911 resultados para Trace-metals


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Speciation studies of Fe, Cr, Co, Ni and Cu on reactive fraction (adsorved on oxides, hydroxides, carbonates and clay minerals) and pyrite were performed in Avicennia schaueriana and Rhizophora mangle sediments from Amapá shoreline-Brazil. The soil under Avicennia showed a higher heavy metal concentration in reactive fraction than under Rhizophora. The soil under Rhizophora showed low heavy metal bioavailability, having an increasing association with pyrite across sediment section.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Perfluoro and sulfonated ion-exchange polymers are recognized as a very useful material for various mechanistic studies and applications in electrochemistry. These polymers are characterized by high equivalent weights and by a low number of ion-exchange sites interposed between long organic chains. The solubility enables a preparation of stable polyelectrolyte films on the electrode surface. Examples of the determination of trace metals and organic componds in real environmental samples are presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Probably one of the most difficult and challenging aspects of measuring trace metals in natural waters is to avoid contamination during sampling, manipulation and analysis. This work discusses how to avoid contamination using simple procedures, and considers alternative methods to purify deionised water and low grade reagents to enable accurate determination of trace metals in natural waters in a common laboratory. Measurements were performed by cathodic stripping voltammetry and copper was used as a model metal to test the procedures. It was possible to evaluate copper speciation in natural waters even when total dissolved copper concentration was as low as 1.5 nmol L-1. The methods' accuracy was confirmed by analysis of certified seawater.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The subsoil of the Vale do Ribeira was the focus of mining industries for the exploration of lead, mainly inside the park - PETAR. Despite the fact that the exploration has ended, the environmental effects of those activities are still present, due to great amounts of heavy metals that are leached. Concentrations of pseudo-total and bioavailable metals were determined in sediment samples of the Betari River, using atomic absorption spectrometry. The results demonstrated that the sediments are contaminated by Pb, Zn and Cu. The findings can contribute to an efficient and environmentally and economically adequate management of the park, for the conservation and the protection of the area.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Iron, copper and lead distribution was evaluated in sediment cores from a disturbed mangrove area in Guanabara Bay: a core from a seaward site where mangrove vegetation was removed ~20 yr before sampling (MD); a core from an intermediate site with dead vegetation, apparently due to insect attack (MP), and a core from a landward site with living vegetation (MV). Metal concentrations showed increasing values seaward while organic matter content showed an inverse trend, displaying a negative correlation with metals. This unusual correlation indicates opposite sources, since metals come from the bay and the main OM origin is probably degraded mangrove vegetation. Plant cover loss seems to be a critical factor affecting metal accumulation, particularly due to changes in OM input.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Measurements of acid volatile sulfide (AVS) and simultaneously extracted metals (SEM) were combined in order to verify the ecological hazard of contaminated sediments from the Santos-Cubatão Estuarine System (SE Brazil), which is located in one of the most industrialized areas in the Latin America. Intertidal sediments from the Morrão River estuary were collected seasonally in short cores. The redox conditions, organic matter contents and grain-size were the main controlling factors on SEM distribution. However, clear relationships among these variables and AVS were not observed. The molar SEM/AVS ratios were frequently > 1 especially in the summer, suggesting major metal bioavailability hazard in this humid hot season.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Rainfall samples collected in the downtown area of São Paulo city, during 2003, exhibited average concentrations of cadmium, lead and copper of 1.33, 8.52 and 49.5 nmol L-1, respectively. Among the major ions, NH4+ was the predominant species followed by NO3-, SO4(2-) and Ca2+, with volume weighed mean (VWM) concentrations of 37.1, 20.1, 11.9 and 10.8 µmol L-1, respectively. All the determined species showed high inter-events variability, including free H+ ions whose VWM concentration was 4.03 µmol L-1, corresponding to a pH value of 5.39.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Trace metals (Cd, Cu, Pb and Zn) enrichment, availability and contamination in superficial sediments of three interconnected urban lagoons localized in Concepción-Chile, were evaluated. According to the results of geochemical fracctionation analysis, Cu and Pb are rather associated with oxi-hydroxides, Cd is associated with exchangeable and carbonates fraction, while Zn is mainly associated with organic, oxi-hydroxides and residual fraction. The estimation of the availability percentages indicate that Cu is the most mobile metal and the less mobile is the Cd. An evaluation of the geo-accumulation index and urban industrial pollution allowed to classify the studied zone as moderately to highly contaminated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this study was to assess a new monitoring technique of particulate and trace metals in the atmosphere via the use of a passive sampler of air pollutants in the city of Goiânia. The average particulate weight and average concentrations of metals Fe, Cr, Zn, Pb, Cu, Mn, and Cd were 0.1104 g and 257.5; 23.4; 17.8; 6.7; 1.9; 0.8; 0.2 μg/m²/day, respectively. Higher Pb and Cr concentrations were obtained in areas with intense traffic. This study revealed that it is possible to monitor trace metals with passive sampling, developed at a low cost and operational facility.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The determination of the airborne particulate matter (PTS) mass and trace metals concentrations were performed in three sites in Ouro Preto, MG, Brazil. It was evaluated 288 samples. The legal limit of annual geometric average (60 µg m-3) to PTS concentrations didn't exceed, but the legal limit for 24 h (240 µg m-3) did in three measurements. Seven metals (Al, Cr, Cu, Fe, Mn, Ni, Pb) analysed by ICP-AES were quantified in 18 samples. Aluminum and iron showed the highest concentrations, indicating the contribution of the soil and of one aluminum plant. The high nickel concentration is probably due to vehicular emissions and industrial combustion processes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Speciation of metals in a synthetic freshwater was comparatively evaluated using Anodic Stripping Voltammetry, Diffusive Gradients in Thin Films and a Chemical Equilibrium Model. The labile fractions of Cu and Zn quantified by DGT were similar to the ones measured by ASV. The labile species of Cd and Pb could not be determined by both experimental methods due to the formation of inert complexes with organic ligands in the sample. Despite the differences among the methods, the speciation results obtained by the use of DGT and ASV agreed well with predictions made by the chemical equilibrium model.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Surface sediments from the River São Francisco were analyzed to investigate the impact, due to the presence of metals (Cd, Cu, Pb, Zn) in wastes from a metallurgical industry in the city of Três Marias/MG, Brazil. The concentrations and geochemical associations of Pb, Zn and trace metals associated with the minerals employed in zinc production were measured. Sediments close to discharge locations were highly contaminated with Pb (332-512 μg g-1) and Zn (7872-10780 μg g-1), with values decreasing rapidly due to dilution and hydraulic sorting. Evaluation of toxicity according to the Consensus-based Sediment Quality Guidelines indicated for Cd, Pb and Zn a high probability of adverse effects on aquatic biota at these sites.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Corals incorporate major and trace elements in their tissues and skeletons, acting as good proxies for contaminant inputs over time. This incorporation occurs by a variety of mechanisms and depends on the bioavailability of elements. Corals are very susceptible to metal contamination during sample collection. As such, pre-treatment procedures need to include a decontamination step. The high Na and Ca concentrations in the matrix make the determination of trace metals an analytical challenge. The present paper reviews all the information published on coral sample pretreatments, metal determinations in corals, and also discusses the use of coral to monitor metal contamination.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Lead and copper concentrations in drinking water increase considerably on going from municipality reservoirs to the households sampled in Ribeirão Preto (SP-Brazil). Flushing of only 3 liters of water reduced metal concentrations by more than 50%. Relatively small changes in water pH rapidly affected corrosion processes in lead pipes, while water hardness appeared to have a long-term effect. This approach aims to encourage University teachers to use its content as a case study in disciplines of Instrumental Analytical Chemistry and consequently increase knowledge about drinking water contamination in locations where no public monitoring of trace metals is in place.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Original sludge from wastewater treatment plants (WWTPs) usually has a poor dewaterability. Conventionally, mechanical dewatering methods are used to increase the dry solids (DS) content of the sludge. However, sludge dewatering is an important economic factor in the operation of WWTPs, high water content in the final sludge cake is commonly related to an increase in transport and disposal costs. Electro‐dewatering could be a potential technique to reduce the water content of the final sludge cake, but the parameters affecting the performance of electro‐dewatering and the quality of the resulting sludge cake, as well as removed water, are not sufficiently well known. In this research, non‐pressure and pressure‐driven experiments were set up to investigate the effect of various parameters and experimental strategies on electro‐dewatering. Migration behaviour of organic compounds and metals was also studied. Application of electrical field significantly improved the dewatering performance in comparison to experiments without electric field. Electro‐dewatering increased the DS content of the sludge from 15% to 40 % in non‐pressure applications and from 8% to 41% in pressure‐driven applications. DS contents were significantly higher than typically obtained with mechanical dewatering techniques in wastewater treatment plant. The better performance of the pressure‐driven dewatering was associated to a higher current density at the beginning and higher electric field strength later on in the experiments. The applied voltage was one of the major parameters affecting dewatering time, water removal rate and DS content of the sludge cake. By decreasing the sludge loading rate, higher electrical field strength was established between the electrodes, which has a positive effect on an increase in DS content of the final sludge cake. However interrupted voltage application had anegative impact on dewatering in this study, probably because the off‐times were too long. Other factors affecting dewatering performance were associated to the original sludge characteristics and sludge conditioning. Anaerobic digestion of the sludge with high pH buffering capacity, polymer addition and freeze/thaw conditioning had a positive impact on dewatering. The impact of pH on electro‐dewatering was related to the surface charge of the particles measured as zeta‐potential. One of the differences between electro‐dewatering and mechanical dewatering technologies is that electro‐dewatering actively removes ionic compounds from the sludge. In this study, dissolution and migration of organic compounds (such as shortchain fatty acids), macro metals (Na, K, Ca, Mg, Fe) and trace metals (Ni, Mn, Zn, Cr) was investigated. The migration of the metals depended on the fractionation and electrical field strength. These compounds may have both negative and positive impacts on the reuse and recycling of the sludge and removed water. Based on the experimental results of this study, electro‐dewatering process can be optimized in terms of dewatering time, desired DS content, power consumption and chemical usage.