944 resultados para Visual perception tests


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This article narrates from experiences in the classroom, the use of visual perception in the search for the solution of a basic problem of modular repetition, embodied by the lack of continuity in the elements that shape the design surface. Although Wong (1998) approach emphasizes the intuitive and intellectual approach as different parameters for building visual compositions, we list both as participants in the same focus, where the solution starts from the sensory stimulation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Visual field losses associated with mercury (Hg) exposure have only been assessed in patients exposed to methylmercury. Here we evaluate the automated visual field in 35 ex-workers (30 males; 44.20+/-5.92 years) occupationaly exposed to mercury vapor and 34 controls (21 males; 43.29+/-8.33 years). Visual fields were analyzed with the Humphrey Field Analyzer II (model 750i) using two tests: the standard automated perimetry (SAP, white-on-white) and the short wavelength automated perimetry (SWAP, blue-on-yellow) at 76 locations within a 27 degrees central visual field. Results were analyzed as the mean of the sensitivities measured at the fovea, and at five successive concentric rings, of increasing eccentricity, within the central field. Compared to controls, visual field sensitivities of the experimental group measured using SAP were lower for the fovea as well as for all five eccentricity rings (p<0.05). Sensitivities were significantly lower in the SWAP test (p<0.05) for four of the five extra-foveal eccentricity rings; they were not significant for the fovea (p = 0.584) or for the 15 degrees eccentricity ring (p = 0.965). These results suggest a widespread reduction of sensitivity in both visual field tests. Previous reports in the literature describe moderate to severe concentric constriction of the visual field in subjects with methylmercury intoxication measured manually with the Goldman perimeter. The present results amplify concerns regarding potential medical risks of exposure to environmental mercury sources by demonstrating significant and widespread reductions of visual sensitivity using the more reliable automated perimetry. (C) 2007 Elsevier Inc. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Este estudo teve como objetivo construir e conhecer os parâmetros psicométricos de um instrumento para análise da percepção visual de adultos. Para a construção da escala participaram 295 adultos saudáveis, sem déficits cognitivos ou perceptivo-visuais. Nesta etapa foi formulada uma escala tetrafatorial constituída por 20 itens que avaliam quatro dimensões referentes à percepção visual: constância da forma, figurafundo, posição e relação espacial. Para obter evidências de validade foi utilizada uma amostra de 183 voluntários com boa saúde física e mental e acuidade visual normal ou corrigida. Os dados obtidos relatam a existência de concordância interjuízes, adequação semântica e significância no teste-reteste do instrumento. Os coeficientes de fidedignidade variaram de 0,84 a 0,93. Os quatro fatores esperados foram encontrados, cada um contendo 5 itens, e juntos explicaram 57,52% da variância do constructo. O instrumento apresentou parâmetros psicométricos adequados, o que pode justificar sua utilidade em pesquisas básicas e na prática clínica.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: We aimed to investigate the performance of five different trend analysis criteria for the detection of glaucomatous progression and to determine the most frequently and rapidly progressing locations of the visual field. Design: Retrospective cohort. Participants or Samples: Treated glaucoma patients with =8 Swedish Interactive Thresholding Algorithm (SITA)-standard 24-2 visual field tests. Methods: Progression was determined using trend analysis. Five different criteria were used: (A) =1 significantly progressing point; (B) =2 significantly progressing points; (C) =2 progressing points located in the same hemifield; (D) at least two adjacent progressing points located in the same hemifield; (E) =2 progressing points in the same Garway-Heath map sector. Main Outcome Measures: Number of progressing eyes and false-positive results. Results: We included 587 patients. The number of eyes reaching a progression endpoint using each criterion was: A = 300 (51%); B = 212 (36%); C = 194 (33%); D = 170 (29%); and E = 186 (31%) (P = 0.03). The numbers of eyes with positive slopes were: A = 13 (4.3%); B = 3 (1.4%); C = 3 (1.5%); D = 2 (1.1%); and E = 3 (1.6%) (P = 0.06). The global slopes for progressing eyes were more negative in Groups B, C and D than in Group A (P = 0.004). The visual field locations that progressed more often were those in the nasal field adjacent to the horizontal midline. Conclusions: Pointwise linear regression criteria that take into account the retinal nerve fibre layer anatomy enhances the specificity of trend analysis for the detection glaucomatous visual field progression.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

New technology in the Freedom (R) speech processor for cochlear implants was developed to improve how incoming acoustic sound is processed; this applies not only for new users, but also for previous generations of cochlear implants. Aim: To identify the contribution of this technology - the Nucleus 22 (R) - on speech perception tests in silence and in noise, and on audiometric thresholds. Methods: A cross-sectional cohort study was undertaken. Seventeen patients were selected. The last map based on the Spectra (R) was revised and optimized before starting the tests. Troubleshooting was used to identify malfunction. To identify the contribution of the Freedom (R) technology for the Nucleus22 (R), auditory thresholds and speech perception tests were performed in free field in soundproof booths. Recorded monosyllables and sentences in silence and in noise (SNR = 0dB) were presented at 60 dBSPL. The nonparametric Wilcoxon test for paired data was used to compare groups. Results: Freedom (R) applied for the Nucleus22 (R) showed a statistically significant difference in all speech perception tests and audiometric thresholds. Conclusion: The reedom (R) technology improved the performance of speech perception and audiometric thresholds of patients with Nucleus 22 (R).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Este estudo teve como objetivo construir e conhecer os parâmetros psicométricos de um instrumento para análise da percepção visual de adultos. Para a construção da escala participaram 295 adultos saudáveis, sem déficits cognitivos ou perceptivo-visuais. Nesta etapa foi formulada uma escala tetrafatorial constituída por 20 itens que avaliam quatro dimensões referentes à percepção visual: constância da forma, figura-fundo, posição e relação espacial. Para obter evidências de validade foi utilizada uma amostra de 183 voluntários com boa saúde física e mental e acuidade visual normal ou corrigida. Os dados obtidos relatam a existência de concordância interjuízes, adequação semântica e significância no teste-reteste do instrumento. Os coeficientes de fidedignidade variaram de 0,84 a 0,93. Os quatro fatores esperados foram encontrados, cada um contendo 5 itens, e juntos explicaram 57,52% da variância do constructo. O instrumento apresentou parâmetros psicométricos adequados, o que pode justificar sua utilidade em pesquisas básicas e na prática clínica.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Abstract Originalsprache (englisch) Visual perception relies on a two-dimensional projection of the viewed scene on the retinas of both eyes. Thus, visual depth has to be reconstructed from a number of different cues that are subsequently integrated to obtain robust depth percepts. Existing models of sensory integration are mainly based on the reliabilities of individual cues and disregard potential cue interactions. In the current study, an extended Bayesian model is proposed that takes into account both cue reliability and consistency. Four experiments were carried out to test this model's predictions. Observers had to judge visual displays of hemi-cylinders with an elliptical cross section, which were constructed to allow for an orthogonal variation of several competing depth cues. In Experiment 1 and 2, observers estimated the cylinder's depth as defined by shading, texture, and motion gradients. The degree of consistency among these cues was systematically varied. It turned out that the extended Bayesian model provided a better fit to the empirical data compared to the traditional model which disregards covariations among cues. To circumvent the potentially problematic assessment of single-cue reliabilities, Experiment 3 used a multiple-observation task, which allowed for estimating perceptual weights from multiple-cue stimuli. Using the same multiple-observation task, the integration of stereoscopic disparity, shading, and texture gradients was examined in Experiment 4. It turned out that less reliable cues were downweighted in the combined percept. Moreover, a specific influence of cue consistency was revealed. Shading and disparity seemed to be processed interactively while other cue combinations could be well described by additive integration rules. These results suggest that cue combination in visual depth perception is highly flexible and depends on single-cue properties as well as on interrelations among cues. The extension of the traditional cue combination model is defended in terms of the necessity for robust perception in ecologically valid environments and the current findings are discussed in the light of emerging computational theories and neuroscientific approaches.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pain and the conscious mind (or the self) are experienced in our body. Both are intimately linked to the subjective quality of conscious experience. Here, we used virtual reality technology and visuo-tactile conflicts in healthy subjects to test whether experimentally induced changes of bodily self-consciousness (self-location; self-identification) lead to changes in pain perception. We found that visuo-tactile stroking of a virtual body but not of a control object led to increased pressure pain thresholds and self-location. This increase was not modulated by the synchrony of stroking as predicted based on earlier work. This differed for self-identification where we found as predicted that synchrony of stroking increased self-identification with the virtual body (but not a control object), and positively correlated with an increase in pain thresholds. We discuss the functional mechanisms of self-identification, self-location, and the visual perception of human bodies with respect to pain perception.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Several divergent cortical mechanisms generating multistability in visual perception have been suggested. Here, we investigated the neurophysiologic time pattern of multistable perceptual changes by means of a simultaneous recording with electroencephalography (EEG) and functional magnetic resonance imaging (fMRI). Volunteers responded to the subjective perception of a sudden change between stable patterns of illusionary motion (multistable transition) during a stroboscopic paradigm. We found a global deceleration of the EEG frequency prior to a transition and an occipital-accentuated acceleration after a transition, as obtained by low-resolution electromagnetic tomography analysis (LORETA) analysis. A decrease in BOLD response was found in the prefrontal cortex before, and an increase after the transitions was observed in the right anterior insula, the MT/V5 regions and the SMA. The thalamus and left superior temporal gyrus showed a pattern of decrease before and increase after transitions. No such temporal course was found in the control condition. The multimodal approach of data acquisition allows us to argue that the top-down control of illusionary visual perception depends on selective attention, and that a diminution of vigilance reduces selective attention. These are necessary conditions to allow for the occurrence of a perception discontinuity in absence of a physical change of the stimulus.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Zeki and co-workers recently proposed that perception can best be described as locally distributed, asynchronous processes that each create a kind of microconsciousness, which condense into an experienced percept. The present article is aimed at extending this theory to metacognitive feelings. We present evidence that perceptual fluency-the subjective feeling of ease during perceptual processing-is based on speed of processing at different stages of the perceptual process. Specifically, detection of briefly presented stimuli was influenced by figure-ground contrast, but not by symmetry (Experiment 1) or the font (Experiment 2) of the stimuli. Conversely, discrimination of these stimuli was influenced by whether they were symmetric (Experiment 1) and by the font they were presented in (Experiment 2), but not by figure-ground contrast. Both tasks however were related with the subjective experience of fluency (Experiments 1 and 2). We conclude that subjective fluency is the conscious phenomenal correlate of different processing stages in visual perception.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Visual neglect is a frequent disability in stroke and adversely affects mobility, discharge destination, and length of hospital stay. It is assumed that its severity is enhanced by a released interhemispheric inhibition from the unaffected toward the affected hemisphere. Continuous theta burst transcranial magnetic stimulation (TBS) is a new inhibitory brain stimulation protocol which has the potential to induce behavioral effects outlasting stimulation. We aimed to test whether parietal TBS over the unaffected hemisphere can induce a long-lasting improvement of visual neglect by reducing the interhemispheric inhibition. METHODS: Eleven patients with left-sided visual neglect attributable to right hemispheric stroke were tested in a visual perception task. To evaluate the specificity of the TBS effect, 3 conditions were tested: 2 TBS trains over the left contralesional posterior parietal cortex, 2 trains of sham stimulation over the contralesional posterior parietal cortex, and a control condition without any intervention. To evaluate the lifetime of repeated trains of TBS in 1 session, 4 trains were applied over the contralesional posterior parietal cortex. RESULTS: Two TBS trains significantly increased the number of perceived left visual targets for up to 8 hours as compared to baseline. No significant improvement was found with sham stimulation or in the control condition without any intervention. The application of 4 TBS trains significantly increased the number of perceived left targets up to 32 hours. CONCLUSIONS: The new approach of repeating TBS at the same day may be promising for therapy of neglect.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We seek to determine the relationship between threshold and suprathreshold perception for position offset and stereoscopic depth perception under conditions that elevate their respective thresholds. Two threshold-elevating conditions were used: (1) increasing the interline gap and (2) dioptric blur. Although increasing the interline gap increases position (Vernier) offset and stereoscopic disparity thresholds substantially, the perception of suprathreshold position offset and stereoscopic depth remains unchanged. Perception of suprathreshold position offset also remains unchanged when the Vernier threshold is elevated by dioptric blur. We show that such normalization of suprathreshold position offset can be attributed to the topographical-map-based encoding of position. On the other hand, dioptric blur increases the stereoscopic disparity thresholds and reduces the perceived suprathreshold stereoscopic depth, which can be accounted for by a disparity-computation model in which the activities of absolute disparity encoders are multiplied by a Gaussian weighting function that is centered on the horopter. Overall, the statement "equal suprathreshold perception occurs in threshold-elevated and unelevated conditions when the stimuli are equally above their corresponding thresholds" describes the results better than the statement "suprathreshold stimuli are perceived as equal when they are equal multiples of their respective threshold values."

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Each year, some two million people in the United Kingdom experience visual hallucinations. Infrequent, fleeting visual hallucinations, often around sleep, are a usual feature of life. In contrast, consistent, frequent, persistent hallucinations during waking are strongly associated with clinical disorders; in particular delirium, eye disease, psychosis, and dementia. Research interest in these disorders has driven a rapid expansion in investigatory techniques, new evidence, and explanatory models. In parallel, a move to generative models of normal visual function has resolved the theoretical tension between veridical and hallucinatory perceptions. From initial fragmented areas of investigation, the field has become increasingly coherent over the last decade. Controversies and gaps remain, but for the first time the shapes of possible unifying models are becoming clear, along with the techniques for testing these. This book provides a comprehensive survey of the neuroscience of visual hallucinations and the clinical techniques for testing these. It brings together the very latest evidence from cognitive neuropsychology, neuroimaging, neuropathology, and neuropharmacology, placing this within current models of visual perception. Leading researchers from a range of clinical and basic science areas describe visual hallucinations in their historical and scientific context, combining introductory information with up-to-date discoveries. They discuss results from the main investigatory techniques applied in a range of clinical disorders. The final section outlines future research directions investigating the potential for new understandings of veridical and hallucinatory perceptions, and for treatments of problematic hallucinations. Fully comprehensive, this is an essential reference for clinicians in the fields of the psychology and psychiatry of hallucinations, as well as for researchers in departments, research institutes and libraries. It has strong foundations in neuroscience, cognitive science, optometry, psychiatry, psychology, clinical medicine, and philosophy. With its lucid explanation and many illustrations, it is a clear resource for educators and advanced undergraduate and graduate students.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Brain lesions in the visual associative cortex are known to impair visual perception, i.e., the capacity to correctly perceive different aspects of the visual world, such as motion, color, or shapes. Visual perception can be influenced by non-invasive brain stimulation such as transcranial direct current stimulation (tDCS). In a recently developed technique called high definition (HD) tDCS, small HD-electrodes are used instead of the sponge electrodes in the conventional approach. This is believed to achieve high focality and precision over the target area. In this paper we tested the effects of cathodal and anodal HD-tDCS over the right V5 on motion and shape perception in a single blind, within-subject, sham controlled, cross-over trial. The purpose of the study was to prove the high focality of the stimulation only over the target area. Twenty one healthy volunteers received 20 min of 2 mA cathodal, anodal and sham stimulation over the right V5 and their performance on a visual test was recorded. The results showed significant improvement in motion perception in the left hemifield after cathodal HD-tDCS, but not in shape perception. Sham and anodal HD-tDCS did not affect performance. The specific effect of influencing performance of visual tasks by modulating the excitability of the neurons in the visual cortex might be explained by the complexity of perceptual information needed for the tasks. This provokes a "noisy" activation state of the encoding neuronal patterns. We speculate that in this case cathodal HD-tDCS may focus the correct perception by decreasing global excitation and thus diminishing the "noise" below threshold.