940 resultados para X-RAY DIFFRACTOMETRY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

J Biol Inorg Chem (2007) 12:353–366 DOI 10.1007/s00775-006-0191-9

Relevância:

100.00% 100.00%

Publicador:

Resumo:

J. Am. Chem. Soc., 2004, 126 (28), pp 8614–8615 DOI: 10.1021/ja0490222

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Bioquímica, Especialidade Bioquímica Estrutural

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Bioquímica – Ramo Bioquímica Estrutural

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A thesis submitted for the degree of Ph. D. in Physics

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Scanning electron microscopy applied to the mycelial phase of Sporothrix schenckii shows a matted mycelium with conidia of a regular pattern. X-Ray microanalysis applied in energy dispersive spectroscopy and also in wavelength dispersive spectroscopy reveals the presence of several elements of Mendeleef's classification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A radiological study of the small intestine of 17 untreated patients in the acute phase ofschistosomiasis was performed. Twelve patients (70% of total) had alterations: nine had clear-cut thickening of the duodenal and jejunal folds, one flocculation, one fragmentation and one thickening of mucosae, flocculation and fragmentation of the barium column. There was no correlation of the gastrointestinal symptomatology (vomiting, diarrhoea, dysentery, hepatomegaly) neither with the parasitological load nor with the x-ray alterations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polymer based scintillator composites have been fabricated by combining poly(vinylidene fluoride) (PVDF) and Gd2O3:Eu nanoparticles (50nm). PVDF has been used since it is a flexible and stable binder matrix and highly resistance to thermal and light deterioration. Gd2O3:Eu has been selected as scintillator material due to its wide band gap, high density and suitable visible light yield. The structural, mechanical, thermal and electrical characteristics of the composites were studied as a function of filler content, together with their performance as scintillator material. The introduction of Gd2O3:Eu nanoparticles into the PVDF matrix does not influence the morphology of the polymer or the degree of crystallinity. On the other hand, an increase of the Young´s modulus with respect to PVDF matrix is observed for filler contents of 0.1-0.75 wt.%. The introduction of Gd2O3:Eu into the PVDF matrix increases dielectric constant and DC electrical conductivity as well as the visible light yield in the nanocomposite, being this increase dependent upon Gd2O3:Eu content and X-ray input power. In this way, Gd2O3:Eu/PVDF composites shows suitable characteristics to be used as X-ray radiation transducers, in particular for large area applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La idea principal del proyecto abarca el estudio de parámetros y fenómenos físicos. Los avances logrados se aplicarán al desarrollo de software y metodologías para cuantificación de materiales mediante microanálisis con sonda de electrones y microscopía electrónica de barrido. El microanálisis no es una técnica absoluta, sino que requiere de estándares de referencia, para obviar el uso de ciertos parámetros geométricos y atómicos difíciles de conocer con una precisión adecuada. Para contar con un método sin estándares debe abordarse la determinación de parámetros atómicos e instrumentales, que es uno de los aspectos que se desea encarar en este proyecto. Por otro lado, también se pretende incluir los parámetros estudiados en un software de cuantificación desarrollado por integrantes del proyecto. Otro de los propósitos del plan de trabajo es estudiar la potencialidad de la resolución espacial de una microsonda de electrones con el fin de desarrollar una metodología para caracterizar interfases, bordes de granos e inclusiones, con resolución submicrométrica, ya que los métodos tradicionales de cuantificación se restringen al caso de muestras planas y homogéneas dentro del volumen de interacción, pero la caracterización de inhomogeneidades a nivel micrométrico no ha sido desarrollada todavía, salvo algunas excepciones. The main idea of this project involves the study of physical parameters and phenomena. The concretion of the different goals will permit the elaboration of softeare and methodologies for materials characterization by means of electron probe microanalysis and scanning microscopy. Electron probe microanalysis is not an absolute technique, but requires reference standards in order not to involve certain geometrical and atomic parameters for which high uncertainties cannot be avoided. In order to have standardless method, the determination of atomic and instrumental parameters must be accomplished, as will be faced through this project. Complementary, the parameters studied will be included in a quantification software developed in our research group of FaMAF. Another objective of this activity plan is to study the spatial resolution potentiality of a focalized electron beam, with the aim of characterizing interphases, grain boundaries and inclusions with submicron sensitivity, since the traditional quantification procedures are restricted to flat homogeneous samples, whereas the characterization of inhomogeneities has not been developed yet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Maschinenbau, Diss., 2015

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The trabecular bone score (TBS, Med-Imaps, Pessac, France) is an index of bone microarchitecture texture extracted from anteroposterior dual-energy X-ray absorptiometry images of the spine. Previous studies have documented the ability of TBS of the spine to differentiate between women with and without fractures among age- and areal bone mineral density (aBMD)-matched controls, as well as to predict future fractures. In this cross-sectional analysis of data collected from 3 geographically dispersed facilities in the United States, we investigated age-related changes in the microarchitecture of lumbar vertebrae as assessed by TBS in a cohort of non-Hispanic US white American women. All subjects were 30 yr of age and older and had an L1-L4aBMDZ-score within ±2 SD of the population mean. Individuals were excluded if they had fractures, were on any osteoporosis treatment, or had any illness that would be expected to impact bone metabolism. All data were extracted from Prodigy dual-energy X-ray absorptiometry devices (GE-Lunar, Madison, WI). Cross-calibrations between the 3 participating centers were performed for TBS and aBMD. aBMD and TBS were evaluated for spine L1-L4 but also for all other possible vertebral combinations. To validate the cohort, a comparison between the aBMD normative data of our cohort and US non-Hispanic white Lunar data provided by the manufacturer was performed. A database of 619 non-Hispanic US white women, ages 30-90 yr, was created. aBMD normative data obtained from this cohort were not statistically different from the non-Hispanic US white Lunar normative data provided by the manufacturer (p = 0.30). This outcome thereby indirectly validates our cohort. TBS values at L1-L4 were weakly inversely correlated with body mass index (r = -0.17) and weight (r = -0.16) and not correlated with height. TBS values for all lumbar vertebral combinations decreased significantly with age. There was a linear decrease of 16.0% (-2.47 T-score) in TBS at L1-L4 between 45 and 90 yr of age (vs. -2.34 for aBMD). Microarchitectural loss rate increased after age 65 by 50% (-0.004 to -0.006). Similar results were obtained for other combinations of lumbar vertebra. TBS, an index of bone microarchitectural texture, decreases with advancing age in non-Hispanic US white women. Little change in TBS is observed between ages 30 and 45. Thereafter, a progressive decrease is observed with advancing age. The changes we observed in these American women are similar to that previously reported for a French population of white women (r(2) > 0.99). This reference database will facilitate the use of TBS to assess bone microarchitectural deterioration in clinical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lean meat percentage (LMP) is an important carcass quality parameter. The aim of this work is to obtain a calibration equation for the Computed Tomography (CT) scans with the Partial Least Square Regression (PLS) technique in order to predict the LMP of the carcass and the different cuts and to study and compare two different methodologies of the selection of the variables (Variable Importance for Projection — VIP- and Stepwise) to be included in the prediction equation. The error of prediction with cross-validation (RMSEPCV) of the LMP obtained with PLS and selection based on VIP value was 0.82% and for stepwise selection it was 0.83%. The prediction of the LMP scanning only the ham had a RMSEPCV of 0.97% and if the ham and the loin were scanned the RMSEPCV was 0.90%. Results indicate that for CT data both VIP and stepwise selection are good methods. Moreover the scanning of only the ham allowed us to obtain a good prediction of the LMP of the whole carcass.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rosickyite, the natural monoclinic gamma -form of sulphur, exists in only a few localities around the globe. In the old asphalt mine at La Presta, Neuchatel. Switzerland, rosickyite occurs locally as small, but very well formed crystals suitable for crystallographic studies. It grows as an alteration product of pyrite-rich asphalt. Rosickyite from La Presta mine is pure molecular sulphur, as revealed by gas chromatography-mass spectrometry. The X-ray powder diffraction data of La Presta rosickyite does not match the one previously published for this species. Therefore, a single crystal study was undertaken and a new indexed X-ray powder diffraction diagram for natural rosickyite is proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: To test the hypothesis that intervals with superior beat-to-beat coronary artery repositioning precision exist in the cardiac cycle, to design a coronary MR angiography (MRA) methodology in response, and to ascertain its performance. METHODS: Coronary repositioning precision in consecutive heartbeats was measured on x-ray coronary angiograms of 17 patients and periods with the highest repositioning precision were identified. In response, the temporal order of coronary MRA pulse sequence elements required modification and the T2 -prep now follows (T2 -post) rather than precedes the imaging part of the sequence. The performance of T2 -post was quantitatively compared (signal-to-noise [SNR], contrast-to-noise [CNR], vessel sharpness) to that of T2 -prep in vivo. RESULTS: Coronary repositioning precision is <1 mm at peak systole and in mid diastole. When comparing systolic T2 -post to diastolic T2 -prep, CNR and vessel sharpness remained unchanged (both P = NS) but SNR for muscle and blood increased by 104% and 36% (both P < 0.05), respectively. CONCLUSION: Windows with improved coronary repositioning precision exist in the cardiac cycle: one in peak systole and one in mid diastole. Peak-systolic imaging necessitates a re-design of conventional coronary MRA pulse sequences and leads to image quality very similar to that of conventional mid-diastolic data acquisition but improved SNR. J. Magn. Reson. Imaging 2015;41:1251-1258. © 2014 Wiley Periodicals, Inc.