971 resultados para broncho-alveolar lavage fluids


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alveolar macrophages form the first line of defense against inhaled droplets containing Mycobacterium tuberculosis by controlling mycobacterial growth and regulating T cell responses. CD4+ and gamma delta T cells, two major T cell subsets activated by M. tuberculosis, require accessory cells for activation. However, the ability of alveolar macrophages to function as accessory cells for T cell activation remains controversial. We sought to determine the ability of alveolar macrophages to serve as accessory cells for resting (HLA-DR-, IL-2R-) and activated (HLA-DR+, IL-2R+) gamma delta T cells in response to M. tuberculosis and its Ag, and to compare accessory cell function for gamma delta T cells of alveolar macrophages and blood monocytes obtained from the same donor. Alveolar macrophages were found to serve as accessory cells for both resting and activated gamma delta T cells in response to M. tuberculosis Ag. At high alveolar macrophage to T cell ratios (> 3:1), however, expansion of resting gamma delta T cells was inhibited by alveolar macrophages. The inhibition of resting gamma delta T cells by alveolar macrophages was dose-dependent, required their presence during the first 24 h, and was partially overcome by IL-2. Alveolar macrophages did not inhibit activated gamma delta T cells even at high accessory cell to T cell ratios, and alveolar macrophages functioned as well as monocytes as accessory cells. Monocytes were not inhibitory for either resting or activated gamma delta T cells. These findings support the following model. In the normal alveolus the alveolar macrophage to T cell ratio is > or = 9:1, and therefore the threshold for resting gamma delta T cell activation is likely to be high. Once a nonspecific inflammatory response occurs, such as after invasion by M. tuberculosis, this ratio is altered, favoring gamma delta T cell activation by alveolar macrophages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infection is a major cause of mortality and morbidity after thoracic organ transplantation. The aim of the present study was to evaluate the infectious complications after lung and heart transplantation, with a special emphasis on the usefulness of bronchoscopy and the demonstration of cytomegalovirus (CMV), human herpes virus (HHV)-6, and HHV-7. We reviewed all the consecutive bronchoscopies performed on heart transplant recipients (HTRs) from May 1988 to December 2001 (n = 44) and lung transplant recipients (LTRs) from February 1994 to November 2002 (n = 472). To compare different assays in the detection of CMV, a total of 21 thoracic organ transplant recipients were prospectively monitored by CMV pp65-antigenemia, DNAemia (PCR), and mRNAemia (NASBA) tests. The antigenemia test was the reference assay for therapeutic intervention. In addition to CMV antigenemia, 22 LTRs were monitored for HHV-6 and HHV-7 antigenemia. The diagnostic yield of the clinically indicated bronchoscopies was 41 % in the HTRs and 61 % in the LTRs. The utility of the bronchoscopy was highest from one to six months after transplantation. In contrast, the findings from the surveillance bronchoscopies performed on LTRs led to a change in the previous treatment in only 6 % of the cases. Pneumocystis carinii and CMV were the most commonly detected pathogens. Furthermore, 15 (65 %) of the P. carinii infections in the LTRs were detected during chemoprophylaxis. None of the complications of the bronchoscopies were fatal. Antigenemia, DNAemia, and mRNAemia were present in 98 %, 72 %, and 43 % of the CMV infections, respectively. The optimal DNAemia cut-off levels (sensitivity/specificity) were 400 (75.9/92.7 %), 850 (91.3/91.3 %), and 1250 (100/91.5 %) copies/ml for the antigenemia of 2, 5, and 10 pp65-positive leukocytes/50 000 leukocytes, respectively. The sensitivities of the NASBA were 25.9, 43.5, and 56.3 % in detecting the same cut-off levels. CMV DNAemia was detected in 93 % and mRNAemia in 61 % of the CMV antigenemias requiring antiviral therapy. HHV-6, HHV-7, and CMV antigenemia was detected in 20 (91 %), 11 (50 %), and 12 (55 %) of the 22 LTRs (median 16, 31, and 165 days), respectively. HHV-6 appeared in 15 (79 %), HHV-7 in seven (37 %), and CMV in one (7 %) of these patients during ganciclovir or valganciclovir prophylaxis. One case of pneumonitis and another of encephalitis were associated with HHV-6. In conclusion, bronchoscopy is a safe and useful diagnostic tool in LTRs and HTRs with a suspected respiratory infection, but the role of surveillance bronchoscopy in LTRs remains controversial. The PCR assay acts comparably with the antigenemia test in guiding the pre-emptive therapy against CMV when threshold levels of over 5 pp65-antigen positive leukocytes are used. In contrast, the low sensitivity of NASBA limits its usefulness. HHV-6 and HHV-7 activation is common after lung transplantation despite ganciclovir or valganciclovir prophylaxis, but clinical manifestations are infrequently linked to them.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Technical or contaminated ethanol products are sometimes ingested either accidentally or on purpose. Typical misused products are black-market liquor and automotive products, e.g., windshield washer fluids. In addition to less toxic solvents, these liquids may contain the deadly methanol. Symptoms of even lethal solvent poisoning are often non-specific at the early stage. The present series of studies was carried out to develop a method for solvent intoxication breath diagnostics to speed up the diagnosis procedure conventionally based on blood tests. Especially in the case of methanol ingestion, the analysis method should be sufficiently sensitive and accurate to determine the presence of even small amounts of methanol from the mixture of ethanol and other less-toxic components. In addition to the studies on the FT-IR method, the Dräger 7110 evidential breath analyzer was examined to determine its ability to reveal a coexisting toxic solvent. An industrial Fourier transform infrared analyzer was modified for breath testing. The sample cell fittings were widened and the cell size reduced in order to get an alveolar sample directly from a single exhalation. The performance and the feasibility of the Gasmet FT-IR analyzer were tested in clinical settings and in the laboratory. Actual human breath screening studies were carried out with healthy volunteers, inebriated homeless men, emergency room patients and methanol-intoxicated patients. A number of the breath analysis results were compared to blood test results in order to approximate the blood-breath relationship. In the laboratory experiments, the analytical performance of the Gasmet FT-IR analyzer and Dräger 7110 evidential breath analyzer was evaluated by means of artificial samples resembling exhaled breath. The investigations demonstrated that a successful breath ethanol analysis by Dräger 7110 evidential breath analyzer could exclude any significant methanol intoxication. In contrast, the device did not detect very high levels of acetone, 1-propanol and 2-propanol in simulated breath. The Dräger 7110 evidential breath ethanol analyzer was not equipped to recognize the interfering component. According to the studies the Gasmet FT-IR analyzer was adequately sensitive, selective and accurate for solvent intoxication diagnostics. In addition to diagnostics, the fast breath solvent analysis proved feasible for controlling the ethanol and methanol concentration during haemodialysis treatment. Because of the simplicity of the sampling and analysis procedure, non-laboratory personnel, such as police officers or social workers, could also operate the analyzer for screening purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new spectral finite element formulation is presented for modeling the sloshing and the acoustic waves in nearly incompressible fluids. The formulation makes use of the Legendre polynomials in deriving the finite element interpolation shape functions in the Lagrangian frame of reference. The formulated element uses Gauss-Lobatto-Legendre quadrature scheme for integrating the volumetric stiffness and the mass matrices while the conventional Gauss-Legendre quadrature scheme is used on the rotational stiffness matrix to completely eliminate the zero energy modes, which are normally associated with the Lagrangian FE formulation. The numerical performance of the spectral element formulated here is examined by doing the inf-sup test oil a standard rectangular rigid tank partially filled with liquid The eigenvalues obtained from the formulated spectral element are compared with the conventional equally spaced node locations of the h-type Lagrangian finite element and the predicted results show that these spectral elements are more accurate and give superior convergence The efficiency and robustness of the formulated elements are demonstrated by solving few standard problems involving free vibration and dynamic response analysis with undistorted and distorted spectral elements. and the obtained results are compared with available results in the published literature (C) 2009 Elsevier Inc All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Idiopathic pulmonary fibrosis (IPF) is an interstitial lung disease with unknown aetiology and poor prognosis. IPF is characterized by alveolar epithelial damage that leads tissue remodelling and ultimately to the loss of normal lung architecture and function. Treatment has been focused on anti-inflammatory therapies, but due to their poor efficacy new therapeutic modalities are being sought. There is a need for early diagnosis and also for differential diagnostic markers for IPF and other interstitial lung diseases. The study utilized patient material obtained from bronchoalveolar lavage (BAL), diagnostic biopsies or lung transplantation. Human pulmonary fibroblast cell cultures were propagated and asbestos-induced pulmonary fibrosis in mice was used as an experimental animal model of IPF. The possible markers for IPF were scanned by immunohistochemistry, RT-PCR, ELISA and western blot. Matrix metalloproteinases (MMPs) are proteolytic enzymes that participate in tissue remodelling. Microarray studies have introduced potential markers that could serve as additional tools for the assessment of IPF and one of the most promising was MMP 7. MMP-7 protein levels were measured in the BAL fluid of patients with idiopathic interstitial lung diseases or idiopathic cough. MMP-7 was however similarly elevated in the BAL fluid of all these disorders and thus cannot be used as a differential diagnostic marker for IPF. Activation of transforming growth factor (TGF)-ß is considered to be a key element in the progression of IPF. Bone morphogenetic proteins (BMP) are negative regulators of intracellular TGF-ß signalling and BMP-4 signalling is in turn negatively regulated by gremlin. Gremlin was found to be highly upregulated in the IPF lungs and IPF fibroblasts. Gremlin was detected in the thickened IPF parenchyma and endothelium of small capillaries, whereas in non-specific interstitial pneumonia it localized predominantly in the alveolar epithelium. Parenchymal gremlin immunoreactivity might indicate IPF-type interstitial pneumonia. Gremlin mRNA levels were higher in patients with end-stage fibrosis suggesting that gremlin might be a marker for more advanced disease. Characterization of the fibroblastic foci in the IPF lungs showed that immunoreactivity to platelet-derived growth factor (PDGF) receptor-α and PDGF receptor-β was elevated in IPF parenchyma, but the fibroblastic foci showed only minor immunoreactivity to the PDGF receptors or the antioxidant peroxiredoxin II. Ki67 positive cells were also observed predominantly outside the fibroblastic foci, suggesting that the fibroblastic foci may not be composed of actively proliferating cells. When inhibition of profibrotic PDGF-signalling by imatinib mesylate was assessed, imatinib mesylate reduced asbestos-induced pulmonary fibrosis in mice as well as human pulmonary fibroblast migration in vitro but it had no effect on the lung inflammation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During inflammation, excess production and release of matrix proteinases, including matrix metalloproteinases (MMPs) and serine proteinases, may result in dysregulated extracellular proteolysis leading to development of tissue damage. Pulmonary inflammation may play an important role in the pathogenesis of lung injury in the preterm infant. The aims of this study were to evaluate involvement of MMPs and serine proteinase trypsin in acute and chronic lung injury in preterm infants and to study the role of these enzymes in acute lung injury by means of an animal model of hyperoxic lung injury. Molecular forms and levels of MMP-2, -8, and -9, and their specific inhibitor, tissue inhibitor of metalloproteinases (TIMP)-2, as well as trypsin were studied in tracheal aspirate fluid (TAF) samples collected from preterm infants with respiratory distress. Expression and distribution of trypsin-2 and proteinase-activated receptor 2 (PAR2) was examined in autopsy lung specimens from fetuses, from preterm infants with respiratory distress syndrome (RDS) or bronchopulmonary dysplasia (BPD), and from newborn infants without lung injury. We detected higher MMP-8 and trypsin-2 and lower TIMP-2 in TAF from preterm infants with more severe acute respiratory distress. Infants subsequently developing BPD had higher levels of MMP-8 and trypsin-2 early postnatally than did those who survived without this chronic lung injury. Immunohistochemically, trypsin-2 was mainly detectable in bronchial epithelium, but also in alveolar epithelium, and its expression was strongest in prolonged RDS. Since trypsin-2 is potent activator of PAR2, a G-protein coupled receptor involved in inflammation, we studied PAR2 expression in the lung. PAR2 co-localized with trypsin-2 in bronchoalveolar epithelium and its expression was significantly higher in bronchoalveolar epithelium in preterm infants with prolonged RDS than in newborn controls. In the experimental study, rats were exposed to >95% oxygen for 24, 48, and 60 hours, or room air. At 48 hours of hyperoxia, MMP-8 and trypsin levels sharply increased in bronchoalveolar lavage fluid, and expression of trypsin appeared in alveolar epithelium, and MMP-8 predominantly in macrophages. In conclusion, high pulmonary MMP-8 and trypsin-2 early postnatally are associated with severity of acute lung injury and subsequent development of BPD in preterm infants. In the injured preterm lung, trypsin-2 co-localizes with PAR2 in bronchoalveolar epithelium, suggesting that PAR2 activated by high levels of trypsin-2 is involved in lung inflammation associated with development of BPD. Marked increase in MMP-8 and trypsin early in the course of experimental hyperoxic lung injury suggests that these enzymes play a role in the pathogenesis of acute lung injury. Further exploration of the roles of trypsin and MMP-8 in lung injury may offer new targets for therapeutic intervention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transesterification of methyl butyrate, ethyl butyrate and butyl butyrate to geranyl butyrate was investigated in supercritical carbon dioxide. The effect of chain length of the butyrate on the rate of transesterification was investigated. The initial rates followed the trend: ethyl butyrate < butyl butyrate < methyl butyrate. The transesterification of butyl butyrate to geranyl butyrate in various supercritical fluids such as ethylene, methane, ethane was also examined. The initial rate of transesterification of butyl butyrate in different supercritical fluids followed the order: ScCO2 < ScC2H6 < ScC2H4 < ScCH4. The highest initial rate was obtained in supercritical methane and the reasons for this observation were proposed. The Ping-Pong Bi-Bi model with inhibition by both acid and alcohol was used to model the experimental data and determine the kinetics of the reaction. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we have studied the secondary flow induced in a micropolar fluid by the rotation of two concentric spheres about a fixed diameter. The secondary flow exhibits behaviour commonly observed in visco-elastic fluids. In particular we have obtained the expressions for microrotation vector. Numerical results have been obtained for a number of values of relative rotations of the two spheres for a chosen set of values of fluid parameters. The results are presented graphically and compared with the previous investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The micropolar fluids like Newtonian and Non-Newtonian fluids cannot sustain a simple shearing motion, wherein only one component of velocity is present. They exhibit both primary and secondary motions when the boundaries are subject to slow rotations. The primary motion, as in Non-Newtonian fluids, characterized by the equation due to Rivlin-Ericksen, Oldroyd, Walters etc., resembles that of Newtonian fluid for slow steady rotation. We further notice that the micro-rotation becomes identically equal to the vorticity present in the fluid and the condition b) of "Wall vorticity" can alone be satisfied at the boundaries. As regards, the secondary motion, we notice that it can be determined by the above procedure for a special class of fluids, namely that for which j0(n2-n3)=4 n3/l2. Moreover for this class of fluids, the micro-rotation is identical with the vorticity of the fluid everywhere. Also the stream function for the secondary flow is identical with that for the Newtonian fluid with a suitable definition of the Reynolds number. In contrast with the Non-Newtonian fluids, characterized by the equation due to Rivlin-Ericksen, Oldroyd, Walters etc., this class of micropolar fluids does not show separation. This is in conformity with the statement of Condiff and Dahler (3) that in any steady flow, internal spin matches the vorticity everywhere provided that (i) spin boundary conditions are satisfied, (ii) body torques and non-conservative body forces are absent, and (iii) inertial and spin-inertial terms are either negligible or vanish identically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper compares, in a general way, the predictions of the constitutive equations given by Rivlin and Ericksen, Oldroyd, and Walters. Whether we consider the rotational problems in cylindrical co-ordinates or in spherical polar co-ordinates, the effect of the non-Newtonicity on the secondary flows is collected in a single parameterα which can be explicitly expressed in terms of the non-Newtonian parameters that occur in each of the above-mentioned constitutive equations. Thus, for a given value ofα, all the three fluids will have identical secondary flows. It is only through the study of appropriate normal stresses that a Rivlin-Ericksen fluid can be distinguished from the other two fluids which are indistinguishable as long as this non-Newtonian parameter has the same value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper deals with the study of the nature of secondary flow of aRivlin-Ericksen fluid, contained between two concentric spheres, which perform oscillations about a fixed diameter. The steady part of the secondary flow is discussed in detail in the following three cases (i) the outer sphere at rest, the inner oscillating, (ii) the two spheres oscillating with the same angular velocity in the same sense and (iii) the spheres oscillating with the same angular velocity in opposite sense. In a previous paper, a similar problem was discussed for theOldroyd fluids. We find that the secondary flow is strongly dependent on the common frequency of oscillation of the two spheres and on the rotational nature of the motion for the present investigation also. Certain contrasting features of interest between the secondary flow field of the two fluids are also noted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data on pressure drop and heat transfer to aqueous solutions of glycerol flowing in different types of coiled pipes are presented for laminar flow in the range of NRe from 80 to 6000. An empirical correlation is set up which can account the present data as well as the data available in literature within ±10 per cent deviation. Conventional momentum and heat transfer analogy equation is used to analyse the present data.