oxide films)revealed a typical semi-transparent-optical behaviour showing interference-like colourations only dueto the complete depopulation of the d band at the Fermi level. The samples lying in these zones presentedalso an increase of the optical bandgap from 2 to 3.6 eV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lithium-ion battery cathodes have been fabricated by screen-printing through the development of CLiFePO4 inks. It is shown that shear thinning polymer solutions in N-methyl-2-pyrrolidone (NMP) with Newtonian viscosity above 0.4 Pa s are the best binders for formulating a cathode paste with satisfactory film forming properties. The paste shows an elasticity of the order of 500 Pa and, after shear yielding, shows an apparent viscosity of the order of 3 Pa s for shear rates corresponding to those used during screen-printing. The screen-printed cathode produced with a thickness of 26 mm shows a homogeneous distribution of the active material, conductive additive and polymer binder. The total resistance and diffusion coefficient of the cathode are 450 V and 2.5 10 16cm2 s 1, respectively. The developed cathodes show an initial discharge capacity of 48.2 mAh g 1 at 5C and a discharge value of 39.8 mAh g 1 after 50 cycles. The capacity retention of 83% represents 23% of the theoretical value (charge and/or discharge process in twenty minutes), demonstrating the good performance of the battery. Thus, the developed C-LiFePO4 based inks allow to fabricate screen-printed cathodes suitable for printed lithium-ion batteries

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Natural mineral waters (still), effervescent natural mineral waters (sparkling) and aromatized waters with fruit-flavors (still or sparkling) are an emerging market. In this work, the capability of a potentiometric electronic tongue, comprised with lipid polymeric membranes, to quantitatively estimate routinely quality physicochemical parameters (pH and conductivity) as well as to qualitatively classify water samples according to the type of water was evaluated. The study showed that a linear discriminant model, based on 21 sensors selected by the simulated annealing algorithm, could correctly classify 100 % of the water samples (leave-one out cross-validation). This potential was further demonstrated by applying a repeated K-fold cross-validation (guaranteeing that at least 15 % of independent samples were only used for internal-validation) for which 96 % of correct classifications were attained. The satisfactory recognition performance of the E-tongue could be attributed to the pH, conductivity, sugars and organic acids contents of the studied waters, which turned out in significant differences of sweetness perception indexes and total acid flavor. Moreover, the E-tongue combined with multivariate linear regression models, based on sub-sets of sensors selected by the simulated annealing algorithm, could accurately estimate waters pH (25 sensors: R 2 equal to 0.99 and 0.97 for leave-one-out or repeated K-folds cross-validation) and conductivity (23 sensors: R 2 equal to 0.997 and 0.99 for leave-one-out or repeated K-folds cross-validation). So, the overall satisfactory results achieved, allow envisaging a potential future application of electronic tongue devices for bottled water analysis and classification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project was funded under the Applied Research Grants Scheme administered by Enterprise Ireland. The project was a partnership between Galway - Mayo Institute of Technology and an industrial company, Tyco/Mallinckrodt Galway. The project aimed to develop a semi - automatic, self - learning pattern recognition system capable of detecting defects on the printed circuits boards such as component vacancy, component misalignment, component orientation, component error, and component weld. The research was conducted in three directions: image acquisition, image filtering/recognition and software development. Image acquisition studied the process of forming and digitizing images and some fundamental aspects regarding the human visual perception. The importance of choosing the right camera and illumination system for a certain type of problem has been highlighted. Probably the most important step towards image recognition is image filtering, The filters are used to correct and enhance images in order to prepare them for recognition. Convolution, histogram equalisation, filters based on Boolean mathematics, noise reduction, edge detection, geometrical filters, cross-correlation filters and image compression are some examples of the filters that have been studied and successfully implemented in the software application. The software application developed during the research is customized in order to meet the requirements of the industrial partner. The application is able to analyze pictures, perform the filtering, build libraries, process images and generate log files. It incorporates most of the filters studied and together with the illumination system and the camera it provides a fully integrated framework able to analyze defects on printed circuit boards.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Es presenten els resultats d’una enquesta sobre l’ús de revistes electròniques realitzada al professorat de les universitats que formen el Consorci de Biblioteques Universitàries de Catalunya (CBUC). Els resultats mostren un elevat grau de coneixement de la col·lecció de revistes electròniques entre el personal docent i investigador i una creixent preferència pel format electrònic en detriment de l’imprès. L’alt grau de coneixement i d’ús dels títols electrònics, i la preferència per aquest suport, comporten una elevada valoració de la col·lecció de revistes electròniques. Al mateix temps, la major part dels usuaris preveu un increment de l’ús dels títols electrònics durant els propers anys. Els resultats també confirmen la importància de la disciplina i de l’edat com a factors explicatius de l’ús de les revistes electròniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Incomplete compliance is one of several possible causes of uncontrolled hypertension. Yet, non-compliance remains largely unrecognized and is falsely interpreted as treatment resistance, because it is difficult to confirm or exclude objectively. The goal of this study was to evaluate the potential benefits of electronic monitoring of drug compliance in the management of patients with resistant hypertension. METHODS: Forty-one hypertensive patients resistant to a three-drug regimen (average blood pressure 156/ 106 +/- 23/11 mmHg, mean +/- SD) were studied prospectively. They were informed that for the next 2 months, their presently prescribed drugs would be provided in electronic monitors, without any change in treatment, so as to provide the treating physician with a measure of their compliance. Thereafter, patients were offered the possibility of prolonging the monitoring of compliance for another 2 month period, during which treatment was adapted if necessary. RESULTS: Monitoring of compliance alone was associated with a significant improvement of blood pressure at 2 months (145/97 +/- 20/15 mmHg, P < 0.01). During monitoring, blood pressure was normalized (systolic < 140 mmHg or diastolic < 90 mmHg) in one-third of the patients and insufficient compliance was unmasked in another 20%. When analysed according to tertiles of compliance, patients with the lowest compliance exhibited significantly higher achieved diastolic blood pressures (P = 0.04). In 30 patients, compliance was monitored up to 4 months and drug therapy was adapted whenever necessary. In these patients, a further significant decrease in blood pressure was obtained (from 150/100 +/- 18/15 to 143/94 +/- 22/11 mmHg, P = 0.04/0.02). CONCLUSIONS: These results suggest that objective monitoring of compliance using electronic devices may be a useful step in the management of patients with refractory hypertension, as it enables physicians to take rational decisions based on reliable and objective data of drug compliance and hence to improve blood pressure control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The level of information provided by ink evidence to the criminal and civil justice system is limited. The limitations arise from the weakness of the interpretative framework currently used, as proposed in the ASTM 1422-05 and 1789-04 on ink analysis. It is proposed to use the likelihood ratio from the Bayes theorem to interpret ink evidence. Unfortunately, when considering the analytical practices, as defined in the ASTM standards on ink analysis, it appears that current ink analytical practices do not allow for the level of reproducibility and accuracy required by a probabilistic framework. Such framework relies on the evaluation of the statistics of the ink characteristics using an ink reference database and the objective measurement of similarities between ink samples. A complete research programme was designed to (a) develop a standard methodology for analysing ink samples in a more reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in a forensic context. This report focuses on the first of the three stages. A calibration process, based on a standard dye ladder, is proposed to improve the reproducibility of ink analysis by HPTLC, when these inks are analysed at different times and/or by different examiners. The impact of this process on the variability between the repetitive analyses of ink samples in various conditions is studied. The results show significant improvements in the reproducibility of ink analysis compared to traditional calibration methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

S’ha dissenyat un Laboratori Virtual d’Equips Electrònics per múltiples aplicacions específiques com a reforç docent en l’àrea de l’electrònica VERiLAB (Virtual ElectRonic LABoratory) i, a més, s’han dissenyat un conjunt de 9 pràctiques guiades per treure el màxim rendiment al laboratori virtual. El laboratori Virtual és una potent eina de treball per aplicacions docents com a programari d’iniciació a la utilització d’equips electrònics bàsics que podem trobar a qualsevol laboratori d’electrònica. Aquesta eina permet augmentar el nombre d’hores de treball pràctic fora del laboratori. La primera versió d’aquest programari es va dissenyar a l’any 2004 a la Universitat de Barcelona amb el software LabVIEW_7, el qual permet obtenir un fitxer executable amb el qual els alumnes poden treballar fora del laboratori. D’aquesta forma els alumnes únicament necessiten un ordinador per a poder fer les pràctiques. La primera versió del laboratori disposava d’un generador de funcions, un oscil·loscopi i un analitzador d’espectres com a equips electrònics, i a més a més incorporava un mòdul de filtres i un motor DC per treballar amb els equips. La versió 2 del Laboratori Virtual es va desenvolupar amb aquest projecte MQD i es va introduir una font d’alimentació, un multímetre de sobre taula i un portàtil com a equips electrònics. Es van crear també diferents mòduls de sistemes electrònics: filtres analògics, configuracions bàsiques basades en l’amplificador operacional, l’amplificador operacional no ideal i un circuit de rectificació d’ona completa. Aquests mòduls han premés ampliar el camp d’aplicació del Laboratori Virtual a diferents assignatures de l’àrea de l’electrònica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the recent years most libraries have focused on mass digitization programs and keeping electronic born documents, showing and organizing them in a repository. While those repositories have evolved to a much more manageable systems focusing on the user expectations and introducing web 2.0 tools, digital preservation is still in the to-do list of most of them. There is quite a lot of studies focused on preservation and some complex models exist, unfortunately, very few practical systems are running and its quite difficult for a library to get involved in a solution already tested by others. The CBUC (Consortium of University Catalan Libraries) runs TDX, an ETD repository now keeping more than 10.000 full text thesis from any of the 12 university members. After 10 years running TDX a solid preservation system was needed to ensure every thesis would be kept as it was regardless what happens to the repository. The perfect solution was found in the MetaArchive cooperative, this is the effort of many insitutions to keep a copy of each other content through a newtwork using the LOCKSS software as a mechanism to keep track of any change. The presentation will shortly introduce what TDX and MetaArchive is but will, in a practical way, show how the LOCKSS network for presrervation works. Finally a summary of the benefits of the overall experience will be shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Forensic examinations of ink have been performed since the beginning of the 20th century. Since the 1960s, the International Ink Library, maintained by the United States Secret Service, has supported those analyses. Until 2009, the search and identification of inks were essentially performed manually. This paper describes the results of a project designed to improve ink samples' analytical and search processes. The project focused on the development of improved standardization procedures to ensure the best possible reproducibility between analyses run on different HPTLC plates. The successful implementation of this new calibration method enabled the development of mathematical algorithms and of a software package to complement the existing ink library.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resume : L'utilisation de l'encre comme indice en sciences forensiques est décrite et encadrée par une littérature abondante, comprenant entre autres deux standards de l'American Society for Testing and Materials (ASTM). La grande majorité de cette littérature se préoccupe de l'analyse des caractéristiques physiques ou chimiques des encres. Les standards ASTM proposent quelques principes de base qui concernent la comparaison et l'interprétation de la valeur d'indice des encres en sciences forensiques. L'étude de cette littérature et plus particulièrement des standards ASTM, en ayant a l'esprit les développements intervenus dans le domaine de l'interprétation de l'indice forensique, montre qu'il existe un potentiel certain pour l'amélioration de l'utilisation de l'indice encre et de son impact dans l'enquête criminelle. Cette thèse propose d'interpréter l'indice encre en se basant sur le cadre défini par le théorème de Bayes. Cette proposition a nécessité le développement d'un système d'assurance qualité pour l'analyse et la comparaison d'échantillons d'encre. Ce système d'assurance qualité tire parti d'un cadre théorique nouvellement défini. La méthodologie qui est proposée dans ce travail a été testée de manière compréhensive, en tirant parti d'un set de données spécialement créer pour l'occasion et d'outils importés de la biométrie. Cette recherche répond de manière convaincante à un problème concret généralement rencontré en sciences forensiques. L'information fournie par le criminaliste, lors de l'examen de traces, est souvent bridée, car celui-ci essaie de répondre à la mauvaise question. L'utilisation d'un cadre théorique explicite qui définit et formalise le goal de l'examen criminaliste, permet de déterminer les besoins technologiques et en matière de données. Le développement de cette technologie et la collection des données pertinentes peut être justifiées économiquement et achevée de manière scientifique. Abstract : The contribution of ink evidence to forensic science is described and supported by an abundant literature and by two standards from the American Society for Testing and Materials (ASTM). The vast majority of the available literature is concerned with the physical and chemical analysis of ink evidence. The relevant ASTM standards mention some principles regarding the comparison of pairs of ink samples and the evaluation of their evidential value. The review of this literature and, more specifically, of the ASTM standards in the light of recent developments in the interpretation of forensic evidence has shown some potential improvements, which would maximise the benefits of the use of ink evidence in forensic science. This thesis proposes to interpret ink evidence using the widely accepted and recommended Bayesian theorem. This proposition has required the development of a new quality assurance process for the analysis and comparison of ink samples, as well as of the definition of a theoretical framework for ink evidence. The proposed technology has been extensively tested using a large dataset of ink samples and state of the art tools, commonly used in biometry. Overall, this research successfully answers to a concrete problem generally encountered in forensic science, where scientists tend to self-limit the usefulness of the information that is present in various types of evidence, by trying to answer to the wrong questions. The declaration of an explicit framework, which defines and formalises their goals and expected contributions to the criminal and civil justice system, enables the determination of their needs in terms of technology and data. The development of this technology and the collection of the data is then justified economically, structured scientifically and can be proceeded efficiently.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Comparison of doxorubicin uptake, leakage and spatial regional blood flow, and drug distribution was made for antegrade, retrograde, combined antegrade and retrograde isolated lung perfusion, and pulmonary artery infusion by endovascular inflow occlusion (blood flow occlusion), as opposed to intravenous administration in a porcine model. METHODS: White pigs underwent single-pass lung perfusion with doxorubicin (320 mug/mL), labeled 99mTc-microspheres, and Indian ink. Visual assessment of the ink distribution and perfusion scintigraphy of the perfused lung was performed. 99mTc activity and doxorubicin levels were measured by gamma counting and high-performance liquid chromatography on 15 tissue samples from each perfused lung at predetermined localizations. RESULTS: Overall doxorubicin uptake in the perfused lung was significantly higher (P = .001) and the plasma concentration was significantly lower (P < .0001) after all isolated lung perfusion techniques, compared with intravenous administration, without differences between them. Pulmonary artery infusion (blood flow occlusion) showed an equally high doxorubicin uptake in the perfused lung but a higher systemic leakage than surgical isolated lung perfusion (P < .0001). The geometric coefficients of variation of the doxorubicin lung tissue levels were 175%, 279%, 226%, and 151% for antegrade, retrograde, combined antegrade and retrograde isolated lung perfusion, and pulmonary artery infusion by endovascular inflow occlusion (blood flow occlusion), respectively, compared with 51% for intravenous administration (P = .09). 99mTc activity measurements of the samples paralleled the doxorubicin level measurements, indicating a trend to a more heterogeneous spatial regional blood flow and drug distribution after isolated lung perfusion and blood flow occlusion compared with intravenous administration. CONCLUSIONS: Cytostatic lung perfusion results in a high overall doxorubicin uptake, which is, however, heterogeneously distributed within the perfused lung.