958 resultados para VOLUMES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flotation or cell recovery in foams (proportion of the total cells in the medium transferred to the foam) and flotation efficiency (proportion of the cells transferred from an initial volume of medium equal to the residual volume after flotation) are functions of time, aeration rate, initial volume of medium, and initial concentration of cells. Cell recovery reached constant values (around 96.4 +/- 6.3%) and flotation efficiency decreased (owing to increases in the liquid content of the foam), with increases in air how rate (above 6-7 ml air s(-1)) and volumes of medium (above 11 ml) added to the column. Increases in concentration of cells in the medium led to increases in the concentration of cells in the foam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Intravenous injection of contrast material is routinely performed in order to differentiate nonaerated lung parenchyma from pleural effusion in critically ill patients undergoing thoracic computed tomography (CT). The aim of the present study was to evaluate the effects of contrast material on CT measurement of lung volumes in 14 patients with acute lung injury. Method. A spiral thoracic CT scan, consisting of contiguous axial sections of 10 mm thickness, was performed from the apex to the diaphragm at end-expiration both before and 30 s (group 1; n=7) or 15 min (group 2; n=7) after injection of 80 ml contrast material. Volumes of gas and tissue, and volumic distribution of CT attenuations were measured before and after injection using specially designed software (Lungview®; Institut National des Télécommunications, Evry, France). The maximal artifactual increase in lung tissue resulting from a hypothetical leakage within the lung of the 80 ml contrast material was calculated. Results. Injection of contrast material significantly increased the apparent volume of lung tissue by 83 ± 57 ml in group 1 and 102 ± 80 ml in group 2, whereas the corresponding maximal artifactual increases in lung tissue were 42 ± 52 ml and 31 ± 18 ml. Conclusion. Because systematic injection of contrast material increases the amount of extravascular lung water in patients with acute lung injury, it seems prudent to avoid this procedure in critically ill patients undergoing a thoracic CT scan and to reserve its use for specific indications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large volume parenteral solutions (LVPS) are widely used as vehicles for intravenous administration of drugs and polyvinyl chloride (PVC) flexible bags are, nowadays, the plastic containers most commonly used to pack and drip-feed LVPS. An advantage of using bags is that they collapse flat and thus reduce the risk of airborne contamination and embolism caused by air in the bloodstream. They are mainly used in hospitals. This review deals with some important aspects of the PVC packaging containing the plasticizer DEHP, generally used to pack LVPS. The interaction between drug and package is discussed, with an emphasis on the migration of DEHP from the PVC bag to LVPS containing the immunosuppressant cyclosporin, and toxicological aspects are considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this research was to evaluate two tips of spraying nozzles (hollow cone nozzle and two flat fan nozzle annexed to a nozzle body DUO) and three spray volumes (100, 150 and 200 dm3 ha-1), whose application was for the control of the Asian soybean rust. An area of 288 m 2 was used, with a randomized blocks design in a factorial 2×3 with 4 repetitions, total of 24 experimental parcels of 12 m2. For the spraying with hydraulical nozzles a costal spray of constant pressure kept by C02 compressed with bar of 2 m was used. The analysis of the covering percentage was carried through by means of the use of hidro-sensible paper, that was placed in three position of the plant what it represents, in height, the third superior, average and inferior of the canopy. For both the third no interaction between the evaluated factors, was found and meither difference statistics between the spraying tips and the volumes. In absolute values the twin flat fan nozzle DUO presented minimum difference of covering in relation to the hollow cone nozzle, and for the spray volume of 200 dm3 ha -1 presented greater covering percentage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid, robust and economical method for the analysis of persistent halogenated organic compounds in small volumes of human serum and umbilical cord blood is described. The pollutants studied cover a broad range of molecules of contemporary epidemiological and legislative concern, including polychlorobiphenyls (PCBs), polychlorobenzenes (CBs), hexachlorocyclohexanes (HCHs), DDTs, polychlorostyrenes (PCSs) and polybromodiphenyl ethers (PBDEs). Extraction and clean-up with n-hexane and concentrated sulphuric acid was followed with analysis by gas chromatography coupled to electron capture (GC-ECD) and GC coupled to negative ion chemical ionisation mass spectrometry (GC-NICI-MS). The advantages of this method rest in the broad range of analytes and its simplicity and robustness, while the use of concentrated sulphuric acid extraction/clean-up destroys viruses that may be present in the samples. Small volumes of reference serum between 50 and 1000 μL were extracted and the limits of detection/quantification and repeatability were determined. Recoveries of spiked compounds for the extraction of small volumes (≥300 μL) of the spiked reference serum were between 90% and 120%. The coefficients of variation of repeatability ranged from 0.1-14%, depending on the compound. Samples of 4-year-old serum and umbilical cord blood (n = 73 and 40, respectively) from a population inhabiting a village near a chloro-alkali plant were screened for the above-mentioned halogenated pollutants using this method and the results are briefly described. © 2010 Springer-Verlag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study aimed to evaluate the performance of air assistance in spray booms using different types of nozzles and spray volumes. We took into account spray deposits, fall armyworm control and crop corn performance in a narrow row cropping system. The experiment was carried out at the experimental area of Sao Paulo State University, Botucatu/SP, Brazil, during the 2008/2009 agricultural season, in randomized blocks with a factorial scheme (2×2+1) and four replications. Two spray nozzles (flat fan nozzle and hollow cone nozzle) were tested, combined with two air assistance levels in the spray boom (with and without air assistance) and a treatment control. In the experimental spraying, Spinosad insecticide was sprayed in amounts of 48 g active substance (a.s.)/ha. The air assistance in the spray boom increased the spray deposits in the V 4 growth stage of the corn plants. Moreover, the application of this technology showed higher efficiency on fall armyworm control, reaching a 100% level 15 days after spraying, in the V 10 growth stage of the plants. The hollow cone nozzle increased the spray deposit level on the corn plants compared with the flat fan nozzle, at growth stage V 4. However, the flat fan nozzle, combined with air assistance technology, was more effective for controlling fall armyworm in the same growth stage (V 4), although the hollow cone nozzle increased the deposit levels on the plants. All the technologies tested in the study promoted a reduction of plant damage from fall armyworm attack. Corn productivity is directly related to the control efficiency of fall armyworm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study, different freezing systems (Styrofoam box and Mini Digitcool ZH 400) and storage volumes (0.5- and 0.25-mL straws) were compared with regard to sperm kinetics and plasma membrane integrity of frozen and thawed semen. For that, three ejaculates from four animals were frozen in Styrofoam box and Mini Digitcool ZH 400 machine. The 0.5-mL straws were thawed at 46°C for 20 seconds, and the 0.25-mL straws were thawed at 46°C for 12 seconds. Statistical analysis was performed using program R of descriptive analysis box plot, followed by analysis of variance using PROC MIXED of SAS 9.1 package. Variances of 5% were considered as different. There was no interaction between the straw sizes and volumes; however, statistical differences were observed between the semen storage volumes. The 0.5-mL straws had higher total motility (%), progressive motility (%), average path velocity (μm/s), straight-line velocity (μm/s), curvilinear velocity (μm/s), and rapid sperm percentage (%) than the 0.25-mL straws. However, plasma membrane integrity analysis did not differ between the two straws. Thus, it is possible to conclude that equine sperm cryopreserved in 0.5-mL straws has better sperm kinetics than when stored in 0.25-mL straws. Additionally, it is possible to conclude that automated systems that enable faster freezing rates result in a seminal quality that is similar to the one obtained by the conventional system using Styrofoam boxes. © 2013 Elsevier Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)