1000 resultados para cromatografia de íons


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first paper in this series discussed the basic theory involved in supercritical fluid chromatography (SFC) and how the technique progressed from gas and liquid chromatography. The first SFC instruments were simple adaptations of the commercially available liquid chromatographs with packed columns followed by modifications in gas chromatographs using open tubular capillary columns. In this paper, the most important aspects regarding instrumentation are covered, including practical, simple, and the most important, inexpensive solutions to build a home-made SFC system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synthetic dyes were determined by high performance liquid chromatography in 76 samples of regular jelly and diet jelly powders, of several flavors produced by seven different manufacturers. Three sample of each product, from different batches, were analyzed. The same qualitative composition was observed for products of the same flavor from different manufacturers, but the quantitative composition varied markedly from one manufacturer to the other. There were no or few significant differences between batches from a given manufacturer, demonstrating good quality control in the use of these additives by the food industry. None of the samples exceeded the limit stipulated by Brazilian legislation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the aim of studying the interaction of fast electrons with solid surfaces we have developed an experimental set-up based on electron stimulated desorption (ESD) coupled to time-of-flight (TOF) mass spectrometry. Poly(methyl methacrylate) and poly(vynil chloride) samples have been irradiated by a pulsed electron beam of 1.2 keV and 0.18 µs FWHM. The results show that H+ is the main ionic species to desorb after electron bombardment. In addition, other ionic fragments were also observed and assigned. These results show the potentiality of this technique in the study of ESD of polymers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative GC-FID was evaluated for analysis of methylated copaiba oils, using trans-(-)-caryophyllene or methyl copalate as external standards. Analytical curves showed good linearity and reproducibility in terms of correlation coefficients (0.9992 and 0.996, respectively) and relative standard deviation (< 3%). Quantification of sesquiterpenes and diterpenic acids were performed with each standard, separately. When compared with the integrator response normalization, the standardization was statistically similar for the case of methyl copalate, but the response of trans-(-)-caryophyllene was statistically (P < 0.05) different. This method showed to be suitable for classification and quality control of commercial samples of the oils.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work reviews recent advances in the preparation of new reversed phase packing materials such as sterically protected, bidentate, hybrid organic-inorganic and monolithic phases and phases containing embedded polar groups. The bonding chemistry involved in the preparation of these phases as well as their advantages over conventional C8 and C18 reversed phases are discussed. Understanding the reasons behind the development of these newer column packings helps analysts select the best stationary phase for a given application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Procion Green HE-4BD is a reactive dye currently used in affinity purification, and commonly present as a contaminant in the final biological preparation. An assay method is described to determine trace amounts of the dye in the presence of human serum albumin(HSA) and leakage from agarose as affinity sorbent by cathodic stripping voltammetry. The proposed method is based on the reductive peak at -0.55V in B-R buffer pH 3 (E=0V and t= 240s), obtained when samples of HSA 2% (m/v) containing dye concentrations in sodium hydroxide pH 12 are submitted to a heating time of 330 min at 80 ºC. Linear calibration curves can be obtained for RG19 dye concentrations from 5x10-9 mol L-1 to 8 x10-8 mol L-1. The detection limit (3sigma) is 1x10-9 mol L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present work was to test the combination of non-esterified fatty acid (NEFA) isolation using fumed silicon dioxide with capillary gas-chromatography (C-GC) with splitless injection for the analysis of NEFAs in human plasma. Injection volume, solvent re-condensation and split purge flow-rate were the parameters evaluated for the analysis of fatty acid methyl esters by C-GC. The use of a solvent re-condensation technique, associated with 1.0 µL injection and a split purge flow rate of 80 mL/min resulted in satisfactory analysis of NEFAs. Fourteen fatty acids were identified in plasma samples, ranging from 2.03 to 184.0 µmol/L. The combination of both techniques proved useful for routine analyses of plasma NEFAs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The scope of this study encompasses an overview of the principles of unified chromatography as well as the principles of chromatographic techniques as applied to unified systems, which include gas chromatography, liquid chromatography, supercritical fluid chromatography, high temperature and high pressure liquid chromatography, micro-liquid chromatography, enhanced fluidity chromatography, and solvating gas chromatography. Theoretical considerations and individual instrumental parameters such as mobile phase, sample introduction system, columns, and detection system are also discussed. Future applications of this separation approach are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The demand for analytical methods suitable for accurate and reproducible determination of drug enantiomers has increased significantly in the last years. High-performance liquid chromatography (HPLC) using chiral stationary phases and capillary electrophoresis (CE) are the most important techniques used for this purpose. In this paper, the fundamental aspects of chiral separations using both techniques are presented. Some important aspects for the development of enantioselective methods, particularly for the analysis of drugs and metabolites in biological samples, are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

KBrO3 is registered by the FAO/OMS as a genotoxic and carcinogenic compound. In spite of this, KBrO3 is still employed by Brazilian bakeries. Nowadays ion exchange chromatography (IEC) is the most rapid and trustful method for BrO3- analysis. When at high concentrations, chloride ions can interfere in the BrO3- analysis, if the detection is performed by electrical conductivity. On the other hand, spectrophotometric detection, presented here is based on the absorption of BrO3- in the ultraviolet region (210 - 230 nm) where the absortion of chloride ions is very low, thus making possible the qualitative and quantitative analysis of BrO3- in flour improver samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plant extracts are usually complex mixtures which contain several molecules of different sizes with varied functional groups. Such extracts are a challenge to the chemist of natural products. Ion exchange chromatography in non-aqueous medium, used for separation of basic or acidic fractions from plant extracts, is an important unit operation in preparative scale separations. Anionic macroporous resin in non-aqueous medium was used with success in this study for separation of the acid fraction of Copaifera multijuga (Copaiba oil), rich in labdanic diterpenes and for the methanolic extract of Croton cajucara (acetyl aleuritoric acid).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solid phase extraction (SPE) in C18 disks has been optimized and validated for extraction of 5 organophosphorus (OP) pesticides in water. Extraction has been followed by separation and detection by gas chromatography/flame photometry. Excellent linearity was obtained for all compounds (r greater than 0.99), with CVs between 1.0-6.9%, recoveries between 73-95% and quantification limits between 2.5-5.0 µg L-1. Samples from Furnas dam were analyzed monthly during one year and 10% showed OP pesticide residues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new solid phase microextraction (SPME) system, known as in-tube SPME, was recently developed using an open tubular fused-silica capilary column, instead of an SPME fiber, as the SPME device. On-line in-tube SPME is usually used in combination with high performance liquid chromatography. Drugs in biological samples are directly extracted and concentrated in the stationary phase of capillary columns by repeated draw/eject cycles of sample solution, and then directly transferred to the liquid chromatographic column. In-tube SPME is suitable for automation. Automated sample handling procedures not only shorten the total analysis time, but also usually provide better accuracy and precision relative to manual techniques. In-tube SPME has been demonstrated to be a very effective and highly sensitive technique to determine drugs in biological samples for various purposes such as therapeutic drug monitoring, clinical toxicology, bioavailability and pharmacokinetics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An overview of the current literature on the chemical processes involved in the ion formation from low molecular weight organic compounds by electrospray ionization mass spectrometry is given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes the preparation and characterization of the cellulose/ hydrated zirconium oxide composites prepared by conventional precipitation (PC) and homogeneous solution precipitation (PSH) methods. The composite obtained by the PC method was prepared by using an ammonia solution as the precipitating agent, while the composite obtained by the PSH method was prepared by using urea as the precipitating agent. The adsorption of dichromate ions on the composites was studied using factorial design 2³. The variables were: initial concentration, agitation time and mass of the composite. The data obtained agree better for the composite obtained by the PC method.