817 resultados para Vector sensor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over 60,500 dengue cases were reported in the state of Espírito Santo (ES), Brazil, between 1995 and 1998. The study's purpose was to identify whether Aedes albopictus was transmitting the dengue virus during an epidemic in the locality of Vila Bethânia (Viana County),Vitória, ES. From April 3 to 9, 1998, blood and serum samples were collected daily for virus isolation and serological testing. Four autochthonous cases were confirmed through DEN 1 virus isolation and two autochthonous cases through MAC ELISA testing. Of 37 Ae. aegypti and 200 Ae. albopictus adult mosquitoes collected and inoculated, DEN1 virus was isolated only from a pool of two Ae. aegypti female mosquitoes. The study results suggest that Ae. albopictus still cannot be considered an inter-human vector in dengue epidemics in Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação tem como finalidade apresentar uma investigação teórica e experimental sobre um sensor polarimétrico, portátil e de baixo custo, baseado num cristal líquido para a medição da concentração de glicose existente numa amostra. Devido ao crescente número de pessoas que sofrem de Diabetes, existe grande interesse em desenvolver sensores portáteis que permitam medir a concentração de glicose de forma rápida, precisa e indolor. Dos vários métodos não invasivos existentes para a medição de concentração de glicose, o método utilizado tem como base a medição da rotação da polarização da luz. Recentemente os sensores polarimétricos baseados em cristais líquidos, têm adquirido grande ênfase devido às suas características únicas que, em comparação com outros moduladores electroópticos, funcionam com tensões mais baixas, apresentam menor consumo energético e maior ângulo de rotação. No entanto também existem diversas desvantagens, nomeadamente a falta de documentação sobre a realização de testes e resultados obtidos em sensores polarimétricos. Têm como desvantagem adicional o facto do comportamento do polarímetro ser fortemente dependente do tipo de cristal líquido e da tensão a este aplicado. A presente dissertação descreve o desenvolvimento de um sensor polarimétrico que inclui a componente óptica, a componente electrónica de detecção e acondicionamento do sinal, a comunicação sem fios com um PC, e, por fim, a componente de análise e interface com o utilizador. Neste sensor polarimétrico poderão ser efectuadas leituras de temperatura das amostras para efeitos de correcção do cálculo da concentração da glicose. O dispositivo permite ainda a gravação dos dados obtidos e identificação dos mesmos. Os resultados obtidos demonstram que o dispositivo é capaz de medir concentrações com 10mg/ml de glicose, com uma percentagem de erro de 15%, para uma amostra com um percurso óptico de apenas 1 cm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Toxic amides, such as acrylamide, are potentially harmful to Human health, so there is great interest in the fabrication of compact and economical devices to measure their concentration in food products and effluents. The CHEmically Modified Field Effect Transistor (CHEMFET) based onamorphous silicon technology is a candidate for this type of application due to its low fabrication cost. In this article we have used a semi-empirical modelof the device to predict its performance in a solution of interfering ions. The actual semiconductor unit of the sensor was fabricated by the PECVD technique in the top gate configuration. The CHEMFET simulation was performed based on the experimental current voltage curves of the semiconductor unit and on an empirical model of the polymeric membrane. Results presented here are useful for selection and design of CHEMFET membranes and provide an idea of the limitations of the amorphous CHEMFET device. In addition to the economical advantage, the small size of this prototype means it is appropriate for in situ operation and integration in a sensor array.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presença de sistemas eletrónicos nos veículos automóveis tem vindo a aumentar de forma considerável nos últimos 30 anos, tornando possível o aumento dos padrões de eficiência, segurança e conforto dos mesmos. Os sistemas de acionamento automático dos limpa-para-brisas, baseados em sensores de chuva óticos, têm registado um crescimento quase exponencial nos últimos 10 a 15 anos; no ano 2000, apenas 5 % dos veículos novos produzidos na Europa estavam equipados com este sistema, hoje é um equipamento amplamente difundido na oferta automóvel existente. O presente trabalho consistiu no estudo de uma solução para deteção de chuva em veículos automóveis com a aplicação de um sensor piezoelétrico, tendo em vista a obtenção de uma solução mais versátil e aplicável em vários pontos do veículo. As reduzidas dimensões, a elevada sensibilidade do sensor e a facilidade de aplicação nas superfícies de ensaio foram fatores que motivaram a escolha deste tipo de equipamento como elemento sensorial. As hipóteses definidas para o procedimento laboratorial basearam-se nas conclusões obtidas em estudos anteriormente desenvolvidos no campo dos sensores de chuva para automóveis e nas capacidades dos materiais piezoelétricos para medição de pluviosidade. Os sensores foram instalados sob as superfícies do veículo que apresentavam, simultaneamente, uma maior exposição à pluviosidade, quando este está em movimento, e um menor risco de sofrer danos. Os resultados obtidos permitiram concluir que a utilização deste tipo de sensores permite detetar elevados níveis de pluviosidade e em superfícies com considerável capacidade de deformação elástica. A sua implementação futura em veículos automóveis exige mais algum trabalho de melhoria dos processos de fixação dos sensores e do condicionamento de sinal utilizados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is a contribution for the assessment and comparison of magnet properties based on magnetic field characteristics particularly concerning the magnetic induction uniformity in the air gaps. For this aim, a solver was developed and implemented to determine the magnetic field of a magnetic core to be used in Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometry. The electromagnetic field computation is based on a 2D finite-element method (FEM) using both the scalar and the vector potential formulation. Results for the magnetic field lines and the magnetic induction vector in the air gap are presented. The target magnetic induction is 0.2 T, which is a typical requirement of the FFC NMR technique, which can be achieved with a magnetic core based on permanent magnets or coils. In addition, this application requires high magnetic induction uniformity. To achieve this goal, a solution including superconducting pieces is analyzed. Results are compared with a different FEM program.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pi'n/pin a-SiC:H voltage and optical bias controlled device is presented and its behavior as image and color sensor, optical amplifier and demux device is discussed. The design and the light source properties are correlated with the sensor output characteristics. Different readout techniques are used. When a low power monochromatic scanner readout the generated carriers the transducer recognizes a color pattern projected on it acting as a direct color and image sensor. Scan speeds up to 10(4) lines per second are achieved without degradation in the resolution. If the photocurrent generated by different monochromatic pulsed channels is readout directly, the information is demultiplexed. Results show that it is possible to decode the information from three simultaneous color channels without bit errors at bit rates per channel higher than 4000 bps. Finally, when triggered by light of appropriated wavelength, it can amplify or suppress the generated photocurrent working as an optical amplifier (C) 2009 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the past years wireless sensor networks (WSNs) have been coined as one of the most promising technologies for supporting a wide range of applications. However, outside the research community, few are the people who know what they are and what they can offer. Even fewer are the ones that have seen these networks used in real world applications. The main obstacle for the proliferation of these networks is energy, or the lack of it. Even though renewable energy sources are always present in the networks environment, designing devices that can efficiently scavenge that energy in order to sustain the operation of these networks is still an open challenge. Energy scavenging, along with energy efficiency and energy conservation, are the current available means to sustain the operation of these networks, and can all be framed within the broader concept of “Energetic Sustainability”. A comprehensive study of the several issues related to the energetic sustainability of WSNs is presented in this thesis, with a special focus in today’s applicable energy harvesting techniques and devices, and in the energy consumption of commercially available WSN hardware platforms. This work allows the understanding of the different energy concepts involving WSNs and the evaluation of the presented energy harvesting techniques for sustaining wireless sensor nodes. This survey is supported by a novel experimental analysis of the energy consumption of the most widespread commercially available WSN hardware platforms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação descreve o desenvolvimento e a caracterização de sensores ópticos com base em membranas de poli(cloreto de vinilo), PVC, para determinação de Norfloxacina em amostras do sector da aquacultura. Estes sensores basearam-se na reacção colorimétrica entre um metal imobilizado em PVC e a Norfloxacina. O metal foi escolhido com base em ensaios prévios de reacção colorimétrica entre a Norfloxacina e várias espécies metálicas, nomeadamente, Fe(III), Al(III), Pb(II), Aluminon, Mo(II), Mn(II), Ni(II), Cu(II), Co(II), Sn(II) e V(V). A reacção mais intensa foi obtida com o Fe(III). Neste sentido, numa primeira fase foram desenvolvidos sensores baseados em Fe(III). O efeito de alguns parâmetros experimentais na resposta desses sensores foi avaliado de modo univariado. Incluem-se aqui o efeito do pH, avaliado entre 2,00 e 6,00, e o da concentração de Fe(III), variada entre cerca de 1,00x10-5 M e 2,00x10-4 M. Os melhores valores foram obtidos a pH 3, para o qual se verificou um comportamento linear entre cerca de 1,00x10-5 M e 1,70x10-4 M de Fe(III). Utilizando as condições seleccionadas anteriormente, procedeu-se à caracterização do complexo sob ponto de vista químico. Os valores obtidos apontaram para a necessidade de um excesso de Fe(III) de, pelo menos, 10 vezes, no sentido de garantir a máxima extensão de complexação. O complexo referido apresentou, nestas condições, um comportamento linear ao longo do intervalo de concentrações de cerca de 7,00x10-5 M a 7,00x10-4 M em NOR. O complexo formado foi estável ao longo de 90 minutos. As condições óptimas para análise desse complexo numa superfície sólida foram obtidas após avaliação do efeito da quantidade de Fe(III) e do tipo e quantidade de solvente mediador (o-nitrofenil octil éter, di-n-octilftalato, dibutilftalato, bis(etilhexil)sebacato, bis(etilhexil)ftalato). O bis(etilhexil)sebacato foi o solvente mediador escolhido e a relação de quantidade entre o PVC e o solvente mediador foi igual a 1:2. O procedimento de preparação do sensor sólido e subsequente optimização foi aplicado a outras espécies metálicas, para além do Fe(III), tais como, Cu(II), Mn(II) e aluminon. A conjugação de todos estes metais permitiu desenvolver um array de sensores para despistagem de Norfloxacina em águas de aquacultura. Algumas membranas sensoras foram aplicadas com sucesso no controlo de Norfloxacina em amostras de águas ambientais dopadas. Os resultados obtidos com membranas de Fe(III) e Cu(II) foram exactos, tendo-se registado valores de concentração próximos dos reais. O método proposto permitiu, por isso, a despistagem rápida e eficaz da presença de um antibiótico em águas ambientais, permitindo ainda o seu doseamento a um baixo custo. Numa perspectiva de rotina, e tendo em vista a despistagem deste antibiótico, este método revelou-se mais rápido e mais barato do que os demais métodos descritos na literatura para este efeito.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In basaltic dykes the magnetic lineation K1 (maximum magnetic susceptibility axis) is generally taken to indicate the flow direction during solidification of the magma. This assumption was tested in Tertiary basaltic dykes from Greenland displaying independent evidence of subhorizontal flow. The digital processing of microphotographs from thin sections cut in (K1, K2) planes yields the preferred linear orientation of plagioclase, which apparently marks the magma flow lineation. In up to 60% of cases, the angular separation between K1 and the assumed flow direction is greater than 45degrees. This suggests that the uncorroborated use of magnetic lineations in dykes is risky. A simple geometrical method is proposed to infer the flow vector from AMS in dykes based solely on magnetic foliations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chapter in Book Proceedings with Peer Review First Iberian Conference, IbPRIA 2003, Puerto de Andratx, Mallorca, Spain, JUne 4-6, 2003. Proceedings

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho pretendeu desenvolver e testar um sensor óptico para detectar ciclamato de sódio, um adoçante artificial utilizado nas bebidas em geral. A primeira abordagem neste sentido baseou-se na preparação de um sensor óptico através da formação de complexos corados entre o ciclamato e várias espécies metálicas, nomeadamente Hg(II), Ba(II), Fe(II), Ag(II), Pb(II), Cd(II), Mn (II), Ni(II), Cu(II), Co(II), Sn(II) e Mg(II). Perante a ausência de resultados satisfatórios optou-se por explorar a acção do ciclamato de sódio na transferência/partilha de um corante entre duas fases líquidas imiscíveis. As fases líquidas utilizadas foram a água e o clorofórmio. Testaram-se várias famílias de corantes mas só uma classe se mostrou com as características apropriadas para o objectivo pretendido. Dentro dessa família de corantes, seleccionou-se aquele que, à partida, garantiu o melhor desempenho. O sensor foi testado em diferentes condições de pH e também na presença de potenciais interferentes de forma a estabelecer as melhores condições de utilização. O método mostrou-se bastante simples de executar, rápido na obtenção de resultados e com boas características para ser avaliado visualmente, mas sempre de acordo com os critérios de objectividade que um trabalho deste tipo requer. Além o disso permitiu ser calibrado de uma forma rápida e simples, características essenciais para a aplicação deste método na despistagem de ciclamato em análises de rotina. O método desenvolvido foi ainda aplicado à análise de vinho dopado com diferentes concentrações de ciclamato de sódio. Destes testes verificou-se a necessidade de optimização do método através da introdução de outras substâncias na fase não aquosa diminuindo a vulnerabilidade do sensor a outros interferentes. Como conclusão, o método correspondeu às expectativas, mostrando-se viável para aplicação à análise de vinhos, ainda com uma margem significativa de desenvolvimento no sentido de o tornar mais fiável e preciso.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new fluorescent sensor for nitric oxide (NO) is presented that is based on its reaction with a non fluorescent substance, reduced fluoresceinamine, producing the highly fluorescent fluoresceinamine. Using a portable homemade stabilized light source consisting of 450 nm LED and fiber optics to guide the light, the sensor responds linearly within seconds in the NO concentration range between about 10–750 µM with a limit of detection (LOD) of about 1 µM. The system generated precise intensity readings, with a relative standard deviation of less than 1%. The suitability of the sensor was assessed by monitoring the NO generated by either the nitrous acid decomposition reaction or from a NO-releasing compound. Using relatively high incubation times, the sensor also responds quantitatively to hydrogen peroxide and potassium superoxide, however, using transient signal measurements results in no interfering species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a biosensor based on a glassy carbon electrode (GCE) was used for the evaluation of the total antioxidant capacity (TAC) of flavours and flavoured waters. This biosensor was constructed by immobilising purine bases, guanine and adenine, on a GCE. Square wave voltammetry (SWV) was selected for the development of this methodology. Damage caused by the reactive oxygen species (ROS), superoxide radical (O2·−), generated by the xanthine/xanthine oxidase (XOD) system on the DNA-biosensor was evaluated. DNA-biosensor encountered with oxidative lesion when it was in contact with the O2·−. There was less oxidative damage when reactive antioxidants were added. The antioxidants used in this work were ascorbic acid, gallic acid, caffeic acid, coumaric acid and resveratrol. These antioxidants are capable of scavenging the superoxide radical and therefore protect the purine bases immobilized on the GCE surface. The results demonstrated that the DNA-based biosensor is suitable for the rapid assess of TAC in beverages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, a method for the electrochemical quantification of the total antioxidant capacity (TAC) in beverages was developed. The method is based on the oxidative damage to the purine bases, adenine or guanine, that are immobilized on a glassy carbon electrode (GCE) surface. The oxidative lesions on the DNA bases were promoted by the sulfate radical generated by the persulfate/iron(II) system. The presence of antioxidants on the reactive system promoted the protection of the DNA bases immobilized on the GCE by scavenging the sulfate radical. Square-wave voltammetry (SWV) was the electrochemical technique used to perform this study. The efficiencies of five antioxidants (ascorbic acid, gallic acid, caffeic acid, coumaric acid and resveratrol) in scavenging the sulfate radical and, therefore, their ability to protect the purine bases immobilized on the GCE were investigated. These results demonstrated that the purine-based biosensor is suitable for the rapid assessment of the TAC in flavors and flavored water.