865 resultados para Validation of analytical methods
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The existence of organic and inorganic contaminants present in both fossil and biomass fuels and the fact that they can provide undesirable effects (environmental problems, corrosion processes, lead to storage instability, and others) implies a rigorous quality control of these fuels, although these contaminants make up a small part of the final fuel composition. Considering the rising importance of fuel ethanol in the worldwide panorama, this review aims at reporting the use of successful alternative analytical methods in the monitoring of organic and inorganic contaminants at trace levels, used to determine and to quantify these substances in fuel ethanol and also presenting all official norms for quality control of fuel ethanol employed by ABNT (Brazilian Association of Technical Norms), ASTM (American Society for Testing and Materials), and ECS (European Committee for Standardization).
Resumo:
Fluconazole, -(2.4-diflurofenil)--(1H-triazol-1-methyl)-1H-1,2,4-triazol-1-ethanol, is an antifungal of triazoles class. It shows activity against species of Candida sp., and it is indicated in cases of oropharyngeal candidiasis, esophageal, vaginal, and deep infection. Fluconazole is a selective inhibitor of ergosterol, a steroid exclusive of the cell membrane of fungal cells. Fluconazole is highly absorbed by the gastrointestinal tract, and it spreads easily by body fluids. The main adverse reactions related to the use of fluconazole are nausea, vomiting, headache, rash, abdominal pain, diarrhea, and alopecia in patients undergoing prolonged treatment with a dose of 400 mg/day. In the form of raw material, pharmaceutical formulations, or biological material, fluconazole can be determined by methods such as titration, spectrophotometry, and thin-layer, gas, and liquid chromatography. This article discusses the pharmacological and physical-chemical properties of fluconazole and also the methods of analysis applied to the determination of the drug.
Resumo:
Lubricating oils are crucial in the operation of automotive engines because they both reduce friction between moving parts and protect against corrosion. However, the performance of lubricant oil may be affected by contaminants, such as gasoline, diesel, ethanol, water and ethylene glycol. Although there are many standard methods and studies related to the quantification of contaminants in lubricant oil, such as gasoline and diesel oil, to the best of our knowledge, no methods have been reported for the quantification of ethanol in used Otto cycle engine lubrication oils. Therefore, this work aimed at the development and validation of a routine method based on partial least-squares multivariate analysis combined with attenuated total reflectance in the mid-infrared region to quantify ethanol content in used lubrication oil. The method was validated based on its figures of merit (using the net analyte signal) as follows: limit of detection (0.049%), limit of quantification (0.16%), accuracy (root mean square error of prediction=0.089% w/w), repeatability (0.05% w/w), fit (R 2 =0.9997), mean selectivity (0.047), sensitivity (0.011), inverse analytical sensitivity (0.016% w/w-1) and signal-to-noise ratio (max: 812.4 and min: 200.9). The results show that the proposed method can be routinely implemented for the quality control of lubricant oils. © 2013 Elsevier B.V. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Orbifloxacin is a third generation of fluoroquinolone that exhibits increased antibacterial activity against the Enterobacteriaceae, gram-negative and gram-positive bacteria, anaerobes, and mycobacteria. This drug was synthesized in 1987 and developed as a veterinary chemotherapeutic to use for livestock and domestic pets. Orbifloxacin is labeled for the treatment of skin, soft tissue, and urinary tract infections in dogs, and skin and soft tissue infections in cats, but in some countries, orbifloxacin has been given for the treatment of gastrointestinal and respiratory infections in cattle and swine and other animals. The in vitro activity and clinical efficacy of orbifloxacin against naturally occurring bacterial infections of the skin, ear, soft tissue, udder, and gastrointestinal and respiratory systems in different animals have been evaluated and good responses have been found. The minimum inhibitory concentration of orbifloxacin has been determined in various different pathogens and the results found in the literature are shown in this work. The pharmacokinetics of orbifloxacin has been evaluated by different routes of administration in goats, horses, pigs, rabbits, dogs, cats, camels, cattle, sheep, and fish. Orbifloxacin exhibits excellent pharmacokinetic parameters that suggest that this drug may have good clinical effects on various bacterial infections in these species. All methods described in the scientific literature for determination of orbifloxacin in different matrices were collected and discussed. © 2013 Copyright Taylor and Francis Group, LLC.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
To validate a model for investigating the effects of analgesic drugs on mechanical, thermal and electrical stimulation testing. To investigate repeatability, sensitivity and specificity of nociceptive tests. Randomised experiment with 2 observers in 2 phases. Mechanical (M), thermal (TL) and electrical (E) stimuli were applied to the dorsal metacarpus (M-left and TL-right) and coronary band of the left thoracic limb (E) and a thoracic thermal stimulus (TT) was applied caudal to the withers in 8 horses (405 ± 43 kg). Stimuli intensities were increased until a clear avoidance response was detected without exceeding 20 N (M), 60°C (TL and TT) and 15 V (E). For each set of tests, 3 real stimuli and one sham stimulus were applied (32 per animal) using a blinded, randomised, crossover design repeated after 6 months. A distribution frequency and, for each stimulus, Chi-square and McNemar tests compared both the proportion of positive responses detected by 2 observers and the 2 study phases. The κ coefficients estimated interobserver agreement in determining endpoints. Sensitivity (384 tests) and specificity (128 tests) were evaluated for each nociceptive stimulus to assess the evaluators' accuracy in detecting real and sham stimuli. Nociceptive thresholds were 3.1 ± 2 N (M), 8.1 ± 3.8 V (E), 51.4 ± 5.5°C (TL) and 55.2 ± 5.3°C (TT). The level of agreement after all tests, M, E, TL and TT, was 90, 100, 84, 98 and 75%, respectively. Sensitivity was 89, 100, 89, 98 and 70% and specificity 92, 97, 88, 91 and 94%, respectively. The high interobserver agreement, sensitivity and specificity suggest that M, E and TL tests are valid for pain studies in horses and are suitable tools for investigating antinociceptive effects of analgesics in horses.
A critical review of the properties of fusidic acid and the analytical methods for its determination
Resumo:
Fusidic acid, an antibiotic produced from the Fusidium coccineum fungus, belongs to the class of steroids, but has no corticosteroid effects. It is indicated for the treatment of infections caused by methicillin-resistant Staphylococcus aureus strains. The aim of this study was to search for the properties of fusidic acid published so far in the literature, as well as the methods developed for its determination in biological samples and pharmaceutical formulations. From the findings, we can conclude that fusidic acid has been used for decades and is indicated for the treatment of serious infections caused by Gram-positive microorganisms to this day. Furthermore, it is a hypoallergenic agent, has low toxicity, shows low resistance, and has no cross-resistance with other clinically used antibiotics. The analytical method of high-performance liquid chromatography has been widely used, since it can reduce the cost and time of analysis, making it more viable for routine quality control in the pharmaceutical industry.