909 resultados para corrosion rate measurement


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A pronounced deficit of nitrogen (N) in the oxygen minimum zone (OMZ) of the Arabian Sea suggests the occurrence of heavy N-loss that is commonly attributed to pelagic processes. However, the OMZ water is in direct contact with sediments on three sides of the basin. Contribution from benthic N-loss to the total N-loss in the Arabian Sea remains largely unassessed. In October 2007, we sampled the water column and surface sediments along a transect cross-cutting the Arabian Sea OMZ at the Pakistan continental margin, covering a range of station depths from 360 to 1430 m. Benthic denitrification and anammox rates were determined by using 15N-stable isotope pairing experiments. Intact core incubations showed declining rates of total benthic N-loss with water depth from 0.55 to 0.18 mmol N m**-2 day**-1. While denitrification rates measured in slurry incubations decreased from 2.73 to 1.46 mmol N m**-2 day**-1 with water depth, anammox rates increased from 0.21 to 0.89 mmol N m**-2 day**-1. Hence, the contribution from anammox to total benthic N-loss increased from 7% at 360 m to 40% at 1430 m. This trend is further supported by the quantification of cd1-containing nitrite reductase (nirS), the biomarker functional gene encoding for cytochrome cd1-Nir of microorganisms involved in both N-loss processes. Anammox-like nirS genes within the sediments increased in proportion to total nirS gene copies with water depth. Moreover, phylogenetic analyses of NirS revealed different communities of both denitrifying and anammox bacteria between shallow and deep stations. Together, rate measurement and nirS analyses showed that anammox, determined for the first time in the Arabian Sea sediments, is an important benthic N-loss process at the continental margin off Pakistan, especially in the sediments at deeper water depths. Extrapolation from the measured benthic N-loss to all shelf sediments within the basin suggests that benthic N-loss may be responsible for about half of the overall N-loss in the Arabian Sea.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Entre os inibidores de corrosão clássicos que já são utilizados na indústria do petróleo, foram estudadas a imidazolina oleica e a quaternária através de técnicas eletroquímicas, gravimétrica e analíticas, para avaliar a eficiência de inibição e como esses inibidores atuam em meio ácido. O meio agressivo foi uma solução de NaCl 3,5% em massa acidificada com ácido clorídrico até atingir um pH=2 com o objetivo de simular o ambiente de extração petrolífera. O substrato empregado foi o aço carbono 1020. As técnicas eletroquímicas utilizadas foram: monitoramento do potencial de circuito aberto, medidas de resistência de polarização linear, espectroscopia de impedância eletroquímica (EIE ) e curvas de polarização. Os valores das componentes real e imaginária de impedância indicam uma resistência maior aos processos de transferência de carga com o aumento da concentração dos inibidores e os Diagramas de Bode de ângulo de fase, revelaram a presença de uma camada de inibidor adsorvida sobre o metal com uma constante de tempo em altas frequências observada para a imidazolina oleica e quaternária. Para a imidazolina quaternária, verificou-se que só para tempos maiores de imersão é que o filme se adsorve de forma eficiente demonstrando uma cinética mais lenta de adsorção. Nos ensaios gravimétricos, os resultados de taxa de corrosão em m/ano foram decrescentes com o tempo após período de imersão de 30 dias, para ambas as imidazolinas. O uso das técnicas analíticas foi necessário a fim de se compreender melhor o comportamento das imidazolinas sobre o aço no meio estudado. Os resultados da análise de íons férricos em solução, por emissão atômica, foram obtidos durante várias amostragens durante o período do ensaio de perda de massa, e foi possível verificar um processo de inibição da corrosão até doze dias de imersão do metal, depois disto ocorre um disparo na quantidade de ferro liberado em solução, sugerindo que pode estar ocorrendo uma degradação do inibidor após 12 dias de imersão. Para esclarecer esse ponto, análises por espectroscopia Raman dos produtos de fundo formados durante os ensaios de perda de massa indicaramm que a degradação pode realmente estar ocorrendo. Foi confirmado, também por espectroscopia Raman sobre a superfície do aço após imersão prévia em solução contendo a imidazolina oleica, que há uma película adsorvida que protege o metal do meio agressivo. Técnica de microscopia eletrônica de varredura foi utilizada para caracterizar os corpos de prova na ausência e presença do inibidor, depois dos ensaios eletroquímicos e foi possível caracterizar, através dessa técnica a maior eficiência inibidora do filme de imidazolina quaternária. Dois tipos de nanoconatiners foram avaliados para o encapsulamento das duas imidazolinas estudadas: nanocontainers a base do argilomineral haloiista e sílica mesoporosa tipo SBA 15. Resultados de impedância eletroquímica mostraram a liberação dos inibidores de corrosão encapsulados com o tempo de imersão. Análise na região do infravermelho por sonda de fibra ótica foi utilizada para comprovar química e qualitativamente a liberação do inibidor a partir dos nanorreservatórios, no meio agressivo.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A engenharia é a ciência que transforma os conhecimentos das disciplinas básicas aplicadas a fatos reais. Nosso mundo está rodeado por essas realizações da engenharia, e é necessário que as pessoas se sintam confortáveis e seguras nas mesmas. Assim, a segurança se torna um fator importante que deve ser considerado em qualquer projeto. Na engenharia naval, um apropriado nível de segurança e, em consequência, um correto desenho estrutural é baseado, atualmente, em estudos determinísticos com o objetivo de obter estruturas capazes de suportar o pior cenário possível de solicitações durante um período de tempo determinado. A maior parte das solicitações na estrutura de um navio se deve à ação da natureza (ventos, ondas, correnteza e tempestades), ou, ainda, aos erros cometidos por humanos (explosões internas, explosões externas e colisões). Devido à aleatoriedade destes eventos, a confiabilidade estrutural de um navio deveria ser considerada como um problema estocástico sob condições ambientais bem caracterizadas. A metodologia probabilística, baseada em estatística e incertezas, oferece uma melhor perspectiva dos fenômenos reais que acontecem na estrutura dos navios. Esta pesquisa tem como objetivo apresentar resultados de confiabilidade estrutural em projetos e planejamento da manutenção para a chapa do fundo dos cascos dos navios, as quais são submetidas a esforços variáveis pela ação das ondas do mar e da corrosão. Foram estudados modelos estatísticos para a avaliação da estrutura da viga-navio e para o detalhe estrutural da chapa do fundo. Na avaliação da estrutura da viga-navio, o modelo desenvolvido consiste em determinar as probabilidades de ocorrência das solicitações na estrutura, considerando a deterioração por corrosão, com base numa investigação estatística da variação dos esforços em função das ondas e a deterioração em função de uma taxa de corrosão padrão recomendada pela DET NORSKE VERITAS (DNV). A abordagem para avaliação da confiabilidade dependente do tempo é desenvolvida com base nas curvas de resistências e solicitações (R-S) determinadas pela utilização do método de Monte Carlo. Uma variação estatística de longo prazo das adversidades é determinada pelo estudo estatístico de ondas em longo prazo e ajustada por uma distribuição com base numa vida de projeto conhecida. Constam no trabalho resultados da variação da confiabilidade ao longo do tempo de um navio petroleiro. O caso de estudo foi simplificado para facilitar a obtenção de dados, com o objetivo de corroborar a metodologia desenvolvida.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the present paper, changes in mechanical properties of Portland cement-based mortars due to the addition of carbon nanotubes (CNT) and corrosion of embedded steel rebars in CNT cement pastes are reported. Bending strength, compression strength, porosity and density of mortars were determined and related to the CNT dosages. CNT cement paste specimens were exposed to carbonation and chloride attacks, and results on steel corrosion rate tests were related to CNT dosages. The increase in CNT content implies no significant variations of mechanical properties but higher steel corrosion intensities were observed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Metakaolin (MK), a calcined clay, was included as a partial cement replacement material, at up to 20% by weight of binder, in cement pastes and concrete, and its influence on the resistance to chloride ingress investigated. Reductions in effective chloride diffusion coefficients through hardened cement paste were obtained for binary blends and by combining OPC, MK and a second cement replacement material of pulverised fuel ash or ground granulated blast furnace slag. Steady state oxygen diffusion measurements through hardened cement pastes measured using an electrochemical cell showed that the interaction between charged species and the pore surfaces is a major factor in determining chloride diffusion rate. Rheology of the binder, particularly at high MK replacement levels, was found to have a dramatic influence on the diffusion performance of cement pastes. It was concluded that plasticising admixtures are essential for adequate dispersion of MK in cement pastes. Chloride concentration profile analysis of the concrete cylinders, exposed to sodium chloride solution for one year, was employed to obtain apparent chloride diffusion coefficients for concrete specimens. MK was found to reduce the depth of chloride penetration into concrete when compared with that of unblended mixes. Corrosion rate and corrosion potential measurements were taken on steel bars embedded in concrete exposed to a saline environment under conditions of cyclic wetting and drying. The initiation time for corrosion was found to be significantly longer for MK blended mixes than for plain OPC systems. The aggregate-paste interfacial zone of MK blended systems was investigated by steady state diffusion of chloride ions through mortar containing glass beads as model aggregate. For the model aggregate specimens tested the work confirmed the hypothesis that properties of the bulk paste are the controlling factors in ionic diffusion through mortar.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An experimental method for characterizing the time-resolved phase noise of a fast switching tunable laser is discussed. The method experimentally determines a complementary cumulative distribution function of the laser's differential phase as a function of time after a switching event. A time resolved bit error rate of differential quadrature phase shift keying formatted data, calculated using the phase noise measurements, was fitted to an experimental time-resolved bit error rate measurement using a field programmable gate array, finding a good agreement between the time-resolved bit error rates.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Advances in biomaterials have enabled medical practitioners to replace diseased body parts or to assist in the healing process. In situations where a permanent biomaterial implant is used for a temporary application, additional surgeries are required to remove these implants once the healing process is complete, which increases medical costs and patient morbidity. Bio-absorbable materials dissolve and are metabolized by the body after the healing process is complete thereby negating additional surgeries for removal of implants. Magnesium alloys as novel bio-absorbable biomaterials, have attracted great attention recently because of their good mechanical properties, biocompatibility and corrosion rate in physiological environments. However, usage of Mg as biodegradable implant has been limited by its poor corrosion resistance in the physiological solutions. An optimal biodegradable implant must initially have slow degradation to ensure total mechanical integrity then degrade over time as the tissue heals. The current research focuses on surface modification of Mg alloy (MZC) by surface treatment and polymer coating in an effort to enhance the corrosion rate and biocompatibility. It is envisaged that the results obtained from this investigation would provide the academic community with insights for the utilization of bio-absorbable implants particularly for patients suffering from atherosclerosis. The alloying elements used in this study are zinc and calcium both of which are essential minerals in the human metabolic and healing processes. A hydrophobic biodegradable co-polymer, polyglycolic-co-caprolactone (PGCL), was used to coat the surface treated MZC to retard the initial degradation rate. Two surface treatments were selected: (a) acid etching and (b) anodization to produce different surface morphologies, roughness, surface energy, chemistry and hydrophobicity that are pivotal for PGCL adhesion onto the MZC. Additionally, analyses of biodegradation, biocompatibility, and mechanical integrity were performed in order to investigate the optimum surface modification process, suitable for biomaterial implants. The study concluded that anodization created better adhesion between the MZC and PGCL coating. Furthermore, PGCL coated anodized MZC exhibited lower corrosion rate, good mechanical integrity, and better biocompatibility as compared with acid etched.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The main problem on the exploration activity on petroleum industry is the formation water resulted on the fields producing. The aggravating of this problem is correlated with the advancing technologies used on the petroleum extractions and on its secondary approach objecting the reobtainment of this oil. Among the main contaminants of the water formation are corrosives gases such as: O2, CO2 and H2S, some solids in suspension and dissolved salts. Concerning to those gases the CO2 is the one that produce significant damage for carbon steel on corrosion process of the petroleum and gas industries. Corrosion inhibitors for carbon steel in formation water is one of the most used agents in control of those damages. In this context, the poor investigations of carbon steel corrosion proceeding from solids in suspension is an opened field for studies. On this work the inhibitor effect of the commercial CORRTREAT 703 was evaluated on some specific solids in suspension at saline medium containing 10.000 ppm of de-aerated chloride using CO2 until non oxygen atmosphere been present. For that, quartz, calcium carbonate, magnetite and iron sulphide were subjected to this investigation as the selected solids. The effect of this inhibitor on corrosion process correlated with those specific solids, was measured using electrochemical (resistance of linear polarization and galvanic pair) and gravimetrical techniques. During all the experimental work important parameters were monitored such as: pH, dissolved oxygen, temperature, instantaneous corrosion rate and galvanic current. According to the obtained results it was proved that the suspension solids calcium carbonate and iron sulphide decrease the corrosion process in higher pH medium. Meanwhile the quartz and magnetite been hardness increase corrosion by broking of the passive layer for erosion. In the other hand, the tested inhibitor in concentration of 50 ppm, showed to be effective (91%) in this corrosion process

Relevância:

80.00% 80.00%

Publicador:

Resumo:

With the increasing of demand for natural gas and the consequent growth of the pipeline networks, besides the importance of transport and transfer of oil products by pipeline, and when it comes to product quality and integrity of the pipeline there is an important role regarding to the monitoring internal corrosion of the pipe. This study aims to assess corrosion in three pipeline that operate with different products, using gravimetric techniques and electrical resistance. Chemical analysis of residues originated in the pipeline helps to identify the mechanism corrosive process. The internal monitoring of the corrosion in the pipelines was carried out between 2009 and 2010 using coupon weight loss and electrical resistance probe. Physico-chemical techniques of diffraction and fluorescence X-rays were used to characterize the products of corrosion of the pipelines. The corrosion rate by weight loss was analyzed for every pipeline, only those ones that has revealed corrosive attack were analyzed located corrosion rate. The corrosion potential was classified as low to pipeline gas and ranged from low to severe for oil pipelines and the pipeline derivatives. Corrosion products were identified as iron carbonate, iron oxide and iron sulfide

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Two backward-facing models with step heights of 2 and 3 mm are used to measure the convective surface heat transfer rates by using platinum thin-film gauges, deposited on Macor inserts. Heat transfer rates have been theoretically calculated along the flat plate portion of a model using the Eckert reference temperature method. The experimentally determined surface heat transfer rate distributions are compared with theoretical and numerical estimations. Experimental heat flux distribution over a flat plate model showed good agreement with the reference temperature method at stagnation enthalpy range of 0.8-2 MJ/kg. Theoretical analysis has been used for downstream of a backward-facing step using Gai's nondimensional analysis. It has been found from the present study that approximately 10 and 8 step heights are required for the flow to reattach for 2 and 3 mm step height backward-facing step models, respectively, at a nominal Mach number of 7.6.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Turbidity measurement for the absolute coagulation rate constant of suspensions has been extensively adopted because of its simplicity and easy implementation. A key factor to derive the rate constant from experimental data is how to theoretically evaluate the so-called optical factor involved in calculating the extinction cross section of doublets formed in the aggregation. In a previous paper, we have shown that compared with other theoretical approaches, the T-matrix method provides a robust solution to this problem and is effective in extending the applicability range of the turbidity methodology as well as increasing measurement accuracy. This paper will provide a more comprehensive discussion about the physical insight of using the T-matrix method in turbidity measurement and associated technical details. In particular, the importance of ensuring the correct value for the refractive indices for colloidal particles and the surrounding medium used in the calculation is addressed because the indices generally vary with the wavelength of the incident light. The comparison of calculated results with experiments shows that the T-matrix method can correctly calculate optical factors even for large particles, whereas other existing theories cannot. In addition, the calculated data of the optical factor by the T-matrix method for a range of particle radii and incident light wavelengths are listed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The existing theories dealing with the evaluation of the absolute coagulation rate constant by turbidity measurement were experimentally tested for different particle-sized (radius = a) suspensions at incident wavelengths (lambda) ranging from near-infrared to ultraviolet light. When the size parameter alpha = 2 pi a/lambda > 3, the rate constant data from previous theories for fixed-sized particles show significant inconsistencies at different light wavelengths. We attribute this problem to the imperfection of these theories in describing the light scattering from doublets through their evaluation of the extinction cross section. The evaluations of the rate constants by all previous theories become untenable as the size parameter increases and therefore hampers the applicable range of the turbidity measurement. By using the T-matrix method, we present a robust solution for evaluating the extinction cross section of doublets formed in the aggregation. Our experiments show that this new approach is effective in extending the applicability range of the turbidity methodology and increasing measurement accuracy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Our previous studies have shown that the determination of coagulation rate constants by turbidity measurement becomes impossible for a certain operating wavelength (that is, its blind point) because at this wavelength the change in the turbidity of a dispersion completely loses its response to the coagulation process. Therefore, performing the turbidity measurement in the wavelength range near the blind point should be avoided. In this article, we demonstrate that the turbidity measurement of the rate constant for coagulation of a binary dispersion containing particles of two different sizes (heterocoagulation) presents special difficulties because the blind point shifts with not only particle size but also with the component fraction. Some important aspects of the turbidity measurement for the heterocoagulation rate constant are discussed and experimentally tested. It is emphasized that the T-matrix method can be used to correctly evaluate extinction cross sections of doublets formed during the heterocoagulation process, which is the key data determining the rate constant from the turbidity measurement, and choosing the appropriate operating wavelength and component fraction are important to achieving a more accurate rate constant. Finally, a simple scheme in experimentally determining the sensitivity of the turbidity changes with coagulation over a wavelength range is proposed.