977 resultados para Uniformization of Compact Complex Manifolds with Ample Canonical Bundle


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have used the 2dF spectrograph on the Anglo-Australian Telescope to obtain a complete spectroscopic sample of all objects in the magnitude range, 16.5 < bj < 19.8, regardless of morphology, in an area centred on the Fornax Cluster of galaxies. Among the unresolved targets are five objects which are members of the Fornax Cluster. They are extremely compact stellar systems with scale lengths less than 40 parsecs. These ultra-compact dwarfs are unlike any known type of stellar system, being more compact and significantly less luminous than other compact dwarf galaxies, yet much brighter than any globular cluster.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A variety of nanostructures are being investigated as functional drug carriers for treatment of a wide range of diseases, most notably cardiovascular defects, autoimmune diseases, and cancer. The aim of this present contribution is to evaluate potentially applicable nanomaterials in the diagnosis and treatment of cancer due to their photophysical and photobiological properties and complexation behavior. The delivery systems consisted of chloro-aluminum phthalocyanine associated with beta-cyclodextrin and hydroxypropyl-beta-cyclodextrin. The preparation of the complex and its stoichiometry in an ethanol/buffer (3:1) solution were studied by spectroscopic techniques, which were defined as 1:2. The inclusion complex in the nanometer scale was observed on the basis of changes to the spectroscopic properties. The singlet oxygen production and complex photophysical parameters were determined by measuring luminescence at 1270 nm and by steady state and time resolved spectroscopic, respectively. The preparation of the complex was tested and analyzed with regard to cellular damage by visible light activation. The inclusion complex showed a higher singlet oxygen quantum yield compared with other systems and other photoactive dyes. There was also a reduction in the fluorescence quantum yield compared with the results obtained for zinc phthalocyanine in organic medium. The results reported clearly that the inclusion complex chloro-aluminum phthalocyanine/cyclodextrin showed some changes in its spectroscopy properties leading to better biodistribution and biocompatibility with a potential application in photodynamic therapy, especially in the case of neoplasy. Additionally, it also has non-oncological applications as a drug delivery system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The monobloc frontofacial osteotomy provides aesthetic and functional improvement in the treatment of various craniofacial deformities. This procedure, through highly complex, has had some significant associated complication, such as cerebrospinal fluid leakage, hematoma, infection, and bone resorption. Distraction has been successfully used to gradually elongate bone and soft tissue. This method seems to provide improved results over conventional surgery, with less morbidity. We present a case of a patient with Apert syndrome who underwent monobloc advancement using the Rigid External Device (RED) device and who developed a transient bilateral amaurosis on the fourth postoperative day before distraction. A second procedure was performed to push back the frontal bandeau, maintaining the device in position. The blindness was resolved with this procedure as well as treatment with systemic steroids. The distraction was started thereafter, and the desired improvement was acquired. To our knowledge, this is the first case of transient bilateral amaurosis in a patient undergoing monobloc distraction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Although digital and videotaped images are known to be comparable for the evaluation of left ventricular function, their relative accuracy for assessment of more complex anatomy is unclear. We sought to compare reading time, storage costs, and concordance of video and digital interpretations across multiple observers and sites. Methods. One hundred one patients with valvular (90 mitral, 48 aortic, 80 tricuspid) disease were selected prospectively, and studies were stored according to video and standardized digital protocols. The same reviewer interpreted video and digital images independently and at different times with the use of a standard report form to evaluate 40 items (eg, severity of stenosis or regurgitation, leaflet thickening, and calcification) as normal or mildly, moderately, or severely abnormal Concordance between modalities was expressed at kappa Major discordance (difference of >1 level of severity) was ascribed to the modality that gave the lesser severity. CD-ROM was used to store digital data (20:1 lossy compression), and super-VHS video-tape was used to store video data The reading time and storage costs for each modality were compared Results. Measured parameters were highly concordant (ejection fraction was 52% +/- 13% by both). Major discordance was rare, and lesser values were reported with digital rather than video interpretation in the categories of aortic and mitral valve thicken ing (1% to 2%) and severity of mitral regurgitation (2%). Digital reading time was 6.8 +/- 2.4 minutes, 38% shorter than with video (11.0 +/- 3.0, range 8 to 22 minutes, P < .001). Compressed digital studies had an average size of 60 <plus/minus> 14 megabytes (range 26 to 96 megabytes). Storage cost for video was A$0.62 per patient (18 studies per tape, total cost A$11.20), compared with A$0.31 per patient for digital storage (8 studies per CD-ROM, total cost A$2.50). Conclusion. Digital and video interpretation were highly concordant; in the few cases of major discordance, the digital scores were lower, perhaps reflecting undersampling. Use of additional views and longer clips may be indicated to minimize discordance with video in patients with complex problems. Digital interpretation offers a significant reduction in reading times and the cost of archiving.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It has long been supposed that the interference observed in certain patterns of coordination is mediated, at least in part, by peripheral afference from the moving limbs. We manipulated the level of afferent input, arising from movement of the opposite limb, during the acquisition of a complex coordination task. Participants learned to generate flexion and extension movements of the right wrist, of 75degrees amplitude, that were a quarter cycle out of phase with a 1-Hz sinusoidal visual reference signal. On separate trials, the left wrist either was at rest, or was moved passively by a torque motor through 50degrees, 75degrees or 100degrees, in synchrony with the reference signal. Five acquisition sessions were conducted on successive days. A retention session was conducted I week later. Performance was initially superior when the opposite limb was moved passively than when it was static. The amplitude and frequency of active movement were lower in the static condition than in the driven conditions and the variation in the relative phase relation across trials was greater than in the driven conditions. In addition, the variability of amplitude, frequency and the relative phase relation during each trial was greater when the opposite limb was static than when driven. Similar effects were expressed in electromyograms. The most marked and consistent differences in the accuracy and consistency of performance (defined in terms of relative phase) were between the static condition and the condition in which the left wrist was moved through 50degrees. These outcomes were exhibited most prominently during initial exposure to the task. Increases in task performance during the acquisition period, as assessed by a number of kinematic variables, were generally well described by power functions. In addition, the recruitment of extensor carpi radialis (ECR), and the degree of co-contraction of flexor carpi radialis and ECR, decreased during acquisition. Our results indicate that, in an appropriate task context, afferent feedback from the opposite limb, even when out of phase with the focal movement, may have a positive influence upon the stability of coordination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ability to generate enormous random libraries of DNA probes via split-and-mix synthesis on solid supports is an important biotechnological application of colloids that has not been fully utilized to date. To discriminate between colloid-based DNA probes each colloidal particle must be 'encoded' so it is distinguishable from all other particles. To this end, we have used novel particle synthesis strategies to produce large numbers of optically encoded particle suitable for DNA library synthesis. Multifluorescent particles with unique and reproducible optical signatures (i.e., fluorescence and light-scattering attributes) suitable for high-throughput flow cytometry have been produced. In the spectroscopic study presented here, we investigated the optical characteristics of multi-fluorescent particles that were synthesized by coating silica 'core' particles with up to six different fluorescent dye shells alternated with non-fluorescent silica 'spacer' shells. It was observed that the diameter of the particles increased by up to 20% as a result of the addition of twelve concentric shells and that there was a significant reduction in fluorescence emission intensities from inner shells as an increasing number of shells were deposited.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Results obtained with catches performed at several sites of the Ribeira Valley, SP (Brazil) are reported. Collections with Shannon type traps showed a concentration of An.albitarsis s.l. in the Experimental Farm of Pariquera-Açu County, associated with the development of irrigated rice cultivation. Two species of the complex, named A and B, were recognized. Species B predominated in the samples. Indoor and outdoor crepuscular human bait captures were performed a the domiciliary environment. The two species showed a generally low William's media valve of 0.2, the highest value obtained was 1.6. No differences were found between indoor and outdoor behaviours between the two species of the complex.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present the first version of a new tool to scan the parameter space of generic scalar potentials, SCANNERS (Coimbra et al., SCANNERS project., 2013). The main goal of SCANNERS is to help distinguish between different patterns of symmetry breaking for each scalar potential. In this work we use it to investigate the possibility of excluding regions of the phase diagram of several versions of a complex singlet extension of the Standard Model, with future LHC results. We find that if another scalar is found, one can exclude a phase with a dark matter candidate in definite regions of the parameter space, while predicting whether a third scalar to be found must be lighter or heavier. The first version of the code is publicly available and contains various generic core routines for tree level vacuum stability analysis, as well as implementations of collider bounds, dark matter constraints, electroweak precision constraints and tree level unitarity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resumo: Cement, as well as the remaining constituents of self-compacting mortars, must be carefully selected, in order to obtain an adequate composition with a granular mix as compact as possible and a good performance in the fresh state (self-compacting effect) and the hardened state (mechanical and durability-related behavior). Therefore in this work the possibility of incorporating nano particles in self-compacting mortars was studied. Nano materials are very reactive due mostly to their high specific surface and show a great potential to improve the properties of these mortars, both in mechanical and durability terms. In this work two nano materials were used, nano silica (nano SiO2) in colloidal state and nano titanium (nano TiO2) in amorphous state, in two types of self-compacting mortars (ratio binder:sand of 1:1 and 1:2). The self-compacting mortar mixes have the same water/cement ratio and 30% of replacement of cement with fly ashes. The influence of nano materials nano-SiO2 and nano-TiO2 on the fresh and hardened state properties of these self-compacting mortars was studied. The results show that the use of nano materials in repair and rehabilitation mortars has significant potential but still needs to be optimized. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we investigate some classes of semigroup rings with respect to (semi)primeness and (semi)primitivity. We do so by extending the techniques developed by Munn in (Proc R Soc Edinbur Sect A 107:175-196, 1987) and (Proc R Soc Edinbur Sect A 115:109-117, 1990) for the study of semigroup rings of inverse semigroups. Restriction, weakly ample and ample semigroups are considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Motivated by the dark matter and the baryon asymmetry problems, we analyze a complex singlet extension of the Standard Model with a Z(2) symmetry (which provides a dark matter candidate). After a detailed two-loop calculation of the renormalization group equations for the new scalar sector, we study the radiative stability of the model up to a high energy scale (with the constraint that the 126 GeV Higgs boson found at the LHC is in the spectrum) and find it requires the existence of a new scalar state mixing with the Higgs with a mass larger than 140 GeV. This bound is not very sensitive to the cutoff scale as long as the latter is larger than 10(10) GeV. We then include all experimental and observational constraints/measurements from collider data, from dark matter direct detection experiments, and from the Planck satellite and in addition force stability at least up to the grand unified theory scale, to find that the lower bound is raised to about 170 GeV, while the dark matter particle must be heavier than about 50 GeV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The response to interferon treatment in chronic hepatitis NANB/C has usually been classified as complete, partial or absent, according to the behavior of serum alanine aminotransferase (ALT). However, a more detailed observation of the enzymatic activity has shown that the patterns may be more complex. The aim of this study was to describe the long term follow-up and patterns of ALT response in patients with chronic hepatitis NANB/C treated with recombinant interferon-alpha. A follow-up of 6 months or more after interferon-a was achieved in 44 patients. We have classified the serum ALT responses into six patterns and the observed frequencies were as follows: I. Long term response = 9 (20.5%); II. Normalization followed by persistent relapse after IFN = 7 (15.9%); III. Normalization with transient relapse = 5 (11.9%); IV. Temporary normalization and relapse during IFN = 4 (9.1%); V. Partial response (more than 50% of ALT decrease) = 7 (15.9%); VI. No response = 12 (27.3%). In conclusion, ALT patterns vary widely during and after IFN treatment and can be classified in at least 6 types.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

IEEE International Conference on Cyber Physical Systems, Networks and Applications (CPSNA'15), Hong Kong, China.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Química e Bioquímica

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surgical procedures such as osteotomy and hip replacement involve the cutting of bone with the aid of various manual and powered cutting instruments including manual and powered bone saws. The basic mechanics of bone sawing processes are consistent with most other material sawing processes such as for wood or metal. Frictional rubbing between the blade of the saw and the bone results in the generation of localised heating of the cut bone. Research studies have been carried out which consider the design of the bone saw which deals with specifics of the saw teeth geometry and research which examines the effect of drilling operations on heating of the bone has shown that elevated temperatures will occur from frictional overheating. This overheating in localised areas is known to have an impact on the rate of healing of the bone post operation and the sharpness life of the blade. The purpose of this study was to measure the temperature at three zones at fixed intervals of 3mm, 6mm, and 9mm away from the cutting zone. It should be noted that it was the first time that this measurement technique was used to measure the temperature gradient through the bone specimen thereby establishing the extent to which clinicians are experiencing thermal injury during sawing of bone while using a reciprocating saw. The effect of various cutting feed rate on temperature elevation was also investigated in this research. The results showed that there will be a region of bone at least 9mm either side of the cutting blade experiencing thermal injury as temperatures in this region exceeded the threshold temperature of 44°C for necrosis (cell death).