952 resultados para direct current (dc) model
Resumo:
Results of axiswise measurements of the electrical conductivity (dc and ac) and dielectric constant of NH4H2PO4 confirm the occurrence of the recently suggested high‐temperature phase transition in this crystal (at 133 °C). The corresponding transition in ND4D2PO4 observed here for the first time takes place at 141.5 °C. The mechanism involved in these transitions and those associated with the electrical conduction and dielectric anomalies are explained on the basis of the motional effects of the ammonium ions in these crystals. Conductivity values for deuterated crystals give direct evidence for the predominance of protonic conduction throughout the entire range of temperatures studied (30–260 °C).
Resumo:
This paper presents the optimal design of a surface mounted permanent-magnet (PM) Brushless direct-current (BLDC) motor meant for spacecraft applications. The spacecraft applications requires the choice of a motor with high torque density, minimum cogging torque, better positional stability and high torque to inertia ratio. Performance of two types of machine configurations viz Slotted PMBLDC and Slotless PMBLDC with Halbach array are compared with the help of analytical and finite element (FE) methods. It is found that unlike a Slotted PMBLDC motor, the Slotless type with Halbach array develops zero cogging torque without reduction in the developed torque. Moreover, the machine being coreless provides high torque to inertia ratio and zero magnetic stiction
Resumo:
This master thesis presents a new technological combination of two environmentally friendly sources of energy in order to provide DHW, and space heating. Solar energy is used for space heating, and DHW production using PV modules which supply direct current directly to electrical heating elements inside a water storage tank. On the other hand a GSHP system as another source of renewable energy provides heat in the water storage tank of the system in order to provide DHW and space heating. These two sources of renewable energy have been combined in this case-study in order to obtain a more efficient system, which will reduce the amount of electricity consumed by the GSHP system.The key aim of this study is to make simulations, and calculations of the amount ofelectrical energy that can be expected to be produced by a certain amount of PV modules that are already assembled on a house in Vantaa, southern Finland. This energy is then intended to be used as a complement to produce hot water in the heating system of the house beside the original GSHP system. Thus the amount of electrical energy purchased from the grid should be reduced and the compressor in the GSHP would need fewer starts which would reduce the heating cost of the GSHP system for space heating and providing hot water.The produced energy by the PV arrays in three different circuits will be charged directly to three electrical heating elements in the water storage tank of the existing system to satisfy the demand of the heating elements. The excess energy can be used to heat the water in the water storage tank to some extent which leads to a reduction of electricity consumption by the different components of the GSHP system.To increase the efficiency of the existing hybrid system, optimization of different PV configurations have been accomplished, and the results are compared. Optimization of the arrays in southern and western walls shows a DC power increase of 298 kWh/year compared with the existing PV configurations. Comparing the results from the optimization of the arrays on the western roof if the intention is to feed AC power to the components of the GSHP system shows a yearly AC power production of 1,646 kWh.This is with the consideration of no overproduction by the PV modules during the summer months. This means the optimized PV systems will be able to cover a larger part of summer demand compared with the existing system.
Resumo:
In this paper, self-synchronization of four non-ideal exciters is examined via numerical simulation. The mathematical model consists of four unbalanced direct Current motors with limited power supply mounted on a flexible Structural frame support. (c) 2004 Elsevier B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
We apply the Bogoliubov Averaging Method to the study of the vibrations of an elastic foundation, forced by a Non-ideal energy source. The considered model consists of a portal plane frame with quadratic nonlinearities, with internal resonance 1:2, supporting a direct current motor with limited power. The non-ideal excitation is in primary resonance in the order of one-half with the second mode frequency. The results of the averaging method, plotted in time evolution curve and phase diagrams are compared to those obtained by numerically integrating of the original differential equations. The presence of the saturation phenomenon is verified by analytical procedures.
Resumo:
In this work, the dynamic behavior of self-synchronization and synchronization through mechanical interactions between the nonlinear self-excited oscillating system and two non-ideal sources are examined by numerical simulations. The physical model of the system vibrating consists of a non-linear spring of Duffing type and a nonlinear damping described by Rayleigh's term. This system is additional forced by two unbalanced identical direct current motors with limited power (non-ideal excitations). The present work mathematically implements the parametric excitation described by two periodically changing stiffness of Mathieu type that are switched on/off. Copyright © 2005 by ASME.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Física - IGCE
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Mechanismen der zentralen und der peripheren Toleranz schützen den Körper vor Immunreaktionen gegen körpereigenes Gewebe oder gegen harmlose Umweltantigene. An der Aufrechterhaltung der peripheren Toleranz sind tolerogene Dendritische Zellen (DC) beteiligt. Tolerogene DC können in vitro u.a. mit Hilfe von immunsuppressiven und antiinflammatorischen Substanzen, aber auch durch virale Transduktionen, die zur Denovo- oder Überexpression toleranzassoziierter Moleküle führen, generiert werden. rnDa die Wirkung einiger immunmodulatorischer Substanzen über den intrazellulären sekundären Botenstoff cAMP vermittelt wird, sollte getestet werden, welchen Einfluss eine direkte Erhöhung des intrazellulären cAMP-Niveaus mittels Dibutyryl-cyclo-Adenosin-3´,5´-Mono-Phoshat (db-cAMP) auf die phänotypischen und funktionellen Eigenschaften von BM-DC („bone marrow derived dendritic cells“) hat.rnIm Vergleich zu unbehandelten BM-DC wiesen db-cAMP-DC ein vermindertes T-Zell-Stimulierungs-potenzial auf. Dieses verminderte T-Zell-Stimulierungspotenzial wird teilweise über die Proteinkinase A, nicht aber über Cyclooxygenase-2 (Cox-2) vermittelt. rnAnhand der FACS-Analyse mit DC- und MDSC- („myeloid derived suppressor cells“) spezifischen Markern konnte gezeigt werden, dass es sich bei den db-cAMP-DC um CD11c-positive DC mit einer vergleichsweise niedrigen Expression von MHCII und kostimulatorischen Oberflächenmolekülen handelt. Des Weiteren zeigte sich, dass sie verglichen mit BM-DC eine vermehrte mRNA-Expression der koinhibitorischen Moleküle B7-H1 und LIGHT und der toleranzassoziierten Moleküle FcγRIIB, HO-1 und Cox-2 aufweisen. Mittels ELISA konnte eine gesteigerte Expression der HO-1- und eine moderat gesteigerte PGE2-Synthese beobachtet werden. PGE2 wird mit Hilfe der Cox-2 aus Arachidonsäure gebildet.rnIm Gegensatz zu BM-DC wiesen db-cAMP-DC in beiden Reifungsstadien ein verändertes Zytokinprofil auf: Auf mRNA-Ebene zeigte sich, dass db-cAMP-DC verglichen mit BM-DC vermehrt IL-1RA und IL-10 exprimieren. Dieser Unterschied konnte für IL-10 auch mittels ELISA bestätigt werden. In den Kulturüberständen der stimulierten db-cAMP-DC konnte, im Gegensatz zu denen stimulierter BM-DC, kaum bioaktives IL-12 nachgewiesen werden. rnDb-cAMP-DC induzierten des Weiteren in kokultivierten allogenen T-Zellen ein differenzielles Zytokinprofil: Sie förderten die INFγ- und IL-17-Sezernierung durch T-Zellen, während die IL-5-Sezernierung geringer war, wenn T-Zellen mit stimulierten db-cAMP-DC kokultiviert wurden. Db-cAMP-DC hatten hingegen keinen Einfluss auf die IL-10-Produktion. Außerdem führte eine Kokultur der db-cAMP-DC mit allogenen T-Zellen nicht zu einer gesteigerten Induktion von FoxP3+ Treg. rnIn einem zweiten Ansatz sollte getestet werden ob es möglich ist die murine DC-Linie SP37A3 lentiviral mit dem toleranzassoziierten Oberflächenprotein B7-H3 zu transduzieren. Dies ist von Interesse, da die SP37A3-Zellen einige Vorteile gegenüber BM-DC aufweisen, wie z.B. ihren homogeneren Phänotyp und die Möglichkeit sie in einer Expansionskultur zu halten.rnEs konnte gezeigt werden, dass SP37A3-Zellen als Modell für myeloide DC für die Transduktion mit lentiviralen Partikeln geeignet sind. Hierbei zeigte es sich aber, dass darauf geachtet werden muss, mit konzentriertem Virus zu arbeiten und dass die Reportergen-Expression der Zielzellen über mehr als 3 Tage (mindestens 7 Tage) untersucht werden muss. Nur so kann eine eventuell auftretende Pseudotransduktion erkannt und verhindert werden. Ab einer MOI („multiplicity of infection“) von 50 konnte in SP37A3-Zellen eine Transgen-Expression nachgewiesen werden.rn