947 resultados para Ventilation mécanique


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using a before and after study design, we compared protocolised weaning from mechanical ventilation with usual non-protocolised practice in intensive care. Outcomes (duration of mechanical ventilation, duration of intubation, intensive care stay) and complications (re-intubations, tracheostomy, mortality) were compared between baseline (Phase I) and following implementation of protocolised weaning (Phase II). Over the same period, we collected data in a second (reference) unit to monitor practice changes over time. In the intervention unit, outcomes were longer in Phase II compared with Phase I (all p < 0.005). When adjusted for admission APACHE II score and diagnostic category, only intensive care stay remained significantly longer (p = 0.002). There were significantly more tracheostomies in Phase II (p = 0.004). The reference unit demonstrated no statistically significant differences in study outcomes or complications between Phases. Protocolised weaning did not reduce the duration of mechanical ventilation and was not associated with an increased rate of re-intubation or intensive care unit mortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study which shows that 10-11 yr olds are capable of effective CPR after a single 2 hour training session using the ABC for Life programme. However they perfrom more effective CPR when using a ratio of 15:2 rather than 30:2 chest compressions : ventilations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective
Preliminary assessment of an automated weaning system (SmartCare™/PS) compared to usual management of weaning from mechanical ventilation performed in the absence of formal protocols.


Design and setting
A randomised, controlled pilot study in one Australian intensive care unit.


Patients
A total of 102 patients were equally divided between SmartCare/PS and Control.

Interventions
The automated system titrated pressure support, conducted a spontaneous breathing trial and provided notification of success (“separation potential”).

Measurements and results
The median time from the first identified point of suitability for weaning commencement to the state of “separation potential” using SmartCare/PS was 20 h (interquartile range, IQR, 2–40) compared to 8 h (IQR 2–43) with Control (log-rank P = 0.3). The median time to successful extubation was 43 h (IQR 6–169) using SmartCare/PS and 40 (14–87) with Control (log-rank P = 0.6). Unadjusted, the estimated probability of reaching “separation potential” was 21% lower (95% CI, 48% lower to 20% greater) with SmartCare/PS compared to Control. Adjusted for other covariates (age, gender, APACHE II, SOFAmax, neuromuscular blockade, corticosteroids, coma and elevated blood glucose), these estimates were 31% lower (95% CI, 56% lower to 9% greater) with SmartCare/PS. The study groups showed comparable rates of reintubation, non-invasive ventilation post-extubation, tracheostomy, sedation, neuromuscular blockade and use of corticosteroids.

Conclusions
Substantial reductions in weaning duration previously demonstrated were not confirmed when the SmartCare/PS system was compared to weaning managed by experienced critical care specialty nurses, using a 1:1 nurse-to-patient ratio. The effect of SmartCare/PS may be influenced by the local clinical organisational context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Lung protective ventilation has been widely adopted for the management of acute lung injury (ALI) and acute respiratory distress syndrome ( ARDS). Consequently, ventilator associated lung injury and mortality have decreased. It is not known if this ventilation strategy changes the prognostic value of previously identified demographic and pulmonary predictors of mortality, such as respiratory compliance and the arterial oxygen tension to inspired oxygen fraction ratio (Pao(2)/Fio(2)).