977 resultados para Vision, Ocular


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The optometric profession in the UK has a major role in the detection, assessment and management of ocular anomalies in children between 5 and 16 years of age. The role complements a variety of associated screening services provided across several health care sectors. The review examines the evidence-base for the content, provision and efficacy of these screening services in terms of the prevalence of anomalies such as refractive error, amblyopia, binocular vision and colour vision and considers the consequences of their curtailment. Vision screening must focus on pre-school children if the aim of the screening is to detect and treat conditions that may lead to amblyopia, whereas if the aim is to detect and correct significant refractive errors (not likely to lead to amblyopia) then it would be expedient for the optometric profession to act as the major provider of refractive (and colour vision) screening at 5-6 years of age. Myopia is the refractive error most likely to develop during primary school presenting typically between 8 and 12 years of age, thus screening at entry to secondary school is warranted. Given the inevitable restriction on resources for health care, establishing screening at 5 and 11 years of age, with exclusion of any subsequent screening, is the preferred option. © 2004 The College of Optometrists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. High myopia in childhood is associated with important ocular and systemic conditions. However in the UK, high myopia in early childhood is not specifically identified in current ophthalmology, optometry, or orthoptic protocols for screening, referral, or investigation. An ongoing study in the West Midlands, UK, is investigating high myopia presenting to community health care clinics with the aim of compiling guidelines for assessment and subsequent referral. Methods. Children with high myopia were identified from community optometric and orthoptic sources and invited for an ophthalmology and optometry examination to ascertain possible ocular or systemic disease. Results. High myopia with no associated ocular or systemic condition was present in 15 (56%) of the children. In seven children (25%), associated ocular problems were found including unrecognized retinal dystrophies and amblyopia. Systemic disorders associated with high myopia were found in five children (19%) and included Sticklers syndrome, Weill-Marchesani syndrome, and homocystinuria. In one child, the diagnosis made before this study was found to be incorrect, and in another child, the results were inconclusive. In two cases, the diagnosis of a systemic condition in the child led to the identification of the disease in at least one relative. Conclusions. There is a high prevalence of ocular and systemic abnormality in young children seen in the community. Optometric and ophthalmologic assessment of children less than 10 years with myopia ≥5 D is likely to identify significant ocular or systemic disease, a proportion of which will respond to medical intervention. Detection and prompt referral of these cases by community health care services may be expected to prolong vision and possibly life expectancy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work was to investigate human contrast perception at various contrast levels ranging from detection threshold to suprathreshold levels by using psychophysical techniques. The work consists of two major parts. The first part deals with contrast matching, and the second part deals with contrast discrimination. Contrast matching technique was used to determine when the perceived contrasts of different stimuli were equal. The effects of spatial frequency, stimulus area, image complexity and chromatic contrast on contrast detection thresholds and matches were studied. These factors influenced detection thresholds and perceived contrast at low contrast levels. However, at suprathreshold contrast levels perceived contrast became directly proportional to the physical contrast of the stimulus and almost independent of factors affecting detection thresholds. Contrast discrimination was studied by measuring contrast increment thresholds which indicate the smallest detectable contrast difference. The effects of stimulus area, external spatial image noise and retinal illuminance were studied. The above factors affected contrast detection thresholds and increment thresholds measured at low contrast levels. At high contrast levels, contrast increment thresholds became very similar so that the effect of these factors decreased. Human contrast perception was modelled by regarding the visual system as a simple image processing system. A visual signal is first low-pass filtered by the ocular optics. This is followed by spatial high-pass filtering by the neural visual pathways, and addition of internal neural noise. Detection is mediated by a local matched filter which is a weighted replica of the stimulus whose sampling efficiency decreases with increasing stimulus area and complexity. According to the model, the signals to be compared in a contrast matching task are first transferred through the early image processing stages mentioned above. Then they are filtered by a restoring transfer function which compensates for the low-level filtering and limited spatial integration at high contrast levels. Perceived contrasts of the stimuli are equal when the restored responses to the stimuli are equal. According to the model, the signals to be discriminated in a contrast discrimination task first go through the early image processing stages, after which signal dependent noise is added to the matched filter responses. The decision made by the human brain is based on the comparison between the responses of the matched filters to the stimuli, and the accuracy of the decision is limited by pre- and post-filter noises. The model for human contrast perception could accurately describe the results of contrast matching and discrimination in various conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The work utilising a new material for contact lenses has fallen into three parts: Physioloeical considerations: Since the cornea is devoid of blood vessels, its oxygen is derived from the atmosphere. Early hydrophilic gel contact lenses interrupted the flow of oxygen and corneal insult resulted. Three techniques of fenestration were tried to overcome this problem. High speed drilling with 0.1 mm diameter twist drills. was found to be mechanically successful, but under clinical conditions mucous blockage of the fenestrations occurred. An investigation was made into the amount of oxygen arriving at the corneal interface; related to gel lens thickness. The results indicated an improvement in corneal oxygen as lens thickness was reduced. The mechanism is thought to be a form of mechanical pump. A series of clinical studies con:firmed the experimental work; the use of thin lenses removing the symptoms of corneal hypoxia. Design: The parameters of lens back curvature. lens thickness and lens diameter have been isolated and related to three criteria of vision (a) Visual acuity. (b) Visual stability and (c) Induced astigmatism. From the results achieved a revised and basically successful design of lens has been developed. Comparative study: The developed form of lens was compared with traditional lenses in a controlled survey. Twelve factors were assessed over a twenty week period of wear using a total of eighty four patients. The results of this study indicate that whilst the expected changes were noted with the traditional lens wearers, gel lens wearers showed no discernible change in any of the factors measured. ldth the exception of' one parameter. In addition to a description of' the completed l'iork. further investigations are ·sug~ested l'lhich. it is hoped. l'iould further improve the optical performance of gel lenses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In human (D. H. Baker, T. S. Meese, & R. J. Summers, 2007b) and in cat (B. Li, M. R. Peterson, J. K. Thompson, T. Duong, & R. D. Freeman, 2005; F. Sengpiel & V. Vorobyov, 2005) there are at least two routes to cross-orientation suppression (XOS): a broadband, non-adaptable, monocular (within-eye) pathway and a more narrowband, adaptable interocular (between the eyes) pathway. We further characterized these two routes psychophysically by measuring the weight of suppression across spatio-temporal frequency for cross-oriented pairs of superimposed flickering Gabor patches. Masking functions were normalized to unmasked detection thresholds and fitted by a two-stage model of contrast gain control (T. S. Meese, M. A. Georgeson, & D. H. Baker, 2006) that was developed to accommodate XOS. The weight of monocular suppression was a power function of the scalar quantity ‘speed’ (temporal-frequency/spatial-frequency). This weight can be expressed as the ratio of non-oriented magno- and parvo-like mechanisms, permitting a fast-acting, early locus, as befits the urgency for action associated with high retinal speeds. In contrast, dichoptic-masking functions superimposed. Overall, this (i) provides further evidence for dissociation between the two forms of XOS in humans, and (ii) indicates that the monocular and interocular varieties of XOS are space/time scale-dependent and scale-invariant, respectively. This suggests an image-processing role for interocular XOS that is tailored to natural image statistics—very different from that of the scale-dependent (speed-dependent) monocular variety.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Golfers, coaches and researchers alike, have all keyed in on golf putting as an important aspect of overall golf performance. Of the three principle putting tasks (green reading, alignment and the putting action phase), the putting action phase has attracted the most attention from coaches, players and researchers alike. This phase includes the alignment of the club with the ball, the swing, and ball contact. A significant amount of research in this area has focused on measuring golfer’s vision strategies with eye tracking equipment. Unfortunately this research suffers from a number of shortcomings, which limit its usefulness. The purpose of this thesis was to address some of these shortcomings. The primary objective of this thesis was to re-evaluate golfer’s putting vision strategies using binocular eye tracking equipment and to define a new, optimal putting vision strategy which was associated with both higher skill and success. In order to facilitate this research, bespoke computer software was developed and validated, and new gaze behaviour criteria were defined. Additionally, the effects of training (habitual) and competition conditions on the putting vision strategy were examined, as was the effect of ocular dominance. Finally, methods for improving golfer’s binocular vision strategies are discussed, and a clinical plan for the optometric management of the golfer’s vision is presented. The clinical management plan includes the correction of fundamental aspects of golfers’ vision, including monocular refractive errors and binocular vision defects, as well as enhancement of their putting vision strategy, with the overall aim of improving performance on the golf course. This research has been undertaken in order to gain a better understanding of the human visual system and how it relates to the sport performance of golfers specifically. Ultimately, the analysis techniques and methods developed are applicable to the assessment of visual performance in all sports.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE. To examine the relation between ocular surface temperature (OST) assessed by dynamic thermal imaging and physical parameters of the anterior eye in normal subjects. METHODS. Dynamic ocular thermography (ThermoTracer 7102MX) was used to record body temperature and continuous ocular surface temperature for 8 s after a blink in the right eyes of 25 subjects. Corneal thickness, corneal curvature, and anterior chamber depth (ACD) were assessed using Orbscan II; noninvasive tear break-up time (NIBUT) was assessed using the tearscope; slit lamp photography was used to record tear meniscus height (TMH) and objective bulbar redness. RESULTS. Initial OST after a blink was significantly correlated only with body temperature (r = 0.80, p < 0.0005), NIBUT (r = -0.68, p < 0.005) and corneal curvature (r = -0.40, p = 0.05). A regression model containing all the variables accounted for 70% (p = 0.002) of the variance in OST, of which NIBUT (29%, p = 0.004), and body temperature (18%, p = 0.005) contributed significantly. CONCLUSIONS. The results support previous theoretical models that OST radiation is principally related to the tear film; and demonstrate that it is less related to other characteristics such as corneal thickness, corneal curvature, and anterior chamber depth. © 2007 American Academy of Optometry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. The purpose of this study was to evaluate the longitudinal changes in ocular physiology, tear film characteristics, and symptomatology experienced by neophyte silicone hydrogel (SiH) contact lens wearers in a daily-wear compared with a continuous-wear modality and with the different commercially available lenses over an 18-month period. Methods. Forty-five neophyte subjects were enrolled in the study and randomly assigned to wear one of two SiH materials: lotrafilcon A or balafilcon A lenses on either a daily- (LDW; BDW) or continuous-wear (LCW; BCW) basis. Additionally, a group of noncontact lens-wearing subjects (control group) was also recruited and followed over the same study period. Objective and subjective grading of ocular physiology were carried out together with tear meniscus height (TMH) and noninvasive tear breakup time (NITBUT). Subjects also subjectively rated symptoms and judgments with lens wear. After initial screening, subsequent measurements were taken after 1, 3, 6, 12, and 18 months. Results. Subjective and objective grading of ocular physiology revealed a small increase in bulbar, limbal, and palpebral hyperemia as well as corneal staining over time with both lens materials and regimes of wear (p < 0.05). No significant changes in NITBUT or TMH were found (p > 0.05). Subjective symptoms and judgment were not material- or modality-specific. Conclusions. Daily and continuous wear of SiH contact lenses induced small but statistically significant changes in ocular physiology and symptomatology. Clinical measures of tear film characteristics were unaffected by lens wear. Both materials and regimes of wear showed similar clinical performance. Long-term SiH contact lens wear is shown to be a successful option for patients. Copyright © 2006 American Academy of Optometry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: In golf, the impact of eye-hand dominance on putting performance has long been debated. Eye-hand dominance is thought to impact how golfers judge the alignment of the ball with the target and the club with the ball, as well as how golfers visualize the line of the putt when making decisions about the force needed to hit the ball. Previous studies have all measured ocular dominance in primary gaze only, despite golfers spending a significant amount of their time in a putting stance (bent at the hips, head tilted down). Thus, the purpose of this study was to assess ocular dominance in both primary gaze (aligning the ball with the target) and putting gaze (addressing the ball and aligning the club). Methods: This study investigatedmeasuring pointing oculardominance in both primary and putting gaze positions on 31 golfers (14 amateur, 7 club professionals, and 10 top professionals). All playerswere right-handed golfers, although one reported having no hand dominance and one reported being strongly left hand dominant. Results: The results showed that (1) primary and putting gaze ocular dominances are not equal, nor are they predictive of each other; (2) themagnitude of putting ocular dominance is significantly less than themagnitude of primary gaze ocular dominance; (3) ocular dominance is not correlated with handedness in either primary or putting gaze; and (4) eye-hand dominance is not associated with increased putting skill, although ocular dominance may be associated with increased putting success. Conclusions: It is important that coaches assess golfers' ocular dominance in both primary and putting gaze positions to ensure they have the most accurate information upon which to base their vision strategy decisions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Since 1972, the Australian College of Optometry has worked in partnership with Vision Australia to provide multidisciplinary low-vision care at the Kooyong Low Vision Clinic. In 1999, Wolffsohn and Cochrane reported on the demographic characteristics of patients attending Kooyong. Sixteen years on, the aim of this study is to review the demographics of the Kooyong patient cohort and prescribing patterns. METHODS: Records of all new patients (n = 155) attending the Kooyong Low Vision Clinic for optometry services between April and September 2012 were retrospectively reviewed. RESULTS: Median age was 84.3 years (range 7.7 to 98.1 years) with 59 per cent female. The majority of patients presented with late-onset degenerative pathology, 49 per cent with a primary diagnosis of age-related macular degeneration. Many (47.1 per cent) lived with their families. Mean distance visual acuity was 0.57 ± 0.47 logMAR or approximately 6/24. The median spectacle-corrected near visual acuity was N8 (range N3 to worse than N80). Fifty patients (32.3 per cent) were prescribed new spectacles, 51 (32.9 per cent) low vision aids and five (8.3 per cent) were prescribed electronic magnification devices. Almost two-thirds (63.9 per cent) were referred for occupational therapy management and 12.3 per cent for orientation and mobility services. CONCLUSIONS: The profile of patients presenting for low-vision services at Kooyong is broadly similar to that identified in 1999. Outcomes appear to be similar, aside from an expected increase in electronic devices and technological solutions; however, the nature of services is changing, as treatments for ocular diseases advance and assistive technology develops and becomes more accessible. Alongside the aging population and age-related ocular disease being the predominant cause of low vision in Australia, the health-funding landscape is becoming more restrictive. The challenge for the future will be to provide timely, high-quality care in an economically efficient model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Biotribology is essentially the study of friction, lubrication and wear in biological systems. The area has been widely studied in relation to the behaviour of synovial joints and the design and behaviour of hip joint prostheses, but only in the last decade have serious studies been extended to the eye. In the ocular environment - as distinct from articular joints - wear is not a major factor. Both lubrication and friction are extremely important, however; this is particularly the case in the presence of the contact lens, which is a medical device important not only in vision correction but also as a therapeutic bandage for the compromised cornea. This chapter describes the difficulty in replicating experimental conditions that accurately reflect the complex nature of the ocular environment together with the factors such as load and rate of travel of the eyelid, which is the principal moving surface in the eye. Results obtained across a range of laboratories are compared.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To determine the prevalence of ocular findings of the external structures and anterior segment of the eye, detected by biomicroscopic examination in schoolchildren in Natal (RN) - Brazil. Methods: After previous random selection, 1,024 pupils from elementary and secondary public and private schools in the city of Natal were evaluated from March to June 2001. All were submitted to preestablished standard research norms, consisting of identification, demographic information, ophthalmologic biomicroscopic examination, with slit lamp, performed by ophthalmologists from the “Onofre Lopes” University Hospital. Results: Alterations of the conjunctival and palpebral conditions were the most prevalent (10.4% and 6.2% respectively). Follicles (4.2%) and papillae (3.0%) were the frequent conjunctival lesions, while blepharitis (3.5%) and meibomitis (1.1%) were the most detected abnormalities in the eyelids. Upon examining the cornea, iris, lens and anterior vitreous, the most encountered findings were nubecula (0.5%), papillary membrane reliquiae (0.5%), posterior capsula opacity (0.8%) and hyaloid arteria reliquiae (2.0%). Conclusion: The most prevalent findings affecting the external structures of the eye such as eyelids and conjunctiva, consisted of blepharitis followed by follicular reaction of the conjunctiva. The most prevalent abnormalities in the cornea, iris, lens and anterior vitreous were nubecula, papillary membrane reliquiae, posterior capsular opacity and hyaloid arteria reliquiae, in that order

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose Microcephaly with or without chorioretinopathy, lymphedema or intellectual disability (MCLID) is an autosomal dominant condition. Mutations in KIF11 have been found to be causative in approximately 75% of cases. This study describes the ocular phenotype in patients with confirmed KIF11 mutations. Methods Standard ophthalmic examination and investigation including visual acuity, refraction and fundus examination was carried out in all patients. Fundus autofluorescence imaging (FAF) was performed in three patients, and four patients underwent spectral domain optical coherence tomography (OCT). Flash electroretinography (ERG) was performed in seven patients, and five underwent additional pattern electroretinography (PERG). Results The patients ranged in age from 2 to 10 years. Most presented with visual acuity loss. Fundus examination revealed lacunae of chorioretinal atrophy. Pigmentary macular changes and optic disc pallor were present in three of seven patients. Fundus autofluorescence demonstrated hypoautofluorescence at the macula in two of three patients. The lacunae of chorioretinal atrophy were hypoautofluorescent. The OCT showed atrophic maculae in three of four patients. Follow-up in one patient showed no deterioration of the vision over a 9-year period. The lesions appear not to be progressive on the follow-up imaging. Electrophysiology showed generalized rod and cone dysfunction and severe macular dysfunction. Inner retinal dysfunction was evident in three of seven patients. Conclusions Patients with KIF11 mutations show a specific ocular phenotype with variable expressivity and intrafamilial variability. Macular atrophy and dysfunction have not been consistently documented before. The fundus lesions appear non-progressive. The findings assist in providing an accurate diagnosis and thus improving the management and follow-up of patients with this syndrome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias de la Visión).-- Universidad de La Salle. Maestría en Ciencias de la Visión, 2014

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To determine the prevalence of ocular findings of the external structures and anterior segment of the eye, detected by biomicroscopic examination in schoolchildren in Natal (RN) - Brazil. Methods: After previous random selection, 1,024 pupils from elementary and secondary public and private schools in the city of Natal were evaluated from March to June 2001. All were submitted to preestablished standard research norms, consisting of identification, demographic information, ophthalmologic biomicroscopic examination, with slit lamp, performed by ophthalmologists from the “Onofre Lopes” University Hospital. Results: Alterations of the conjunctival and palpebral conditions were the most prevalent (10.4% and 6.2% respectively). Follicles (4.2%) and papillae (3.0%) were the frequent conjunctival lesions, while blepharitis (3.5%) and meibomitis (1.1%) were the most detected abnormalities in the eyelids. Upon examining the cornea, iris, lens and anterior vitreous, the most encountered findings were nubecula (0.5%), papillary membrane reliquiae (0.5%), posterior capsula opacity (0.8%) and hyaloid arteria reliquiae (2.0%). Conclusion: The most prevalent findings affecting the external structures of the eye such as eyelids and conjunctiva, consisted of blepharitis followed by follicular reaction of the conjunctiva. The most prevalent abnormalities in the cornea, iris, lens and anterior vitreous were nubecula, papillary membrane reliquiae, posterior capsular opacity and hyaloid arteria reliquiae, in that order