954 resultados para To-mouth Resuscitation


Relevância:

40.00% 40.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A series of in-line curvature sensors on a garment are used to monitor the thoracic and abdominal movements of a human during respiration. These results are used to obtain volumetric tidal changes of the human torso showing reasonable agreement with a spirometer used simultaneously to record the volume at the mouth during breathing. The curvature sensors are based upon long period gratings written in a progressive three layered fibre that are insensitive to refractive index changes. The sensor platform consists of the long period grating laid upon a carbon fibre ribbon, which is encapsulated in a low temperature curing silicone rubber. An array of sensors is also used to reconstruct the shape changes of a resuscitation manikin during simulated respiration. The data for reconstruction is obtained by two methods of multiplexing and interrogation: firstly using the transmission spectral profile of the LPG's attenuation bands measured using an optical spectrum analyser; secondly using a derivative spectroscopy technique.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This material is based upon work supported by the National Science Foundation through the Florida Coastal Everglades Long-Term Ecological Research program under Cooperative Agreements #DBI-0620409 and #DEB-9910514. This image is made available for non-commercial or educational use only.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Covers area now occupied by the Mall.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pen-and-ink on tracing paper, mounted on cloth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: This study evaluated the quality of DNA obtained from stored human saliva and its applicability to human identification. METHODS: The saliva samples of 20 subjects, collected in the form of saliva in natura and from mouth swabs and stored at -20ºC, were analyzed. After 7 days, the DNA was extracted from the 40 saliva samples and subjected to PCR and electrophoresis. After 180 days, the technique was repeated with the 20 swab samples. RESULTS: The first-stage results indicated that DNA was successfully extracted in 97.5% of reactions, 95% of saliva in natura and 100% of swab saliva samples, with no statistically significant difference between the forms of saliva. In the second phase, the result was positive for all 20 analyzed samples (100%). Subsequently, in order to analyze the quality of the DNA obtained from human saliva, the SIX3-2 gene was tested on the 20 mouth swab samples, and the PCR products were digested using the MbO1 restriction enzyme to evaluate polymorphisms in the ADRA-2 gene, with positive results for most samples. CONCLUSION: It was concluded that the quantity and quality of DNA from saliva and the techniques employed are adequate for forensic analysis of DNA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Cananéia-Iguape system, SE Brazil, consists of a complex of lagoonal channels, located in a United Nations Educational, Scientific and Cultural Organization (UNESCO) Biosphere Reserve. Nevertheless, important environmental changes have occurred in approximately the last 150 yrs due to the opening of an artificial channel, the Valo Grande, connecting the Ribeira de Iguape River to the lagoonal system. Our objective is to assess the historical record of the uppermost layers of the sedimentary column of the lagoonal system in order to determine the history of environmental changes caused by the opening of the artificial channel. In this sense, an integrated geochemical-faunal approach is used. The environmental changes led significant modifications in salinity, in changes of the depositional patterns of sediments and foraminiferal assemblages (including periods of defaunation), and, more drastically, in the input of heavy metals to the coastal environment. The concentrations Pb in the core analyzed here were up to two times higher than the values measured in contaminated sediments from the Santos estuary, the most industrialized coastal zone in Brazil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the southern region of Mato Grosso do Sul state, Brazil, a foot-and-mouth disease (FMD) epidemic started in September 2005. A total of 33 outbreaks were detected and 33,741 FMD-susceptible animals were slaughtered and destroyed. There were no reports of FMD cases in other species than bovines. Based on the data of this epidemic, it was carried out an analysis using the K-function and it was observed spatial clustering of outbreaks within a range of 25km. This observation may be related to the dynamics of foot-and-mouth disease spread and to the measures undertaken to control the disease dissemination. The control measures were effective once the disease did not spread to farms more than 47 km apart from the initial outbreaks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is well known that carbohydrate (CHO) supplementation can improve performance in endurance exercises through several mechanisms such as maintenance of glycemia and sparing endogenous glycogen as well as the possibility of a central nervous-system action. Some studies have emerged in recent years in order to test the hypothesis of ergogenic action via central nervous system. Recent studies have demonstrated that CHO mouth rinse can lead to improved performance of cyclists, and this may be associated with the activation of brain areas linked to motivation and reward. These findings have already been replicated in other endurance modalities, such as running. This alternative seems to be an attractive nutritional tool to improve endurance exercise performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of this study was to investigate the effect of low-level laser therapy (LLLT) on the treatment of burning mouth syndrome (BMS). In addition, the laser effect was compared on the different affected oral sites. Materials and Methods: Eleven subjects with a total of 25 sites (tongue, lower lip, upper lip, and palate) affected by a burning sensation were selected. The affected areas were irradiated once a week for three consecutive weeks with an infrared laser (lambda = 790 nm). The probe was kept in contact with the tissue, and the mucosal surface was scanned during the irradiation. The exposure time was calculated based on the fluence of 6 J/cm(2), the output power of 120 mW, and the area to be treated. Burning intensity was recorded through a visual analog scale before and after the treatment and at the 6-week follow-up. The percentage of the improvement in symptoms was also obtained. Results: Burning intensity at the end of the laser therapy was statistically lower than at the beginning (p < 0.01). Patients reported an 80.4% reduction in the intensity of symptoms after laser treatment. There was no statistical difference between the end of the treatment and the 6-week follow-up, except for the tongue site. Conclusion: Under the investigated parameters, infrared LLLT proved to be a valuable alternative for BMS treatment, providing a significant and lasting reduction in symptoms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It has been previously reported that carbohydrate (CHO) mouth rinse can improve exercise performance. The proposed mechanism involves increased activation of brain regions believed to be responsible for reward/motivation and motor control. Since strength-related performance is affected by central drive to the muscles, it seems reasonable to hypothesize that the positive CNS response to oral CHO sensing may counteract the inhibitory input from the muscle afferent pathways minimizing the drop in the central drive. The purpose of the current study was to test if CHO mouth rinse affects maximum strength and strength endurance performance. Twelve recreationally strength-trained healthy males (age 24.08 +/- 2.99 years; height 178.09 +/- 6.70 cm; weight 78.67 +/- 8.17 kg) took part in the study. All of the tests were performed in the morning, after an 8 h overnight fasting. Subjects were submitted to a maximum strength test (1-RM) and a strength endurance test (six sets until failure at 70% of 1-RM), in separate days under three different experimental conditions (CHO mouth rinse, placebo-PLA mouth rinse and control-CON) in a randomized crossover design. The CHO mouth rinse (25 ml) occurred before every attempt in the 1-RM test, and before every set in the endurance strength test. Blood glucose and lactate were measured immediately before and 5 min post-tests. There were no significant differences in 1-RM between experimental conditions (CHO 101 +/- 7.2 kg; PLA 101 +/- 7.4 kg; CON 101 +/- 7.2 kg; p = 0.98). Furthermore, there were no significance between trial differences in the number of repetitions performed in each set (p = 0.99) or the total exercise volume (number of repetitions x load lifted [kg]) (p = 0.98). A main effect for time (p < 0.0001) in blood lactate concentration was observed in both tests (1-RM and strength endurance). Blood glucose concentration did not differ between conditions. In conclusion, CHO mouth rinse does not affect maximum strength or strength endurance performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Swallowing dynamics involves the coordination and interaction of several muscles and nerves which allow correct food transport from mouth to stomach without laryngotracheal penetration or aspiration. Clinical swallowing assessment depends on the evaluator`s knowledge of anatomic structures and of neurophysiological processes involved in swallowing. Any alteration in those steps is denominated oropharyngeal dysphagia, which may have many causes, such as neurological or mechanical disorders. Videofluoroscopy of swallowing is presently considered to be the best exam to objectively assess the dynamics of swallowing, but the exam needs to be conducted under certain restrictions, due to patient`s exposure to radiation, which limits periodical repetition for monitoring swallowing therapy. Another method, called cervical auscultation, is a promising new diagnostic tool for the assessment of swallowing disorders. The potential to diagnose dysphagia in a noninvasive manner by assessing the sounds of swallowing is a highly attractive option for the dysphagia clinician. Even so, the captured sound has an amount of noise, which can hamper the evaluator`s decision. In that way, the present paper proposes the use of a filter to improve the quality of audible sound and facilitate the perception of examination. The wavelet denoising approach is used to decompose the noisy signal. The signal to noise ratio was evaluated to demonstrate the quantitative results of the proposed methodology. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Positive end expiratory pressure (PEEP) is important for neonatal ventilation but is not considered in guidelines for resuscitation. Our aim was to investigate the effects of PEEP on cardiorespiratory parameters during resuscitation of very premature lambs delivered by hysterotomy at similar to125 d gestation (term similar to147 d). Before delivery, they were intubated and lung fluid was drained. Immediately after delivery, they were ventilated with a Drager Babylog plus ventilator in volume guarantee mode with a tidal volume of 5 mL/kg. Lambs were randomized to receive 0, 4, 8, or 12 cm H2O of PEEP. They were ventilated for a 15-min resuscitation period followed by 2 h of stabilization at the same PEEP. Tidal volume, peak inspiratory pressure, PEEP, arterial pressure, oxygen saturation, and blood gases were measured regularly, and respiratory system compliance and alveolar/ arterial oxygen differences were calculated. Lambs that received 12 cm H2O of PEEP died from pneumothoraces; all others survived without pneumothoraces. Oxygenation was significantly improved by 8 and 12 cm H2O of PEEP compared with 0 and 4 cm H2O of PEEP. Lambs with 0 PEEP did not oxygenate adequately. The compliance of the respiratory system was significantly higher at 4 and 8 cm H2O of PEEP than at 0 PEEP. There were no significant differences in partial pressure of carbon dioxide in arterial blood between groups. Arterial pressure was highest with 8 cm H2O of PEEP, and there was no cardiorespiratory compromise at any level of PEEP. Applying PEEP during resuscitation of very premature infants might be advantageous and merits further investigation.