942 resultados para contrast thresholds
Resumo:
OBJECTIVE: To test the ability of a novel phase-shifting medium (PSM) to provide sustained distension of the uterine cavity and produce saline infusion sonography (SIS)-like images in a simplified contrast ultrasound procedure. DESIGN: Prospective pilot feasibility trial of a new diagnostic procedure, contrast ultrasound. SETTING: Clinical reproductive endocrine and infertility unit of regional teaching hospital. PATIENT(S): Twenty-six asymptomatic infertile women (group I) and 27 women presenting with dysfunctional uterine bleeding (DUB) who were scheduled for exploratory surgery (group II). INTERVENTION(S): All women who were temporarily on oral contraceptive first had a regular pelvic ultrasound followed by the intrauterine instillation of up to 3 mL PSM, using a regular insemination catheter, after which all instruments were removed and a regular ultrasound was performed again. RESULT(S): In all 53 women, intrauterine instillation of 1-3 mL PSM resulted in a 3-7 mm uterine distension, sufficient to produce SIS-like images of the uterine cavity that lasted 7-10 min. Contrast ultrasound revealed an endometrial polyp in 3 asymptomatic women of group I. In group II. 12 of 14 women (86%) whose vaginal ultrasound were positive or dubious had positive findings with contrast ultrasound; 9 of 12 patients whose vaginal ultrasounds were negative also had positive contrast ultrasound findings. All the positive and negative findings of contrast ultrasound made in group II were confirmed anatomically (sensitivity and specificity of 100%), whereas the correlation for standard vaginal ultrasound was markedly lower at 57.1% and 85.7%, respectively. Most patients (46 of 53) reported no discomfort during or after the procedure, and 7 women described the procedure as mildly uncomfortable. CONCLUSION(S): Contrast ultrasound, a novel simple diagnostic procedure conducted after intrauterine instillation of 1-3 mL PSM using a simple plastic catheter, delivered SIS-quality images in asymptomatic (group I) and symptomatic (group II) patients while retaining the simplicity of standard ultrasound. We therefore foresee broad application of contrast ultrasound for sensitive and specific assessment for uterine pathologies in the physician's office.
Resumo:
OBJECTIVE: : Identification of children with elevated blood pressure (BP) is difficult because of the multiple sex, age, and height-specific thresholds to define elevated BP. We propose a simple set of absolute height-specific BP thresholds and evaluate their performance to identify children with elevated BP in two different populations. METHODS: : Using the 95th sex, age, and relative-height BP US thresholds to define elevated BP in children (standard criteria), we derived a set of (non sex- and non age-specific) absolute height-specific BP thresholds for 11 height categories by 10 cm increments. Using data from large school-based surveys conducted in Switzerland (N = 5207; 2621 boys, 2586 girls; age range: 10.1-14.9 years) and in the Seychelles (N = 25 759; 13 048 boys, 12 711 girls; age range: 4.4-18.8 years), we evaluated the performance of these height-specific thresholds to identify children with elevated BP. We also derived sex-specific absolute height-specific BP thresholds and compared their performance. RESULTS: : In the Swiss and the Seychelles surveys, the prevalence of elevated BP (standard criteria) was 11.4 and 9.1%, respectively. The height-specific thresholds to identify elevated BP had a sensitivity of 80 and 84%, a specificity of 99 and 99%, a positive predictive value of 92 and 91%, and a negative predictive value of 97 and 98%, respectively. Performance of sex-specific absolute height-specific BP thresholds was similar. CONCLUSION: : A simple table of height-specific BP thresholds allowed identifying children with elevated BP with high sensitivity and excellent specificity.
Resumo:
PROPÒSIT: Estudiar l'efecte de la cirurgia LASIK en la llum dispersa i la sensibilitat al contrast. MÈTODES: Vint-i-vuit pacients van ser tractats amb LASIK. La qualitat visual es va avaluar abans de l'operació i dos mesos després. RESULTATS: La mitjana de llum dispersa i la sensibilitat al contrast abans de l'operació no va canviar en dos mesos després. Només un ull tenia un marcat augment en la llum dispersa. Nou ulls van presentar una lleugera disminució en la sensibilitat al contrast. S'han trobat dues complicacions. CONCLUSIÓ: Després de LASIK la majoria dels pacients (80%) no van tenir complicacions i van mantenir la seva qualitat visual. Uns pocs pacients (16%) van tenir una mica de qualitat visual disminuïda. Molt pocs (4%) van tenir complicacions clíniques amb disminució en la qualitat visual.
Resumo:
BACKGROUND AND PURPOSE: A right-to-left shunt can be identified by contrast transcranial Doppler ultrasonography (c-TCD) at rest and/or after a Valsalva maneuver (VM) or by arterial blood gas (ABG) measurement. We assessed the influence of controlled strain pressures and durations during VM on the right-to-left passage of microbubbles, on which depends the shunt classification by c-TCD, and correlated it with the right-to-left shunt evaluation by ABG measurements in stroke patients with patent foramen ovale (PFO). METHODS: We evaluated 40 stroke patients with transesophageal echocardiography-documented PFO. The microbubbles were recorded with TCD at rest and after 4 different VM conditions with controlled duration and target strain pressures (duration in seconds and pressure in cm H2O, respectively): V5-20, V10-20, V5-40, and V10-40. The ABG analysis was performed after pure oxygen breathing in 34 patients, and the shunt was calculated as percentage of cardiac output. RESULTS: Among all VM conditions, V5-40 and V10-40 yielded the greatest median number of microbubbles (84 and 95, respectively; P<0.01). A significantly larger number of microbubbles were detected in V5-40 than in V5-20 (P<0.001) and in V10-40 than in V10-20 (P<0.01). ABG was not sensitive enough to detect a shunt in 31 patients. CONCLUSIONS: The increase of VM expiratory pressure magnifies the number of microbubbles irrespective of the strain duration. Because the right-to-left shunt classification in PFO is based on the number of microbubbles, a controlled VM pressure is advised for a reproducible shunt assessment. The ABG measurement is not sensitive enough for shunt assessment in stroke patients with PFO.
Value of PET/CT versus contrast-enhanced CT in identifying chest wall invasion (T3) by NSCLC [B-671]
Resumo:
Purpose: To determine the diagnostic value of 18F-FDG PET/CT versus contrastenhanced CT in identifying chest wall invasion by NSCLC. Methods and Materials: The primary selection criterion was a peripheral tumor of any size with contact to the chest wall. A total of 25 patients with pathologically proven NSCLC satisfied these criteria. Chest wall invasion was interpreted upon PET/CT when a frank costal or intercostal 18F-FDG uptake was identified with or without concomitant morphologic alterations. On the other hand, the existence of periosteal rib reaction/erosion, chest wall thickening or obliteration of the pleural fat layer either separately or combined were considered essential diagnostic criteria for disease extension into the chest wall upon contrast-enhanced CT. The results were correlated with the final histological analysis. Results: Among the studied cohort, 13/25 (52%) patients had chest wall invasion consistent with T3 disease. Both PET/CT and contrast-enhanced CT successfully identified 12/13 (92%) of these patients. The single false-negative result was due to parietal pleural invasion. On the other hand, one false-positive result was encountered by PET/CT in a dyspneic patient; whereas, CT analysis revealed false-positive results in six patients. In these patients, periosteal rib reaction (n = 2) or asymmetric enlargement of adjacent chest wall muscles (n = 1) were identified along with an obliterated pleural fat layer (n = 6). The sensitivity, specificity, and accuracy of PET/CT and contrast-enhanced CT were 92, 91 and 92% versus 92, 50 and 72%. Conclusion: 18F-FDG PET/CT is an accurate diagnostic modality in identifying.
Resumo:
Purpose: To describe low mechanical index grey scale contrast enhanced breast ultrasound in patients with intraductal echogenic material in the differentiation of papillomas from intraductal secretions. Methods and materials: In five patients with echographically detected ductal dilatation containing echogenic material low mechanical index grey scale contrast enhanced ultrasonography was performed. No patient had nipple discharge. The examination was performed with a 9 MHz linear transducer after injection of 4 ml of Sonovue. It was assessed if contrast enhancement was present or not. The results were correlated with histologic results after surgical resection or percutaneous biopsy when performed. Results: In 3 patients contrast enhancement was observed. These patients were operated and the papillomas confirmed by histology. In two patients no contrast enhancement was observed. In one of these two patients percutaneous biopsy was performed without evidence of a papillary lesion. The second patient presented with multiple dilated ducts containing echogenic material. No biopsy was performed but breast MRI showed no intraductal enhancement supporting the non papillary nature of the intraductal material. Conclusion: This pilot study shows that contrast enhanced ultrasound is able to detect the vascularisation of papillomas and that it may differentiate intraductal papillomas from secretions.
Resumo:
BACKGROUND: Fatalities following contrast medium exposure are extremely rare in clinical routine, though they may occur as an exception. Some may fall under the purview of the inquiring authorities and forensic pathologists due to their in-hospital occurrence. The purpose of this study was to assess the risk factors for anaphylaxis due to contrast medium administration that can be identified in fatal cases. METHODS: Fatalities occurred during the course of clinical investigations with contrast media described in the literature and fatal reactions to contrast agents that had undergone forensic investigations in our medicolegal center were reviewed with respect to patient characteristics, administered contrast medium, performed biochemical investigations and potential risk factors identified based on clinical history and medical records. RESULTS: Biochemical investigations into the fatal cases examined in our facility revealed increased mast cell tryptase, total IgE and activated mast cells in all subjects. Data obtained from the literature and our own investigations indicated that in only a minority of the fatal cases had there been previous exposure to contrast compounds, while most cases of severe anaphylaxis involved patients who apparently reacted on initial exposure. CONCLUSIONS: Most fatal cases failed to present any identifiable predisposing conditions out of those traditionally considered as risk factors for an anaphylactic reaction to contrast compounds in the medical histories of the patients. Comprehensive clinical histories and thorough reviews of medical data, along with exhaustive forensic investigations, provide information that is relevant in order to better appreciate the interwoven relationships linking all factors potentially involved in the pathogenesis of fatal anaphylaxis to contrast media. © 2014 S. Karger AG, Basel.
Resumo:
Modern urban lifestyle encourages the prolongation of wakefulness, leaving less and less time for sleep. Although the exact functions of sleep remain one of the biggest mysteries in neuroscience, the society is well aware of the negative consequences of sleep loss on human physical and mental health and performance. Enhancing sleep's recuperative functions might allow shortening sleep duration while preserving the beneficial effects of sleep. During sleep, brain activity oscillates across a continuum of frequencies. Individual oscillations have been suggested to underlie distinct functions for sleep and cognition. Gaining control about individual oscillations might allow boosting their specific functions. Sleep spindles are 11 - 15 Hz oscillations characteristic for light non-rapid-eye-movement sleep (NREMS) and have been proposed to play a role in memory consolidation and sleep protection against environmental stimuli. The reticular thalamic nucleus (nRt) has been identified as the major pacemaker of spindles. Intrinsic oscillatory burst discharge in nRt neurons, arising from the interplay of low-threshold (T-type) Ca2+ channels (T channels) and small conductance type 2 (SK2) K+ channels (SK2 channels), underlies this pacemaking function. In the present work we investigated the impact of altered nRt bursting on spindle generation during sleep by studying mutant mice for SK2 channels and for CaV3.3 channels, a subtype of T channels. Using in vitro electrophysiology I showed that nRt bursting was abolished in CaV3.3 knock out (CaV3.3 KO) mice. In contrast, in SK2 channel over-expressing (SK2-OE) nRt cells, intrinsic repetitive bursting was prolonged. Compared to wildtype (WT) littermates, altered nRt burst discharge lead to weakened thalamic network oscillations in vitro in CaV3.3 KO mice, while oscillatory activity was prolonged in SK2-OE mice. Sleep electroencephalographic recordings in CaV3.3 KO and SK2-OE mice revealed that reduced or potentiated nRt bursting respectively weakened or prolonged sleep spindle activity at the NREMS - REMS transition. Furthermore, SK2-OE mice showed more consolidated NREMS and increased arousal thresholds, two correlates of good sleep quality. This thesis work suggests that CaV3.3 and SK2 channels may be targeted in order to modulate sleep spindle activity. Furthermore, it proposes a novel function for spindles in NREMS consolidation. Finally, it provides evidence that sleep quality may be improved by promoting spindle activity, thereby supporting the hypothesis that sleep quality can be enhanced by modulating oscillatory activity in the brain. Le style de vie moderne favorise la prolongation de l'éveil, laissant de moins en moins de temps pour le sommeil. Même si le rôle exact du sommeil reste un des plus grands mystères des neurosciences, la société est bien consciente des conséquences négatives que provoque un manque de sommeil, à la fois sur le plan de la santé physique et mentale ainsi qu'au niveau des performances cognitives. Augmenter les fonctions récupératrices du sommeil pourrait permettre de raccourcir la durée du sommeil tout en en conservant les effets bénéfiques. Durant le sommeil, on observe des oscillations à travers un continuum de fréquences. Il a été proposé que chaque oscillation pourrait être à l'origine de fonctions spécifiques pour le sommeil et la cognition. Pouvoir de contrôler les oscillations individuelles permettrait d'augmenter leurs fonctions respectives. Les fuseaux sont des oscillations de 11 à 15 Hz caractéristiques du sommeil à ondes lentes léger et il a été suggéré qu'elles jouent un rôle majeur pour la consolidation de la mémoire ainsi que dans la protection du sommeil contre les stimuli environnementaux. Le nucleus réticulaire du thalamus (nRt) a été identifié en tant que générateur de rythme des fuseaux. Les bouffées oscillatoires intrinsèques des neurones du nRt, provenant de l'interaction de canaux calciques à bas seuil de type T (canaux T) et de canaux potassiques à faible conductance de type 2 (canaux SK2), sont à l'origine de la fonction de générateur de rythme. Dans ce travail, j'ai étudié l'impact de la modulation de bouffées de nRT sur la génération des fuseaux pendant le sommeil en investiguant des souris génétiquement modifiées pour les canaux SK2 et les canaux CaV3.3, un sous-type de canaux T. En utilisant l'électrophysiologie in vitro j'ai démontré que les bouffées du nRT étaient abolies dans les souris knock-out du type CaV3.3 (CaV3.3 KO). D'autre part, dans les cellules nRT sur-exprimant les canaux SK2 (SK2-OE), les bouffées oscillatoires intrinsèques étaient prolongées. Par rapport aux souris wild type, les souris CaV3.3 KO ont montré un affaiblissement des oscillations thalamiques en réponse à un changement des bouffées de nRT, alors que l'activité oscillatoire était prolongée dans les souris SK2-OE. Des enregistrements EEG du sommeil dans des souris de type CaV3.3 KO et SK2-OE ont révélé qu'une réduction ou augmentation des bouffées nRT ont respectivement affaibli ou prolongé l'activité des fuseaux durant les transitions du sommeil à ondes lentes au sommeil paradoxal. De plus, les souris SK2-OE ont montré des signes de consolidation du sommeil à ondes lentes et un seuil augmenté pour le réveil, deux mesures qui corrèlent avec une bonne qualité du sommeil. Le travail de cette thèse propose que les canaux CaV3.3 et SK2 pourrait être ciblés pour moduler l'activité des fuseaux. De plus, je propose une fonction nouvelle pour les fuseaux dans la consolidation du sommeil à ondes lentes. Finalement je suggère que la qualité du sommeil peut être améliorée en promouvant l'activité des fuseaux, soutenant ainsi l'idée que la qualité du sommeil peut être améliorée en modulant l'activité oscillatoire dans le cerveau.
Resumo:
Tone Mapping is the problem of compressing the range of a High-Dynamic Range image so that it can be displayed in a Low-Dynamic Range screen, without losing or introducing novel details: The final image should produce in the observer a sensation as close as possible to the perception produced by the real-world scene. We propose a tone mapping operator with two stages. The first stage is a global method that implements visual adaptation, based on experiments on human perception, in particular we point out the importance of cone saturation. The second stage performs local contrast enhancement, based on a variational model inspired by color vision phenomenology. We evaluate this method with a metric validated by psychophysical experiments and, in terms of this metric, our method compares very well with the state of the art.