982 resultados para ddc:620
Resumo:
The oxovanadium(IV) complexes [VO(acac)(2)(Hpz)].HC(pz)(3) 1.HC(pz)(3) (acac= acetylacetonate, Hpz = pyrazole, pz = pyrazoly1) and [VOCl2{HOCH2C(pz)(3)}] 2 were obtained from reaction of [VO(acac)(2)] with hydrotris(1-pyrazolyl)methane or of VCl(3)with 2,2,2-tris(1-pyrazolyl)ethanol. The compounds were characterized by elemental analysis, IR, Far-IR and EPR spectroscopies, FAB or ESI mass-spectrometry and, for 1, by single crystal X-ray diffraction analysis. 1 and 2 exhibit catalytic activity for the oxidation of cyclohexane to the cyclohexanol and cyclohexanone mixture in homogeneous system (TONS up to 1100) under mild conditions (NCMe, 24h, room temperature) using benzoyl peroxide (BPO), tert-butyl hydroperoxide (TBHP), m-chloroperoxybenzoic acid (mCPBA), hydrogen peroxide or the urea-hydrogen peroxide adduct (UHP) as oxidants. 1 and 2 were also immobilized on a polydimethylsiloxane membrane (1-PDMS or 2-PDMS) and the systems acted as supported catalysts for the cyclohexane oxidation using the above oxidants (TONs up to 620). The best results were obtained with mCPBA or BP0 as oxidant. The effects of various parameters, such as the amount of catalyst, nitric acid, reaction time, type of oxidant and oxidant-to-catalyst molar ratio, were investigated, for both homogeneous and supported systems. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Este trabalho surgiu no âmbito da Tese de Mestrado em Engenharia Química - Ramo Optimização Energética na Indústria Química, aliando a necessidade da Empresa Monteiro Ribas – Indústrias, S.A. em resolver alguns problemas relacionados com as estufas da unidade J da fábrica de revestimentos. Outro dos objectivos era propor melhorias de eficiência energética neste sector da empresa. Para tal, foi necessário fazer um levantamento energético de toda a unidade, o que permitiu verificar que as estufas de secagem (Recobrimento 1 e 2) seriam o principal objecto de estudo. O levantamento energético da empresa permitiu conhecer o seu consumo anual de energia de 697,9 tep, o que a classifica, segundo o Decreto-lei nº 71 de 15 de Abril de 2008, como Consumidora Intensiva de Energia (CIE). Além disso, as situações que devem ser alvo de melhoria são: a rede de termofluido, que apresenta válvulas sem isolamento, o sistema de iluminação, que não é o mais eficiente e a rede de distribuição de ar comprimido, que não tem a estrutura mais adequada. Desta forma sugere-se que a rede de distribuição de termofluido passe a ter válvulas isoladas com lã de rocha, o investimento total é de 2.481,56 €, mas a poupança pode ser de 21.145,14 €/ano, com o período de retorno de 0,12 anos. No sistema de iluminação propõe-se a substituição dos balastros normais por electrónicos, o investimento total é de 13.873,74 €, mas a poupança é de 2.620,26 €/ano, com período de retorno de 5 anos. No processo de secagem das linhas de recobrimento mediram-se temperaturas de todos os seus componentes, velocidades de ar o que permitiu conhecer a distribuição do calor fornecido pelo termofluido. No Recobrimento 1, o ar recebe entre 39 a 51% do calor total, a tela recebe cerca de 25% e na terceira estufa este é apenas de 6%. Nesta linha as perdas de calor por radiação oscilam entre 6 e 11% enquanto as perdas por convecção representam cerca de 17 a 44%. Como o calor que a tela recebe é muito inferior ao calor recebido pelo ar no Recobrimento 1, propõe-se uma redução do caudal de ar que entra na estufa, o que conduzirá certamente à poupança de energia térmica. No Recobrimento 2 o calor fornecido ao ar representa cerca de 51 a 77% do calor total e o cedido à tela oscila entre 2 e 3%. As perdas de calor por convecção oscilam entre 12 e 26%, enquanto que as perdas por radiação têm valores entre 4 e 8%. No que diz respeito ao calor necessário para evaporar os solventes este oscila entre os 4 e 13%. Os balanços de massa e energia realizados ao processo de secagem permitiram ainda determinar o rendimento das 3 estufas do Recobrimento 1, com 36, 47 e 24% paras as estufa 1, 2 e 3, respectivamente. No Recobrimento 2 os valores de rendimento foram superiores, tendo-se obtido valores próximos dos 41, 81 e 88%, para as estufas 1, 2 e 3, respectivamente. Face aos resultados obtidos propõem-se a reengenharia do processo introduzindo permutadores compactos para aquecer o ar antes de este entrar nas estufas. O estudo desta alteração foi apenas realizado para a estufa 1 do Recobrimento 1, tendo-se obtido uma área de transferência de calor de 6,80 m2, um investimento associado de 8.867,81 €. e uma poupança de 708,88 €/ano, com um período de retorno do investimento de 13 anos. Outra sugestão consiste na recirculação de parte do ar de saída (5%), que conduz à poupança de 158,02 €/ano. Estes valores, pouco significativos, não estimulam a adopção das referidas sugestões.
Resumo:
CYCLOTech is a high-tech Project, related with an innovative method for direct production of a radioactive pharmaceutical, used in excess of 85% of 35 Million Nuclear Medicine procedures done yearly, worldwide, representing globally more than 3 Billion Euros. The CYCLOTech team has developed an innovative proprietary methodology based on the use of Cyclotron Centers, formally identified as the Clients (actually, there are around 450 of this Centers in function worldwide), to directly produce and deliver the radiopharmaceutical to the final users, at the Hospitals and other Health Institutions (estimating at around 25.000, worldwide). The investment still need to finish Research and Technological Development (RTD), Industrial, Regulatory and Intellectual Property Rights (IPR) issues and allow the introduction in the Market is 4,35 M€, with a Payback of 3 years, with an Investment Return Rate (IRR) of 81,7% and a Net Present Value (NPV) of 60.620.525€ (in 2020).
Resumo:
OBJETIVO: Estimar a prevalência da morbidade materna extremamente grave e identificar procedimentos hospitalares associados. MÉTODOS: Foram utilizados dados do Sistema de Informação Hospitalar fornecidos pela Secretaria de Saúde de Juiz de Fora, MG, de 2006 a 2007. Foram selecionadas as internações para procedimentos obstétricos (n = 8.620 mulheres) cujo diagnóstico principal compreendia todo o capítulo XV, gravidez, parto e puerpério, da Classificação Estatística Internacional de Doenças e Problemas Relacionados à Saúde, Décima Revisão. Foram identificados os códigos dos procedimentos realizados, procedimentos especiais e atos profissionais que pudessem contemplar o critério de morbidade materna extremamente grave da Organização Mundial da Saúde e outros procedimentos não habitualmente utilizados no período gravídico-puerperal. A análise de regressão logística foi utilizada para identificar associações entre desfecho e variáveis selecionadas. RESULTADOS: A prevalência de morbidade materna foi 37,8/1000 mulheres e a proporção de mortalidade foi 12/100.000 mulheres. O tempo de internação > 4 dias foi 13 vezes mais alto entre as mulheres que apresentaram alguma morbidade. Após análise ajustada, os fatores preditores de morbidade materna extremamente grave foram: tempo de internação, número de internações e filhos natimortos, e os procedimentos/condições mais frequentes foram a transfusão de hemoderivados (15,7/1.000), "permanência a maior" (9,5/1.000) e pré-eclâmpsia grave/eclâmpsia (8,2/1.000). CONCLUSÕES: Foi alta a prevalência de morbidade materna extremamente grave, associada principalmente às internações e variáveis relacionadas ao recém-nascido. O critério para identificação dos casos e o uso do Sistema de Informações Hospitalares mostraram-se úteis para a vigilância da morbimortalidade materna e para ampliar o conhecimento sobre os aspectos que a envolvem, contribuindo para a melhoria na qualidade da assistência à mulher no período gravídico-puerperal.
Resumo:
Não existe uma definição única de processo de memória de longo prazo. Esse processo é geralmente definido como uma série que possui um correlograma decaindo lentamente ou um espectro infinito de frequência zero. Também se refere que uma série com tal propriedade é caracterizada pela dependência a longo prazo e por não periódicos ciclos longos, ou que essa característica descreve a estrutura de correlação de uma série de longos desfasamentos ou que é convencionalmente expressa em termos do declínio da lei-potência da função auto-covariância. O interesse crescente da investigação internacional no aprofundamento do tema é justificado pela procura de um melhor entendimento da natureza dinâmica das séries temporais dos preços dos ativos financeiros. Em primeiro lugar, a falta de consistência entre os resultados reclama novos estudos e a utilização de várias metodologias complementares. Em segundo lugar, a confirmação de processos de memória longa tem implicações relevantes ao nível da (1) modelação teórica e econométrica (i.e., dos modelos martingale de preços e das regras técnicas de negociação), (2) dos testes estatísticos aos modelos de equilíbrio e avaliação, (3) das decisões ótimas de consumo / poupança e de portefólio e (4) da medição de eficiência e racionalidade. Em terceiro lugar, ainda permanecem questões científicas empíricas sobre a identificação do modelo geral teórico de mercado mais adequado para modelar a difusão das séries. Em quarto lugar, aos reguladores e gestores de risco importa saber se existem mercados persistentes e, por isso, ineficientes, que, portanto, possam produzir retornos anormais. O objetivo do trabalho de investigação da dissertação é duplo. Por um lado, pretende proporcionar conhecimento adicional para o debate da memória de longo prazo, debruçando-se sobre o comportamento das séries diárias de retornos dos principais índices acionistas da EURONEXT. Por outro lado, pretende contribuir para o aperfeiçoamento do capital asset pricing model CAPM, considerando uma medida de risco alternativa capaz de ultrapassar os constrangimentos da hipótese de mercado eficiente EMH na presença de séries financeiras com processos sem incrementos independentes e identicamente distribuídos (i.i.d.). O estudo empírico indica a possibilidade de utilização alternativa das obrigações do tesouro (OT’s) com maturidade de longo prazo no cálculo dos retornos do mercado, dado que o seu comportamento nos mercados de dívida soberana reflete a confiança dos investidores nas condições financeiras dos Estados e mede a forma como avaliam as respetiva economias com base no desempenho da generalidade dos seus ativos. Embora o modelo de difusão de preços definido pelo movimento Browniano geométrico gBm alegue proporcionar um bom ajustamento das séries temporais financeiras, os seus pressupostos de normalidade, estacionariedade e independência das inovações residuais são adulterados pelos dados empíricos analisados. Por isso, na procura de evidências sobre a propriedade de memória longa nos mercados recorre-se à rescaled-range analysis R/S e à detrended fluctuation analysis DFA, sob abordagem do movimento Browniano fracionário fBm, para estimar o expoente Hurst H em relação às séries de dados completas e para calcular o expoente Hurst “local” H t em janelas móveis. Complementarmente, são realizados testes estatísticos de hipóteses através do rescaled-range tests R/S , do modified rescaled-range test M - R/S e do fractional differencing test GPH. Em termos de uma conclusão única a partir de todos os métodos sobre a natureza da dependência para o mercado acionista em geral, os resultados empíricos são inconclusivos. Isso quer dizer que o grau de memória de longo prazo e, assim, qualquer classificação, depende de cada mercado particular. No entanto, os resultados gerais maioritariamente positivos suportam a presença de memória longa, sob a forma de persistência, nos retornos acionistas da Bélgica, Holanda e Portugal. Isto sugere que estes mercados estão mais sujeitos a maior previsibilidade (“efeito José”), mas também a tendências que podem ser inesperadamente interrompidas por descontinuidades (“efeito Noé”), e, por isso, tendem a ser mais arriscados para negociar. Apesar da evidência de dinâmica fractal ter suporte estatístico fraco, em sintonia com a maior parte dos estudos internacionais, refuta a hipótese de passeio aleatório com incrementos i.i.d., que é a base da EMH na sua forma fraca. Atendendo a isso, propõem-se contributos para aperfeiçoamento do CAPM, através da proposta de uma nova fractal capital market line FCML e de uma nova fractal security market line FSML. A nova proposta sugere que o elemento de risco (para o mercado e para um ativo) seja dado pelo expoente H de Hurst para desfasamentos de longo prazo dos retornos acionistas. O expoente H mede o grau de memória de longo prazo nos índices acionistas, quer quando as séries de retornos seguem um processo i.i.d. não correlacionado, descrito pelo gBm(em que H = 0,5 , confirmando- se a EMH e adequando-se o CAPM), quer quando seguem um processo com dependência estatística, descrito pelo fBm(em que H é diferente de 0,5, rejeitando-se a EMH e desadequando-se o CAPM). A vantagem da FCML e da FSML é que a medida de memória de longo prazo, definida por H, é a referência adequada para traduzir o risco em modelos que possam ser aplicados a séries de dados que sigam processos i.i.d. e processos com dependência não linear. Então, estas formulações contemplam a EMH como um caso particular possível.
Resumo:
Historical buildings are important fingerprints of the history and culture of a region and its communities. Climatic and environmental conditions are often very severe for construction materials, namely in presence of high humidity or in direct contact with water and salts. However, some historical buildings have in our days a very good condition, probably due to careful construction and/or accurate materials selection and to a specific technology. The knowledge of old mortars composition has a fundamental role on the preservation of cultural heritage, allowing information about the used materials, their performance in their specific environment, conducting to adequate and compatible materials to conservation purposes. This article presents two case studies of historical buildings with important defence functions in Lisbon coast, in which ancient lime mortars where used under severe seaside environmental actions. Mortar samples from these two case studies are characterized and the relationship of their composition with the good performance and high durability observed is discussed.
Resumo:
Foram cultivadas fezes de 620 indivíduos para a pesquisa de amebas de vida livre, sendo 514 pacientes do Hospital Universitário Pedro Ernesto (UERJ) e 106 crianças e adultos de um orfanato. Foram positivas 70 amostras (11,2%) sendo 55 provenientes de pacientes do HU-UERJ e 15 de internos do orfanato. Foram isoladas 60 amostras de Acanthamoeba, 6 de Vahlkampfia, 5 de Hartmannella e 1 Echinamoeba. Alguns indivíduos tiveram cultura de fezes repetidamente positiva para Acanthamoeba durante dois meses de observação. Das amostras de Acanthamoeba isoladas, 28 foram inoculadas em camundongos por via intranasal, tendo sido reisoladas 16 (57,1%) amostras à partir de cérebro e (ou) pulmões dos animais. O estudo histopatológico demonstrou processo inflamatório agudo com presença de polimorfonucleares e amebas no cérebro e pulmões de alguns animais. O encontro de amostras patogênicas em fezes humanas reforça a hipótese do eventual desenvolvimento, em indivíduos portadores, de meningoencefalite amebiana granulomatosa, como infecção oportunística de origem endógena.
Resumo:
Basidiomycete strains synthesize several types of beta-D-glucans, which play a major role in the medicinal properties of mushrooms. Therefore, the specific quantification of these beta-D-glucans in mushroom strains is of great biochemical importance. Because published assay methods for these beta-D-glucans present some disadvantages, a novel colorimetric assay method for beta-D-glucan with alcian blue dye was developed. The complex formation was detected by following the decrease in absorbance in the range of 620 nm and by hypsochromic shift from 620 to 606 nm (similar to 14 nm) in UV-Vis spectrophotometer. Analysis of variance was used for optimization of the slope of the calibration curve by using the assay mixture containing 0.017% (w/v) alcian blue in 2% (v/v) acetic acid at pH 3.0. The high-throughput colorimetric assay method on microtiter plates was used for quantification of beta-D-glucans in the range of 0-0.8 mu g, with a slope of 44.15 x 10(-2) and a limit of detection of 0.017 mu g/well. Recovery experiments were carried out by using a sample of Hericium erinaceus, which exhibited a recovery of 95.8% for beta-1,3-D-glucan. The present assay method exhibited a 10-fold higher sensitivity and a 59-fold lower limit of detection compared with the published method with congo red beta-D-glucans of several mushrooms strains were isolated from fruiting bodies and mycelia, and they were quantified by this assay method. This assay method is fast, specific, simple, and it can be used to quantify beta-D-glucans from other biological sources. (C) 2015 American Institute of Chemical Engineers
Resumo:
Comunicação apresentada no 8º Congresso Nacional de Administração Pública - Desafios e Soluções, em Carcavelos de 21 a 22 de Novembro de 2011.
Resumo:
RESUMO: A síndrome de apneia hipopneia obstrutiva do sono (SAHOS), pela sua prevalência e consequências clínicas, nomeadamente as de natureza cardiovascular, é actualmente considerada um problema de saúde pública. A patogénese da doença cardiovascular na SAHOS não está ainda completamente estabelecida, mas parece ser multifactorial, envolvendo diversos mecanismos que incluem a hiperactividade do sistema nervoso simpático, a disfunção endotelial, a activação selectiva de vias inflamatórias, o stress oxidativo vascular e a disfunção metabólica. A terapêutica com CPAP diminui grandemente o risco de eventos cardiovasculares fatais e não fatais. O CPAP está inequivocamente indicado para o tratamento da SAHOS grave, no entanto, não é consensual a sua utilização nos doentes com SAHOS ligeira/moderada sem hipersonolência diurna associada. Tendo em conta este facto, é fundamental que as indicações terapêuticas do CPAP nestes doentes tenham uma relação custo-eficácia favorável. Assim, dado o posicionamento do estado da arte relativamente ao estudo da disfunção endotelial e da activação do sistema nervoso simpático estar centrada maioritariamente nos doentes com SAHOS grave, desenvolvemos este estudo com o objectivo de comparar os níveis plasmáticos de nitratos, os níveis de catecolaminas urinárias e os valores de pressão arterial nos doentes com SAHOS ligeira/moderada e grave e avaliar a resposta destes parâmetros ao tratamento com CPAP durante um mês. Realizámos um estudo prospectivo, incidindo sobre uma população de 67 doentes do sexo masculino com o diagnóstico de SAHOS (36 com SAHOS ligeira/moderada e 31com SAHOS grave). O protocolo consistia em 3 visitas: antes da terapêutica com CPAP (visita 1), uma semana após CPAP (visita 2) e um mês após CPAP (visita 3). Nas visitas 1 e 3, eram submetidos a três colheitas de sangue às 11 pm, 4 am e 7 am para doseamento dos nitratos plasmáticos e na visita 2 apenas às 7 am. Nas visitas 1 e 3 era também efectuada uma colheita de urina de 24 horas para o doseamento das catecolaminas urinárias e eram submetidos a uma monitorização ambulatória da pressão arterial de 24 horas (MAPA). Foi ainda estudado um grupo controlo de 30 indivíduos do sexo masculino não fumadores sem patologia conhecida e sem evidência de SAHOS. Antes da terapêutica com CPAP, verificou-se uma diminuição significativa dos níveis de nitratos ao longo da noite quer nos doentes com SAHOS ligeira/moderada, quer nos doentes com SAHOS grave. No entanto, esta redução diferia nos 2 grupos de doentes, sendo significativamente superior nos doentes com SAHOS grave (27,6±20,1% vs 16,5±18,5%; p<0,05). Após um mês de tratamento com CPAP, verificou-se um aumento significativo dos valores de nitratos plasmáticos apenas nos doentes com SAHOS grave, mantendo-se os níveis de nitratos elevados ao longo da noite, já não existindo o decréscimo desses valores ao longo da mesma. Os valores de noradrenalina basais eram significativamente superiores nos doentes com SAHOS grave comparativamente com os doentes com SAHOS ligeira/moderada (73,9±30,1μg/24h vs 48,5±19,91μg/24h; p<0,05). Após um mês de terapêutica com CPAP, apenas se verificou uma redução significativa nos valores da noradrenalina nos doentes com SAHOS grave (73,9±30,1μg/24h para 55,4±21,8 μg/24h; p<0,05). Os doentes com SAHOS grave apresentaram valores de pressão arterial mais elevados do que os doentes com SAHOS ligeira/moderada, nomeadamente no que diz respeito aos valores de pressão arterial média, sistólica média de 24 horas, diurna e nocturna e diastólica média de 24 horas, diurna e nocturna. Após um mês de terapêutica com CPAP, verificou-se uma redução significativa dos valores tensionais apenas nos doentescom SAHOS grave, para a pressão média (-2,32+5,0; p=0,005), para a sistólica média de 24 horas (-4,0+7,9mmHg; p=0,009), para a pressão sistólica diurna (-4,3+8,8mmHg; p=0,01), para a pressão sistólica nocturna (-5,1+9,0mmHg; p=0,005), para a pressão diastólica média de 24 horas (-2,7+5,8mmHg; p=0,016), para a pressão diastólica diurna (-3,2+6,3mmHg; p=0,009) e para a pressão diastólica nocturna (-2,5+7,0mmHg; p=0,04). Os níveis tensionais dos doentes com SAHOS grave após CPAP atingiram valores semelhantes aos dos doentes com SAHOS ligeira/moderada, relativamente a todos os parâmetros avaliados no MAPA. Este estudo demonstrou que antes do tratamento com CPAP, existe uma redução dos níveis de nitratos ao longo da noite não só nos doentes com SAHOS grave mas também nos doentes com SAHOS ligeira/moderada. No entanto, a terapêutica com CPAP leva a um aumento significativo dos valores de nitratos plasmáticos apenas nos doentes com SAHOS grave, mantendo-se os níveis de nitratos elevados ao longo da noite, já não existindo o decréscimo desses valores ao longo da mesma. O tratamento com CPAP durante um mês, apenas reduz os níveis de noradrenalina urinária e os valores de pressão arterial nos doentes com SAHOS grave.------------ ABSTRACT: In severe obstructive sleep apnea (OSA) reduced circulating nitrate, increased levels of urinary norepinephrine (U-NE) and changes in systemic blood pressure (BP) have been described and are reverted by Continuous Positive Airway Pressure (CPAP). However, the consequences of mild/moderate OSA on these parameters and the CPAP effect upon them are not well known. We aimed to: 1) compare the levels of plasma nitrate (NOx) and U-NE of mild/moderate and severe male OSA patients 2) compare BP in these patient groups; and 3) determine whether CPAP improves sympathetic dysfunction, nitrate deficiency and BP in these patients. This prospective study was carried out in 67 consecutive OSA patients (36 mild/moderate and 31 severe patients) and NOx (11 pm, 4 am, 7 am), 24-h U-NE and ambulatory blood pressure monitoring were obtained before and after 4 weeks of CPAP. Baseline: NOx levels showed a significant decrease (p<0.001) during the night in both groups of patients. The U-NE and BP were significantly higher in the severe group. Post CPAP: After one month of CPAP, there was a significant increase of NOx, a reduction of U-NE and BP only in severe patients. This study shows that in contrast to severe OSA patients, those with mild/moderate OSA, which have lower values of BP and U-NE at baseline, do not benefit from a 4 weeks CPAP treatment as measured by plasma nitrate, 24-h U-NE levels and BP.
Resumo:
Disturbances in mineral metabolism play a central role in the development of renal bone disease. In a 54-wk, randomized, open-label study, 119 hemodialysis patients were enrolled to compare the effects of sevelamer hydrochloride and calcium carbonate on bone. Biopsy-proven adynamic bone disease was the most frequent bone abnormality at baseline (59%). Serum phosphorus, calcium, and intact parathyroid hormone were well controlled in both groups, although calcium was consistently lower and intact parathyroid hormone higher among patients who were randomly assigned to sevelamer. Compared with baseline values, there were no changes in mineralization lag time or measures of bone turnover (e.g., activation frequency) after 1 yr in either group. Osteoid thickness significantly increased in both groups, but there was no significant difference between them. Bone formation rate per bone surface, however, significantly increased from baseline only in the sevelamer group (P = 0.019). In addition, of those with abnormal microarchitecture at baseline (i.e., trabecular separation), seven of 10 in the sevelamer group normalized after 1 yr compared with zero of three in the calcium group. In summary, sevelamer resulted in no statistically significant changes in bone turnover or mineralization compared with calcium carbonate, but bone formation increased and trabecular architecture improved with sevelamer. Further studies are required to assess whether these changes affect clinical outcomes, such as rates of fracture.
Resumo:
This research focuses on the influence of company sector and size on the level of utilization of Basic and Advanced Quality Tools. The paper starts with a literature review and then presents the methodology used for the survey. Based on the responses from 202 managers of Portuguese ISO 9001:2008 Quality Management System certified organizations, statistical tests were performed. Results show, with 95% confidence level, that industry and services have a similar proportion of use of Basic and Advanced Quality Tools. Concerning size, bigger companies show a higher trend to use Advanced Quality Tools than smaller ones. For Basic Quality Tools, there was no statistical significant difference at a 95% confidence level for different company sizes. The three basic Quality tools with higher utilization were Check sheets, Flow charts and Histograms (for Services) or Control Charts/ (for Industry), however 22% of the surveyed organizations reported not using Basic Quality Tools, which highlights a major improvement opportunity for these companies. Additional studies addressing motivations, benefits and barriers for Quality Tools application should be undertaken for further validation and understanding of these results.
Resumo:
Na abordagem da cicatrização de uma ferida cirúrgica deve equacionar-se a cicatrização por segunda intenção como uma alternativa válida, revelando excelentes resultados e claras vantagens após selecção adequada dos doentes. Os autores descrevem o caso de um doente do sexo masculino com 66 anos de idade, submetido a excisão de um carcinoma espinocelular da concha do pavilhão auricular direito e subsequente cicatrização por segunda intenção. Discutem-se algumas particularidades desta técnica revendo a literatura relevante.
Resumo:
O objetivo do trabalho foi verificar a prevalência de candidíase em transplantados renais. Foram avaliados os prontuários dos pacientes transplantados no Hospital das Clínicas de Ribeirão Preto de fevereiro de 1968 a fevereiro de 1995. Nesse período foram transplantados 620 pacientes. Destes, 87 apresentaram 107 episódios de candidíase. Locais mais acometidos: trato urinário com 55 episódios, trato respiratório com 28, e trato gastrointestinal com 16. O agente etiológico mais freqüente foi C. albicans com 65 casos seguido de C. tropicalis com 12 e C. glabrata com 11 casos. As infecções do trato urinário mostraram incidência maior (61,7%) nos primeiros 6 meses. A maioria se apresentou clínicamente como infecção bacteriana. No trato respiratório, as infecções foram caracterizadas por recuperação do agente no escarro. No trato gastrointestinal, 9/16 episódios foram esofágicos, com epigastralgia, dor retroesternal, às vezes acompanhados de candidíase oral ou odinofagia. Nos outros episódios o agente foi recuperado nas fezes com quadro clínico de gastroenterite. Nas infecções dos tratos urinário e respiratório, houve associação da candidíase com antibioticoterapia prévia (76% e 67% respectivamente), além de infecções bacterianas concomitantes (34% e 64% respectivamente). As infecções por Candida sp tiveram prevalência geral em torno de 14,5%. A localização predominante foi no trato urinário e, em seguida, nos tratos respiratório e gastrointestinal, apresentando alto índice de associação com antibioticoterapia prévia e infecções bacterianas.
Resumo:
O episódio reacional tipo 1 ou reação reversa é ocorrência inflamatória aguda que atinge a pele e nervos periféricos, encontrada em até 30% dos pacientes com hanseníase, sendo causa comum de incapacidade física. Fatores de risco associados incluem uso de poliquimioterapia e infecções virais. Neste estudo, foram avaliados 620 pacientes com hanseníase. Reação reversa foi diagnosticada em 121 (19,5%) casos, sendo mais freqüente nos indivíduos borderlines (48%). Início da poliquimioterapia foi considerado fator de risco para reação reversa, com 52% dos casos apresentando o primeiro episódio neste momento. Neurite foi documentada em 73% dos casos. A presença de vírus B ou C da hepatite foi documentada em 9% de 55 pacientes com reação reversa e em nenhum dos 57 pacientes sem reação (p = 0, 026; teste exato de Fisher), sugerindo possível papel destes agentes como fatores de risco para desenvolvimento de reação reversa na hanseníase.