892 resultados para air bearing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental studies on phase equilibria and liquidus in the multicomponent system PbO-ZnO-CaO-SiO2-FeO-Fe2O3 in air have been conducted over the temperature range between 1323 K (1050 degreesC) and 1623 K (1350 degreesC) to characterize the phase relations of the complex slag systems encountered in lead and zinc blast furnace sinters. The liquidus in two pseudoternary sections ZnO-Fe2O3-(PbO + CaO + SiO2) with the CaO/SiO2 weight ratio of 0.933 and PbO/(CaO + SiO2) weight ratios of 2.0 and 3.2 have been constructed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Six species of trees located in the dry sclerophyll forests of southeast Queensland were studied to ascertain which was most suitable to be retained as hollow-bearing trees for nesting and denning by arboreal marsupials. Generally for all tree species, the number of entrances to hollows was positively correlated with the diameter at breast height (DBH) and the growth stage, and entrance diameters also increased in trees with a larger DBH. However, there were differences between the species; Corymbia citriodora had few hollows until the individuals were very large while Eucalyptus crebra had low numbers of hollows throughout its entire size range. It was concluded that a mixture of tree species provided a range of hollow sizes and positions that would be suitable for nesting and denning by arboreal marsupials in those forests. There were large differences between tree species in the relationship between tree size and estimated age. Five of the tree species took between 186 and 230 years to begin to produce hollows while E. crebra took up to 324 years. This suggests that tree species other than E. crebra may be the most preferred for retention in areas where hollow-bearing tree densities are lower than the prescribed level. Other data also suggests there are likely to be enough trees in larger size classes that would begin to form hollows within the next 50 years to compensate for an expected loss of hollow-bearing stags during that same period. In terms of forest operation, the retention of six hollow-bearing trees/ha would represent an estimated loss of 7.3-15% wood production. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The European Union's (EU) decision to include aviation into the Emissions Trade Scheme was heatedly contested. Countries around the world, but mainly the Brazil, Russia, India, China and South Africa group (BRICS) and the US, denounced the EU's initiate as illegal and unilateral. Following a decade of frustrated negotiations at the International Civil Aviation Organization (ICAO), this paper interrogates why such measure, in principle climate-friendly, inspired so much global resentment. I argue that concerns with competitiveness and risks of legal inconsistency are important, but insufficient elements to explain the core of the conflict. The paper suggests that the EU was strongly criticized because third countries perceived this action as an imposed solution, which fostered an environment of distrust. Therefore, I claim that the problem has more to do with a normative divide than with a substantive divergence on what should be done regarding aviation emissions. My analysis is informed by the present literature on the links between trade and climate change, but gives particular weight to first-hand information through interviews with key stakeholders. The paper is divided in three parts. First, it presents the scope of the EU directive in historical perspective. Second, it explores the EU's measure through three different angles: legal, economical and political. The final part explores some possible solutions to overcome these divergences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fungal contamination of air in 10 gymnasiums with swimming pools was monitored. Fifty air samples of 200 L each were collected, using a Millipore air tester, from the area surrounding the pool, in training studios, in showers and changing rooms for both sexes, and also, outside premises, since these are the places regarded as reference. Simultaneously, environmental parameters – temperature and humidity – were also monitored. Some 25 different species of fungi were identified. The six most commonly isolated genera were the following: Cladosporium sp. (36.6%), Penicillium sp. (19.0%), Aspergillus sp. (10.2%), Mucor sp. (7%), Phoma sp. and Chrysonilia sp. (3.3%). For yeasts, three different genera were identified, namely, Rhodotorula sp. (70%), Trichosporon mucoides and Cryptococcus uniguttulattus (10%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A descriptive study was developed to monitor air fungal contamination in two elementary schools in Lisbon, Portugal. Eight air samples of 250 litres through impaction method were collected in canteen, library, classrooms and also, outside premises as reference place. Simultaneously, were also monitored environmental parameters, including temperature, and humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726 - 1998. Considering both schools, sixteen different species of fungi in air were identified, being the 2 most commonly isolated Cladosporium sp. (51,1%) and Penicillium sp. (27,5%). Besides these genera Trichoderma, Aspergillus, Alternaria, Chrysonilia, Botritys, Ulocladium, Athrium, Aureobasidium, Phoma, Scedosporium e Geotrichum were also isolated. Regarding yeasts, Candida sp., Cryptococcus sp. and Rhodotorula sp. were isolated. The youngest school, as well canteens in each school, presented the worst results concerning the air fungal contamination, maybe due to the higher number of occupants. There was no significant relationship (p>0,05) between fungal contamination and temperature and humidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Formaldehyde was the first air pollutant, which already in the 1970s emerged as a specifically non-industrial indoor air quality problem. Yet formaldehyde remained an indoor air quality issue and the formaldehyde level in residential indoor air is among the highest of any indoor air contaminant. Formaldehyde concentrations in 4 different indoor settings (schools, office buildings, new dwellings and occupied dwellings) in Portugal were measured using Photo Ionization Detection (PID) equipment (11,7 eV lamps). All the settings presented results higher than the reference value proposed by Portuguese legislation. Furthermore, occupied dwellings showed 3 units with results above the reference. We could conclude that formaldehyde presence is a reality in monitored indoor settings. Concentration levels are higher than the Portuguese reference value for indoor settings and these can indicate health problems for occupants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction - Microscopic filamentous fungi, under suitable environmental conditions, can lead to the production of highly toxic chemical substances, commonly known as mycotoxins. The most widespread and studied mycotoxins are metabolites of some genera of moulds such as Aspergillus, Penicillium and Fusarium. Quite peculiar conditions may influence mycotoxin biosynthesis, such as climate, geographical location, cultivation practices, storage and type of substrate. Toxicity has been extensively investigated for the most important mycotoxins, such as aflatoxins, ochratoxin A and Fusarium toxins, and much information derived from toxicokinetics in animal models has also been obtained. The adverse effects are mainly related to genotoxicity, carcinogenicity, mutagenicity, teratogenicity and immunotoxicity. Aim of the study - To identify fungal species able to produce important mycotoxins in different Portuguese settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the results of chemical concentrations inside and outside of a Lisbon (Portugal) traffic tunnel were compared, during one week. They were obtained by Instrumental Neutron Activation Analysis (INAA). The tunnel values largely exceed the Air Ambient legislated values and the Pearson Correlations Coefficients point out to soil re-suspension/dispersed road dust (As, Ce, Eu, Hf, Fe, Mo, Sc, Zn), traffic-markers (Ba, Cr), tire wear (Cr, Zn), break wear (Fe, Zn, Ba, Cu, Sb), exhaust and motor oil (Zn) and sea-spray (Br, Na). On all days these elements inside the tunnel were more enriched than outside; significant statistical differences were found for Co (p=0.005), Br (p=0.008), Zn (p=0.01) and Sb (p=0.005), while enrichment factors of As and Sc are statistically identical. The highest values were found for As, Br, Zn and Sb, for both inside and outside the tunnel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One Plus Sequential Air Sampler—Partisol was placed in a small village (Foros de Arrão) in central Portugal to collect PM10 (particles with an aerodynamic diameter below 10 μm), during the winter period for 3 months (December 2009–March 2010). Particles masses were gravimetrically determined and the filters were analyzed by instrumental neutron activation analysis to assess their chemical composition. The water-soluble ion compositions of the collected particles were determined by Ion-exchange Chromatography. Principal component analysis was applied to the data set of chemical elements and soluble ions to assess the main sources of the air pollutants. The use of both analytical techniques provided information about elemental solubility, such as for potassium, which was important to differentiate sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A descriptive study was developed to monitor air fungal contamination in ten food units from hospitals. Fifty air samples of 250 litres were collected through impaction method. Samples were collected in food storage facilities, kitchen, food plating, canteen and also, outside premises, since this is the place regarded as reference. Simultaneously, environmental parameters were also monitored, including temperature and relative humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clean air is a basic requirement of life. The Indoor Air Quality (IAQ) has been the object of several studies due to an increasing concern within the scientific community on the effects of indoor air quality upon health, especially as people tend to spend more time indoors than outdoors. The quality of air inside homes, offices, schools or other private and public buildings is an essential determinant of healthy life and people’s well-being. People can be exposed to contaminants by inhalation, ingestion and dermal contact. In the past, scientists have paid much attention to the study of exposure to outdoor air contaminants, because they have realised the seriousness of outdoor air pollution problems. However, each indoor microenvironment has unique characteristics, determined by the local outdoor air, specific building characteristics and indoor activities. Indeed, hazardous substances are emitted from buildings, construction materials and indoor equipment or due to human activities indoors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As ameaças à segurança da informação, (INFOSEC) atentam contra a perda da respectiva confidencialidade, integridade e disponibilidade, pelo que as organizações são impelidas a implementar políticas de segurança, quer ao nível físico quer ao nível lógico, utilizando mecanismos específicos de defesa. O projecto Network Air Gap Controller (NAGC) foi concebido no sentido de contribuir para as questões da segurança, designadamente daquelas que se relacionam directamente com a transferência de informação entre redes de classificação de segurança diferenciadas ou de sensibilidades distintas, sem requisitos de comunicação em tempo real, e que mereçam um maior empenho nas condições de robustez, de disponibilidade e de controlo. Os organismos que, em razão das atribuições e competências cometidas, necessitam de fazer fluir informação entre este tipo de redes, são por vezes obrigados a realizar a transferência de dados com recurso a um processo manual, efectuado pelo homem e não pela máquina, que envolve dispositivos amovivéis, como sejam o CD, DVD, PEN, discos externos ou switches manuais. Neste processo, vulgarmente designado por Network Air Gap (NAG), o responsável pela transferência de dados deverá assumir de forma infalível, como atribuições intrínsecas e inalienáveis da função exercida, as garantias do cumprimento de um vasto conjunto de normas regulamentares. As regras estabelecidas desdobram-se em ferramentas e procedimentos que se destinam, por exemplo, à guarda em arquivo de todas as transferências efectuadas; à utilização de ferramentas de segurança (ex: antivírus) antes da colocação da informação na rede de classificação mais elevada; ao não consentimento de transferência de determinados tipos de ficheiro (ex: executáveis) e à garantia de que, em consonância com a autonomia que normalmente é delegada no elemento responsável pela operação das comunicações, apenas se efectuam transferências de informação no sentido da rede de classificação inferior para a rede de classificação mais elevada. Face ao valor da informação e do impacto na imagem deste tipo de organizações, o operador de comunicações que não cumpra escrupulosamente o determinado é inexoravelmente afastado dessas funções, sendo que o processo de apuramento de responsabilidades nem sempre poderá determinar de forma inequívoca se as razões apontam para um acto deliberado ou para factores não intencionais, como a inépcia, o descuido ou a fadiga. Na realidade, as actividades periódicas e rotineiras, tornam o homem propenso à falha e poderão ser incontornavelmente asseguradas, sem qualquer tipo de constrangimentos ou diminuição de garantias, por soluções tecnológicas, desde que devidamente parametrizadas, adaptadas, testadas e amadurecidas, libertando os recursos humanos para tarefas de manutenção, gestão, controlo e inspecção. Acresce que, para este tipo de organizações, onde se multiplicam o número de redes de entrada de informação, com diferentes classificações e actores distintos, e com destinatários específicos, a utilização deste tipo de mecanismos assume uma importância capital. Devido a este factor multiplicativo, impõe-se que o NAGC represente uma opção válida em termos de oferta tecnológica, designadamente para uma gama de produtos de baixíssimo custo e que possa desenvolver-se por camadas de contributo complementar, em função das reais necessidades de cada cenário.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reactions of [ReCl2{eta(2)-N2C(O)Ph}(PPh3)(2)](1) with 2-aminopyrimidine (H(2)Npyrm), 2,2'-bipyridine (bpy) and tetraethylthiuram disulfide (tds), in MeOH upon reflux, lead to the new eta(1)-(benzoyldiazenido)-rhenium(III) complexes [ReCl{eta(1)-N2C(O)Ph}(HNpyrm)(PPh3)(2)](2)and [ReCl2{eta(1)-N2C(O)Ph}(bpy)(PPh3)] (3), and the known oxo(diethyldithiocarbamato)dirhenium(v)complex [Re2O2(mu O){Et2NC(S)S}(4)](4), respectively. The Et2NC(S)S ligands in 4 result from S-S bond rupture of tds molecules. The obtained compounds have been characterized by IR, H-1, P-31{H-1} and C-13{H-1} NMR spectroscopies, FAB(+)-MS, elemental and single-crystal X-ray diffraction (for 2 and 4)analyses. Complex 2 represents the first structurally characterized Re compound derived from 2-aminopyrimidine. Besides, the redox behaviour of 2-4 in CH2Cl2 solution has been studied by cyclic voltammetry, and the Lever electrochemical ligand parameter (E-L)has been estimated, for the first time, for HNpyrm. The electrochemical results are discussed in terms of electronic properties of the Re centres and the ligands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pressurization of hydraulic systems containing entrapped air is considered a critical condition for the infrastructure's security due to transient pressure variations often occurred. The objective of the present study is the computational evaluation of trends observed in variation of maximum surge pressure resulting from rapid pressurizations. The comparison of the results with those obtained in previous studies is also undertaken. A brief state of art in this domain is presented. This research work is applied to an experimental system having entrapped air in the top of a vertical pipe section. The evaluation is developed through the elastic model based on the method of characteristics, considering a moving liquid boundary, with the results being compared with those achieved with the rigid liquid column model.