986 resultados para composite function


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Previous work suggesting a better correlation of diastolic than systolic function with exercise capacity in heart failure may reflect the -relative insensitivity and load-dependence of ejection fraction (EF). We sought the correlation of new and more sensitive methods of quantifying systolic and diastolic function and filling pressure with functional capacity. Methods We studied 155 consecutive exercise tests on 95 patients with congestive heart failure (81 male, aged 62 +/- 10 years), who underwent resting 2-climensional echocardiography and tissue Doppler imaging before and after measurement of maximum oxygen uptake (peak VO2)Results The resting EF was 3 1 % 10% and a peak VO(2)was 13 +/- 5 mL/kg/min; the majority of these patients (80%) had an ischemic cardiornyopathy. Resting EF (r 0.14, P =.09) correlated poorly with peak VO2 and mean systolic (r = 0.23, P =.004) and diastolic tissue velocities (r 0.18, P =.02). Peak EF was weakly correlated with the mean systolic (r = 0.18, P =.02) and diastolic velocities (r = 0.16, P <.04). The mean sum of systolic and diastolic velocities in both annuli (r = 0.30, P <.001) and E/Ea ratio (r 0.31, P <.001) were better correlated with peak VO2 Prediction of peak VO2 was similar with models based on models of filling pressure (R = 0.61), systolic factors (R = 0.63), and diastolic factors (R 0.59), although a composite model of filling pressure, systolic and diastolic function was a superior predictor of peak VO2 (R 0.69; all P<.001). Conclusions The reported association of diastolic rather than systolic function with functional capacity may have reflected the limitations of EF. Functional capacity appears related not only to diastolic function, but also to systolic function and filling pressure, and is most closely associated with a combination of these factors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: We evaluated the relationship of renal function and ischaemic and bleeding risk as well as the efficacy and safety of the P2Y12 platelet receptor inhibitor ticagrelor in stable patients with prior myocardial infarction (MI). Methods & Results: Patients with a history of MI 1-3 years prior from the Prevention of Cardiovascular Events in Patients with Prior Heart Attack Using Ticagrelor Compared to Placebo on a Background of Aspirin (PEGASUS)-TIMI 54 were stratified based on estimated glomerular filtration rate (eGFR), with<60 ml/min/1.73m2 prespecified for analysis of the effect of ticagrelor on the primary efficacy composite of cardiovascular death, MI, or stroke (MACE) and the primary safety endpoint of TIMI major bleeding. Of 20,898 patients, those with eGFR<60 (N=4,849, 23.2%) had a greater risk of MACE at 3 years relative to those without, which remained significant after multivariable adjustment (HRadj 1.54, 95% CI 1.27–1.85, p<0.001). The relative risk reduction in MACE with ticagrelor was similar in those with eGFR<60 (ticagrelor pooled vs. placebo: HR 0.81; 95% CI 0.68–0.96) vs. ≥60 (HR 0.88; 95% CI 0.77–1.00, pinteraction=0.44). However, due to the greater absolute risk in the former group, the absolute risk reduction with ticagrelor was higher: 2.7% vs. 0.63%. Bleeding tended to occur more frequently in patients with renal dysfunction. The absolute increase in TIMI major bleeding with ticagrelor was similar in those with and without eGFR<60 (1.19% vs. 1.43%), whereas the excess of minor bleeding tended to be more pronounced (1.93% vs. 0.69%). Conclusion: In patients with a history of MI, patients with renal dysfunction are at increased risk of MACE and consequently experience a particularly robust absolute risk reduction with long-term treatment with ticagrelor.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The deposition and properties of electroless nickel composite coatings containing graphite, PTFE and chromium were investigated. Solutions were developed for the codeposition of graphite and chromium with electroless nickel. Solutions for the deposition of graphite contained heavy metal ions for stability, with non-ionic and anionic surfactants to provide wetting and dispersion of the particles. Stability for the codeposition of chromium particles was achieved by oxidation of the chromium. Thin oxide layers of 200 nm thick prevented initiation of the electroless reaction onto the chromium. A mechanism for the formation of electroless composite coatings was considered based on the physical adsorption of particles and as a function of the adsorption of charged surfactants and metal cations from solution. The influence of variables such as particle concentration in solution, particle size, temperature, pH, and agitation on the volume percentage of particles codeposited was studied. The volume percentage of graphite codeposited was found to increase with concentration in solution and playing rate. An increase in particle size and agitation reduced the volume percentage codeposited. The hardness of nickel-graphite deposits was found to decrease with graphite content in the as-deposited and heat treated condition. The frictional and wear properties of electroless nickel-graphite were studied and compared to those of electroless nickel-PTFE. The self-lubricating nature of both coatings was found to be dependent on the ratio of coated area to uncoated area, the size and content of lubricating material in the deposit, and the load between contacting surfaces. The mechanism of self-lubrication was considered, concluding that graphite only produced an initial lubricating surface due to the orientation of flakes, unlike PTFE, which produced true self-lubrication throughout the coating life. Heat treatment of electroless nickel chromium deposits at 850oC for 8 and 16 hours produced nickel-iron-chromium alloy deposits with a phosphorus rich surface of high hardness. Coefficients of friction and wear rates were intially moderate for the phosphorus rich layer but increased for the nickel-iron-chromium region of the coating.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effects of a thermal residual stress field on fatigue crack growth in a silicon carbide particle-reinforced aluminum alloy have been measured. Stress fields were introduced into plates of material by means of a quench from a solution heat-treatment temperature. Measurements using neutron diffraction have shown that this introduces an approximately parabolic stress field into the plates, varying from compressive at the surfaces to tensile in the center. Long fatigue cracks were grown in specimens cut from as-quenched plates and in specimens which were given a stress-relieving overaging heat treatment prior to testing. Crack closure levels for these cracks were determined as a function of the position of the crack tip in the residual stress field, and these are shown to differ between as-quenched and stress-relieved samples. By monitoring the compliance of the specimens during fatigue cycling, the degree to which the residual stresses close the crack has been evaluated. © 1995 The Minerals, Metals & Material Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ageing response of 2124 Al-SiC particulate metal-matrix composite (MMC) and unreinforced alloy has been examined using hardness measurements and Arrhenius analysis. The formation of phases during precipitation has been studied using differential scanning calorimetry (DSC). The MMC exhibits accelerated ageing compared to unreinforced alloy, due to enhanced S′ formation. The activation energy for diffusion is lower in the MMC than in the unreinforced alloy. DSC scans show Guinier-Preston B (GPB) zone nucleation to occur at a lower temperature in the MMC, whilst the total volume of GPB zones formed is smaller than in the unreinforced alloy. A model has been proposed to explain the GPB zone formation behaviour, in which ease of GPB zone nucleation varies within the MMC, as a function of ageing time and of position within the matrix. S′ formation is enhanced in the MMC because of improved diffusion and a large increase in density of heterogeneous nucleation sites compared to the unreinforced alloy. © 1994 Chapman & Hall.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fracture behaviour and plane strain fracture toughness, KIC, of four 8090-based metal-matrix composites containing 20 weight % SiC particles, 3, 6 and 23 μm in diameter, has been evaluated as a function of matrix ageing condition. Toughness values are found to be almost independent of reinforcement size. Ageing at 170°C results in a monotonic decrease in toughness with increasing strength up to the peak condition, with no subsequent recovery in toughness on overageing. However, unlike reinforced 8090, the composites are not found to be susceptible to intergranular embrittlement on overageing. The observed trends are found to be independent of reinforcement size. These findings are explained in terms of the strength, work hardening behaviour and nature and distribution of void-nucleating particles in the matrix. © 1993.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fleck and Johnson (Int. J. Mech. Sci. 29 (1987) 507) and Fleck et al. (Proc. Inst. Mech. Eng. 206 (1992) 119) have developed foil rolling models which allow for large deformations in the roll profile, including the possibility that the rolls flatten completely. However, these models require computationally expensive iterative solution techniques. A new approach to the approximate solution of the Fleck et al. (1992) Influence Function Model has been developed using both analytic and approximation techniques. The numerical difficulties arising from solving an integral equation in the flattened region have been reduced by applying an Inverse Hilbert Transform to get an analytic expression for the pressure. The method described in this paper is applicable to cases where there is or there is not a flat region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method for estimating the time to colonization of Methicillin-resistant Staphylococcus Aureus (MRSA) patients is developed in this paper. The time to colonization of MRSA is modelled using a Bayesian smoothing approach for the hazard function. There are two prior models discussed in this paper: the first difference prior and the second difference prior. The second difference prior model gives smoother estimates of the hazard functions and, when applied to data from an intensive care unit (ICU), clearly shows increasing hazard up to day 13, then a decreasing hazard. The results clearly demonstrate that the hazard is not constant and provide a useful quantification of the effect of length of stay on the risk of MRSA colonization which provides useful insight.