958 resultados para Validation studies


Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: Accuracy studies of Patient Safety Indicators (PSIs) are critical but limited by the large samples required due to low occurrence of most events. We tested a sampling design based on test results (verification-biased sampling [VBS]) that minimizes the number of subjects to be verified. METHODS: We considered 3 real PSIs, whose rates were calculated using 3 years of discharge data from a university hospital and a hypothetical screen of very rare events. Sample size estimates, based on the expected sensitivity and precision, were compared across 4 study designs: random and VBS, with and without constraints on the size of the population to be screened. RESULTS: Over sensitivities ranging from 0.3 to 0.7 and PSI prevalence levels ranging from 0.02 to 0.2, the optimal VBS strategy makes it possible to reduce sample size by up to 60% in comparison with simple random sampling. For PSI prevalence levels below 1%, the minimal sample size required was still over 5000. CONCLUSIONS: Verification-biased sampling permits substantial savings in the required sample size for PSI validation studies. However, sample sizes still need to be very large for many of the rarer PSIs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To determine whether a mono-, bi- or tri-exponential model best fits the intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) signal of normal livers. MATERIALS AND METHODS: The pilot and validation studies were conducted in 38 and 36 patients with normal livers, respectively. The DWI sequence was performed using single-shot echoplanar imaging with 11 (pilot study) and 16 (validation study) b values. In each study, data from all patients were used to model the IVIM signal of normal liver. Diffusion coefficients (Di ± standard deviations) and their fractions (fi ± standard deviations) were determined from each model. The models were compared using the extra sum-of-squares test and information criteria. RESULTS: The tri-exponential model provided a better fit than both the bi- and mono-exponential models. The tri-exponential IVIM model determined three diffusion compartments: a slow (D1 = 1.35 ± 0.03 × 10(-3) mm(2)/s; f1 = 72.7 ± 0.9 %), a fast (D2 = 26.50 ± 2.49 × 10(-3) mm(2)/s; f2 = 13.7 ± 0.6 %) and a very fast (D3 = 404.00 ± 43.7 × 10(-3) mm(2)/s; f3 = 13.5 ± 0.8 %) diffusion compartment [results from the validation study]. The very fast compartment contributed to the IVIM signal only for b values ≤15 s/mm(2) CONCLUSION: The tri-exponential model provided the best fit for IVIM signal decay in the liver over the 0-800 s/mm(2) range. In IVIM analysis of normal liver, a third very fast (pseudo)diffusion component might be relevant. KEY POINTS: ? For normal liver, tri-exponential IVIM model might be superior to bi-exponential ? A very fast compartment (D = 404.00 ± 43.7 × 10 (-3)  mm (2) /s; f = 13.5 ± 0.8 %) is determined from the tri-exponential model ? The compartment contributes to the IVIM signal only for b ≤ 15 s/mm (2.)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fytoestrogeenit ovat kasvimateriaalista peräisin olevia yhdisteitä, joilla on ihmisen estrogeeni-hormonin kaltaista aktiivisuutta. Fytoestrogeenit voidaan jakaa kolmeen pääryhmään, joista yksi merkittävä ryhmä on lignaanit. Lignaaneilla on todettu olevan antioxidatiivisia, antiviraalisia ja antibakteriaalisia ominaisuuksia. Niillä on todettu olevan myös positiivisia vaikutuksia hormoniperäisten syöpien ehkäisyssä. Näiden ominaisuuksien vuoksi lignaaneja pyritään hyödyntämään esimerkiksi aktiivisina ainesosina funktionaalisissa elintarvikkeissa. Tässä työssä tutkittiin lignaanin, hydroksimatairesinolin (HMRlignanTM) kemiallisia ominaisuuksia ja soveltuvuutta eri ruoka-aineisiin. Työn tarkoituksena oli selvittää ruoka-aineisiin lisätyn hydroksimatairesinolin kemiallista pysyvyyttä erilaisissa säilytys- ja prosessointioloissa sekä tutkia lignaanin liukoisuutta erilaisiin liuottimiin. Hydroksimatairesinolin analysoimiseksi ruoka-aineista käytettiin korkean erotuskyvyn omaavaa nestekromatografista menetelmää. Menetelmä validoitiin ennen varsinaista analysointia ICH-ohjeiston mukaisesti. Validoinnissa tutkittiin kromatografiamenetelmän spesifisyys, lineaarisuus, tarkkuus, oikeellisuus sekä detektointi- ja määritysrajat tutkittavalle lignaanille. Käytetty menetelmä soveltui hyvin lignaanin analysoimiseen ruoka-aineista. Hydroksimatairesinolin vesiliukoisuuden todettiin olevan noin 1 mg/ml. Tutkimukset osoittivat hydroksimatairesinolin olevan stabiili alle 50ºC:en lämpötiloissa. Korkeammissa lämpötiloissa hydroksimatairesinoli oli stabiili jauhemuodossa lisättynä.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper contains a joint ESHG/ASHG position document with recommendations regarding responsible innovation in prenatal screening with non-invasive prenatal testing (NIPT). By virtue of its greater accuracy and safety with respect to prenatal screening for common autosomal aneuploidies, NIPT has the potential of helping the practice better achieve its aim of facilitating autonomous reproductive choices, provided that balanced pretest information and non-directive counseling are available as part of the screening offer. Depending on the health-care setting, different scenarios for NIPT-based screening for common autosomal aneuploidies are possible. The trade-offs involved in these scenarios should be assessed in light of the aim of screening, the balance of benefits and burdens for pregnant women and their partners and considerations of cost-effectiveness and justice. With improving screening technologies and decreasing costs of sequencing and analysis, it will become possible in the near future to significantly expand the scope of prenatal screening beyond common autosomal aneuploidies. Commercial providers have already begun expanding their tests to include sex-chromosomal abnormalities and microdeletions. However, multiple false positives may undermine the main achievement of NIPT in the context of prenatal screening: the significant reduction of the invasive testing rate. This document argues for a cautious expansion of the scope of prenatal screening to serious congenital and childhood disorders, only following sound validation studies and a comprehensive evaluation of all relevant aspects. A further core message of this document is that in countries where prenatal screening is offered as a public health programme, governments and public health authorities should adopt an active role to ensure the responsible innovation of prenatal screening on the basis of ethical principles. Crucial elements are the quality of the screening process as a whole (including non-laboratory aspects such as information and counseling), education of professionals, systematic evaluation of all aspects of prenatal screening, development of better evaluation tools in the light of the aim of the practice, accountability to all stakeholders including children born from screened pregnancies and persons living with the conditions targeted in prenatal screening and promotion of equity of access.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Simvastatin is an oral anti-hyperlipidemic that has been widely used to reduce the cardiovascular disease risk. There isn't any pharmacopoeic method to assay this drug in capsules. It was proposed and validated a method for determining the content of simvastatin in capsules by UV/visible spectrophotometry (l = 237 nm), a more affordable method for the compounding pharmacy. The method was validated for linearity, specificity, range, accuracy, precision, performance, robustness, and limits of detection and quantification.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Radiostereometric analysis (RSA) is a highly accurate method for the measurement of in vivo micromotion of orthopaedic implants. Validation of the RSA method is a prerequisite for performing clinical RSA studies. Only a limited number of studies have utilised the RSA method in the evaluation of migration and inducible micromotion during fracture healing. Volar plate fixation of distal radial fractures has increased in popularity. There is still very little prospective randomised evidence supporting the use of these implants over other treatments. The aim of this study was to investigate the precision, accuracy, and feasibility of using RSA in the evaluation of healing in distal radius fractures treated with a volar fixed-angle plate. A physical phantom model was used to validate the RSA method for simple distal radius fractures. A computer simulation model was then used to validate the RSA method for more complex interfragmentary motion in intra-articular fractures. A separate pre-clinical investigation was performed in order to evaluate the possibility of using novel resorbable markers for RSA. Based on the validation studies, a prospective RSA cohort study of fifteen patients with plated AO type-C distal radius fractures with a 1-year follow-up was performed. RSA was shown to be highly accurate and precise in the measurement of fracture micromotion using both physical and computer simulated models of distal radius fractures. Resorbable RSA markers demonstrated potential for use in RSA. The RSA method was found to have a high clinical precision. The fractures underwent significant translational and rotational migration during the first two weeks after surgery, but not thereafter. Maximal grip caused significant translational and rotational interfragmentary micromotion. This inducible micromotion was detectable up to eighteen weeks, even after the achievement of radiographic union. The application of RSA in the measurement of fracture fragment migration and inducible interfragmentary micromotion in AO type-C distal radius fractures is feasible but technically demanding. RSA may be a unique tool in defining the progress of fracture union.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Apresentar a adaptação transcultural para o português da Escala de Atitudes em Relação ao Ganho de Peso na Gestação.MÉTODOS: Essa escala, que contém afirmações que expressavam diferentes atitudes de gestantes em relação ao seu próprio ganho de peso, foi desenvolvida para determinar se as atitudes em relação ao corpo afetariam o ganho de peso durante a gestação. Os procedimentos foram: tradução, retrotradução, avaliação da compreensão, elaboração de versão final, aplicação da escala em 180 gestantes (média 29,6 anos e idade gestacional 25,7 semanas) e análise psicométrica.RESULTADOS: Constatou-se equivalência satisfatória entre as versões inglês-português e boa consistência interna (Alpha de Cronbach 0,7). A análise fatorial exploratória sugeriu quatro subescalas com variância total explicada de 51,4%.CONCLUSÃO: A escala se demonstrou válida e pode ser utilizada em estudos com gestantes no Brasil para avaliação de atitudes em relação ao ganho de peso e detecção e prevenção de comportamentos disfuncionais durante a gestação.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this work is to describe the design and the implementation of an experiment to study the dynamics and the active control of a slewing multi-link flexible structure. The experimental apparatus was designed to be representative of a flexible space structure such as a satellite with multiple flexible appendages. In this study we describe the design procedures, the analog and digital instrumentation, the analytical modeling together with model validation studies carried out through experimental modal testing and parametric system identification studies in the frequency domain. Preliminary results of a simple positional control where the sensor and the actuator are positioned physically at the same point is also described.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper analyzes the profile of the Brazilian output in the field of multiple sclerosis from 1981 to 2004. The search was conducted through the MEDLINE and LILACS databases, selecting papers in which the term "multiple sclerosis" was defined as the main topic and "Brazil" or "Brasil" as others. The data were analyzed regarding the themes, the state in Brazil and institution where the papers were produced, the journals where the papers were published, journal's impact factor, and language. The search disclosed 141 documents (91 from MEDLINE and LILACS, and 50 from LILACS only) published in 44 different journals (23 of them MEDLINE-indexed). A total of 111 documents were produced by 17 public universities, 29 by 3 private medical schools and 1 by a non-governmental organization. There were 65 original contributions, 37 case reports, 20 reviews, 6 PhD dissertations, 5 guidelines, 2 validation studies, 2 clinical trials, 2 chapters in textbooks, 1 Master of Science thesis, and 1 patient education handout. The journal impact factor ranged from 0.0217 to 6.039 (median 3.03). Of 91 papers from MEDLINE, 65 were published by Arquivos de Neuro-Psiquiatria. More than 90% of the papers were written in Portuguese. São Paulo was the most productive state in the country, followed by Rio de Janeiro, Minas Gerais and Paraná. Eighty-two percent of the Brazilian output came from the Southeastern region.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Le vieillissement démographique augmente rapidement la représentation des personnes âgées de plus de 50 ans parmi les utilisateurs d’aides à la mobilité motorisées (AMMs), telles que le fauteuil roulant motorisé et le quadriporteur. Le but général de la thèse est de rendre compte d’une démarche d’analyse des effets des AMMs au cours des premiers 18 mois d’utilisation chez les adultes d’âge moyen et les aînés. Notre question de recherche concerne la nature et l'importance des effets sur le fonctionnement, la pertinence sociale et le bien-être subjectif, ainsi que les liens entre les divers facteurs impliqués dans leur impact optimal. La thèse s’articule en trois volets, synthétique, méthodologique et analytique, dont les principaux résultats sont présentés dans quatre articles scientifiques. Le volet synthétique comprend une recension systématique qui révèle la représentation marginale des personnes âgées de plus de 50 ans dans les publications scientifiques sur les effets des AMMs et le faible niveau de preuve dans ce champ d’études. Les travaux liés à ce volet proposent également un cadre d’analyse reliant l’intention d’utiliser l’AMM, les habitudes de déplacements, les dimensions d’effets des AMMs sur le fonctionnement, la pertinence sociale et le bien-être subjectif, ainsi que quatre catégories de cofacteurs associés à l’utilisation (personne, aide technique, intervention, environnement). Le volet méthodologique assemble un dispositif de mesure comprenant 5 questionnaires et 18 indicateurs arrimés au cadre d’analyse et démontre l’applicabilité de l’ensemble des questionnaires pour une administration téléphonique. La validation transculturelle de deux questionnaires implique deux études réalisées auprès d’utilisateurs d’AMMs âgés de 50 à 84 ans (n=45). Ces travaux confirment la fidélité test-retest et l’équivalence des questionnaires traduits avec la version d’origine. Finalement, le volet analytique se concentre sur l’étude des habitudes de déplacements chez 3 cohortes (n=116) de personnes âgées de 50 à 89 ans, recrutées en fonction du stade d’utilisation de l’AMM. Les résultats suggèrent une amélioration de l’aire de mobilité après l’utilisation initiale ou long terme de l’AMM en comparaison avec une cohorte en attente de l’AMM, ainsi qu’une augmentation significative de la fréquence des déplacements autour du domicile et dans le voisinage. Trois facteurs associés à une aire de mobilité optimale, à savoir le genre, la nature des objectifs de participation de l’utilisateur et le type d’appareil utilisé, sont identifiés par des analyses de régression linéaires contrôlant pour l’âge. La thèse soutient l’importance de tenir compte de l’environnement et d’une combinaison de facteurs reliés à la personne et à l’aide technique pour saisir les effets des AMMs au cours des premiers mois d’utilisation. Ces résultats ouvrent la voie au suivi systématique des utilisateurs d’AMMs par les professionels de réadaptation, puisqu’ils confirment l’utilité du dispositif pour en mesurer les effets et ciblent les déterminants de la mobilité des utilisateurs d’AMMs âgés de plus de 50 ans.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La réadaptation pulmonaire est une intervention dont l’efficacité est largement reconnue. Cette efficacité a été établie grâce à l’utilisation d’instruments de mesure d’impact global. Les patients bénéficiant des programmes de réadaptation pulmonaire possèdent des caractéristiques variées et souffrent généralement de maladie pulmonaire obstructive chronique à différents degrés. En fonction de leurs différents besoins, les patients répondent de façon variable aux composantes d’un programme de réadaptation pulmonaire. Il est recommandé d’individualiser les programmes en fonction des besoins des patients afin d’en optimiser les effets. À cette fin, l’évaluation des besoins de réadaptation des patients est nécessaire. Comme il n’existe actuellement aucun instrument standardisé pour procéder à cette évaluation, nous avons entrepris d’en développer un à l’aide de méthodes qualitatives et quantitatives de recherche. Un modèle conceptuel d’évaluation des besoins de réadaptation des patients a été élaboré suite aux résultats tirés de groupes de discussion, de la consultation de dossiers médicaux et d’une recension des écrits. À partir de ce modèle, des items devant être sélectionnés de façon individualisée parmi cinq domaines (reconnaissance des besoins, connaissance, motivation, attentes et buts) ont été pré-testés. Les tendances générales concernant la validité des items contenus dans le prototype d’instrument ont été vérifiées lors d’une étude pilote auprès de 50 répondants en réadaptation. Les pistes d’investigation dégagées dans ce mémoire serviront aux études de validation plus approfondies dont devrait faire l’objet ce prototype d’instrument dans le futur.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectif : Étudier le risque d’hémorragies intracrâniennes et d’infarctus du myocarde chez les patients vivant avec le VIH. Méthode : J’ai réalisé deux études de cohorte au sein de la banque de données de la Régie de l’assurance maladie du Québec. J’ai défini la cohorte des patients VIH-positifs, y ai étudié l’incidence d’hémorragies intracrâniennes et d’infarctus du myocarde, et l’ai comparée à une cohorte VIH-négative de même âge et de même sexe. J’ai étudié l’association entre ces évènements et l’exposition aux antirétroviraux au moyen d’études cas-témoin nichées dans la cohorte des patients VIH-positifs. Résultats : Le VIH est associé à un risque plus élevé d’hémorragies intracrâniennes, particulièrement au stade SIDA. Les patients VIH-positif sont également plus à risque de subir un infarctus du myocarde, et certains antirétroviraux sont associés à un risque plus grand. Conclusion : Les banques de données médico-administratives représentent un moyen valable d’étudier les comorbidités non-infectieuses chez les patients atteints du VIH.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Le diabète de type 1 (DT1) est une maladie complexe qui requiert une implication importante des patients pour contrôler leur glycémie et ainsi prévenir les complications et comorbidités. L’activité physique (AP) régulière et une attention constante pour les glucides ingérés sont des adjuvants essentiels au traitement insulinique. Nous avons démontré que le questionnaire BAPAD-1, spécifiquement développé pour des adultes atteints de DT1, est un outil valide (validité prédictive, fiabilité interne et reproductibilité) pour définir des barrières associées à l’AP. Bien que le niveau de barrières envers l’AP soit faible, la crainte de l’hypoglycémie est la barrière la plus importante chez cette population. L’adoption d’un mode de vie actif est associée à un profil corporel favorable. Les adultes, avec un DT1 et non diabétique, qui maintiennent un bon niveau d’AP, soit un ratio entre la dépense énergétique totale et celle au repos ≥ 1.7, ont une masse grasse, un indice de masse corporelle et un tour de taille significativement inférieurs à ceux d’adultes moins actifs. Le niveau d’AP peut être estimé au moyen d’un moniteur d’AP comme le SenseWear Armband™. Afin de compléter les études de validation de cet outil, nous avons évalué et démontré la reproductibilité des mesures. Toutefois, la dépense énergétique est sous-estimée durant les 10 premières minutes d’une AP d’intensité modérée sur ergocycle. L’utilisation de cet appareil est donc justifiée pour une évaluation de la dépense énergétique sur de longues périodes. Le calcul des glucides est une méthode largement utilisée pour évaluer la quantité d’insuline à injecter lors des repas. Nous avons évalué dans un contexte de vie courante, sans révision de la technique, la précision des patients pour ce calcul. L’erreur moyenne est de 15,4 ± 7,8 g par repas, soit 20,9 ± 9,7 % du contenu glucidique. L’erreur moyenne est positivement associée à de plus grandes fluctuations glycémiques mesurées via un lecteur de glucose en continu. Une révision régulière du calcul des glucides est probablement nécessaire pour permettre un meilleur contrôle glycémique. Nous avons développé et testé lors d’un essai clinique randomisé contrôlé un programme de promotion de l’AP (PEP-1). Ce programme de 12 semaines inclut une séance hebdomadaire en groupe ayant pour but d’initier l’AP, d’établir des objectifs et d’outiller les adultes atteints de DT1 quant à la gestion de la glycémie à l’AP. Bien que n’ayant pas permis d’augmenter la dépense énergétique, le programme a permis un maintien du niveau d’AP et une amélioration de la condition cardio-respiratoire et de la pression artérielle. À la fin du programme, une plus grande proportion de patients connaissait la pharmacocinétique de l’insuline et une plus grande variété de méthodes pour contrer l’hypoglycémie associée à l’AP était utilisée. En conclusion, le diabète de type 1 engendre des défis quotidiens particuliers. D’une part, le calcul des glucides est une tâche complexe et son imprécision est associée aux fluctuations glycémiques quotidiennes. D’autre part, l’adoption d’un mode de vie actif, qui est associée à un meilleur profil de composition corporelle, est limitée par la crainte des hypoglycémies. Le programme PEP-1 offre un support pour intégrer l’AP dans les habitudes de vie des adultes avec un DT1 et ainsi améliorer certains facteurs de risque cardio-vasculaire.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Le foie est un organe vital ayant une capacité de régénération exceptionnelle et un rôle crucial dans le fonctionnement de l’organisme. L’évaluation du volume du foie est un outil important pouvant être utilisé comme marqueur biologique de sévérité de maladies hépatiques. La volumétrie du foie est indiquée avant les hépatectomies majeures, l’embolisation de la veine porte et la transplantation. La méthode la plus répandue sur la base d'examens de tomodensitométrie (TDM) et d'imagerie par résonance magnétique (IRM) consiste à délimiter le contour du foie sur plusieurs coupes consécutives, un processus appelé la «segmentation». Nous présentons la conception et la stratégie de validation pour une méthode de segmentation semi-automatisée développée à notre institution. Notre méthode représente une approche basée sur un modèle utilisant l’interpolation variationnelle de forme ainsi que l’optimisation de maillages de Laplace. La méthode a été conçue afin d’être compatible avec la TDM ainsi que l' IRM. Nous avons évalué la répétabilité, la fiabilité ainsi que l’efficacité de notre méthode semi-automatisée de segmentation avec deux études transversales conçues rétrospectivement. Les résultats de nos études de validation suggèrent que la méthode de segmentation confère une fiabilité et répétabilité comparables à la segmentation manuelle. De plus, cette méthode diminue de façon significative le temps d’interaction, la rendant ainsi adaptée à la pratique clinique courante. D’autres études pourraient incorporer la volumétrie afin de déterminer des marqueurs biologiques de maladie hépatique basés sur le volume tels que la présence de stéatose, de fer, ou encore la mesure de fibrose par unité de volume.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objetivo: El cuestionario Barriers to Being Active Quiz (BBAQ), indaga las barreras para ser físicamente activo. El cuestionario fue traducido al español por el mismo equipo que desarrolló la versión inglésa original, pero carece de estudios de validez en la versión española. El objetivo de esta investigación fue evaluar las propiedades psicométricas del BBAQ (en la versión completa de 21 ítems), centrándose en la fiabilidad y validez. Material y métodos: Un total de 2.634 (1.462 mujeres y 1.172 varones; 18-30 años de edad) estudiantes universitarios completaron el cuestionario BBAQ-21. El alfa de Crombach se estimó como indicador de consistencia interna. El coeficiente de correlación intra-clase (CCI) y el grado de acuerdo se calcularon para evaluar la estabilidad temporal con un periodo de 7 días entre ambas administraciones como estimadores de la reproducibilidad. Se aplicó un análisis factorial exploratorio (AFE) y confirmatorio (AFC) para analizar la validez del BBAQ-21 ítems. Resultados: El BBAQ-21 mostró valores de un alfa de Cronbach entre 0,812 y 0,844 y un CCI entre el 0,46 y 0,87. El porcentaje de acuerdo por todos los conceptos individuales varió de 45 a 80%. El AFE determinó cuatro factores que explicaron el 52,90% de la varianza y el AFC mostró moderadas cargas factoriales. Conclusiones: Los resultados obtenidos en este cuestionario avalan la utilización de este instrumento con este tipo de muestra, desde el punto de vista de la fiabilidad y validez. El BBAQ-21 está disponible para evaluar las barreras para la actividad física en América Latina.